1E ME0084RevD
1E ME0084RevD
1E-ME0084
Document Classification
Project: OFGI - OFFSHORE GAS INCREMENT Index: G - LIQUID HANDLING EQUIPMENT
DATE
DATE
DATE
DATE
DATE
THIS INDICATES THAT REV NO NO.
D OF THIS DRAWING IS CONTROL NUMBER A 11/10/2022 BI-10-20857 ISSUED FOR INTER DISCIPLINE CHECK MBT SV/DE/RP RP
COVERED, FOR ALL
TY
B 25/11/2022 BI-10-20857 ISSUED FOR CLIENT REVIEW MBT SSSB/SV/ SD
APPROVAL/CERTIFICATION BY:
DE/RP
REQUIREMENT, BY DRAWING
CERTIFIED
SSSSB/SV
24/04/2023
C 17/01/2023 BI-10-20857 ISSUED FOR DESIGN MBT SD
OPERATIONS
COMPLETION CERTIFICATE /DE/RP
CONSTRUCTION
PROJECT ENGINEER
(DCC) NO. SSSSB/DE
DISCIPLINE ENGINEER
DATE: D 24/04/2023 BI-10-20857 ISSUED FOR DESIGN TY SD
/RP
Saudi Aramco 2616-ENG(10/2002)
DWG.TYPE
BI-10-20857
DATASHEET
D42
D42-G-3504A/B
G
INDEX
DOCUMENT CLASS 1
BI-10-20857
SW DRAINS DRUM SLOP OIL PUMPS
DRAWING NO.
1E-ME0084
NOTE : THIS DOCUMENT IS BASED UPON EXISTING FADHILI EQUIPMENT DATA SHEET: D42-G-RE-459704 REV 003
DSN:
11
OF
SHT.NO.
4774
D
REV.NO.
THIS DRAWING AND THE INFORMATION CONTAINED WITHIN HEREIN ARE THE SOLE PROPERTY OF SAUDI ARAMCO. NO REPRODUCTION IN FULL OR PART SHALL BE OBTAINED FROM THE DOCUMENT WITHOUT THE WRITTEN CONSENT OF ITS OWNER.
Saudi Aramco 2741-ENG (07/2013)
SD
SD
SD
RP
SSSSB/SV/
SSSSB/SV/
SSSSB/DE
SSSSB/DE
TABULATION OF REVISED SECTIONS / PAGES
DE/RP
DE/RP
CERT.
/RP
REVISION PAGE / SECTION DESCRIPTION
ENG'G
MBT
MBT
TY
THIS DRAWING AND THE INFORMATION CONTAINED HEREIN ARE THE SOLE PROPERTY OF SAUDI ARAMCO. NO REPRODUCTION IN FULL OR IN PART SHALL BE OBTAINED FROM THIS DOCUMENT WITHOUT THE WRITTEN CONSENT OF ITS OWNER.
D Page 7 of 11 Note 49 added
BI-10-20857
BI-10-20857
BI-10-20857
JO/EWO
17/11/2022
02/12/2022
17/01/2023
24/04/2023
DATE
REV NO.
D
A
DISCIPLINE ENGINEER
TY
DATE 24/04/2023
PROJECT ENGINEER
TABULATION OF HOLDS
DATE
DATE
CONSTRUCTION AGENCY
DATE
OPERATIONS
DATE
EDSD VERIFICATION
CONTROL NUMBER
DATE:
BY:
DATA SHEET FOR SW DRAINS DRUM SLOP OIL PUMPS DWG.TYPE PLANT NO. INDEX DOC NO. SHT. REV.NO
ITEM NO. D42-G-3504A/B DAT 2
D42 G 1E-ME0084
SERVICE : SW DRAINS DRUM SLOP OIL PUMPS OF D
OFFSHORE GAS INCREMENT PROGRAM SAUDI ARABIA JO/EWO- BI-10-20857 11
SAUDI ARABIA
Saudi Aramco 2748-ENG (11/2010)
THIS DRAWING AND THE INFORMATION CONTAINED HEREIN ARE THE SOLE PROPERTY OF SAUDI ARAMCO. NO REPRODUCTION IN FULL OR IN PART SHALL BE OBTAINED FROM THIS DOCUMENT WITHOUT THE WRITTEN CONSENT OF ITS OWNER.
