036-21031-001 Rev C (07/00)

DESCRIPTION

TECHNICAL These high efficiency EFH Series heat pump units are the outdoor part of
a versatile system designed to economically heat and cool a home or
small business. The compact design of these outdoor units make them

GUIDE ideal for ground or roof installation. The units contain enough refrigerant
charge for the outdoor unit, a matched indoor coil and 15 feet of intercon-
necting piping.
EFH heat pumps can be custom-matched with one of YORK's two lines of
evaporator blower sections, each designed to serve a specific function.
® Electric heaters are available for both, in a variety of sizes.
For Add-On applications, the indoor coil may be applied in the supply duct
of a conventional gas, oil or electric furnace. The heat pump will be the pri-
mary source of heat for the building with the furnace operating only when
the heating requirement exceeds the capacity of the heat pump.
FEATURES
QUALITY CONDENSER COILS - The coil is constructed of copper tube
STELLAR PLUSTM and hardened black coated aluminum fins for durability and long lasting
efficient operation. The fins on the unit are protected with a decorative
MODELS: E*FH018 THRU E*FH060 grille.
DURABLE FINISH - Cabinet is made of pre-painted steel. The pre-treated
flat galvanized steel provides a better paint to steel bond, which resists
SPLIT-SYSTEM HEAT PUMPS corrosion and rust creep. Special primer formulas and glossy earth tone
finish insure less fading when exposed to sunlight.
Nominal Capacity: 18 thru 60 MBH
LOWER INSTALLED COST - Installation time and costs are reduced by
Nominal Efficiency: 12.00 SEER the fully exposed refrigerant connections and the single panel covering of
the electrical controls. The small base dimension means smaller mounting
pads or less materials required for mounting, lowering installation costs.
COMPRESSOR - 2 - 5 ton models are equipped with scroll compressors
which are internally protected against high pressure and temperature.
This is accomplished by the simultaneous operation of high pressure relief
valve and a temperature sensor which protect the compressor if undesir-
able operating conditions occur. The compressor is protected by a 10 year
limited warranty.
COMPLETE SYSTEM CONTROL - These heat pump units utilize the
unique YorkGuard V microprocessor control system to provide optimal
comfort control and assure reliable operation. The YorkGuard V control
system continuously monitors the space environment to maintain optimum
efficiency. It initiates defrost only when necessary to further reduce heat-
ing costs and improve reliability. Supplemental heat can only operate
below the balance point and then only upon need. In the event of improper
operating conditions (high temperature and high pressure), the YorkGuard
V will shut the system down to extend the life of the heat pump. Rapid
cycling is prevented by use of an integral anti-recycle timer. Loss of
charge protection is provided by a discharge temperature sensor and
internal compressor overloads.
Finally the YorkGuard V control provides system diagnostics to aid the
service technician, minimizing repair time and cost. The YorkGuard V con-
trol even stores important information for use during servicing and has a 5
year warranty.
LOW OPERATING SOUND LEVEL - The discharge air from the top
mounted fan is blown up away from the structure and any landscaping
carrying the normal operating noise up away from the living area. The rigid
top panel effectively isolates any motor sound. Isolator mounted compres-
sor and the rippled fins of the condenser coil muffle the normal fan motor
and compressor operating sounds.

FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE


036-21031-001 Rev C(07/00)

