AEGIS™-XLT

Conventional Fire Alarm-Suppression Control Unit

Effective: May 2020


K-84-300

FEATURES
• Suppression Focused Control Unit • Listed for use with Kidde®, Fenwal® and Chemetron®
• Advanced Features for LP CO2, Spurt Mode and Water agent release devices including Control Heads and
Mist Cycling Initiators
• NEMA 1, 4 and 12 Enclosures • Built-in Class A and Class B Circuitry
• Triple R Redundancy Provides Maximum Protection • Sophisticated Programmable NACs
Against Inadvertent Release • Independently Programmable Agent Releasing Circuits
• Agency Approvals • 6 Abort Modes
• FM Approved • 5.4 Amp Power Supply Unit
• UL Listed to ANSI 864, 10th edition
• 120/240 V, 50/60 Hz AC Input
• California State Fire Marshal
• City of New York Fire Department • Easy-to-Use User Interface and Display
• Compliant with NFPA 72 • Password Protected
• Licensed for entry into Kingdom of Saudi Arabia • Digital Release Countdown
• Listed for a Wide Range of Suppression Systems • Battery Voltage and Charging Current Display
• Kidde® ECS HFC-227ea and FK-5-1-12 • Charging Capacity of 68 AH
• Kidde® ADS HFC-227ea and FK-5-1-12 • Extensive Diagnostics
• Kidde® HP CO2
• Kidde® LP CO2
• Kidde® IG Argonite & Nitrogen
• Kidde® FE-13
• Fenwal® Spheres
• Fenwal® BDCs
• Sprinkler Supervisory Service
• Deluge, Pre-Action, Foam, Foam-Water Systems

DESCRIPTION
The Kidde® AEGIS™-XLT is a Conventional Single Hazard
Agent Releasing Unit which provides advanced
configuration flexibility useful for Spurt, water mist cycling
and LP CO2 applications and is available in NEMA 1,
NEMA 4 and NEMA 12 variants for applications in
commercial and industrial environments.
The AEGIS-XLT is well equipped to handle all special
hazard extinguishing systems due to the high degree of
programming flexibility provided and the following full
complement of input and output circuits:
• Three (3) Class A or Class B Detection Circuits
• Two (2) Class A or Class B Supervisory Circuits
• Fourth Detection Circuit Option for Contact Closure
Devices*
• One (1) Class A or Class B Manual Release Circuit
• One (1) Class A or Class B Abort Input Circuit
• Three (3) Class A or Class B NACs
• Two (2) Class B Agent Release Circuits
• Option to Use NAC 1 Circuit as Third Release Circuit
• Three (3) Programmable and 1 Trouble Form-C
Relays
• *Fourth Detection Circuit must contain normally open contact
closure device (not 2-wire smoke detector).
DETECTION CIRCUITS
The Detection Circuits support Conventional 700 Series, Activation of the Agent Release Circuits can either be
CPD-705x Ionization Smoke, PSD-715x Photoelectric instantaneous or delayed per programmed time delay
Smoke and THD-705x Heat Detectors as well as upon receipt of Manual Release input. Agent release can
Normally Open contact closure type devices. Two circuits be temporarily delayed by activating the Abort Circuit.
are dedicated to the main suppression function and can Subsequent activation of the Manual Release overrides
be programmed to activate the release circuits by either an Abort in process. After a Manual Release has been
single-shot or cross-zone input. The user configuration activated, activating an Abort will have no effect. The
allows automatic release via detection to be delayed from Abort input can be programmed for 5 modes of operation
0 to 240 seconds in 1-second intervals or from 0 to 24 or disabled entirely. These include the UL 10-second
minutes in 1 minute intervals and also allows a choice of mode, the full-delay mode, the IRI mode or two NYC
which of the Agent Release Circuits to activate. modes. Aborts can also be programmed to be applicable
The third Detection Circuit is programmable for either for either one (ARC 1) or both Agent Release Circuits
Waterflow or as an independent Detection circuit. When thereby allowing use with Deluge/Pre-Action systems.
programmed for Waterflow, Notification Appliance NOTIFICATION APPLIANCE CIRCUITS (NAC)
Circuits can be programmed as Non-Silenceable as The three Notification Appliance Circuits are rated 1.5
required by certain jurisdictions. Additionally, the Amps each and accept polarized 24 VDC regulated
Supervisory 1 circuit can be configured to be the fourth Notification Appliances. Each circuit is driven
detection circuit. This fourth detection circuit must contain independently and is user configurable for First Alarm,
normally open contact closure devices (not 2-wire smoke Pre-Release, and Releasing. Several coded patterns are
detectors). supported including 60 BPM, 120 BPM, Temporal, and
SUPERVISORY CIRCUITS Continuous.
The Supervisory Circuits accept Normally Open contact The control unit supports appliances that provide the
closure type devices such as pressure switches on the option to use silenceable horns and non-silenceable
agent cylinders or on the water or air pipe network. The strobes on the same NAC. Multiple NAC circuits
system configuration enables the supervisory input to be (connected to audible devices only) programmed with the
a participant in the suppression function. For example, same master code pattern are synchronized, regardless
low air supervisory can be included with detection for of any differing starting times that preceded their
release of pre-action systems as required by certain concurrent operation. The NACs configuration includes a
jurisdictions. user-selectable intelligent synchronization feature which
MANUAL RELEASE AND ABORT CIRCUITS allows a silenceable horn to be shut off while the strobe
continues to flash in synchronized fashion (using Cooper
Both the Manual Release and Abort Circuits accept
Wheelock notification applicances).
Normally Open contact closure type devices.
SUPERVISORY 1/ MANUAL WATERFLOW/ DETECTOR
SUPERVISORY 2 DETECTOR 4 ABORT RELEASE DETECTOR 3 INPUT 2