TOTAL SUCTION HEAD FT
/ PUMP Mfr. TOTAL DIFF. HEAD FT
/ SIZE & TYPE TOTAL DISCH. HEAD FT
/ SERIAL NO.
BI-10-20857
DATE
G , G
D
LCC EF $ / kW
BARREL WALL THICKN. IN
DESIGN OPERATING DATA BARREL OD IN asd
BARREL LENGTH FT
SERVICE CL 1st STAGE IMPELLER
OPERATIONS/DATE
TO CL SUCTION NOZZLE FT
CONTINUOUS INTERMITTENT STANDBY
REVIEW FOR KEY DRAWINGS
REQUIRED (SAUDI ARAMCO)
ATTENDED UNATTENDED
PUMP FUNCTION SW DRAINS DRUM SLOP OIL PUMPS MOUNTED ON CONCRETE
INDIVIDUALLY IN SERIES IN PARALLEL MOUNTED ON STRUCTURAL STEEL
UPSTREAM OF PUMP NO(S). G
G
CONST. AGENCY/DATE
FOR CLOSED SUCTION SYSTEMS: ENTER DATA ON FIG. 1 MOUNTED ON VESSEL NOZZLE (NOTE 45)
NPSH AVAILABLE AT SUCTION FLG. (NOTE 25)
AT RATED CAPACITY FT 7.21
AT 120% OF RATED CAPACITY FT 7.21
REVISION VALIDATION
DATA SHEET FOR SW DRAINS DRUM SLOP OIL PUMPS DWG. TYPE PLANT NO. INDEX DRAWING NO. SHT.NO. REV.NO.
REV
CENTRIFUGAL PUMP DATA SHEET FOR VERTICAL LINE SHAFT PUMPS
PERFORMANCE DATA PUMP CONSTRUCTION DATA (CONT'D)
DATED
REVISION DESCRIPTION
THIS DRAWING AND THE INFORMATION CONTAINED HEREIN ARE THE SOLE PROPERTY OF SAUDI ARAMCO. NO REPRODUCTION IN FULL OR IN PART SHALL BE OBTAINED FROM THIS DOCUMENT WITHOUT THE WRITTEN CONSENT OF ITS OWNER.
24/04/2023
EFFICIENCY % Fy lb Fy lb My ft-lb
JOB ORDER/EWO NO.
NPSHR FOR CLOSED SUCT. SYST. AT CL 1st ST. IMPELLER QTY. SIZE TYPE
D
NPSHR FOR OPEN SUCT. SYST. AT CL 1st ST. IMPELLER BARREL DRAIN D
3% DH ON WATER FT SEAL LIQUID INLET
BY/DATE
OTHER
MAX. POWER FULL CURVE ACTUAL IMP. DIAM. HP SHAFT DIAMETER AT BEARINGS IN
BARREL INSULATION PIPING FOR PRIMARY SEAL API FIG. D-2 PLAN 13 / 53B
AND CERTIFICATION REQUIREMENTS, PER SAEP-334, UNDER
DIRECTION OF ROTATION: VIEWED FROM ABOVE FLOW ORIFICE IN SEAL FLUSH SUPPLY LINE YES NO
DATA SHEET FOR SW DRAINS DRUM SLOP OIL PUMPS DWG. TYPE PLANT NO. INDEX DRAWING NO. SHT.NO. REV.NO.