COOLING CAPACITY - With Air Handler Coils


AIR HANDLER COOLING*
UNIT
COIL MODEL RATED NET MBH SEER/
MODEL
MODEL† ELECTRIC HEAT KW W
CFM
KW SEER
TXV
EER
TOTAL SENS.
E*FH WITH SINGLE SPEED
N1AHB08 2,5,7.5,10 17 G2FD024S17 650 19.0 14.3 1.7 12.05 --- 10.65
E4FH018
N1AHB08 2,5,7.5,10 17 G2FD030S17 650 19.4 14.6 1.8 12.15 --- 10.70
N1AHB08 2,5,7.5,10 17 G2FD024S17 800 23.4 17.6 2.2 12.10 --- 10.85
E4FH024 N1AHB08 2,5,7.5,10 17 G2FD030S17 850 23.4 17.6 2.2 12.10 --- 10.85
N1AHB08 2,5,7.5,10 14 G2FD035(H)14 850 23.4 17.6 2.2 12.10 --- 10.85
E4FH030 N1AHB12 5,7.5,10,15,18 17 G2FD036S17 1000 29.0 21.8 2.9 --- 12.40 10.65
E4FH036 N1AHB12 5,7.5,10,15,18 17 G2FD036S17 1200 34.6 25.6 3.30 -- 12.00 10.50
N1AHC16 5,7.5,10,15,20 21 G2FD042S21 1400 40.0 29.6 3.81 -- 12.00 10.50
E4FH042
N1AHC16 5,7.5,10,15,20 21 G2FD048S21 1425 41.0 30.3 3.80 -- 12.40 10.80
N1AHC16 5.7.5,10,15,20 21 G2FD048S21 1600 47.5 35.6 4.6 -- 12.00 10.50
E4FH048
N1AHD20 5.7.5,10,15,20,25,30 24 G2FD060S24 1620 48.0 36.0 4.6 -- 12.40 10.85
N1AHD20 7.5,10,15,20,25,30 24 G2FD060S24 1850 58.0 42.0 5.42 -- 12.00 10.70
E4FH060
N1AHD20 7.5,10,15,20,25,30 24 G2FD061H24 1875 58.5 41.5 5.46 -- 12.20 10.70
E*FH WITH VARIABLE SPEED
E4FH018 N1VSB12 5,7.5,10,15,18 17 G2FD024S17 650 19.4 14.3 1.7 13.80 --- 11.70
E4FH024 N1VSB12 5,7.5,10,15,18 17 G2FD024S17 800 24.0 18.0 2.0 14.00 --- 12.00
N1VSB12 5,7.5,10,15,18 17 G2FD030S17 1000 29.0 21.8 2.7 --- 13.00 11.20
E4FH030
N1VSB12 5,7.5,10,15,18 17 G2FD036S17 1000 29.2 21.9 2.7 --- 13.50 11.40
E4FH036 N1VSB12 5,7.5,10,15,18 17 G2FD036S17 1200 35.0 25.9 3.13 -- 13.30 11.20
N1VSC16 5,7.5,10,15,20 21 G2FD042S21 1400 40.5 30.0 3.62 -- 13.30 11.20
E4FH042
N1VSC16 5,7.5,10,15,20 21 G2FD048S21 1425 41.5 30.7 3.64 -- 13.50 11.40
N1VSC16 5.7.5,10,15,20 21 G2FD048S21 1600 48.0 36.0 4.3 --- 13.40 10.50
E4FH048
N1VSD20 5.7.5,10,15,20,25,30 24 G2FD060S24 1650 49.0 36.8 4.3 --- 13.80 10.80
N1VSD20 7.5,10,15,20,25,30 24 G2FD060S24 1850 60.5 42.9 5.22 -- 13.00 11.60
E4FH060
N1VSD20 7.5,10,15,20,25,30 24 G2FD061H24 1875 59.5 41.5 5.00 -- 13.50 11.90
E*FH WITH F2RP BLOWER COIL UNITS
F2RP/FP018 5,8,10 18 -- 650 18.0 13.5 1.7 12.00 --- 10.75
E4FH018
F2RP/FP024 5,8,10 18 -- 650 19.0 14.3 1.8 12.50 --- 10.44
F2RP/FP024 5,8,10 18 -- 800 23.4 17.6 2.2 12.00 --- 10.35
E4FH024
F2RP/FP030 5,8,10,15 18 -- 800 23.8 17.9 2.3 12.50 --- 10.55
F2RP/FP030 5,8,10,15 18 --- 1035 28.2 21.2 2.8 --- 12.00 10.30
E4FH030
F2RP/FP036 5,8,10,15 21 --- 1035 29.0 21.8 3.0 --- 12.00 10.30
F2RP036 5,8,10,15 18 -- 1250 34.6 25.6 3.26 -- 12.10 10.60
E4FH036
F2RP042 5,8,10,15 21 -- 1250 34.6 25.6 3.30 -- 12.10 10.50
F2RP042 5,8,10,15 21 -- 1400 40.0 29.6 3.85 -- 12.00 10.40
E4FH042
F2FP048 10,15,20,25 24 -- 1600 41.0 30.3 3.80 -- 12.40 10.80
F2FP048 10,15,20,25 24 -- 1600 47.0 35.3 4.6 --- 12.00 10.45
E4FH048 F2V060 10,15,20,25 24 -- 1600 48.5 36.4 4.3 --- 13.00 11.60
F2FP060 10,15,20,25 24 -- 1600 47.5 35.6 4.8 --- 12.00 10.35
F2FP060 10,15,20,25 24 -- 1850 57.0 42.2 5.48 -- 11.60 10.40
E4FH060
F2FV060H24 10,15,20,25 24 -- 1875 59.0 43.0 5.09 -- 13.00 11.60
NOTES:

*. Standard Cooling Operation is limited to 50 ° F outdoor ambient.


