100% found this document useful (1 vote)
288 views

Focus PRO PLUS

Uploaded by

Dany Saputra
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
100% found this document useful (1 vote)
288 views

Focus PRO PLUS

Uploaded by

Dany Saputra
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
You are on page 1/ 62
FC-7688 Plus User Manual Oe Read this instruction thoroughly before installation and use of this device. P/N: 20190118B01 FC—7688 Plus Wiring Diagram fot SIM CARD L GSMantenna base RF antenna base 4 Vi $ ee 1 im s eae 6 — | on ; = —, — 2 2 a 5 3 z BUS module 22K 22K «TOK TK «WOK 22K 22K 20K 3 : Sy iren 3 Aux power wee ve Keypad Power supply 15VDC3A switch power >Only can use 12VDC 7Ah sealed lead-acid battery, change battery every 3-5 years. With 1 keypad, power consumption 250mA, support working for 16 hours *XTotal power consumption (keypad, auxiliary power, siren) can't exceed max. power consumption of control panel %Max. rechargeable current of battery: 350MA >kWhen using a wired or bus zone, you need to set the zone attribution in the zone attribution settings Warning: Please insert SIM card before installation, then power on FC-7688 Plus Expansion Module Description Wiring instructions DIP switch — Power Indicator Zone status indicator 4 lf © a> 9 TOM a BCom CM tH GM TH EGND { VETTE He ‘ Light Power indicator: always on when power is on; Zone status indicator: Zone is enabled and flashes slowly when normal When the zone is faulty, it always lights up. Dialing code description Please dial the code according to the table below. Keypad# | DIPSW#] Zone# | Keypad# | DIPSW#| Zone# 1 1010 ERB] | 41-48 7 1101 Fg] | 89-96 2 onto FB] | 49-56 8 0011 Fg] | 97-104 3 1110 EER] | 57~64 9 1011 fea] | 105~112 4 |0001 FEB) | 65~72 10 | o1t1 Fm) | 113~120 5 1001 FEB] | 73-80 "1 1111 Epp) | 121~128 6 o101 Ff] | s1~s8 Content FOREWORD- FEATURES: a LED INSTRUCTION OF CMS NETWORK. INSERT SIMCARD: ------ REMOTE PHONE CONTROL ----- : TAKE ALARM CALL FROMALARM PANEL. ------ GSMALARM PHONE CALL PICK UP- GSM SMS REMOTE CONTROL- FC-7601 BUS ZONE EXPANDER MODULE APPEARANCE INSTRUCTIONS: --------- WIRING INSTRUCTIONS: -- +--+ +--+ +++ KEYBOARD DIALING. FUNCTION BUTTON: - LED LIGHTS- COMMON OPERATION: DURESS PASSWORD: ARM/DISARM ALARM PANEL: ALARM PROCEDURE SYSTEM MAINTENANCE: +--+ +2000 |. SYSTEM SETTING: -- +--+ +> 1. SET SYS PASSWORD: - . 1.1 SET ADMIN CODE. :------ 4.2 SET MAIN USER CODE: 4.3 SET USER CODE: - 2.SYSTEM NETWORK SETTING 1 SET DHCP-: +--+ SET GATEWAY: - SET SUBNET MASK: SET DNS- . CMS- PHONE ALACENTER- . 1.1 SET CMS LINE 1-- . 1.2 SET CMS LINE 2- . 1.3 SET ACCOUNT: -~ . 1.4 SET DIAL TIMES: +--+ esses NETWORK CMS - . eBryryynn Jaaon VOwoww 3. 2.1 SET SERVER IP----- 2.2 SET SERVER PORT: - 2.3 SET CMS ACCOUNT T VOICE PHONE: +++ +--+ Cee E . 1 VOICE PHONE 2 PHONE DIAL TIMES: - ET SYS OPTIONS 1 SYSTEM TIME: 2 ENTRY DELAY: +--+ +--+ 3 EXIT DELAY: - 4 BELL TIME: 5 FORCE ARM- 6 EMERGENCY TONE: 7 AC POWER OFF DELAY 8 DOOR SENSOR CHECK: 9 WLS SENSORLOSS:::-:- ET WIRELESS- SET REMOTE: ---- nee 1.1 ENROLLREMOTE: --- 1,2 ENTER REMOTE CODE: 1.3 DELETE REMOTE: -- SET WLS DETECTOR: -- 2.1 ENROLL DETECTOR: . 2.2 ENTER CODE:---------- 2.3 DELETE DETECTOR SET WLS SIREN: -- 3.1 ENROLL SIREN: - - 3.2 DELETE SIREN: -- 6.4 RF SWITCH 6.4.1 ENROLL SWITCH: 6.4.2 ENTER SWITCH CODE 6.4.3 DELETE SWITCH: . 7. SET SYSTEM ZONE: -- 7.1 SET ZONE TYPE: - 7.2 SET ZONE SIREN: - 8. SET SYSTEM AREA: -- - 8. 1 PASSWORD AREA: - 8. 2 KEYPAD AREA’ - 8.3 REMOTEAREA: -- o POAAAAAAAAAVHRAH RPMYPMBNOIH 8.4 ZONEAREA**-- 8. 5 VOICE PHONE AREA Q.SETOTHER: s+: tess eee e eee e es Il. WEB IE SETTING 1. REMOTE CONTROL: ------ : 1.1 SYSTEM AREA STATUS. - 1, 2 SYSTEM ZONE BYPASS: - 1.3 SYSTEM STATUS: ----- 2. PASSWORD SETTING. -.--- - 2. 1 WEB LOGIN PASSWORD: 2. 2 ADMIN PASSWORD SETTING 2. 3 USER PASSWORD SETTING B.CMS: tts sc nett teens svete teens 3. 1 PHONE CALLED ALARM RECEIVING CENTER 3. 2 NETWORK CALLED ALARM RECEIVING CENTER: - - NETWORK SETTING: . 02 et ee cceeeeet tee v seen e ee 4.1 DEVICE NAME SETTING- settee ee 4. 2 NETWORK SETTING. 4.3 WEB PORT: : 5. SYSTEM OPTIONS: * 5.1 SYSTEM SETTINGS 52PGMi rte e eee tte e eee e ee eee beeen 6. ALARM RECEIVING BY USERS- settee : 6. 1 VOICE PHONE: fete e tees 6.2 PHONEAREA: - --- 6. 3 PHONE CONTROL PLATFORM- 7.WIRELESS DEVICE-------- 7.1 WIRELESS REMOTE CONTROLLER 7.2 WIRELESS DETECTOR: +--+ 0000s reer eres 7.3 WIRELESS SIREN 8. ZONE ATTRIBUTION 8.1 ZONEATTRIBUTION: ----- 8. 2 KEYPAD AREA INVOLVED 8.3 ASSOCIATED ZONES: - - - 8.4 WIRE ZONE LOOP 9. EVENT LOGS: -------- 10. REMOTE UPGRADE: 11. SYSTEM REBOOT: - 11. 1 SYSTEM REBOOT > 11. 2 SET BACK TO FACTORY DEFAULT: - «++ 12. ALERT SETTING 12.1 ALARM EVENT 12, 2 ERROR DISPLAY SETTING. 12. 3 GSM MODULE AND APN SETTING - 13. TIME SETTING: : 13.1 SYSTEM TIME: :-- 13. 2 TIMING ARM/DISARM 14. SMART HOME: -::-- . TECHNICAL SPECIFICATION: +++ 00s 0e eee eee REGULAR TEST. LIMITATION OF THE PRODUCTS: «+ +000 0220 CES manual Foreword FC-7688 Plus is a intelligent alarm control system which integrated with burglarproof, fireproof, gas leak proof. Itis compatible with wired and wireless alarm mode. FC-7688 Plus refers to the most advanced coding technologies of BUS zone and multi-bit random code-hopping technologies in security & reliability , to avoid false alarm and interference effectively . FC-7688 Plus support SIA2013 and CID protocol. This system is widely used in residence community villa, shops, offices. More information please carefully read the user manual. Warning: Don't disassemble or modify, or else maybe lead to danger and the damage of panel Don't put other things into the panel, metal, water and combustible materials easily cause short circuit or fire 3 Be sure not to cause to break by failing or throwing down or strong impacting. > Not install near the magnetic field, may cause instability. Keep dry and clean. Don't install the panel in the site which has oily fume, water-vapour, much poudre Be keep out of sun and heat. Don’t install the panel near the heating stove etc. high temperature equipment, such as spotlight. Keep out of the direct sunlight, may cause color fading. When cleaning, wipe with the mull. To remove dirt need to use detergent. > Don't use gasoline or paint thinner etc. chemicals. or else may cause danger or the paint scaled off the panel. Cee manual FEATURES Can set 4 separate area, 32 wireless zone, 8 wired zone, 88 bus zone expandable. Totally support 128 zones. Support 1 admin password, 1 master user password, 32 user password, WEB log-in password. «Support 8 remotes, 4 bidirectional wireless keypad, 8 wired keypad, 32-way radio switch Support 2 network CMS platform, 2 CMS phone #. Can set backup mode , both-report mode Support 4 follow-me phone # for voice phone call and SMS message Support APP remote control Timing arm and