REV
CERTIFIED AND DATED
CENTRIFUGAL PUMP DATA SHEET FOR VERTICAL LINE SHAFT PUMPS
PUMP CONSTRUCTION DATA (CONT'D) PUMP CONSTRUCTION DATA (CONT'D)
THIS DRAWING AND THE INFORMATION CONTAINED HEREIN ARE THE SOLE PROPERTY OF SAUDI ARAMCO. NO REPRODUCTION IN FULL OR IN PART SHALL BE OBTAINED FROM THIS DOCUMENT WITHOUT THE WRITTEN CONSENT OF ITS OWNER.
INSIDE DIAMETER IN OF STD. DRAWING AC-036821
2 IMPELLER(S) ASTM
BI-10-20857
24/04/2023
DATE
FIRST FOLLOW
/ STAGE STAGES LINE SHAFT (SELF LUBRICATED) ASTM
NUMBER OF STAGES
/ ACTUAL DIAMETER IN 8 BEARINGS, LINE SHAFT ASTM
TOTAL EYE AREA IMPELLER IN2 MOTOR SUPPORT & MOUNTING FLANGE ASTM
WEAR RINGS:
CLEARANCES OUTBOARD IN
MAXIMUM ALLOWABLE SOUND LEVEL
PUMP dBA
(DESIGN AGENCY)
OPEN LINE SHAFT BEARINGS, LUBR'D BY MED. PUMPED COMPLETE TRAIN dBA
LUBRICANTS
LINE SHAFT BEARINGS
LIQUID PUMPED WATER
IS COVERED, FOR ALL APPROVAL
COUPLING
DRAWING COMPLETION CERTIFICATE NO.
DATA SHEET FOR SW DRAINS DRUM SLOP OIL PUMPS DWG. TYPE PLANT NO. INDEX DRAWING NO. SHT.NO. REV.NO.
REV
CONSTRUCTION UNTIL CERTIFIED AND
CENTRIFUGAL PUMP DATA SHEET FOR VERTICAL LINE SHAFT PUMPS
UTILITIES (Note 34) DRAWINGS
DATED
AC VOLTS PHASE DRAWING REQUIRED
REVISION DESCRIPTION
DC Hz NUMBER YES NO
ISSUED FOR DESIGN
THIS DRAWING AND THE INFORMATION CONTAINED HEREIN ARE THE SOLE PROPERTY OF SAUDI ARAMCO. NO REPRODUCTION IN FULL OR IN PART SHALL BE OBTAINED FROM THIS DOCUMENT WITHOUT THE WRITTEN CONSENT OF ITS OWNER.
CROSS SECT. DRAWING WITH PART NO'S.
O O
WATER AVAIL. PSIG F F INSTR. WIRING DIAGRAM
D
WELL WATER TREATED WATER SEA WATER COLD ALIGNMENT CURVE IF REQ
ONCE THROUGH SYSTEM CLOSED LOOP SYSTEM DATA L. & T. VIBR. ANALYSIS IF REQ
BY/DATE
OTHER
MANUFACTURER'S STANDARD
CONST. AGENCY/DATE
AS FOLLOWS
OBSER'D
CERT'D
WITN'D
NONE
HYDROSTATIC TEST
WATER KEROSENE
RUNNING TEST
PERFORMANCE TEST
NPSH TEST
DISMANTLING
DESIGN CERTIFICATION
VIBRATION MEASUREMENTS
MASSES
IS COVERED, FOR ALL APPROVAL
DATA SHEET FOR SW DRAINS DRUM SLOP OIL PUMPS DWG. TYPE PLANT NO. INDEX DRAWING NO. SHT.NO. REV.NO.
REV
UNTIL CERTIFIED AND DATED
THIS REVISION IS NOT TO BE
USED FOR CONSTRUCTION
NOTES
THIS DRAWING AND THE INFORMATION CONTAINED HEREIN ARE THE SOLE PROPERTY OF SAUDI ARAMCO. NO REPRODUCTION IN FULL OR IN PART SHALL BE OBTAINED FROM THIS DOCUMENT WITHOUT THE WRITTEN CONSENT OF ITS OWNER.