†. To meet insulating R-value requirements, substitute F2FP for F2RP models. All ratings remain the same.
Certified in accordance with the Unitary Small Equipment certification program, which is based on ARI Standard 210/240.

KW includes compressor, outdoor fan and indoor blower motor watts. Add-on coils include 365 watts/1000 CFM for blower motor.
Integrated heating capacities include the effect of defrost cycles in the temperature range where they occur.

SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTUs during a normal annual usage period for cooling divided
by the total electric power input in watt-hours during the same period.

EER (Energy Efficiency Ratio) is the total cooling output in BTUs at a 95 ° F outdoor ambient divided by the total electric power in
watt-hours at those conditions.

(--) = Not Applicable. .

2 Unitary Products Group


036-21031-001 Rev C (07/00)

COOLING CAPACITY - With Upflow, Downflow and Horizontal Furnace and Coils
FURNACE* COOLING
UNIT COIL†
NOMINAL RATED NET MBH SEER/
MODEL W MODEL KW SEER EER
AIRFLOW CFM TOTAL SENS. TXV‡
E*FH WITH HORIZONTAL FURNACE AND COILS
14,17 G1UA024S14,17 650 18.8 14.1 1.8 12.00 --- 10.55
800 14,17 G2FD024S14, 17 650 19.0 14.3 1.8 12.50 --- 10.65
E4FH018
1000 14 G1UA030S14 650 19.0 14.3 1.8 12.05 --- 10.65
14,17 G2FD030S14, 17 650 19.4 14.6 1.8 12.15 --- 10.85
14,17 G2FD024S14,17 800 23.4 17.6 2.2 12.10 --- 10.85
** G1HD024 800 23.4 17.6 2.2 12.10 --- 10.75
800
14 G1UA030S14 850 23.0 17.3 2.2 12.00 --- 10.85
E4FH024 1000
17,21 G1UA036S17,21 850 23.8 17.9 2.2 12.20 --- 10.85
1200
17 G2FD030S17 850 23.4 17.6 2.2 12.10 --- 10.80
14 G2FD035S14 850 23.4 17.6 2.2 12.10 --- 10.80
17 G1FD030S17 1000 28.2 21.2 2.9 --- 12.00 10.35
14 G2FD035S14 1000 29.0 21.8 2.9 --- 12.00 10.35
1000
17,21 G1UA036S17,21 1025 28.2 21.2 2.9 --- 12.00 10.35
E4FH030 1200
** G1HD036 1025 29.0 21.8 2.9 --- 12.00 10.45
1400
17 G2FD036S17 1025 29.0 21.8 2.9 --- 12.40 10.65
21 G2FD036S21 1025 29.0 21.8 2.9 --- 12.40 10.65
21,24 G1UA048S21,24 1225 35.4 26.2 3.31 -- 12.50 10.70
17 G1UA048S17 1225 35.0 25.9 3.30 -- 12.10 10.60
1200
21 G2FD42S21 1225 34.8 25.8 3.30 -- 12.20 10.55
E4FH036 1400
17 G2FD046S17 1225 35.0 25.9 3.30 -- 12.10 10.60
1600
21 G2FD036S21 1225 34.6 25.6 3.30 -- 12.00 10.50
17 G2FD036S17 1225 34.6 25.6 3.30 -- 12.00 10.50
21 G2FD042S21 1400 40.0 29.6 3.81 -- 12.00 10.50
1400 21,24 G1UA048S21,24 1425 40.5 30.0 3.79 -- 12.40 10.70
E4FH042 1600 17 G1UA048S17 1400 40.5 30.0 3.80 -- 12.25 10.65
2000 17 G1UA046S17 1400 40.5 30.0 3.80 -- 12.25 10.65
21,24 G2FD048S21,24 1425 41.0 30.3 3.80 -- 12.40 10.80
21,24 G2FD048S21, 24 1600 47.5 35.6 4.6 --- 12.00 10.50
17 G1UA048S17 1600 47.0 35.3 4.6 --- 12.00 10.40
1600
E4FH048 21 G1UA048S21 1620 47.0 35.3 4.6 --- 12.00 10.50
2000
21,24 G1UA060S21, 24 1620 47.5 35.6 4.6 --- 12.20 10.75
24 G2FD060S24 1620 48.0 36.0 4.6 --- 12.40 10.75
21,24 G1UA060S21,24 1850 57.0 41.0 5.48 -- 11.70 10.40
E4FH060 2000 24 G2FD060S24 1850 58.0 42.0 5.42 -- 12.00 10.70
24 G2FD061H24 1850 58.5 41.5 5.46 -- 12.20 10.70