disarm: 2 groups of time arm and disarm time, you can assign any one or several partitions effective; LED INSTRUCTION OF CMS NETWORK LED OFF—Network disconnect Slow flash—GPRS connected or LAN network disconnected. The flash speed under LAN NETWORK offis slower than GPRS connect Quick flash: internet connect INSERT SIM CARD: The telephone card is Micro SIM. => CZ A. Push backwards the SiMcard i j lid and pull up. holder B. Insert the SIM card C. Cover the lid well MEG SCS REMOTE PHONE CONTROL Di7Di~ e » oO») ») ©) you wi hear: > Enter password The alarm panel take the phone call User call the phone # | after finish 7 times ringing(factory ofthe alarm panel default is 7 times) a —~ an ® 4) Press 1 to arm area 8 (1\(2)3)/4) Press 2 to disarm area >» Press 3 to stay area Press 4 to check area status Pls enter the user password 1234 (factory default) Press 0 to hang up TAKE ALARM CALL FROM ALARM PANEL The alarm panel will call the user when alarm happens. see below diagram. Door sensor send Alarm panel make User pick up the alarm signal ) alarm call alarm call You will hear below voice guidance @) | on the phone call. Press 1 to cancel alarm Press 2 to inquiry alarm event » | Press 3 toarmarea Press 4 to disarm area Press 5 to stay area Press 6 to enable siren Press 7 to disable siren __ Press 0 to hang up WG —CSS GSM ALARM PHONE CALL PICK UP When alarm happens , the simcard in the alarm panel call the follow-me phone # You will hear the below voice guidance: Press 1 to cancel alarm Press 2 to inquiry alarm event Press 3 to arm area Press 4 to disarm area Press 5 to stay area Press 6 to enable siren Press 7 to disable siren Press 0 to hang up GSM SMS REMOTE CONTROL Arm command: Enter the sms command on phone |#PASSWORD:1234#ARMED AREA X(X=1--4) Disarm command: Enter the sms command on phone |#PASSWORD:1234#DISARMAREA X(X=1--4) Stay arm command: Enter the sms command on phone |#PASSWORD:1234#STAY AREA X(X=1--4) Note: X is the area #, from 1 to 4. Default use password 1234(no space). You will receive a reply sms message if the panel accept and proceed your SMS command. 7601 BUS ZONE EXPAND MODULE 1+(1+16)=18 ON 64 32 16 i SRR PSA 1.FC-7601 is DIP-type single address code zone module, the resistance is 10K 2.The module extends the address range 1-128. 3. Wiring: Red DC+, Brown DC- , Yellow RS487a, White RS487B, Green(ZONE TEST), Brown Cable IS GND. 4, WORK VOLTAGE: dc8.5-24v 5.DIP 1, tamper checking switch, ON tamper checking on, OFF tamper checking off 2-8 address code. OFF enable, ON disable. Count by Binary. Example address 18, set DIP 4 and 8 OFF, All address plus 1. See the above diagarame. 6.Bus zone 41-128 is disable as default.pls enable it before using. V+ Vs COM No v+ Vv; CoM Ng TMP TMP @ © RS487A t Ricto? RS487A RS487B [RS487B Red Brown Green Yellow White Red Brown Green Yellow White FC-7601 FC-7601 Single zone module Single zone module NO TAMPER TAMPER Sie. manual APPEARANCE INTRODUCTION Front view WIRING INSTRUCTIONS Please follow the wiring diagram below to connect. Normally loved Host 8 2 ‘ ett fk R 2 ston port np. 23 port KEYS} com Touch keyboard connection port KEYBOARD DIALING There are 4 DIP switches on the keyboard, which can set 8 keyboard address codes, Black represents the position of the switch, as shown in the figure to the right: Note: The keyboard factory defaults to the No. 1 keyboard. When using multiple keyboards, each keyboard is connected in parallel with the host connection port. The dialing address of the keyboard cannot be duplicated, and the corresponding keyboard must be enabled in the host's engineering settings. Unused keyboards should be disabled. Otherwise, the response speed of the keyboard will be offected. When all the keyboards are inadvertently deactivated, the system will automatically enable the #1 keyboard, Terminals ;——LcCD LED Touch keys DIP switch— >| Rear view ____ Normally opened 3: fai on And oN 2 eno Sal]: 2 KEY com Touch keyboard connection port KojboarsNo] DIP switch] Zone 1 Fel | «2% 2 Ge | sas 3 FE] | 474849 4 Ee] 50 51 52 5 i 6 FRA] | 565758 7 FE] | se 606 8 = WG CS FUNCTION BUTTON Icon Meaning Instructions _ The button can set arm multiple partitions at one time, and can @ Arm also arm individual partitions separately.Press and hold for = 3 seconds for emergency alarm, - The button can set multiple partitions to stay status, and can @® Stay also set stay on a single partition.Press and hold for 3 seconds for medical care = The button can disarm for multiple zones ,or disarm the @® Disarm individual zones individually. Press and hold for 3 seconds for fire alarm ‘Area With Arm, Disarm, Stay to operate on a single Area. Uparrow | Select upward Down arrow | Down select retumkey | Return to previous menu/exit menu Enterkey | Enteroptions Icon Meaning Instructions ‘On normal power supply; Power Flash - AC power failure; Indicator | Slow flash - battery failure; Off - AC and battery failure On - all partitions in the Nn management area; a vileate Flash - partition alarm; inaicator | Slow flashing - Partial arming and disarming of managed zones On - all administrative divisions are disarmed; Flash - The zone of the managed zone is faulty. a Disarm Slow Flash - Partition Zones Managed By Bypass indicator On - configuration parameter check error, Flash - platform connection and communication failure; 8) : (2) | Fauttincicator | Siow ash - network, GEM, PSTN failures; Off - No failure Wie —C(CS Support 8 keypad. Pls scan and add keypad after repower the alarm panel The keypad will not work if add without repower the alarm panel, in this case, you can re-scan to add the keypad on a keypad which already work by the command admin PW[012345]*9#. Each keypad is with a different address. The first time connect the keypad, it will display fault event. Like battery problem, network problem etc... , you can choose the event to display on WEB MENU. COMMON OPERATION Default admin password is 012345, main user password is 1234 Enter admin program menu:[012345]+|%* )+[0]}+ # ) Alarmevent: Press | @_) to inquiry under standby status Enter bypass zone: [1234]+ | w ) Once azoneis bypassed, the keyboard displays the bypassed zone. You Can only bypass the zone in the area which control this this password. At the same time only allow ONE keyboard to enter the bypass settings. However, if you enter a higher privilege request, it will exit the bypass setting if you enter the system settings. DURESS PASSWORD User password/admin password+[0]+ ( )/ / & When you enter the duress password, you will trigger an duress alarm. If enter duress password When the system is under arm status, keypad will display system is disarmed, stop siren but send alarm info and alarm call (pls set the CMS phone # and follow me phone #) Example, A arm the system, B enter the area and trigger alarm, B threaten