LTE/5G
For all the parameters for EutrancellFDD MO. Just enter below command in CLI
cmedit get SITENAME EutranCellFDD.(*) -t Example mo’s:
LTE MO’s
RetSubunit.(*);
Enodebfunction.(*);
UtranFreqRelation.(*);
GUtranCellRelation.(*);
GUtranFreqRelation.(*);
TermPointToGNB.(*);
GUtranSyncSignalFrequency.(*);
ExternalGNodeBFunction.(*);
ExternalEnodeBFunction.(*);
EUtranCellRelation.(*);
ReportConfigB1NR.(*);
ReportConfigB1GUtra.(*);
GUtraNetwork.(*);
EndcProfile.(*);
EndcProfilePredefined.(*);
5G MO’s
UeMeasControl.(*);
ExternalENodeBFunction.(*);
ReportConfigA2.(*);
ReportConfigA3.(*);
ReportConfigB1NR.(*);
QciProfileEndcConfig.(*);
QciProfileEndcConfigExt.(*);
NRNetwork.(*);
NRFreqRelation.(*);
NRFrequency.(*);
FieldReplaceableUnit.(*);
TermPointToGNBDU.(*);
TermPointToGNBCUCP.(*); NRSectorCarrier.(*);
3G CLI Cmds:
cmedit get * RncFunction.(rncId) -t cmedit
get RNCID Utrancell.() –t
cmedit get
SubNetwork=ONRM_ROOT_MO,SubNetwork=RNCIDhere,MeContext=RNCIDhere,ManagedElement=1,RncFunction=1,UtranCell=
CELLNAMEher e
-attr cId,primaryscramblingcode,routingarearef -t cmedit
get RNCIDHere
UtranCell.(administrativeState,antennaPosition,cellBroadcastSac,cellReserved,cId,maximumTransmissionPower,primaryCpichPowe
r,primarySch
Power,primaryScramblingCode,pwrAdm,qQualMin,qRxLevMin,sInterSearch,sIntraSearch,sRatSearch,uarfcnDl,uarfcnUl,uraRef,routi
ngAreaRef,lo cationAreaRef) –t
cmedit get SubNetwork=ONRM_ROOT_MO,SubNetwork=RNCidhere,MeContext=RNCIDhere,ManagedElement=1,RncFunction=1
-attr rncId
cmedit get SITEIDhere Slot.(SlotId==1,productdata.{productName}) -t or
cmedit get [H;K*;G;N*] Slot.(SlotId==1,productdata.{productName}) -t (Here Site ID starts with first letter which is defined in your
Network
remove square brackets)
cmedit get
SubNetwork=ONRM_ROOT_MO,SubNetwork=RNCIDhere,MeContext=RNCIDhere,ManagedElement=1,RncFunction=1,UtranCell=
CELLNAMEher e
For Node Level Parameters MO is different
cmedit get
SubNetwork=ONRM_ROOT_MO,SubNetwork=RNCIDhere,MeContext=SITEIDhere,ManagedElement=SiteIDhere,NodeBFunct
ion=1,NodeBL ocalCellGroup=1,NodeBLocalCell=S1C1
3G MO’s
cmedit get 211092 nodebfunction.() -t
RbsLocalCell
RbsSynchronization
ConfigurationVersion
SwManagement
FeatureState
FeatureKey
CapacityKey
NodeBLocalCellGroup
cmedit get * featurestate.licensestate
CLI Commands GSM_2G Network
cmedit get * MONAME.(*),SecondaryMONAME.(*) or SecondaryMONAME.(specify attributes separated by “,”
Commas to get only required parameters)
cmedit get * GeranCell.(gerancellid==CELLNAME),”MONAME.(*)” or ”MONAME.(specify attributes separated by “,”
Commas)”
cmedit get NetworkElement=EBS17JM
CmFunction.() -t
cmedit get NetworkElement=EBS17JM
CmFunction.syncStatus -t
cmedit get * GeranCell.(gerancellid==CELLNAME),IdleModeAndPaging.(accmin,cro,crh,nccperm,pt,att) -t
o get all TG and site name in 2G network via CLI in ENM. and to check the TRX and TG T
cmedit get * G12Tg.rSite -
cmedit get * G12Tg.rSite -t
cmedit get * G31Tg.rSite
cmedit get * G12Tg.moAdmState
cmedit get *
G12Trxc.moAdmState -t
IDLE MODE & ChannelAlloc CLI
CMDs
cmedit get
SubNetwork=ONRM_ROOT_MO,SubNetwork=AXE,MeContext=BSCNAME,ManagedElement=BSCNAME,BscFunction=1,BscM=1,
