Benchmark in Atmospheric Distillation Testing
OPTIDIST
™
www.paclp.com
by
The Optimal Solution in Distillation Testing
• User-friendly, straightforward operation with superior precision from the first run
• Unparalleled versatility for significant laboratory time and cost savings
• Enhanced built-in instrument safety features
• In compliance with ASTM D86 (group 0,1,2,3,4), D1078, D850, EN ISO3405, ISO 918,
IP123, IP195, DIN51751, JIS K2254, NFN 07-002
OPTIDIST™, THE BENCHMARK IN ATMOSPHERIC DISTILLATION TESTING
OptidistTM
With eighty years of combined experience between the companies Walter Herzog and ISL in designing and
manufacturing automatic distillation equipment, they directed PAC to the development of the most revolutionary
automated distillation analyzer ever built. OptiDist™ is the State-of-the-Art Optimal Solution for performing
atmospheric distillation, offering the most precision and ease of use ever seen. The versatile design enables
multi-methods and non-standard capability and therefore can easily be adapted for different applications. The
testing and results are in full compliance with all atmospheric distillation methods.
EASY TO USE, ONE BUTTON STRAIGHTFORWARD OPERATION
Only the OptiDist™ enables truly “one button,” straightforward operation. The easy to use distillation analyzer
with advanced Man Machine Interface (MMI) features, such as the built-in Optimizer, contributes to a trouble-free
operation requiring less operator expertise. Without preliminary trials and manual heater settings, the operator
selects the test method and starts the distillation by just pressing the “Start” button.
MISTAKE PROOF UNIT
• With one hand quickly install
the flask with automatic
detection
• Intelligent Vapor Probe
memorizes calibration data
and does not require manual
adjustment in the flask neck
• Automatic base plate
detection
• Self-positioning heater lift
EASY TO OPERATE TOUCH
SCREEN INTERFACE
Start a test in only three steps:
1. E
nter sample number
2. S
elect product (e.g distillation
group
3. Push startbutton
The user does not have to enter
individual heater parameters per
sample.
CORROSION RESISTANT RECEIVER CHAMBER
•A utomatic charge volume measurement for precise
sample volume
• Automatic alarm for condenser cleaning
QUICK AND EASY FLASK
INSTALLATION IN LESS
THAN 10 SECONDS!
Operators no longer need to deal with
distillation flask issues, such as difficult
installation and risks of breaking off the
arm when setting it into the baseplate. The
Optidist enables the operator to install the
flask (1 and 2) and the self-positioning
heater lift adjusts the settings automatically,
using only one hand and all within seconds!
SUPERIOR PRECISION FROM THE FIRST RUN ADVANCED, BUILT-IN
The OptiDist™ automatically sets the optimal distillation conditions for any SAFETY FEATURES
sample through the unique heating optimizer technology. It delivers up to two The OptiDist assures perfect
times better precision for all common distillation samples. No more precious repeatability of distillation conditions
time is lost on repeating tests; you get perfect results from the first run, even without compromising safety. The
for “unknown” samples! The following example shows a precision study for optimized heating prevents critical
ethanol blends in which units with and without the Optimizer technology overheating of the distillation flask,
were compared. The study shows a significant improvement in precision improves flask life-time, and protects
performance for units with the Optimizer. from potential fires. The Optidist has
Boiling Curve of a Typical
a built-in fire extinguisher to further
Gasoline E10 increase safety.
The VOC- blower reduces volatile
organic compound (VOC) emissions
before the operator opens the receiver
chamber and protects the operator from
exposure to harmful sample vapours.
STATE OF THE ART
Precision Data Comparison OPTIDIST TECHNOLOGY
FULLY AUTOMATED REGULATION
WITH UNIQUE OPTIMIZER
• Fully automatic initial heat regulation;
no sample specific heat parameters
required
Old model
• Fully automatic final heat adjustment
OptiDist
for the last 5 ml to distillate
Distillation Rate Comparison
• Automatic residue and loss calculation
• Perfect results on the first test, even
for “unknown” samples
Old model CRUDE ANALYSIS WITH
OptiDist
BOOST HEATER
The incorporated boost heater is a
Due to the azeotropic behavior of ethanol blends, the previous generation of unique OptiDist feature that allows
instruments cannot maintain the distillation rate within 4 to 5 ml/min. running crude oil samples according
The units with advanced Optimizer technology can maintain the distillation to GOST 2170 part B.
rate much better since the Optimizer technology considers the liquid
temperature as an additional regulation parameter. The study shows the
results are within the method limits of 4-5 ml per minute.
SIGNIFICANT LABORATORY TIME AND COST SAVINGS
A Typical distillation analyzer The Herzog OptiDist
Operator Training Complicated operation requires system users to be High level of automation makes the system mistake proof;
Cost savings extensively trained. No extensive operator training required.
Laboratory 2 - 3 attempts are required to have the correct initial The Optimizer ensures perfect results starting with the first
efficiency heating setting to meet the IBP and 5% with the first run without time-consuming and costly re-work
test as required by the method
Time Savings Analysis time is 135 minutes Analysis time is 35 min; time-saving of 60%!