A disarm the system. A enter the duress password. The alarm panel will show disarm status but will send alarm info can call AREA X DISARM 2018-01-05 15 :30 Enter Duress Password Sie. manual ARM/DISARM ALARM PANEL yeArm é I AREAX ARM 8 AREAX DISARM oO 2018-03-25 15 :30 2018-03-25 15 :30 Corresponding user password +h )| | CoFresponding user password + P 9 pe a or by pressing the disarm button of the or press disarm button remote control (corresponding remote control. © Pani \ ~ ¥e Panic alarm = ¥ Stay a i ( (eS (Ce AREAX ALARM 2018-03-25 15:30 hE AN STAY, Press and hold for or press the ©, ore Corresponding user password+ @ )) “emergency” button on the remote control! for emergency help. Press and hold for to achieve “fire alarm" or press the home security button of (the corresponding remote control The code of different ARM/DISARM operation BY remote, 8 remote code is 141-148 By user password, 16 user password is 01-32 By phone call, 4 follow me phone #is 160-164 By CMS platform, code is 150 By arm/disarm schedule or key zone: code is 165 By WEB IE menu, code is 155 By Phone APP, code is 166 Unknown 90 CSc manual ALARM PROCEDURE Telephone Telephone Call phone m = a tt +t +f 2nd 3rd 4th 3. when the alarm panel starts the alarm, it will dial the area phone # by preset call times. If the number of alarms is multiple, it will start cycle alarming by the second and third steps > & Ss Alarm situation found, starttosendmessage |, 1)> Gotector | activated send alarm information to alarming 110 alarm center 2.The panel use Ademco Contact ID to send alarm information to alarming center. f the panel got confirmation from center,then alarm successfully. Otherwise, the panel will repeat alarm.The alarm information will be display and reslove by the alarm center computer software.At the same time the alarm panel can also send alarm information through the Internet network to the alarm management platform, by the management software for display and alarm processing Ei eae SYSTEM MAINTANCE Pls make the below test before installation. Communication test: main user password+*1#; battery test: main user password+*2#. Siren test: main user password+#*3# Walk test: main user password! *4# (disarm all area before start walk test) 1)Communication test: test the communication between alarm panel and CMS. Main user password+ % ) +[1]+| # )—> CMS will receive timing test report message 2)Battery test Main user password+| ¥%& )+[2]+ # )—*5 mins after CMS will receive battery status message You can not start the alarm panel with only battery connect. But trigger the battery by AC power first.One battery test take about 4 mins, so, it will take at least 5 hours to report battery recover. When AC power is normal, battery test proceed every 24 hours. If battery disconnect, it will test battery every 10 mins. When battery voltage is low, it will test battery every 60mins. When AC power trouble, it will test battery every one minute. 3)Siren test: test the communication between siren and alarm panel Mainuserpassword+ 4 )+[3]+, # ) -*» trigger siren—>siren sound 4) Walk test example: walk test at zone 8 [1234] +(e )+[4j+( # ) >. Walktest: 000 : + trigger zone 8 walk test mode zone alarm: 008 press @ ) back to standby interface > WG ——CS |. SYSTEM SETTING (+ 1.SET SYS PASSWORD > 2.SET SYS NETWORK |» 3.SET CMS [> 4.SET VOICE PHONE [012345]+ % )+[o]}+| # ) —————> | +5 SET SYS OPTIONS > 6.SET WIRELESS | 7.SET SYSTEM ZONE |» 8.SET SYSTEM AREA |» 9.SET OTHERS Note: only in disarm status, user can do system setting. 1.SET SYS PASSWORD 1.SETADMIN PWD [o12345]+ *& )+o}+ # )+ # —+ La sermainuser wo ‘+3.SET USER PASSWORD The central panel has one admin password, one main user password, 32 user password and Web login password. password can control one ormore system area The password’s right on keypad is decided by the system area the password can control and the system area the keypad can control For example: fuser sets password No. 6 can control area 1, 2, 3, the keypad No. 5 can control area 3,4 password No.6 can Then the user can only control area 3 on keypad only control area 3 No. 5 via password No. 6 1.1 SET ADMIN PASSWORD Admin password has the highest authority. E.g, set admin password as 55555 Sie manual [012345])+ %* )+[o}+ # )+ # )+ # ) —> ‘ENTER PassWvoRD Eeaxx “Lcd displ: +(55555]+| # ‘splay The keypad will beep twice to confirm the password has been changed 4+ > 4)+) # ) Backto standby interface Tips: if forget admin password or web login password, please follow: Power off the central panel, and power on again, within 60s, enter 000000 as password to operate and set new password 1.2 SET MAIN USER PASSWORD Please refer to user setting | 1.3 SET USER PASSWORD E.g Set user password no. 03 as 0000 [o12345]+ *& )+oj+ # )+ # )H13+ # —> ae ci a LGD dispiay “ENTER PASSWORD : ENTER PASSWORD#: [i +[o3]+ + Eaexx +[o000]}+ # > wea) “LCD display’ "* “LED display” * The keypad will beep twice to confirm the password has been changed. After this, the keypad will enter to set next password no. , press 4+ 4+ + EF ) back to standby interface 2.SET SYSTEM NETWORK 771] SET DHCP 2] SETIP [012345])+ * )+[oj+| # )+[2]+ # ) —+}+3]SET GATEWAY 4] SET SUBNET MASK 5] SET DNS 2.1 SET DHCP User can choose to enable or disable DHCP function.Eg. Enable DHCP function WG CS “LED display ©” +[21+ # The keypad will beep twice to confirm it has been changed, the keypad will return to previous setting Press’ @ )+/ @ )+( #_ ) back to standby interface. 2.2 SETIP. Factory default IP: 192.168.1.200 Tips : If DHCP is enabled, then it is not able to set IP here. E.g. Set IP as “192.168.1.81", we need to enter “192168001081” in the keypad. User need to add “0” to make 3 digits if not enough.After set, please power off the central panel and restart to make the IP effective [012345] + )eo+ # )+ (2+ # )+2+( #F > bh0. o00. 600, 000 LCD display +[192168002081]+ # The keypad will beep twice to confirm it has been changed, the keypad will return to previous setting.Press (000. 000, 000, 000 LCD display +[255255255000]+ # The keypad will beep twice to confirm it has been changed, the keypad will return to previous setting.Press. q )+ €)+ # ) back to standby interface. 2.5 SET DNS E.g. Set DNS as 202.96.128.85 ENTER DNS SERVER: [012345]+ * )+[o]+ # )+(21+) # )+I51+ # )— 00 000. 