*. Refer to Quick Selection Chart for specific furnace match-up.


†. Refer to coil installation guide for proper coil application.
‡. Refer to system charging procedure for proper TXV match-up.
See Notes on Page 2

E*FH SOUND RATING


MODEL DECIBELS
018 72*
024 73*
030 74*
036 74*
042 74*
048 76*
060 76*

*.Compressor Blanket Factory Installed. CERTIFICATION APPLIES


ONLY WHEN THE COMPLETE
SYSTEM IS LISTED WITH ARI
Rated in accordance with ARI Standard 270.

Unitary Products Group 3


036-21031-001 Rev C(07/00)

HEATING PERFORMANCE - Air Handlers and Multi-position Coils*


ARI HEATING OUTDOOR TEMP
UNIT COIL
47 °F 17 °F HSPF -3 °F 7°F 17°F 27°F 37°F 47°F 57°F
MODEL MODEL
MBH COP MBH COP STD. V. S. MBH KW MBH KW MBH KW MBH KW MBH KW MBH KW MBH KW
E*FH WITH (VARIABLE SPEED & STANDARD) AIR HANDLER COILS
F2RP/FP018 17 3.00 10 2.00 6.8 -- 4 1.3 7.8 1.27 10 1.35 12.3 1.60 15.2 1.6 17 1.61 17.6 1.66
F2RP/FP024 19.5 3.20 11.3 2.10 7.5 -- 4.5 1.25 8 1.25 11.3 1.36 12.7 1.57 15.5 1.68 19.5 1.59 19.6 1.65
E4FH018 G2FD024S14, 17 19.0 3.32 11.6 2.00 7.6 8 6 1.51 8 1.25 11.6 1.36 12.9 1.40 16.5 1.52 19.8 1.59 19.6 1.65
G2FD030S17 19.8 3.40 1.16 2.24 7.5 -- 6.2 1.52 8.2 1.23 11.6 1.69 12.8 1.38 16.4 1.5 19.8 1.79 19.6 1.63
G2FD035S14 19.8 3.40 1.16 2.24 7.5 -- 6.2 1.5 8.2 1.25 11.6 1.69 12.9 1.39 16.6 1.51 19.8 1.79 19.8 1.64
F2RP/FP024 24 3.32 12.9 2.20 8 -- 6.6 1.55 11 1.78 12.9 1.7 16 1.85 18.8 1.87 24 1.8 26.6 2.07
F2RP/FP030 24 3.32 12.9 2.20 8 -- 6.8 1.56 11.4 1.76 12.9 1.78 16.2 1.84 19 1.85 24 2.07 26.8 2.08
E4FH024 G2FD024S14, 17 23.8 3.40 13.5 2.30 8 8.1 6.6 1.58 11.6 1.75 13.5 1.78 16.3 1.82 19.1 1.85 23.8 2.07 26.6 2.1
G2FD030S17 24 3.26 13.6 2.18 8 -- 6.8 1.6 11.4 1.73 13.6 1.75 16.2 1.80 19.2 1.83 24 2.08 26.8 2.08
G2FD035S14 24 3.26 13.6 2.18 8 -- 6.9 1.57 11.6 1.74 13.6 1.77 16.4 1.80 19.4 1.8 24 2.06 26.8 2.1
F2RP/FP030 28 3.33 17 2.33 8 -- 9.6 1.98 13.1 2.1 16.6 2.21 20.3 2.33 24.3 2.46 28 2.56 32.9 2.7
F2RP/FP036 28 3.33 17 2.33 8 -- 9.6 1.95 13.1 2.09 16.7 2.21 20.2 2.34 24.4 2.48 28 2.57 33 2.71
E4FH030 G2FD030S17 28 3.33 17 2.33 8 8.2 9.8 2.06 13.1 2.14 16.5 2.2 19.9 2.29 23.9 2.4 28 2.5 32.7 2.55
G2FD035S14 28 3.33 17 2.33 8 -- 9.4 2.06 13.2 2.14 16.6 2.3 20 2.31 24 2.41 28 2.6 33 2.6