4. DELETED D
5. DELETED D
24/04/2023
6. NOT USED
DATE
7. PUMP / MOTOR SET SHALL NOT EXCEED 85 dB(A) AT A DISTANCE OF 3.28 Ft. D
BI-10-20857
JOB ORDER/EWO NO.
8. MOTOR SHALL BE SIZED FOR END OF CURVE (AT FLOW EQUAL TO OR GREATER THAN 120% OF RATED FLOW) WITH S.G. = 1
AND SELECTED RATING SHALL NOT LESS THAN 125% OF RATED POWER
9. MECHANICAL SEAL SHALL COMPLY WITH 31-SAMSS-012 AND API 682 3RD EDITION
REV. NO.
21. DELETED
REQUIRED (SAUDI ARAMCO)
22.DELETED
CONST. AGENCY/DATE
23. DELETED
24. DELETED
25. NPSHA VALUE IS CORRECTED AT PUMP CL EQUAL TO 7.21 FT (CONSIDERING PUMP CENTRELINE AT 1.65 FT (BY SUPPLIER)
BELOW VESSEL BOTTOM TANGENT LINE).
26 . NOT USED
27. DELETED
28. SUPPLIER TO PROVIDE A START-UP SPARE CARTRIDGE SEAL UNIT COMMON TO THE SET OF PUMP
CERTIFIED/DATE
29. SUPPLIER SHALL APPLY VISCOSITY CORRECTION FACTOR ON THE PUMP HEAD, CAPACITY AND EFFICIENCY AS PER HYDRAULIC
INSTITUTE STANDARD HI 9.6.7 WHILE DESIGNING THE PUMP. VISCOSITY @ 46 °F IS 27.31 cP
DESIGN CERTIFICATION
31. FOR ANY INSTRUMENTS / PROBES ON SEAL SYSTEM AND AUXILIARIES, SUPPLIER SHALL SUPPLY AND INSTALL INSTRUMENTS WITH
REQUIRED INSTALLATION HARDWARE, IMPULSE TUBES AND FITTINGS, CABLING, JUNCTION BOX, ETC.
32. CENTRIFUGAL PUMP SHUT OFF HEAD SHALL NOT EXCEED 125% OF SPECIFIED DIFFERENTIAL HEAD INCLUSIVE OF 0%
SHUT OFF HEAD TOLERANCE AND ESTIMATED PUMP SHUTOFF PRESSURE SHALL BE LIMITED TO 101.6 PSIA
33.DELETED
ENGG./DATE
34. FOR SITE DATA & UTILITIES REFER TO BEDD 1E-EM0001-001 Rev A
35. DELETED
36. EACH PUMP AND MOTOR SHALL BE PROVIDED WITH A SEISMIC TRANSDUCER CONNECTION (DRILLED AND TAPPED
3/8"-24 TPI X3/8" DEEP) ONLY IN X,Y DIRECTION ON EACH BEARING HOUSING AS PER 31-SAMSS-004 SEC 7.4.2
37. THE PUMP SHALL BE TESTED IN ACCORDANCE WITH 175-310600 AND MOTOR IN ACCORDANCE WITH 175-170200.
38. NOT USED
39. DELETED
IS COVERED, FOR ALL APPROVAL
40. SOUR WATER DRAIN DRUM (D42-G-1503) DIAMETER IS 8.5 FT (2591 MM) WITH A 1.51 FT (700 MM) DEEP BOOT
FOR THE PUMP (PRELIMINARY DATA).
AND CERTIFICATION REQUIREMENTS, PER SAEP-334, UNDER
41. DELETED
REVISION VALIDATION
46. MOUNTING PLATE SHALL BE PARALLEL TO TRUE HORIZONTAL CENTRLINE OF VESSEL WITH 0 mm TOLERANCE OR SHALL SPECIFY
ACCEPTABLE LEVEL OF TOLERANCE AT MOUNTING PLATE.