000, 000 “LCD display +[202096128085]+| # The keypad will beep twice to confirm it has been changed, the keypad will return to previous setting.Press SET CMS LINE 1 -+2>SET CMS LINE 2 fo12345) + & Jeo # tis +H eee counT +4>ENTER DIAL TIMES Sie. manual 3.1.1 SET CMS LINE 1 When alarm is triggered, the central panel will dial CMS telephone No to inform the central monitor server. It can support to set 18 digits maximum E.g. Set Set CMS line as 800012345 [o12345]+ *& )+o}+ # )+I3]+ # )+ #)+ # —» CMS PHONENO.:(40EL): .189912345]+ # ) LCD display The keypad will beep twice to confirm it has been set, the keypad will return to. previous setting.Press_ ie a +[0001]+ #) LCD display The keypad will beep twice to confirm it has been set, the keypad will return to previous setting.Press_ (01-10) +108)+ # ) LCD display The keypad will beep twice to confirm it has been set, the keypad will return to previous setting.Press )+ 4 )+ € )+ # )backto standby interface. Sie. manual 3.2 NETWORK CMS [012345)+| He )+[o}+ # )+(3]+ # )+21+) # 1>SET SERVER IP a peser SERVER PORT 3>SET CMS ACCOUNT -+4>SET CMS PASSWORD 3.2.1 SET SERVER IP Set CMS IP as 014.152.090.065 [012345]+ * )+oj+ # )+(3]+ # )+21+ # )+) # | SERVER IP. ~ +[014152090065]+, # 00.000.000.000 LCD display The keypad will beep twice to confirm it has been set, the keypad will return to previous setting.Press (q )+ The keypad will beep twice to confirm it has been set, the keypad will return to previous setting.Press. 1]VOICE PHONE 1 -+2]VOICE PHONE 2 (o12345]+ & )+[o]+ # )+[4]+\ # ) —» +3]VOICE PHONE3 + 4]VOICE PHONE 4 + 5]PHONE DIAL TIMES 4.1 VOICE PHONE When alarm happens, the device will dial to user's phone no. Automatically. Itcan set 4 phone no maximum, each phone no. supports 18 digits maximum E.g. Set voice phone no.2 as 88776655 (o12345]+ *& )+oj+ # )+i4)+ # )+(2+ # —> VOICEPHONENO."DEL: . Ig9776655] + #) LCD display The keypad will beep twice to confirm it has been set, the keypad will return to previous setting.Press +5] FORCEARM +6] EMERGENCY TONE +7] AC OFF DELAY +8] DOOR SENSOR CHECK +9] WLS SENSOR LOSS 5.1 SYSTEM TIME E.g. Set system time as Oct, 1st, 2017 23:59:59 [o12345]+ * )+[o}+ # )+I5]1+| # )+ # ENTER SYSTEMTIME (17 1001235959] + # ) 20-01-01 12: 00: 30: YMDHMinS LCD display The keypad will beep twice to confirm it has been set, the keypad will return to previous setting.Press. q )+ +([20)+ # (000--255)S Po] LCD display The keypad will beep twice to confirm it has been set, the keypad will return to previous setting.Press 1>DISABLE 2>ENABLE ++ # LCD display The keypad will beep twice to confirm it has been set, the keypad will return to previous setting.Press r+ [2] + “>MUTE —_2>SOUND (2) # LCD dispiay The keypad will beep twice to confirm it has been set, the keypad will return to previous setting. Press + [005] + (000--999)M 0 DISABLE {005} # “LOD display The keypad will beep twice to confirm it has been set, the keypad will return to previous setting.Press| q )+ +[2)+ # “ >DISABLE 2>ENABLE . * [71 LCD display The keypad will beep twice to confirm it has been set, the keypad will return to. previous setting.Press i+[04)+ # (00--99)H__Odisable (04) LCD display’ The keypad will beep twice to confirm it has been set, the keypad will return to previous setting.Press_ 1)ENROLL REMOTE [012345] + ye )+0l+ # )+[6]+ # J+ # )—>—2ENTERREMOTE CODE —+3)DELETE REMOTE 6.1.1 ENROLL REMOTE Example: enroll remote to the #2 remote in alarm panel [012345] + xe )+[0]+ # )+(6]+ # )+ # )+ # > -ENTERREMOTE#: HI: . 12) (GF) + | TRIGGER WLS DEVICE : -8) LCD display LCD display :DEVICE WIRELESS CODE: ENTER REMOTE#: EI: + @, . wn- : ~B :_ 226016063 + # (1-8) LCD display" “"""LeD display” The keypad will beep twice to confirm it has been set, the keypad will return to previous setting.Press_ psn UCD display” “6D display +[226016063]+( # )—> ENTER REMOTE: BL "LSD display The keypad will beep twice to confirm it has been set, the keypad will return to previous setting.Press (4-8) 0 DELETEALL : * [9 # LCD display LCD display 1H The keypad will beep twice to confirm it has been set, the keypad will return to previous setting.Press' q )+ q@ )+ 4 )+ # ) back to standby interface. Note: enter 0 to delete all remotes 6.2 SET WLS DETECTOR + 1)ENROLL DETECTOR [012345] + 4 )+[0]+ # )+[6)+ # )+I2]1+ # )—>+ ENTER CODE > 3) DELETE DETECTOR 6.2.1 ENROLL DETECTOR Example: enroll detector to #2 detector in the alarm panel [012345]+ ye )+[O]+, # )+[6]+ # )+l21+ # )+ #) ENTERDETECTOR#: BH, (99) 4 Gf) _» ; TRIGGER WLS DEVICE (01-32) q LCD display LCD display "DEVICE WLS CODE: ENTER DETECTOR #: OB: > i > 2129110107 + #32) ; LCD display LCD display Trigger detector The keypad will beep twice to confirm it has been set, the keypad will return to. previous setting.Press_ SER Oe &: “Leb display” The keypad will beep twice to confirm it has been set, the keypad will return to previous setting.Press| : LCD display LCD display FENTER DETECTOR #: [OK +) > © ors2) oo det AL LCD dispiay The keypad will beep twice to confirm it has been set, the keypad will return to previous setting.Press | )+ @)+ << )+ # ) backtostandby interface. 6.3 SET WLS SIREN (012345) + 4 )+Ol4 # )+le]+ # )+t31+ TH ENROLL SIREN 2)DELETE SIREN Note: the keypad will display fault if not connecting the wired siren. User could connect 2.2k eol resistor at bell terminal if without wired sirens. a WG ——CYS 6.3.1 ENROLL SIREN Example: enroll siren to #2 siren in the alarm panel [012345] + 4 )+[0]}+ # )+(6]+ # Yt # d+ FY : ENTER SIREN #: a "SIREN IN PROGRAM, +[2]+) #)s> 1a "I TO START CODING LCD display LCD display CODING... ‘= Press save button LCD display in the siren ae wee T ENTER SIREN #: ~] : f 1-4) p [DEVICE WIRELESS CODE: , 9) 1302065412 + # LCD display LCD display The keypad will beep twice to confirm it has been set, the keypad will return to previous setting.Press j LED dispiay LCD display ENTER SIREN #: + )> # (4-4) 0 DELETE ALL LCD display The keypad will beep twice to confirm it has been set, the keypad will return to previous setting.Press | 1)ENROLL SWITCH [012345] + )+10]+ HF )+l6l+ # )+14]+ #_)->- VENTER swiTcH CODE L. 3)DELETE SWITCH 6.4.1 ENROLL SWITCH Example: auto the wireless switch to the #2 switch in alarm panel [012345] + 4 )+0]+ # )+i6]+ # )+i4l+ #)+ # ENTER SWITCH#: [it ¥#F) TRIGGER WLS DEVICE (01-32) + (021+ # J > LED dispiay LCD display > ENTER SWITCH#: + #)>: (01-32) Trigger electrical switch LCD display The keypad will beep twice to confirm it has been set, and the keyboard will automatically enter the next wireless switch after completion. Press )+ 4 )+ 4 )+ # ) back to standby interface. 6.4.2 ENTER SWITCH CODE Example:add a wireless switch code of 122095110 to No. 3 in alarm panel [012345] + 4 )+0]+ # )+l6l+ # )+i4l+ # J++ # ENTER SWITCH#: GH: , (03])+ #) > ae DEVICE #: (01--32) “""'UGD'dispiay 9" “LCD display ENTER SWITCH#: +[122095110]}+ # )—> (01-32) a LCD display The keypad will beep twice to confirm it has been set, and the keyboard will automatically enter the next wireless switch after completion. Press @ )+\ @)+ 4 .)+ # ) backtostandby interface. q TS raed 6.4.3 DELETE SWITCH Example: delete the #3 switch [012345] + 4 )+0]+ # )+l6l+ #F )+i4i+, F ) +314 # ENTER SWITCH#: [ih DELETE DEVICE + )— co1~32) 00 DEL ALL. * 031+ # LED dispiay LCD display ENTERSWITCH#: OH : # )— © (ot-32) 00 DEL ALL: LCD display The keypad will beep twice to confirm it has been deleted, and the keyboard will automatically enter the next wireless switch delete after completion Press @ )+ @)+ €)+\ # ) backtostandby interface. 