G2FD036S17, 21 28 3.33 17 2.33 8 8.2 9.9 2.02 13.3 2.15 16.6 2.19 21 2.41 23.8 2.4 28 2.6 33.4 2.65
F2RP/FP036 36.0 3.10 21.8 2.30 8.0 -- 12.5 2.36 17.1 2.57 21.8 2.78 26.5 2.99 31.7 3.21 36.0 3.40 41.4 3.56
F2RP/FP042 36.0 3.10 21.8 2.30 8.0 -- 12.5 2.35 17.2 2.57 21.8 2.78 26.4 2.99 31.6 3.21 36.0 3.40 41.5 3.57
E4FH036 G2FD042S21 36.0 3.38 21.8 2.26 8.0 -- 12.5 2.63 17.1 2.73 21.8 2.83 26.5 2.93 31.7 3.04 36.0 3.12 41.7 3.18
G2FD046S17 36.0 3.38 21.8 2.26 8.0 -- 12.5 2.63 17.2 2.73 21.8 2.83 26.4 2.93 31.7 3.04 36.0 3.12 41.4 3.16
G2FD036S17,21 36.0 3.40 21.8 2.28 8.0 8.1 12.5 2.60 17.1 2.70 21.8 2.80 26.5 2.90 31.7 3.02 36.0 3.10 41.7 3.16
F2RP/FP042 42.0 3.30 25.2 2.20 7.8 -- 13.4 3.08 19.3 3.22 25.2 3.36 31.1 3.50 37.7 3.63 42.0 3.73 48.5 3.85
F2FP048 42.0 3.58 25.2 2.32 8.0 -- 12.5 2.98 18.8 3.08 25.2 3.18 31.6 3.29 38.6 3.40 42.0 3.44 50.4 3.56
E4FH042 G2FD042S21 41.5 3.40 25.0 2.26 8.0 8.1 12.5 2.94 18.8 3.09 25.0 3.24 31.2 3.39 38.2 3.55 41.5 3.58 49.6 3.73
G2FD046S17 41.5 3.40 25.0 2.24 8.0 -- 13.4 3.05 19.2 3.16 25.0 3.27 30.8 3.38 37.3 3.51 41.5 3.58 47.8 3.66
G2FD048S21,24 42.0 3.58 25.2 2.32 8.0 8.0 12.4 2.98 18.8 3.08 25.2 3.18 31.6 3.29 38.7 3.41 42.0 3.44 50.4 3.56
F2FP048 47.5 3.30 28.4 2.20 8.1 -- 17 3.54 22.6 3.66 28.4 3.78 34.2 3.91 39 3.76 47.5 4.03 53.5 4.13
F2FP060 47.5 3.30 28 2.20 8.1 -- 18 3.5 22.8 3.58 28 3.75 34.6 3.95 40 3.8 47.5 4.15 54 4.3
E4FH048
G2FD048S21, 24 48 3.48 28 2.34 8.1 8.2 17 3.52 22.6 3.6 28 3.76 34.2 3.96 40 3.9 48 4.04 53.5 4.25
G2FD060S24 48.5 3.30 28.4 2.20 8.1 8.2 18 3.55 22.8 3.65 28.4 3.78 34.6 3.96 40 3.8 48.5 4.03 54 4.26
F2FP060 60.0 3.40 40.0 2.40 8.0 -- 18.7 4.08 26.1 4.44 40.0 4.80 40.7 5.16 49.0 5.55 60.0 5.94 68.6 6.25
F2FV060 60.0 3.00 40.0 2.60 -- 8.3 17.6 3.93 24.6 4.11 40.0 4.29 38.6 4.47 46.6 4.68 60.0 4.93 66.1 5.07
E4FH060
G2FD060S24 60.0 3.50 40.0 2.50 8.2 8.3 18.9 3.94 26.0 4.21 40.0 4.48 40.0 4.75 48.1 5.05 60.0 5.39 67.8 5.61
G2FD061H24 62.0 3.60 41.0 2.60 8.4 – 20.2 4.07 26.9 4.28 41.0 4.49 40.5 4.70 48.3 4.95 62.0 5.22 67.5 5.39

*. Heating MBH based on 70 ° DB entering indoor air, 72% RH outdoor air with 25 ft. of interconnecting piping and no electric heat
operation.

