0% found this document useful (0 votes)
99 views1 page

Beijing Choice MD300C1 Specification VER - 1.0

The document describes an MD300C1 fingertip pulse oximeter. It is a small, lightweight device that measures blood oxygen saturation (SpO2) levels and pulse rate. Key features include a digital LED display of SpO2 and pulse rate readings, low power consumption, and automatic power-off. It is suitable for adult and pediatric patients, operates on 2 AAA batteries, and is widely used in medical settings to monitor patient vital signs.

Uploaded by

Rudie de Jongh
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
99 views1 page

Beijing Choice MD300C1 Specification VER - 1.0

The document describes an MD300C1 fingertip pulse oximeter. It is a small, lightweight device that measures blood oxygen saturation (SpO2) levels and pulse rate. Key features include a digital LED display of SpO2 and pulse rate readings, low power consumption, and automatic power-off. It is suitable for adult and pediatric patients, operates on 2 AAA batteries, and is widely used in medical settings to monitor patient vital signs.

Uploaded by

Rudie de Jongh
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

MD300C1

Fingertip pulse oximeter

The Scope of Application Features


Pulse oximeter is a very important and common device to check  Small & lightweight design ( total 28g without batteries )
patient blood-oxygen saturation (SpO2) level and pulse rate. As a
 Digital LEDs display
small, compact, simple, reliable and durable physiological monitoring
 Display SpO2,PR,Pulse bar
device, Fingertip pulse oximeter greatly enhances patient care. It is
 Low power consumption
widely applied in clinic, hospital, social medical organizations, first aid
 automatically power off
and so on.
 Battery-low indicator

 2 AAA alkaline or rechargeable batteries


 Accommodates widest range of finger sizes from pediatric to adult
Technical Specifications
Patient Range Battery
Adult and Pediatrics patients Type 2 AAA alkaline or rechargeable batteries
Operation time about 40 hours for normal operation
SpO2
Measurement range 70-100% Environmental
Resolution 1% Operation Temperature 5℃-40℃
Measurement accuracy 80%-100%: ±2% Storage Temperature -20℃-55℃
70%-79 %: ±3% Operation Humidity RH≤85%
0%-69%: unspecified Storage Humidity RH≤85%
Pulse Rate
Measurement range 30-235 bpm Electromagnetic Compatibility
Resolution 1bpm This product complies with IEC60601-1-2 for electromagnetic
Measurement accuracy 30- 100: ±2 bpm compatibility Class B
101- 235: ±2%
Interference Resistance Capacity against Ambient Light
Display Deviation is smaller than ±1% between values of Oxyhemoglobin
Type Digital LEDs display measured in natural lighting indoor condition and present lighting sources
Parameters SpO2, PR, Pulse bar and that measured in dark room.
Mode 1 display mode

Alarm
Alarm Battery-low indicator

Mechanical
Dimension 58mm(W)×32mm(H)×34mm(D)
Weight 28g (without batteries)

AUTHORIZED AGENT

Beijing Choice Electronic Technology Co., Ltd


Address: Rm 1127-1128,Bailangyuan Building B, Fuxing Road A36, Beijing, P. R. China Zip: 100039
Tel: +86 10 88204188,68221006,88203520 FAX:+86 10 88204632
Email: [email protected] Website: www.choicemmed.com