7. SET SYSTEM ZONE y+ 1]SET ZONE TYPE [012345] + +[0]+ # )+(7]+) # lo l x) J 2]SET ZONE SIREN The zone can be assigned to one or more areas The common zones will not set off alarm if one of the assigned area is disarmed The common zones The common zones will not set off alarm will set off alarm When the common zones set off alarm, all users in related areas will receive notifications Expanded zone number is from no.40 on, expanded zones for bus zones only. Zone names editable. New edited names will be display on keypad and sms text notifications [User manta! 7.1 SET ZONE TYPE The options of zone types as below 0>DISABLE 1>DELAY 1 2>DELAY 2 3>PERIMETER 4>INTERIOR 5>EMERGENCY 6>24H 7>FIRE 8>WATER SENSOR attrigtons | Interior | Delay | Perimeter] 24Hours | Emergeny| Fire Alarm| Disable Away Arm v v v v v v x Home Arm, x v v v v v x Disarm x x x v v v x 1. “J” means the hub will give alarms is triggered 2.“ x” means the hub will not give alarms when the type of the alarm is triggered Example: Set Zone 8 to be fire zone. [012345] + 4 )+l0l+| # )+I7]+ # )+ #)>: aan a LOD display SELECT ZONE TYPE: ENTER ZONE: [09 = + + ) + } 008) + # J oS DISABLE (71+ # J (001--128) : LCD display LCD dispiay The keypad will beep twice to confirm it has been set, the keypad will return to. previous setting.Press. ‘ENTER ZONE: Mot | : SELECT SIREN TYPE: i (001-128) +[108] + # ) >: | conr asput.semure ; + [21+ LCD dispiay ~~ LCD display ENTER ZONE: flog: #)> (001--128) Leb display The keypad will beep twice to confirm it has been set, the keypad will return to previous setting.Press| ENTER PASSWORD. oh , +F "AREA: 1234 (*SEL) > :MANAGE:: BINNN “LCD display" ENTER PASSWORD#: [i +ow)t vt * St #)> (01--32) “LED display “7 The keypad will beep twice to confirm it has been set, the keypad will return to previous setting.Press ENTER KEYPAD #: HI, FA) AREA: 1234 (*SEL) (1-8) MANAGE: [NNN “Leb display” “UGB dispiay * ENTER KEYPAD #: Bl + #& +t k& )+| FE )> (1-8) LCD display The keypad will beep twice to confirm it has been set, the keypad will return to previous setting.Press| @ )+ @ )+ <€)+ # )backtostandby interface. 8.3 REMOTE AREA(default value is area 1) Example: set remote 1 to manage area 3. (012345) + w )+0l+ +) +(81+ # )+i3]+ # > ENTER REMOTE#: IAREA: 1234 (*SEL) + > + (1--8) : # "MANAGE: [JNNN * LCD display LOD display : ENTER REMOTE#: + vw) + w+ # ) +i G-8) ~ “""""" Vb display The keypad will beep twice to confirm it has been set, the keypad will return to previous setting.Press_ ENTER ZONE: [01 : +[055]+ #)> AREA: 1234 (*SEL) - : (000--128) MANAGE: [MNNN LCD display LCD display ENTER ZONE: [56 + Ow + Ov) + ® + F ) > 00--128) LCD display The keypad will beep twice to confirm it has been set, the keypad will return to. revious setting.Press + + + #- ) back to standby interface. LP 9. < < < y 8.5 VOICE PHONE AREA (default value is area 1) User can set 4 voice phone numbers, example: set voice phone #1 to manag area2 and area 3. [012345]+ ye )+[0]+ # )+(8]+ # )+[5]+ # )> VOICE PHONE + #)> AREA: 1234 (*SEL) (1--4) MANAGE: MANNN “""" LED display” LCD display VOICE PHONE: + k& )t ok lt & dt # > o. LCD display The keypad will beep twice to confirm it has been set, the keypad will return to previous setting.Press <€)+ # )backto standby interface. CES manual 9.SET OTHER Without voice prompt,programme address and the corresponding options as below: 002~ Ring Times 918-System Programming Changed 5 003-Communication Test Time 919-System Arm Failed 004-Telephone Line Test 920-Communication Testing 005-Wireless Detector Tamper 921~Zone Bypass 006-Arm/Disarm Siren Short Sound Tone | | 922~System Battery Recovery 007-CMS Heartbeat Time 923-System Communication Recovery 008-Web Port 924Zone Bypass Recovery 009- Limit of Alarming Times 925-System Communication Recovery 900-Delay Alarm 901—Perimeter Alarm 902-Interior Alarm 903-24 Hour Alarm 904-Emergency Alarm 905-Fire Alarm 906-SOS 907-Tamper Alarm 908-System Arm 909-System Disarm 910-Armed Stay 911-System Low Battery 912-System AC Loss 913-System AC Recovery 914-Alarm Cancel 915-Detector Battery Fault 916-Detector Battery Recovery 917-Wireless Detector Loss 926-Zone Loop Faulty 927-Zone Loop Recovery 928-Siren Faulty 929-Siren Recovery 930-Hijacking Alarm 931-Delay Recovery 932-Perimeter Recovery 933-Interior Recovery 934-Emergency Recovery 935-24 Hour Recovery 936-Fire Alarm Recovery 937-Emergency Recovery 938-Tamper Recovery 939-Wireless Detector Recovery 940-Telephone Line Fault 941—Telephone Line Recovery 900~999-SMS Setting MNSSSCD0DCDONNNOCOCOaMaaG aananannnanannrannrnnrn 1. 002-Ring Times (the default setting is 7 times) : set value 00-15 003-Communication Test Time: set value 0-999s. 004-Telephone Line Test: 1. Disable 2. Enable 005-Wireless Detector Tamper: 1. Disable 2. Enable 006- Arm/Disarm Siren Short Sound Tone: 1. No voice 2. Siren short sound 007-CMS Heartbeat Time: set value 0-9999s 008-Web Port: set value 0-65535 009-Limit of Alarming Times: 1. No limited 2. 3 Times Limited 2. #900-941 Alarm Event, the value above is factory default 3. Set Alarm event notification as below 0>Do not send any info. 1>CMS ONLY 2>Voice number only 3>CNStvoice number 4>SMS ONLY 5>CMS+SMS_ 6>Voice number+SMS_—_7>CMS+Voice number+SMS q WG CS I..Web IE Introduction Open the IE browse and input the IP address of the alarm control panel, please enter the user and password. Default user account is admin, and password is 012345. USER): PASSWORD: Open the Internet browse as below: Oi>s a % Note: Web IE Settings currently do not support RFID setting, Email setting and Smart home. TS. manual 1,.REMOTE CONTROL > Press the remote control icon } to enter below interface. 1.1 System area status: After selecting the system area status, the system prompts that the operation is succeessful. ‘System area status ‘System area 1. system area 2 ‘System area 3 ‘System area 4 1.2 System zone bypass: System default zone number 1-128 ,totally 128 zones Enter the zone number in the middle input field. In the right zone option, you can choose the zone bypass or cancel bypass ‘System zone bypass Zone 001-128: Zone bypass [= 1.3 System status: After the success of zone bypass setting , you can check the current system status in the system status. System status Number ZonelSystem /Area Status / Event 1 system AG power normal 2 system Battery fault 3 system Notwork normal 4 system GSM module fault 5 system Telephone line faut 6 system Siren faut 7 system (OMS network platform faut 8 system (OMS phone platform normal 9 ‘System FLASH CRC check normal Wii ——S 2.PASSWORD SETTING Press the password setting icon a to enter below interface. 