TB7 TB6 TB5 TB4 TB3 TB2


TROUBLE TB8
RELAY DETECTOR
TB1
RELAY 3 INPUT 1
TB9

RELAY 2 TB10

RELAY 1 TB11

BATT OUT TB12

AC SUPPLY SELECT SWITCH (S6)


NAC 1/ARC 3
TB19

AC IN TB14 TB15 TB16 TB17 TB18 NAC 2

TB13

RELEASE 1 RELEASE 2 AUX NAC 3


ARC 1 ARC 2 24 VDC

Figure 1. Printed Circuit Board (PCB)

-2-
BUILT-IN CLASS A AND B CIRCUITRY PROGRAMMABLE RELAYS
For the input and NAC circuits, the choice of Class A or Of the 4 relays, three are user-programmable for a
Class B supervision is made at site on the board itself by variety of alarm related conditions and the fourth is a
selecting the terminals used for wiring. Neither dedicated trouble relay. All relay contacts are rated 3.0
conversion boards nor additional hardware nor jumper Amps at 30 VDC/120 VAC (resistive).
selection is required for this purpose. SPURT MODE OPERATION
AGENT RELEASE CIRCUITS (ARC) When programmed for Spurt mode, operation of the
These circuits can be programmed for activation by Detector 3 or Abort (programmable) Input allows the end
different inputs, with independent time delays and abort user to selectively energize any or all of the three sole-
modes to fire combinations of two of the following noid outputs instantaneously and continuously as long as
releasing devices: the input is manually held in the activated condition.
There is no automatic timing function associated with the
• 1 or 2 Kidde®, Fenwal® or Chemetron® Continuous
Spurt option. Only momentary/spring-return type contact
and Momentary Solenoid Control Heads
devices or normally-open contacts which automatically
• 1 Kidde Actuator or Fenwal Initiators reset should be used. All Spurt events are non-latching
• 1 Factory Mutual Release Panel Group 2 Solenoid and will return to the previous mode of operation upon
(Any FM Approved Solenoid Valve rated 16.8W and deactivation of the Detector 3 or Abort (programmable).
below) WATERMIST CYCLING
In other words, operating in tandem, the two circuits can When programmed for Watermist Cycling, any or all of
release: the Agent Release Circuits may be configured for
repetitions of Agent ON time followed by Agent OFF time.
• 1 or 2 Control Heads on ARC 1 and 1 or 2 Control After the completion of those repetitions, followed by a
Heads on ARC 2 wait time period, Watermist Cycling can be repeated a
• 1 or 2 Control Heads on ARC 1 and 1 Actuator or specified number of times.
Initiators on ARC 2 or vice-versa
• 1 or 2 Control Heads on ARC 1 and 1 FM Sprinkler POWER-LIMITED CIRCUITRY
Solenoid on ARC 2 or vice-versa All circuits are inherently power-limited. Agent Release
• 1 Actuator or Initiators on ARC 1 and 1 Actuator or Circuits (ARCs) can be configured for power-limited or
Initiators on ARC 2 non-power-limited operation. One in-line releasing device
• 1 FM Solenoid on ARC 1 and 1 FM Solenoid on is required for each solenoid on a power limited ARC.
ARC 2 Two (2) in-line releasing devices are included with the
panel; additional in-line releasing devices should be
The control unit supports up to 3 ARCs by configuring ordered using part number 06-220023-001.