COP equals MBH output divided by (total KW input x 3.412).

HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by
the total electric power input during the same period.

(See NOTES on Page 2)

4 Unitary Products Group


036-21031-001 Rev C (07/00)

HEATING PERFORMANCE - Furnace Coils*


ARI HEATING OUTDOOR TEMP
UNIT COIL
47 °F 17 °F HSPF -3 °F 7°F 17°F 27°F 37°F 47°F 57°F
MODEL MODEL
MBH COP MBH COP STD. V. S. MBH KW MBH KW MBH KW MBH KW MBH KW MBH KW MBH KW
E*FH WITH (VARIABLE SPEED & STANDARD) FURNACE COILS
G1HD024 18 3.08 9.9 2.00 7.1 -- 6.2 1.1 9 1.15 9.9 1.25 13.6 1.4 16 1.5 18 1.6 20 1.75
E4FH018 G1UA024S17 19.0 3.24 11.4 2.16 7.6 -- 6.6 1.09 9.2 1.1 11.4 1.25 13.8 1.45 16.6 1.54 19.6 1.64 22 1.74
G1UA030S14 19.0 3.32 11.6 2.20 7.6 -- 6.6 1.08 9.2 1.15 11.6 1.27 14.2 1.43 16.8 1.5 19.8 1.62 22.4 1.76
G1HD024 24 3.16 12.2 2.00 8 -- 7.2 1.57 10 1.67 12.2 1.76 16.4 1.9 19.6 1.95 24 2.05 27.4 2.17
E4FH024 G1UA030S17 23.6 3.16 13.4 2.14 8 -- 7.6 1.5 10.4 1.65 13.4 1.76 16.6 1.85 19.8 1.97 23.6 2.03 27.6 2.16
G1UA036S17, 21 24 3.26 13.6 2.18 8 -- 7.6 1.52 10.4 1.6 13.6 1.76 16.8 1.9 20 1.9 24 2.03 28.2 2.18
G1HD036 28 3.33 17 2.3 8 -- 9.8 2.08 13.1 2.14 16.6 2.1 19.8 2.2 23.8 2.38 28 2.5 39.8 2.55
E4FH030 G1UA036S14 28 3.33 17.2 2.3 8 -- 10 2.07 13.2 2.15 16.8 2.3 19.9 2.3 23.9 2.39 28 2.5 34 2.57
G1UA036S17, 21 28 3.33 17.2 2.3 8 -- 10.1 2.08 13.3 2.17 17 2.4 20.1 2.4 24.1 2.4 28 2.55 34.2 2.6
G1UA048S21,24 35.6 3.46 21.8 2.30 8.0 -- 12.8 2.61 17.3 2.69 21.8 2.78 26.3 2.86 31.3 2.95 35.6 3.02 41.2 3.07
E4FH036
G1UA048S17 36.0 3.38 21.8 2.26 8.0 -- 12.5 2.63 17.2 2.73 21.8 2.83 26.4 2.93 31.7 3.04 36.0 3.12 41.4 3.16
G1UA048S21,24 42.0 3.50 25.2 2.30 8.0 -- 12.5 2.98 18.9 3.09 25.2 3.21 31.5 3.33 38.5 3.47 42.0 3.52 50.3 3.66
E4FH042
G1UA048S17 41.5 3.40 25.0 2.24 8.0 -- 13.4 3.05 19.2 3.16 25.0 3.27 30.8 3.38 37.3 3.51 41.5 3.58 47.8 3.66
G1UA048S21, 24 48 3.40 28 2.30 8 -- 16.1 3.23 22.1 3.41 28 3.57 34 3.72 40.6 3.91 48 4.06 54.8 4.16
E4FH048
G1UA060S21, 24 48 3.40 28 2.30 8 -- 16.2 3.24 22.2 3.42 28 3.55 34 3.7 40.6 3.92 48 4 54.9 4.18
E4FH060 G1UA060S21,24 60.0 3.40 40.0 2.40 8.0 -- 18.9 3.95 26.0 4.21 33.0 4.48 40.1 4.74 48.1 5.04 57.0 5.39 67.8 5.60

*. Heating MBH based on 70 ° DB entering indoor air, 72% RH outdoor air with 25 ft. of interconnecting piping and no electric heat
operation.