Sample Volume Savings 200 - 300 ml sample volume required Only 100 ml required for a full distillation test
solidpartners
provensolutions
U.S.A. Multiple Units netware operation with PAC IRIS Software for OptiDist
PAC, LP | 8824 Fallbrook Drive | Houston, Texas 77064
Users can choose to have the OptiDist operate as a stand-alone unit or benefit
T: +1 800.444.TEST | O: +1 281.940.1803 | F: +1 281.580.0719
[email protected] | [email protected] from using it in a PC-controlled netware with PAC IRIS Software:
• Simple, straightforward connection setup and use
FRANCE • Connect lab instruments locally or from anywhere in the world LIMS
BP 70285 | Verson | 14653 CARPIQUET Cedex
• Password protection at various levels
T: +33 231 264 300 | F: +33 321 266 293
[email protected] | [email protected] • User traceability
• Designed for regulatory compliance
GERMANY • Integrated statistical process control charting
Badstrasse 3-5 | P.O.Box 1241 | D-97912 Lauda-Königshofen,
• Remotely control multiple instruments from a single workstation
T: +49 9343 6400 | F: +49 9343 640 101
[email protected]| [email protected] • Consistent look and feel interfaces for easy adoption
• Customization available to meet laboratory specific needs
SINGAPORE • Centralized database for results, products, methods and reports
61 Science Park Road | #03-09/10 The Galen
• Share printer for multiple instruments
Singapore Science Park III | Singapore 117525
T: +65 6412 0890 | F: +65 6412 0899 • Centralized LIMS transfer and configuration
[email protected] | [email protected]
NETHERLANDS SPECIFICATIONS
P.O.Box 10.054 | 3004 AB Rotterdam
Innsbruckweg 35 | 3047 AG Rotterdam Ordering Information OptiDist™, a compact self-contained instrument with factory filled CFC-free
T: +31 10 462 4811 | F: +31 10 462 6330 cooling system, delivered with 125ml flask, 100ml receiver cylinder, vapor probe
[email protected] | [email protected] with centering device, heater plates 38 and 50mm, flask connection silicone tube,
receiver cap and condenser cleaner
RUSSIA
Shabolovka Street | 34, Bldg. 2 | 115419 Moscow Standard Test Methods ASTM D86 (group 0,1,2,3,4), D1078, D850, IP195, IP123, DIN51751, NFM07-002,
T: +7 495 617 10 86 | F: +7 495 913 97 65 EN ISO3405, JIS K2254, ISO918; ASTM D189, D524, D4350. EN ISO 10370*
[email protected] | [email protected] *OptiDist can prepare the 10% bottom residue for EN ISO 10370
CHINA Operation Large graphic TFT-LCD color touch-screen with solvent-proof protection
Room 1003, Sunjoy Mansion | No. 6 RiTan Rd. User Interface Low mass and low voltage, self-positioning heating system
Chao Yang District | Beijing 100020 Heating System Unique Optimizer function for fully automatic initial heat settings and heating
T: +86 10 650 72236 | F: +86 10 650 72454
[email protected] | [email protected] regulation; detectors for heater plate, vapor probe and centering device
Temperature range from 0 to 65°C (32 to 149°F); programmable constant
INDIA Condenser System temperature, temperature ramping or special temperature profile; instantaneously
Continuing research and development may result in specifications or appearance changes at any time
403, Sentinel, Central Avenue, Hiranandani Gardens ready at switch on
Powai, Mumbai - 400 076 INDIA
Temperature range from 0 to 40°C (32 to 104°F); corrosion proof design;
T : +91-22-2570 3636 Receiving Chamber
[email protected] | [email protected] programmable temperature or automatic adjustment to sample charge
temperature; compatible with 100ml and 200ml receiver cylinders
MIDDLE EAST
Measurements Range: 0 to 450°C (32 to 842°F), accuracy Pt 100 IEC 751 probe Class A
A1 Quds Street, A1 Tawar road | LIU#H13 Dubai Airport Freezone
Near Dubai Airport (terminal 2) | P.O.Box #54781 | Dubai, UAE Vapor Temperature Built in calibration memory with 10 point calibration table and automatic probe ID
T: +971 04 2947 995 | F: +971 04 2395 465 detection; calibration history; optional calibration certificate
[email protected] | [email protected] Sample Volume Optical measuring system compatible with samples producing smoke in the
receiver; range 0 to 103% charge volume; resolution: 0.03ml, accuracy: ± 0.1ml
SOUTH KOREA Ambient Pressure Built-in pressure sensor, range to 70 to 110 kPa A (500 to 800 mmHg)
#621 World Vision Building | 24-2, Youido-dong
Seoul 150-010 Calibration: Single point against reference barometer
T: +82 2785 3900 | F: +82 2785 3977
Safety Built in fire extinguisher with 2 fire sensors
[email protected] | [email protected]
User Errors Prevention Detector for heater base plate type, Detector for vapor probe and centering device
THAILAND Detectors for “receiver in place” and “receiver chamber door open”
26th Floor, M. Thai Tower | All Seasons Place
Detector for “condenser cleaned”
87 Wireless Road | Lumpini, Phatumwan | Bangkok 10330
T: +66 2627 9410 | F: +662627 9401 PAC IRIS Software • Run Control • Instrument • Quality Control • Test Start
[email protected] | [email protected] features for OptiDist • Results Parameters • Method Definition • Results Evaluation
• Calibration • Reports • Specs Definition
PAC Authorized Representatives are also located in most
countries worldwide. For more information visit www.paclp.com
Connectivity 3 USB for external printer, barcode reader and memory stick; RS232C serial port
for LIMS connection; Ethernet RJ45 port for LIMS connection and unit networking;
HERZOG BY PAC Connection to external PC with PAC IRIS Software
Herzog, originally established in 1937, is a Operating Requirements Temperature 10 to 35°C (50 to 95°F); relative humidity up to 80% at 35°C (95°F)
long-established comprehensive line of laboratory
Multi Voltage 100 to 240V; 1400 W
instruments for testing distillation, flash point, vapor
pressure, bitumen testing, cold flow properties, Dimensions and Weight 44cm W * 57cm D * 65cm H (17,3’’ * 22,4’’ * 25,6’’); 68kg (150lb)
viscosity and other physical properties of materials.
Copyright 2015/1 PAC L.P. All rights reserved 820-736
www.paclp.com ® ®