GeranCellM=1,G eranCell=CELLNAME,IdleModeAndPaging=1
cmedit get
SubNetwork=ONRM_ROOT_MO,SubNetwork=AXE,MeContext=BSCNAME,ManagedElement=BSCNAME,BscFunction=1,BscM=1,
GeranCellM=1,G eranCell=CELLNAME,ChannelAllocAndOpt=1 cmedit get
SubNetwork=ONRM_ROOT_MO,SubNetwork=AXE,MeContext=BSCNAME,ManagedElement=BSCNAME,BscFunction=1,BscM=1,
GeranCellM=1,G eranCell=CELLNAME,ChannelAllocAndOpt=1,Vamos=1 cmedit get
SubNetwork=ONRM_ROOT_MO,SubNetwork=AXE,MeContext=BSCNAME,ManagedElement=BSCNAME,BscFunction=1,BscM=1,
GeranCellM=1,G eranCell=CELLNAME,ChannelAllocAndOpt=1,CellLoadSharing=1 cmedit get
SubNetwork=ONRM_ROOT_MO,SubNetwork=AXE,MeContext=BSCNAME,ManagedElement=BSCNAME,BscFunction=1,BscM=1,
GeranCellM=1,G eranCell=CELLNAME,ChannelAllocAndOpt=1,DynamicFrHrModeAdaption=1 cmedit get
SubNetwork=ONRM_ROOT_MO,SubNetwork=AXE,MeContext=BSCNAME,ManagedElement=BSCNAME,BscFunction=1,BscM=1,
GeranCellM=1,G eranCell=CELLNAME,ChannelAllocAndOpt=1,DynamicHrAllocation=1 cmedit get
SubNetwork=ONRM_ROOT_MO,SubNetwork=AXE,MeContext=BSCNAME,ManagedElement=BSCNAME,BscFunction=1,BscM=1,
GeranCellM=1,G eranCell=CELLNAME,ChannelAllocAndOpt=1,IdleChannelMeasurement=1 cmedit get
SubNetwork=ONRM_ROOT_MO,SubNetwork=AXE,MeContext=BSCNAME,ManagedElement=BSCNAME,BscFunction=1,BscM=1,
GeranCellM=1,G eranCell=CELLNAME,ChannelAllocAndOpt=1,SubcellLoadDistribution=1
GPRS CLI CMDs
cmedit get
SubNetwork=ONRM_ROOT_MO,SubNetwork=AXE,MeContext=BSCNAME,ManagedElement=BSCNAME,BscFunction=1,BscM=1,
GeranCellM=1,G eranCell=CELLNAME,Gprs=1 cmedit get
SubNetwork=ONRM_ROOT_MO,SubNetwork=AXE,MeContext=BSCNAME,ManagedElement=BSCNAME,BscFunction=1,BscM=1,
GeranCellM=1,G eranCell=CELLNAME,Gprs=1,TbfReservation=1 Power Control CLI CMDs
cmedit get
SubNetwork=ONRM_ROOT_MO,SubNetwork=AXE,MeContext=BSCNAME,ManagedElement=BSCNAME,BscFunction=1,BscM=1,
GeranCellM=1,G eranCell=CELLNAME,PowerControl=1 cmedit get
SubNetwork=ONRM_ROOT_MO,SubNetwork=AXE,MeContext=BSCNAME,ManagedElement=BSCNAME,BscFunction=1,BscM=1,
GeranCellM=1,G eranCell=CELLNAME,PowerControl=1,PowerControlDownlink=1 cmedit get
SubNetwork=ONRM_ROOT_MO,SubNetwork=AXE,MeContext=BSCNAME,ManagedElement=BSCNAME,BscFunction=1,BscM=1,
GeranCellM=1,G eranCell=CELLNAME,PowerControl=1,PowerControlUplink=1 cmedit get
SubNetwork=ONRM_ROOT_MO,SubNetwork=AXE,MeContext=BSCNAME,ManagedElement=BSCNAME,BscFunction=1,BscM=1,
GeranCellM=1,G eranCell=CELLNAME,PowerSavings=1
CHGR & HCS CLI CMDs
cmedit get
SubNetwork=ONRM_ROOT_MO,SubNetwork=AXE,MeContext=BSCNAME,ManagedElement=BSCNAME,BscFunction=1,BscM=1,
GeranCellM=1,G eranCell=CELLNAME,HierarchicalCellStructure=1 cmedit get
SubNetwork=ONRM_ROOT_MO,SubNetwork=AXE,MeContext=BSCNAME,ManagedElement=BSCNAME,BscFunction=1,BscM=1,
GeranCellM=1,G eranCell=CELLNAME,ChannelGroup=1
cmedit get * GeranCell.(gerancellid==CELLNAME),channelgroup.(*) –t
cmedit get
SubNetwork=ONRM_ROOT_MO,SubNetwork=AXE,MeContext=BSCNAME,ManagedElement=BSCNAME,BscFunction=1,BscM=1,
Bts=1,G12Tg=27
0 cmedit get *
G12Tg.(g12TgId==270,rsite)
Mobility & Cell Relation CLI CMDS
cmedit get
SubNetwork=ONRM_ROOT_MO,SubNetwork=AXE,MeContext=BSCNAME,ManagedElement=BSCNAME,BscFunction=1,BscM=1,