NAC 1 as a third ARC. (Actuators or Initiators not
supported on this circuit). This configurability is useful for ROBUST POWER SUPPLY UNIT (PSU)
those jurisdictions where the gaseous suppression agent The AEGIS-XLT features a universal 120/240 V, 50/60
is required to be supplemented with a pre-action system. Hz AC Power Supply Unit with a robust 5.4 Amps of 24
VDC power. Input voltage selection is via a slider switch
TRIPLE-R PROTECTION FOR AGENT RELEASING
with no jumper cutting required. The on-board battery
CIRCUITS (ARCS)
charger is able to charge 24 VDC (2 x 12) batteries of
The ARCs feature a triple failure redundancy safeguard capacity up to 68 AH thereby allowing from 24 hours of
system to protect them from inadvertent activation. The supervision plus 5 minutes of alarm to 90 hours of
Triple-R system requires that in order to activate an ARC, supervision plus 10 minutes of alarm required by some
the main microprocessor issues two release commands jurisdictions.
of opposing polarity via separate channels and that these
commands be combined with a third signal from the AUXILIARY POWER SUPPLY
panel watchdog timer to confirm the microprocessor Up to 1 Amp of auxiliary power at 24 VDC is available to
operation. The Triple-R system ensures that electrical power external 4-wire devices such as Flame Detectors,
transients or disturbances such as power surges that AlarmLine modules, Duct Detectors, etc. The auxiliary
could interfere with the operation of the main power output is resettable.
microprocessor will not inadvertently activate the
connected suppression system. The result is a more
robust and reliable suppression-focused panel.

-3-
ELEGANT USER INTERFACE NEMA 4 AND NEMA 12 ENCLOSURES
The user interface consists of an array of LED Indicators, For Commercial, Outdoor (Weatherproof) and Industrial
Control Switches, a Digital Display, and Buzzer. Over and (Dust Tight and Oil Resistant) applications, the AEGIS-
above the System, Power Supply status, Input circuit XLT is available in NEMA 4 and 12 versions. The NEMA
Alarm and Trouble and Output circuit Trouble LEDs, the 12 enclosure has a door mounted handle for easy
AEGIS-XLT annunciates its suppression state-of-alarm access.
via three additional Pre-Release, Releasing and Post
Release LEDs. Four switches are provided, one each for
Acknowledge, Signal Silence, System Reset and Output
Disable. The 3-digit display provides a countdown of
impending agent release. On command from the user
interface switches, it also indicates the battery open
circuit voltage and charging current.
SIMPLE SITE-SPECIFIC CONFIGURATION
Setting the site-specific configuration is easily done using
the digital display and user interface buttons. To prevent
unauthorized use, the configuration menu is protected by
a user-changeable password. Factory technical support
can provide assistance with lost or forgotten passwords.
Apart from the input voltage selection performed on both
the PSU and main board via a slider switch, no other on-
board settings or jumper cuttings are required.

