Technical Guide Stellar Plus TM Models - E - fh018 Thru E - fh060 Split-System Heat Pumps Rev C (07 - 00)
Technical Guide Stellar Plus TM Models - E - fh018 Thru E - fh060 Split-System Heat Pumps Rev C (07 - 00)
DESCRIPTION
TECHNICAL These high efficiency EFH Series heat pump units are the outdoor part of
a versatile system designed to economically heat and cool a home or
small business. The compact design of these outdoor units make them
GUIDE ideal for ground or roof installation. The units contain enough refrigerant
charge for the outdoor unit, a matched indoor coil and 15 feet of intercon-
necting piping.
EFH heat pumps can be custom-matched with one of YORK's two lines of
evaporator blower sections, each designed to serve a specific function.
® Electric heaters are available for both, in a variety of sizes.
For Add-On applications, the indoor coil may be applied in the supply duct
of a conventional gas, oil or electric furnace. The heat pump will be the pri-
mary source of heat for the building with the furnace operating only when
the heating requirement exceeds the capacity of the heat pump.
FEATURES
QUALITY CONDENSER COILS - The coil is constructed of copper tube
STELLAR PLUSTM and hardened black coated aluminum fins for durability and long lasting
efficient operation. The fins on the unit are protected with a decorative
MODELS: E*FH018 THRU E*FH060 grille.
DURABLE FINISH - Cabinet is made of pre-painted steel. The pre-treated
flat galvanized steel provides a better paint to steel bond, which resists
SPLIT-SYSTEM HEAT PUMPS corrosion and rust creep. Special primer formulas and glossy earth tone
finish insure less fading when exposed to sunlight.
Nominal Capacity: 18 thru 60 MBH
LOWER INSTALLED COST - Installation time and costs are reduced by
Nominal Efficiency: 12.00 SEER the fully exposed refrigerant connections and the single panel covering of
the electrical controls. The small base dimension means smaller mounting
pads or less materials required for mounting, lowering installation costs.
COMPRESSOR - 2 - 5 ton models are equipped with scroll compressors
which are internally protected against high pressure and temperature.
This is accomplished by the simultaneous operation of high pressure relief
valve and a temperature sensor which protect the compressor if undesir-
able operating conditions occur. The compressor is protected by a 10 year
limited warranty.
COMPLETE SYSTEM CONTROL - These heat pump units utilize the
unique YorkGuard V microprocessor control system to provide optimal
comfort control and assure reliable operation. The YorkGuard V control
system continuously monitors the space environment to maintain optimum
efficiency. It initiates defrost only when necessary to further reduce heat-
ing costs and improve reliability. Supplemental heat can only operate
below the balance point and then only upon need. In the event of improper
operating conditions (high temperature and high pressure), the YorkGuard
V will shut the system down to extend the life of the heat pump. Rapid
cycling is prevented by use of an integral anti-recycle timer. Loss of
charge protection is provided by a discharge temperature sensor and
internal compressor overloads.
Finally the YorkGuard V control provides system diagnostics to aid the
service technician, minimizing repair time and cost. The YorkGuard V con-
trol even stores important information for use during servicing and has a 5
year warranty.
LOW OPERATING SOUND LEVEL - The discharge air from the top
mounted fan is blown up away from the structure and any landscaping
carrying the normal operating noise up away from the living area. The rigid
top panel effectively isolates any motor sound. Isolator mounted compres-
sor and the rippled fins of the condenser coil muffle the normal fan motor
and compressor operating sounds.
KW includes compressor, outdoor fan and indoor blower motor watts. Add-on coils include 365 watts/1000 CFM for blower motor.
Integrated heating capacities include the effect of defrost cycles in the temperature range where they occur.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTUs during a normal annual usage period for cooling divided
by the total electric power input in watt-hours during the same period.
EER (Energy Efficiency Ratio) is the total cooling output in BTUs at a 95 ° F outdoor ambient divided by the total electric power in
watt-hours at those conditions.