2.1 WEB login password: Username and user password can be set up to 8 digits (include letters). When user changes username and password ,then clicks Save, the system will pop up the login window to log in again. 2.2 Admin password setting: Admin password is 6 digits. Master user pass- word is 4 digits. Enter new password and click Save. The setting interface will automatically reset to blank input. 2.3 User password setting: Password is 4 digits. You can set 32 user pass- words.Every user password can control 1-4 areas.For example, you can set pass- word NO.01 to control the Areat and Area 3. WEB login password Usemame: admin User password: Save ‘Admin password setting Installer password: Numbers ony Master user password: “Numbers only Save User password setting Password No.: LJ User password: * Non-numeric input will delete the password Password permission: | Areat | Area2 Area3- Aread Save Ei > 3.CMS Click icon - for CMS . 3.1 Phone called alarm receiving center: When you set alarm receiving phone, enter P and the dial will pause for one second. The default times of dialing is five times. When the alarm is triggered, the panel will call the alarm receiving center. Then, the panel will dial 1-2 telephone numbers as preset. If more than 2 numbers, the panel will start with the second telephone number, then 1,2 Phone called alarm receiving center Voice phone 1 ~ Paling pauso oprator ‘Voice phone 2 "Pang pune oprtor User No. [0000 Dialing times: 6 “0-75) Commuricaton testinal ime fo (0-906) 0.D0 not send mt repent Network called alarm receiving center ‘Alarm receiving server 1 114 152.90 56 “IP adress oF domain name Server 1 Pott irera Server 1 registered users 16000105 Server 1 registered PWD: eee Alarm receiving server 2 14.17 70.70 “IP adress or domain name Server 2 port [rane Server 2 Registered users: {9828711 Server2 Registered PWD: Heart beet time(S). po “(1 - $999)The maximum heartbeat time for ethernet is 180 seconds Message forwarding mode: © Backup mode © Dual way mode Save “Some Stings may need to restart the system 10 take etoct 3.2 Network called alarm receiving center: The message forwarding mode can be set to backup mode and dual way mode. On back up mode, the alarm information will upload to Server Address 1 in priority and Server Address 2 will wg Wii SCS be backup when Server Address 1 failed.On dual way mode, The alarm information will upload both Server Address 1 and Server Address 2. After setting, click Save. Then reboot. Y PANEL PANEL Backup mode Dual way mode {i ul 4. NETWORK SETTING Click @) icon for setting 4.1 Device name setting: Device name can be changed.But the MAC address can not be changed 4.2 Network setting: Check DHCP will automatically obtain the IP address, and the previous IP address is not available. The factory default IP address is 192.168.1.200.User need set IP according to local settings,can not use the same IP for several alarm panels. 4.3 Web port: The default is 80. After setting, please restart the system to take effect. Device setting MEIAN_PANEL Device name: “non anable DHCP. fia dowce name ‘onthe dovce MAC address: (00:00:12.91,0F:98 Network setting DHCP IP address: 192.168,7.80 Subnet mask 285.285.2550 Defauit gateway: 192.1687.1 Preferred ONS 202.96.128.86 Standby DNS: ssss Web port Web por oo *Neod io entre pot number ran browsar adress if default ports not 80 Save “you must estan your syst forth confguraon changes to take te Wii SCS 5.SYSTEM OPTIONS: Click icon 3g to system options settings 5.1 System settings 1> Entry delay is only for delay zones 2>Exit delay time: User need exit within preset time after system armed 3>Siren time: The alarm duration time after system alarm, default value: 2 minutes 4>Ring times: User phones remotely to operate the panel and dials the phone number on the panel,default value: 15 times 5>Wireless detector loss inspection: If the panel doesn’t receive status signal or alarm signal within preset time,the panel will regard the detectors as loss. 6>AC off report delay: When system AC power cut, user can set the delay time to report to alarm receiving center,default value: 30 minutes. 7>Arm/disarm tone: User can enable/disable arm/disarm tone when arm/disarm system via remote controller. 8>Emergency alarm siren type: When alarm, the panel is mute or ring,default value is mute. 9>Door contact inspection: When door/window is not well closed,the system will receive zone trouble information from door contact if enable door contact inspection. Default value:Disable 10>Force arm: When enable force arm, system still can be force armed when zones are in trouble ‘System options: Enty delay 1(Second) 16 “0-285) Entry delay (Second) 6 1-285) Exit delay 2(Second) 0 1-255) Siren times(S): {120 wey Ring times. A 50 -18)et nal is tineton ‘Wireless detector loss inspection @ 0. )Set Odea the etn (Hour) AC off reportiMinute) 5 50-96) ale is neon ‘Axmvidisarm tone’ Disable ss Emergency alam siren type Mute Door contact inspection Enable Ll Force arm Enable = Wis dtc ter seve I ‘3 times Zone alarm ties limit ct pa re gig tes Cratyouarm agen Phone tne inspocton: Deable || Quick an: ao S| Ertl Arming does nt hack pasovor Keyboard Panic Enable [=] “Ome Resmeretatonen RE Function Enable a Wii SCS and trouble zones will be bypassed automatically and system will send bypass information to alarm receiving center.When disable force arm,system can not be armed when zones are in trouble: Disable. 11>Wireless detector tamper inspection: default value: enable 42>Zone alarm times limit: If system is triggered more than once before system disarm or cancel alarm, the system will not alarm if user set zone alarm time as 1.Default value :3 times. 13>Phone line inspection: default value: disable. 5.2PGM When an event occurs, the programming output voltage changes from voltage 0V to 12V (the default follows the partition alarm output), and the trigger events can be set as follows: 1>Area alarm 2>Area fault 3>Area bypass 4>Area arm 5>Areastay 6>Areadisarm _7>Phoneline fault 8>CMS fault 9>AC off 10>Battery fault 11>Siren fault 12>Password control Output time: The voltage output time is 180 seconds when the default event is triggered PGM1 Assign PCM to Area: Pama! (area? | Arend Arend POM activated by: ae Oo time(Second): i aes L “(0 - 999)Set 0 Deactivated only when current status change. PGM2 Assign PGM to Area: T Area 1 Area 2 [Areas Area 4 POM activate by ‘Ava alarm = Output time(Second): lal “o-s2)se 0 oesemaeseny onan uenis naoe PGM3 Assign PGM to Area: Tawa! | Area? Area Arend POM activate by i Output time(Second): hal +0 s9)8 0 DeaaieSaNY we Tet tts range PGM4 Assign PGM to Area’ Tawa! | Aea2 | Areas Arad POM activate by a Output time(Second): [120 "10 -999)Se 0 Deactivated ony when cen status change Save Wii SCS 6. ALARM RECEIVING BY USERS (VOICE PHONE) Click icon 0” enter into alarm receiving setting(Voice Phone). 