GeranCellM=1,G eranCell=CELLNAME,GeranCellRelation=NBRCellname cmedit get
SubNetwork=ONRM_ROOT_MO,SubNetwork=AXE,MeContext=BSCNAME,ManagedElement=BSCNAME,BscFunction=1,BscM=1,
GeranCellM=1,G eranCell=CELLNAME,Mobility=1 cmedit get
SubNetwork=ONRM_ROOT_MO,SubNetwork=AXE,MeContext=BSCNAME,ManagedElement=BSCNAME,BscFunction=1,BscM=1,
GeranCellM=1,G eranCell=CELLNAME,Mobility=1,InterRanMobility=1 cmedit get
SubNetwork=ONRM_ROOT_MO,SubNetwork=AXE,MeContext=BSCNAME,ManagedElement=BSCNAME,BscFunction=1,BscM=1,
GeranCellM=1,G eranCell=CELLNAME,Mobility=1,LocatingFilter=1 cmedit get
SubNetwork=ONRM_ROOT_MO,SubNetwork=AXE,MeContext=BSCNAME,ManagedElement=BSCNAME,BscFunction=1,BscM=1,
GeranCellM=1,G eranCell=CELLNAME,Mobility=1,LocatingPenalty=1 cmedit get
SubNetwork=ONRM_ROOT_MO,SubNetwork=AXE,MeContext=BSCNAME,ManagedElement=BSCNAME,BscFunction=1,BscM=1,
GeranCellM=1,G eranCell=CELLNAME,Mobility=1,RadioLinkTimeout=1 cmedit get
SubNetwork=ONRM_ROOT_MO,SubNetwork=AXE,MeContext=BSCNAME,ManagedElement=BSCNAME,BscFunction=1,BscM=1,
GeranCellM=1,G eranCell=CELLNAME,Mobility=1,LocatingIntraCellHandover=1 #Mobility Parameters for External defined Cell
cmedit get
SubNetwork=ONRM_ROOT_MO,SubNetwork=AXE,MeContext=BSCNAME,ManagedElement=BSCNAME,BscFunction=1,BscM=1,
GeranCellM=1,G eranCell=CELLNAME,ExternalGeranCellRelation=Cellname cmedit get
SubNetwork=ONRM_ROOT_MO,SubNetwork=AXE,MeContext=BSCNAME,ManagedElement=BSCNAME,BscFunction=1,BscM=1,
ExternalGeranCel lM=1,ExternalGeranCell=ExternalGSMcellname cmedit get
SubNetwork=ONRM_ROOT_MO,SubNetwork=AXE,MeContext=BSCNAME,ManagedElement=BSCNAME,BscFunction=1,BscM=1,
UtraNetwork=1,E xternalUtranCell=ExternalUtranCellname cmedit get
SubNetwork=ONRM_ROOT_MO,SubNetwork=AXE,MeContext=BSCNAME,ManagedElement=BSCNAME,BscFunction=1,BscM=1,
GeranCellM=1,G eranCell=CELLNAME,Mobility=1,InterRanMobility=1,EUtranFrequency=38750
cmedit get
subNetwork=ONRM_ROOT_MO,SubNetwork=AXE,MeContext=BSCNAME,ManagedElement=BSCNAME,BscFunction=1,BscM=1,
GeranCellM=1,G
eranCell=CELLNAME,Mobility=1,InterRanMobility=1,UtranFddFrequency=3037
Start an inventory 3GPP data export job
Run the following command to export in 3GPP format, hardware and software data.
shm export
Note: this will export all inventory
You can also use:
• shm export -hw: to export in 3GPP format, only hardware inventory data
• shm export -sw: to export in 3GPP format, only software inventory data
• shm export -lic: to export in 3GPP format, only license inventory data
Check progress of export job
Use the job ID, checking inventory export command response
And run the command:
cmedit export -st --job #no
Where #no is the Job ID
Download the results of export job
Download the Generated Export File
You can download the file:
1. Using any FTP Client you want (like for example Filezilla). Just check the path under “File name” field of Job Status.
In this case, you can search for your files at:
/ericsson/batch/data/export/3gpp_export/
Tip: If you haven’t renamed it, it starts with “export_INVENTORY”.
2. Or you can download it via browser.
For this, simply run the command:
cmedit export -dl -j #no
This command will download the export file to the client browser