COOLING CAPACITY - With Upflow, Downflow and Horizontal Furnace and Coils
FURNACE* COOLING
UNIT COIL†
NOMINAL RATED NET MBH SEER/
MODEL W MODEL KW SEER EER
AIRFLOW CFM TOTAL SENS. TXV‡
E*FH WITH HORIZONTAL FURNACE AND COILS
14,17 G1UA024S14,17 650 18.8 14.1 1.8 12.00 --- 10.55
800 14,17 G2FD024S14, 17 650 19.0 14.3 1.8 12.50 --- 10.65
E4FH018
1000 14 G1UA030S14 650 19.0 14.3 1.8 12.05 --- 10.65
14,17 G2FD030S14, 17 650 19.4 14.6 1.8 12.15 --- 10.85
14,17 G2FD024S14,17 800 23.4 17.6 2.2 12.10 --- 10.85
** G1HD024 800 23.4 17.6 2.2 12.10 --- 10.75
800
14 G1UA030S14 850 23.0 17.3 2.2 12.00 --- 10.85
E4FH024 1000
17,21 G1UA036S17,21 850 23.8 17.9 2.2 12.20 --- 10.85
1200
17 G2FD030S17 850 23.4 17.6 2.2 12.10 --- 10.80
14 G2FD035S14 850 23.4 17.6 2.2 12.10 --- 10.80
17 G1FD030S17 1000 28.2 21.2 2.9 --- 12.00 10.35
14 G2FD035S14 1000 29.0 21.8 2.9 --- 12.00 10.35
1000
17,21 G1UA036S17,21 1025 28.2 21.2 2.9 --- 12.00 10.35
E4FH030 1200
** G1HD036 1025 29.0 21.8 2.9 --- 12.00 10.45
1400
17 G2FD036S17 1025 29.0 21.8 2.9 --- 12.40 10.65
21 G2FD036S21 1025 29.0 21.8 2.9 --- 12.40 10.65
21,24 G1UA048S21,24 1225 35.4 26.2 3.31 -- 12.50 10.70
17 G1UA048S17 1225 35.0 25.9 3.30 -- 12.10 10.60
1200
21 G2FD42S21 1225 34.8 25.8 3.30 -- 12.20 10.55
E4FH036 1400
17 G2FD046S17 1225 35.0 25.9 3.30 -- 12.10 10.60
1600
21 G2FD036S21 1225 34.6 25.6 3.30 -- 12.00 10.50
17 G2FD036S17 1225 34.6 25.6 3.30 -- 12.00 10.50
21 G2FD042S21 1400 40.0 29.6 3.81 -- 12.00 10.50
1400 21,24 G1UA048S21,24 1425 40.5 30.0 3.79 -- 12.40 10.70
E4FH042 1600 17 G1UA048S17 1400 40.5 30.0 3.80 -- 12.25 10.65
2000 17 G1UA046S17 1400 40.5 30.0 3.80 -- 12.25 10.65
21,24 G2FD048S21,24 1425 41.0 30.3 3.80 -- 12.40 10.80
21,24 G2FD048S21, 24 1600 47.5 35.6 4.6 --- 12.00 10.50
17 G1UA048S17 1600 47.0 35.3 4.6 --- 12.00 10.40
1600
E4FH048 21 G1UA048S21 1620 47.0 35.3 4.6 --- 12.00 10.50
2000
21,24 G1UA060S21, 24 1620 47.5 35.6 4.6 --- 12.20 10.75
24 G2FD060S24 1620 48.0 36.0 4.6 --- 12.40 10.75
21,24 G1UA060S21,24 1850 57.0 41.0 5.48 -- 11.70 10.40
E4FH060 2000 24 G2FD060S24 1850 58.0 42.0 5.42 -- 12.00 10.70
24 G2FD061H24 1850 58.5 41.5 5.46 -- 12.20 10.70
*. Heating MBH based on 70 ° DB entering indoor air, 72% RH outdoor air with 25 ft. of interconnecting piping and no electric heat
operation.
HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by
the total electric power input during the same period.
*. Heating MBH based on 70 ° DB entering indoor air, 72% RH outdoor air with 25 ft. of interconnecting piping and no electric heat
operation.
HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by
the total electric power input during the same period.
ACCESSORIES
Refer to Price Manual for specific model numbers. Blower -Off Delay - (2FD06700224) - Available to increase effi-
ciency. Installs on indoor section to maintain blower operation for
Service Analyzer - Provides on-the-spot system analysis and/or
approximately 1 minute on shutdown. Standard on most models.
trouble shooting capacity. Order 025-25980-000 from Source 1 Parts
Department. Room Thermostats - A wide selection of matching thermostats is
available to provide features required for any installation.
Outdoor Thermostats (2TD06700124) - Consists of an adjustable
outdoor thermostat and a relay in a vented enclosure. It provides 2TH11702224 – 2H/1C with subbase, manual change over non-elec-
additional second stage control of the supplemental resistance heat. tronic thermostat.
TXV Kit - 1TV0700 Series TXV must be used to obtain system per- 2TH11702424 – 2H/1C with subbase, automatic change over non-
formance. See Tabular Data Instructions for details. electronic thermostat.
Add-On Control (2AC02700801) - Provides interface between gas, 2ET11704324 – 2H/1C non-programmable electronic thermostat,
oil or electric furnaces and the heat pump system. with manual change over.
2ET11700224 – 2H/1C programmable electronic manual changeover
thermostat with subbase.
TYPICAL INSTALLATION
THERMOSTAT WEATHERPROOF
DISCONNECT
TO 48” OVERHEAD
SWITCH
POWER CLEARANCE
TO SUPPLY
INDOOR NEC
BLOWER CLASS 1 12” REAR AND
WIRING SIDES
NEC
CLASS 2
WIRING
TO COIL
NOTE: All outdoor wiring must be weatherproof Seal opening(s) with permagum
or equivalent
ALL WIRING TO BE IN ACCORDANCE WITH NATIONAL ELECTRIC CODE AND/OR LOCAL CODES
INDOOR UNIT 3 OUTDOOR UNIT
ELECTRIC HEATER ACCESSORY
GRD.
LUG
CIRCUIT
BREAKER4
POWER WIRING
2 Terminal not available on all thermostats. 208/230-1-60
3 For typical field wiring with N*VS variable speed
air handler, see N*VS instructions. POWER WIRING
4 Connect power wiring to terminal block on units POWER WIRING 24V CONTROL WIRING (NEC CLASS 2)
without electric heat or units without a circuit breaker.. 208/230-1-60
G-UA COIL
N-AH
BLOWER/
G+FD COIL
UPFLOW
DOWNFLOW
HORIZONTAL
G+FD COIL
F2RC / F2FC OR
F2RP / F2FP
FAN COIL
UNITS
UPFLOW
HORIZONTAL