6.1 Voice Phone: support 1-4 voice phone No. 6.2 Phone Area: Phone 1/2/3/4 can remote control 1-4 areas, when there is a message coming from check mark areas. The host sends message to the voice phone No. that areas belongs to. 6.3 Phone Control Platform Forwarding Server: offered by the operator Server Port: 18034 ( default) Device ID: automatic generation by host Login PWD: 09985678 Voice Phone Phone 1 eS Phone 2: === Phone 3 as Phone 4: ai Dial Ring Times. 5 ca ‘Set Phone Area Phone 1 Fara1 [Atea2 [Areas I Areas Phone 2: Fara1 [Atea2 [Areas I Areas Phone 3 Fara1 [Atea2 [Areas I Areas Phone 4. Farea1 Area2 [Areas I Areas Phone Control Platform Forwarding server: “Percoman Sener Port 10034 Device 1D: Login PWD" APP scan QR code register app scan the QR code and automatic log into the correspond account. Setting saved then making effect 7. WIRELESS DEVICES Android Click up icon % enter into wireless device setting 7.4 Wireless Remote Controller: Input the remote ID , code and check mark the owned areas, press save button. Users can remote control the areas that remote controllers belongs to. 7.2 Wireless Detector: Input the detector ID and code, press saved. 7.3 Wireless Siren: 7.3.1 Enroll wireless siren: Please make sure the siren away from the panel within 3 meters, press the siren code and hold on, and click the Click Coding. When you hear the beep sound of siren, you need to release the siren code button.After coding successfully, pls trigger the alarm panel once firstly to check the siren if it will sound and code successfully. Wireless Remote Controller remote No.(1-8) Remote ID: Remote Involved I Area Area2 Area3 Area 4 Save Wireless Detector Detector No.(01-32): Detector ID: Save Wireless Siren Wireless siren coding: Click Coding Delete dual way siren: - Wii SCS 7.3.2 Delete dual-way siren: Click the dual-way siren column, and choose the siren you want to delete. 8.ZONE ATTRIBUTION Click up icon enter into zone attribution. Delay 1 Zone. 8.1 Zone Attribution: 10 kinds of the zone type, default is |Delav2 Zone disabled zone. Siren type have sustaining tone, impulsive tone |interior Zone and mute for options, default is sustaining tone. a zone permits |Emergency Zone . 24 Hour Zone itself belongs to 4 areas. Setting saved. Sea Linkage switch: Turns the electrical switch on or off within |water leakage Zone the linkage time by triggering the zone. The linkage switch state [Key Zone is the state of the electrical switch associated with the trigger zone, and the switch linkage time is the time when the electrical switch maintains the linkage switch state. Zone Attribution Zone No.(001-128): Zone type Disebied Zone |] en Type sustaring Tors] hime chime Zone Name: wae ates ‘Area Involved: 7 Area 1 T Area 2 T Area 3. T Aread ‘Switch NO.(01-32): och status on Gl Output time: 0-900s Set D, si Stats willbe locked until he next operation Save 8.2 Keypad Area Involved: input the keypad address and check mark the keypad area involved. Setting saved. Keypad Area Involved Keypad Address(1-8) Keypad Area Involved: "Area t Area 2 Area3 Area 4 Wii SCS 8.3 Associated Zones: Set two zones as associated zone groups to trigger an alarm if two zones are triggered within the associated time. 8.4 Wire zone loop: EOL, N.O.,N.C., default is EOL a. Line tail resistance: EOL of the zone is normal at 2.2K, and the zone open circuit or short circuit alarm; b. N.O.: the open circuit of the zone is normal, short circuit alarm; c.N.C.: the short circuit in the zone is normal, open circuit alarm. After setting, click "Save" to take effect. CROSS ZONE cr zone gp : Cross zone first: “one 128 Cross zone second: cael —— “oa WIRE ZONE LOOP Wire zone: El Loop: FOL El Save Bypass Group one ‘Group 2: owe ‘Group 4: qo Sc Sic. manual 9.EVENT LOG Click up the icon (Gj enter into the event log, inquiry the areas/zones Juser system recording, host can cycle storage up to 800 event logs recording. Number 1 eoeronnon " 2 13 14 18 16 7 18 19 20 a 2 23 24 28 Time 2004-01-24 01:26:01 2004-01-24 01:25:59 2004-01-24 01:13:19 2004-01-24 01:12:56 2004-01-24 01:12:33 2004-01-24 01:12:26 2004-01-24 01:04:42 2004-01-24 01:04:37 2004-01-24 00:19:03 2012-01-01 08:00:01 2012-01-01 08:00:00 2004-01-22 19:05:54 2004-01-22 19:00:19 2004-01-22 18:59:33 2004-01-22 18:57:35 2012-01-01 08:00:01 2012-01-01 08:00:00 2017-01-09 15:06:09 2017-01-09 15:05:41 2017-01-09 15:04:44 2017-01-09 15:04:14 2017-01-09 15:00:35 2017-01-09 15:00:32 2017-01-09 15:00:12 2017-01-09 14:50:14 Area 1 Zone/User 141 141 155 155 155 155 141 141 141 ° 0 155 141 141 155 155 10 155 155 155 195) 155 Event System Disarm System Arm System Disarm System Arm System Disarm System Arm system Disarm System Arm System Disarm System Low Battery Siren Faulty System Arm System Disarm System Arm ‘System Programming Changed System Low Battery si 5 Faulty System Disarm Systom Armed Stay Zone Bypass System Disarm System Armed Stay Ssystom Disarm system Arm ‘System Disarm Wii SCS 10.REMOTE UPGRADE Click up icon Ly enter into the remote upgrade setting, to view the system version and hardware version, users need to download the install pack first, click “Browsing” will pop up a page and then select install pack click submit. The bottom of the page there will be a red strip and percentage display during the upgrade process, do not close the page and turn off the host power, once the upgrade is completed then reboot the host device. ‘System version Web version: vo.003 Hardware version: V0.005 Plus Software version: 0.016 MEIAN_TCP Jul 7 2018 11:50:51 Web update Web file: Browsing ‘Submit ‘System update ‘System file: Browsing ‘Submit 11. SYSTEM REBOOT Click up the icon © starting reboot system or restore to factory default setting. Reboot system Reboot system: Reboot system Restore to factory default Restore to factory default: factory default Delete all event logs: Del event log Delete all wireless devices: Del wis device Delete all BUS device Del BUS device Sic. manual 11.1 system reboot, press confirm to reboot system and pop-up message box that reminder users are you sure to reboot the system? If yes, press confirm, otherwise press cancel. Information from web pages ad From the web page information — fr you sure to reboot he A Toe tem reboots neces nce and pontoacess esa mene => za [Bae] 11.2. Set back to factory default, click factory default button and pop-up message box that reminder input the admin password. Please input the correct password and make the host restore to factory default setting. 