47. VENDOR SHALL RETURN THE EQUIPMENT NOISE DATA SHEETS ADEQUATELY FILLED IN
48. PUMP SHALL ALSO COMPLY TO THE REQUIREMENTS SPECIFIED IN SAES-G-005.
D
DATA SHEET FOR SW DRAINS DRUM SLOP OIL PUMPS DWG. TYPE PLANT NO. INDEX DRAWING NO. SHT.NO REV.NO.
DRAWING COMPLETION CERTIFICATE NO. JOB ORDER/EWO NO. THIS REVISION IS NOT TO BE
USED FOR CONSTRUCTION
BI-10-20857 UNTIL CERTIFIED AND DATED
Saudi Aramco 2616-ENG (11/2010)
OIL PUMPS
ITEMS NO. D42-G-3504A/B
DAT
SAUDI ARABIA
DWG. TYPE
D42
2010 mm
PLANT NO.
G
INDEX
SAUDI ARABIAN OIL COMPANY
DRAWING NO.
1E-ME0084
8
11
OF
SHT.NO
24", 150# RF
PUMP NOZZLES
D
REV.NO.
EKRD/2616-1110.XLS
REV
THIS DRAWING AND THE INFORMATION CONTAINED HEREIN ARE THE SOLE PROPERTY OF SAUDI ARAMCO. NO REPRODUCTION IN FULL OR IN PART SHALL BE OBTAINED FROM THIS DOCUMENT WITHOUT THE WRITTEN CONSENT OF ITS OWNER.
JOB NO. BI-10-20857 ITEM NO. D42-GM-3504 A/B
APPD.
RP
SD
SD
SD
SAUDI ARAMCO PURCHASE ORDER NO.
SPECIFICATION NO.
Severe Duty Totally Enclosed Squirrel Cage Induction REVISION NO. D DATE 24/04/2023
CERT.
SSSSB/SV/
SSSSB/DE
DE/RP
CHKD.
RP
2 FOR OFFSHORE GAS INCREMENT PROGRAM UNIT D42
3 SITE Fadhili Saudi Arabia SERIAL NO.
4 SERVICE SW DRAINS DRUM SLOP OIL PUMPS NO. REQUIRED 2
5 DRIVEN EQUIPMENT TYPE: COMPRESSOR GENERATOR OTHER PUMP
6 NOTE: INFORMATION TO BE COMPLETED BY: PURCHASER MANUFACTURER
7
8 Purchaser's Data to Be Supplied With Inquiry:
ISSUED FOR INTER DISCIPLINE CHECK
9 BASIC DATA:
ISSUED FOR CLIENT REVIEW
12 Rotation When Facing Motor Opposite Drive End: Clockwise Counter-Clockwise Bi-Directional
13 Motor Thrust Loads: None Other (specify) Type Load: Direct Coupled Belt Driven Other
14 NEMA Torque Design "B" (normal) Other (specify)
15 SITE DATA:
16 Site average temperature: (NOTE 34) °C
21 Full Voltage Reduced Voltage % Type Adjustable Frequency Drive Unit Type
22 AFD Details Attached (If motor purchased separately from drive unit.)
BI-10-20857
BI-10-20857
BI-10-20857
BI-10-20857
JO/EWO
23 MOUNTING:
24 Horizontal Vertical Shaft Up Vertical Shaft Down Foot Mounted Flange Mounted, NEMA Type
25 ENCLOSURE:
MBT
MBT
MBT
BY
TY
25/11/2022
17/01/2023
24/04/2023
DATE
28 Space Heaters:
29 Space Heater Required for motors rated less than 75kW (100HP)
30 Heater Leads: Main Terminal Box Separate Heater Terminal Box
REV NO.
D
A
31
32 Note :
#SPILL! 33 (1) NOT USED
34 (2) Unless and otherwise specified Motor shall be suitable for S1 duty.