COP equals MBH output divided by (total KW input x 3.412).

HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by
the total electric power input during the same period.

(See NOTES on Page 2)

Unitary Products Group 5


036-21031-001 Rev C(07/00)

ACCESSORIES
Refer to Price Manual for specific model numbers. Blower -Off Delay - (2FD06700224) - Available to increase effi-
ciency. Installs on indoor section to maintain blower operation for
Service Analyzer - Provides on-the-spot system analysis and/or
approximately 1 minute on shutdown. Standard on most models.
trouble shooting capacity. Order 025-25980-000 from Source 1 Parts
Department. Room Thermostats - A wide selection of matching thermostats is
available to provide features required for any installation.
Outdoor Thermostats (2TD06700124) - Consists of an adjustable
outdoor thermostat and a relay in a vented enclosure. It provides 2TH11702224 – 2H/1C with subbase, manual change over non-elec-
additional second stage control of the supplemental resistance heat. tronic thermostat.
TXV Kit - 1TV0700 Series TXV must be used to obtain system per- 2TH11702424 – 2H/1C with subbase, automatic change over non-
formance. See Tabular Data Instructions for details. electronic thermostat.
Add-On Control (2AC02700801) - Provides interface between gas, 2ET11704324 – 2H/1C non-programmable electronic thermostat,
oil or electric furnaces and the heat pump system. with manual change over.
2ET11700224 – 2H/1C programmable electronic manual changeover
thermostat with subbase.

TYPICAL INSTALLATION

THERMOSTAT WEATHERPROOF
DISCONNECT
TO 48” OVERHEAD
SWITCH
POWER CLEARANCE
TO SUPPLY
INDOOR NEC
BLOWER CLASS 1 12” REAR AND
WIRING SIDES

NEC
CLASS 2
WIRING

TO COIL

24” SERVICE ACCESS


CLEARANCE

NOTE: All outdoor wiring must be weatherproof Seal opening(s) with permagum
or equivalent

6 Unitary Products Group


036-21031-001 Rev C (07/00)

TYPICAL FIELD WIRING - (AIR HANDLER / ELECTRICAL HEAT)

ALL WIRING TO BE IN ACCORDANCE WITH NATIONAL ELECTRIC CODE AND/OR LOCAL CODES
INDOOR UNIT 3 OUTDOOR UNIT
ELECTRIC HEATER ACCESSORY

S1* * BONNET SENSOR


THERMOSTAT S2* CONNECTIONS FOR
ADD-ON SYSTEM
O O O
X or L X or L
R R R
B or C C B or C
Y Y Y CONTACTOR
W W
G G W2/60 GRD.
W2 W1/66 T2 T1 SCREW
W1 M
L2 L1

GRD.
LUG

CIRCUIT
BREAKER4
POWER WIRING
2 Terminal not available on all thermostats. 208/230-1-60
3 For typical field wiring with N*VS variable speed
air handler, see N*VS instructions. POWER WIRING
4 Connect power wiring to terminal block on units POWER WIRING 24V CONTROL WIRING (NEC CLASS 2)
without electric heat or units without a circuit breaker.. 208/230-1-60

Unitary Products Group 7


MATCHING INDOOR COMPONENTS
Add-On Coils - For Furnace Application Air Handlers - For Non-Furnace Application

G-UA COIL

N-AH
BLOWER/
G+FD COIL

UPFLOW
DOWNFLOW
HORIZONTAL

G+FD COIL

F2RC / F2FC OR
F2RP / F2FP
FAN COIL
UNITS

UPFLOW
HORIZONTAL

Subject to change without notice. Printed in U.S.A. 036-21031-001 Rev C (07/00)


Copyright © by Unitary Products Group 2000. All rights reserved. Supersedes: 036-21031-001 B (05/00)