192.168.7.80 Need some information Script prompt: Determine | tease enter the adninistrator passrord and confirm agein Cancel 11.3 Backup and Recovery a. Export system configuration file: If you want to set multiple host parameters to the same configuration, you can export the set device parameters and import the exported files to the new host to be set. Export the system configuration file, click "Export" to pop up the window to prompt the download task, click "Download" to save the file b. Import configuration file: Click “Browsing” to pop up the loading window, select “Config.bin” file and open it. At this time, the window will be closed automatically and the file address will appear in the import configuration file. Click “Submit” Backup and recovery Export the configuration file: Export Import system configuration file: Browsing Import Wii SCS 12.ALERT SETTING yr Click the icon @ enter into the alert setting 12.1 Alarm Event: 42 alarm events for options, once trigger to alarm or system in fault status, it will notice to users as preset path forwarding ways. Un-checking a checkbox will disable it. As factory default setting is checked. please click save after setting up Alarm Event. Alarm event cms: Path forwarding, Voice Phone SMS Save The panel will select the network to send the message in priority. When the network failed, GPRS will be connected to the CMS.When the Network CMS fails, the panel will send data to the CMS phone through GSM or PSTN ,and the panel will choose PSTN to send the data in priority. Host sends data can choose whether to send to user or platform, and choose what ways to send to the user, when the network fault, it will enable the GPRS and connect to the platform, when Ethernet alarm server fault, it will send data to the mobile receiving server by the GSM or PSTN way, PSTN is priority for the host choosing. As below photo. ‘Alarm iu (Bi OK. rN PANEL 7 - . Alarm « Center 2 <—> By Ethernet, GPRS connections “¢----> By PSTN, GSM sending data ~—® By SMS send data Wii SCS 12.2 ERROR DISPLAY SETTING ( KEYPAD DISPLAY): When the network cable, SIM card are not insert and in not good way, the keypad LCD will show its fault, user can check the cable and SIM card and remove the fault.By default, except for GSM and telephone line faults, all the checkmarks are displayed. After the user is set up, you must click Save Error display setting System AC fault ‘System battery fault Network faut GSM fault Keypad display fault: Telephone line fault Wired siren fauit CMS linkage faut CID communication fault APP communication fault Save 12.3 GSM MODULE AND APN SETTING The setting of the SIM card access to the network, that is Sim card GPRS access point, APN account and password set by the users, If do not know the APN account and password, please consult your SIM operator. GSM Module APN Setting APN Setting APN User: APN PWD Save “if you dont understand the setig, please consult your SIM operator. Wii SCS 13.TIME SETTING Click the icon enter into the time setting. 13.1 SYSTEM TIME: Input the time from the enter time input box, setting saved, the keypad LCD display the time registration. Host have the power off memory functions, the precondition is that GSM already registered to the network, and the host is given a correct time by the users. ‘System time ‘Alarm host time: Enter time: 2018-713 14:33:45 Save SNTP setting ‘Automate Calibration Daylight Saving Time Server Time Time Zone (GMT) ‘enrt-1200 |=] Save Timing armidisarm : © Areat @ Area disarm = nea Area? Timi ea stay arm ng 00:00 a nena ‘Area arm Areas : © Areat @ Area disarm = pense, ‘Area? Timing 2 00:00 yea stay arm ~enn Area arm Area : * Areat © Area disarm - peat, Avea2 Timing 3: 00:00 y aes ‘Area arm Areas * Areat @ Area disarm pare ‘Area? Timing 4: rea stay arm ing 4: 90:00) ¥ Area Area arm - Areas Save “2000's an inva, wich can be used delete certain timing, Sic. manual 13.2 SNTP SETTING: Check the automatic timekeeping and save it after the access network cable or GSMis in normal use.; Daylight Saving Time is set aside by an hour at 2Am on the first Sunday of middle April. Change 2Am to 3 Am. At 2 o'clock in the morning on the first Sunday in mid-September, The hour will be set aside for one hour, that is, changed from 2Am to 1Am, and the Daylight Saving Time ends. 13.3 TIMING ARM/DISARM: user ticks the areas that support disarm/stay arm/arm under the setting time, please click save and setting up. The system reminds you operation successful 14.SMART HOME Click the icon © enter into the Smart home. Serial switch name _ | Status|| ON/OFF Control Timing ON Timing OFF Submit H x = 00.00 00:00 Save b x = 00-00 00:00 Save b x = 0:00 00:00 Save I: x El 00:00 00:00 Save [: x El 00.00 00.00 Save ip x i 00:00 00.00 Save I x i] 00:00 00:00 Save [ x Gy 00°00 00°00 Save b. x i 0-00 0-00 Save Ho. x = 0:00 00:00 Save Ht x I 0:00 00:00 Save 2 x a 00-00 00:00 Save 1. Please enroll the smart light switch from the panel configuration 2. Users can name the smart light switch and set the timing on/off periods Max support 32 CH light switch wq Wii SCS TECHNICAL SPECIFICATION GENERAL INFORMATION 1.External AC Power supply: input 110-240V AC, output 15V DC/3A 2.Built in rechargeable battery:12V/7AH 3.Battery stand by time:16H 4.Frequency:433MHz/868MHz 5.Signal transmit distance: 100 to 120 meters (open area) 6.The method of alarming dial: DTIMF GSM or GPRS 7.Communication protocol with CMS: Ademco Contact ID 8.DTMF dial frequency variation:<1.5% Physical performance Operation temperature range: 0°C-45°C (32°F-120'F) Storage temperature range: -20°C-60°C(-4'F-140°F) Relative humidity: 85% at 30°C (86'F ) REGULAR TEST PERIODIC TESTING Design of components of the system is to reduce maintenance cost, but still it is suggested that periodical check may be carried out. THE CLEANLINESS OF CONTROL MAIN MACHINE Main control panel may be stained by fingers or covered by dust after using for a while. Use soft cotton cloth or sponge to clean it, don't use any lubricant, liquid such as kerosene, acetone and strong gel which will damage appearance and the transparency of top window. Attention: don't use any lubricant, liquid such as kerosene, acetone and strong gel which will damage appearance and the top transparency of window. Wii SCS LIMITATION OF THE PRODUCTS. Although the products is a high standard products, there is also some limitation of them such as false alarm or no alarm. The reasons may be below: Lack of maintenance, the system needs maintenance and test regularly test the sensitive of the detector may decrease and the siren may not whistle. Lack of power supply if no power input and the back up power is not enough, the panel can not work normally. Telephone line false, if the telephone line is cut, the panel could not send alarm signals. Limitation of smoke detectors, if the smoke is far from the smoke detector, the detector could not alarm. If the intrude break in through some door or window not monitored. Or someone know how to make the system not work.

You might also like