DRAWN 35 (3) Coating and painting shall be suitable for severely corrosive environment.
BY 36 (4) Motor colour shade shall be Green colour (RAL 6021)
DATE 37 (5) The maximum relative humidity to be considered for design shall be 100%
CHKD BY 38 (6) Seismic conditions (site class shall be "C" as per ASCE 7-2005)
OPRG. DEPT. 39 (7) The starting time curve to be proivded for 100% and 80% voltage alongwith Torque speed curve
BY 40 (8) Motors shall be suitable to start with 80% of rated voltage at the motor terminals
DATE 41 (9) The ingress protection for Motor and Terminal box shall be IP55
42 (10) Motors for use in Zone 2 hazardous (classified) locations shall be of the Totally Enclosed type, per NEMA, or Ex-n, per IEC,
ENG. DEPT. 43 as a minimum
BY 44 (11) Motors for use in Zone 1 hazardous locations shall be flameproof motors EEx d.
DATE 45
APPD. FOR 46
CONSTR. 47
BY 48
DATE 49
50
CERTIFIED 51
BY 52
DATE 53
APPD.
JOB NO. BI-10-20857 ITEM NO. D42-GM-3504 A/B
RP
SD
SD
SD
SAUDI ARAMCO
PAGE 10 OF 11 BY TY
Severe Duty Totally Enclosed Squirrel Cage Induction PLANT NO D42 INDEX G DRAWING NO 1E-ME0084
CERT.
SSSSB/SV/
SSSSB/DE
1
CHKD.
DE/RP
DE/RP
RP
2 MANUFACTURER MODEL DRIVEN EQ. ITEM NO. D42-G-4207 A/B
3 MOTOR DATA
7 Rotation When Facing Motor Opposite Drive End: Clockwise Counter-Clockwise Bi-Directional
8 Torque:
ISSUED FOR INTER DISCIPLINE CHECK
9
ISSUED FOR DESIGN
13 Amperes
14 Power Factor
15 Nominal Efficiency
16 Guaranteed Efficiency
17
19 Insulation System:
21 Bearing Information:
BI-10-20857
BI-10-20857
BI-10-20857
25 Weights/Dimensions:
MBT
MBT
MBT
BY
TY
24/04/2023
27 Shaft Data
10/11/2022
25/11/2022
DATE
D
A
31
32
REVISIONS 33
DRAWN 34
BY 35
DATE 36
CHKD BY 37
OPRG. DEPT. 38
BY 39
DATE 40
ENG. DEPT. 41
BY 42
DATE 43
44
APPD. FOR 45
CONSTR. 46
BY 47
DATE 48
CERTIFIED 49
BY 50
DATE 51
Saudi Aramco 7305-ENG (11/2010)
REV
ISSUED FOR DESIGN EQUIPMENT NOISE DATA SHEET
REVISION DESCRIPTION
THIS DRAWING AND THE INFORMATION CONTAINED HEREIN ARE THE SOLE PROPERTY OF SAUDI ARAMCO. NO REPRODUCTION IN FULL OR IN PART SHALL BE OBTAINED FROM THIS DOCUMENT WITHOUT THE WRITTEN CONSENT OF ITS OWNER.
GENERAL INFORMATION
BI-10-20857
JOB ORDER/EWO NO.
PURCHASER'S REQUIREMENTS
REV. NO.
This form shall be completed for each piece of equipment (or integrated unit) that is likely to generate noise in excess of 85 dBA at a
D
distance of one meter. If the noise level is greater than 90 dBA, the cost of special design and/or acoustic treatment should be
supplied. Measurements are to be made in accordance with ANSI S1.13 and at full design load, unless otherwise indicated. For
rotating electric machinery, use points defined in IEEE Standard 85.
BY/DATE
OTHER
OPERATIONS/DATE
20 - 75 63
(DESIGN AGENCY)
75 - 150 125
150 - 300 250
300 - 600 500
ENGG./DATE