EXTENSIVE DIAGNOSTICS
Also initiated via the digital display and user interface
switches, the troubleshooting function displays diagnostic AEGIS-XLT (NEMA 4)
codes that assist in determining causes of trouble. A
complete list of diagnostic codes and their meaning ships
factory installed on the inside of the enclosure door for
easy reference.

BACKWARDS COMPATIBILITY
The AEGIS-XLT is backwards compatible and listed for
use with a full range of conventional detectors and alarm
devices as well as suppression accessories from Kidde,
Fenwal and Chemetron. Going forward, this will allow
legacy panels to be replaced with relative ease.

EASY TO INSTALL NEMA 1 CABINET


The NEMA 1 cabinet design allows for easy installation
by fitting between the studs of a standard 16-inch
studded wall. It is large enough to house two 12 VDC, 12
AH batteries and provides up to 2 inches (51 mm) of
wiring and finger space between the circuit board and the
cabinet wall.
The NEMA 1 cabinet options include a flush mounting
trim-ring and a dead-front plate (ordered separately). AEGIS-XLT (NEMA 12)

-4-
TECHNICAL SPECIFICATIONS • Three (3) Notification Appliance Circuits (NACs)
• Hazards Protected - Compatible with polarized 24 VDC regulated
- One Audible-Visual devices
- Rated at 1.5 Amps each
• Power Supply
- Up to 35 synchronized appliances
- 120/240 V, 50/60 Hz (90 to 264 VAC, 47 to 63 Hz) - Configurable as Class A or Class B
AC Main Input - Supervised for ground faults, shorts, and open
- 5.4 Amps at 27 VDC Output circuits
- Battery capacity up to 68 AH @ 24 VDC - Power-limited
- Auxiliary power output rated Class B at 1 Amp at - Common NAC/ARC output disable switch
18.8 - 27.6 VDC (resettable)
• Three (3) or Four (4) Detection Circuits
• Two (2) or Three (3) Agent Release Circuits
- Compatible with ESL/Interlogix 700 Series
- Each compatible with 1 or 2 control heads, or 1
detectors, CPD-705x, PSD-715x, and THD-705x
actuator/initiator, or 1 FM sprinkler solenoid
detectors, as well as Normally Open contact
- Circuits electrically capable of simultaneously
closure type devices. Refer to documents K-70-100
releasing any combination of the above devices
and F-70-63 for details on compatibility and the
- Option to use NAC 1 circuit as ARC 3 circuit
maximum number of devices supported.
(Actuators or Initiators not supported on this circuit)
- Configurable as Class A or Class B
- Factory configured as Class B
- Supervised for ground faults and open circuits
- Supervised for ground faults and open circuits
- Power limited
- Default setting: Power-Limited. Each power-limited
- DET 1 and DET 2 used for suppression
ARC requires the use of an in-line releasing device,
- DET3/WF configurable for detection or waterflow
P/N 06-220023-001. Two 06-220023-001 devices
- Option to use SUP 1 circuit as DET 4 circuit. * are included.
* Only contact-closure type, non-powered devices - Common NAC/ARC output disable switch
such as switches, pull stations and alarm contacts • Four (4) Relays
of 4-wire detectors to be used on this Detector 4
- 3 independently programmable, normally de-
circuit (TB6 connector on PCB). Powered 2-wire
energized Form-C Relays
automatic detectors must not be connected to this
- 1 dedicated normally energized Form-C Trouble
circuit and the circuit must not be used to power 4-
Relay
wire detectors.
- Relay contacts rated 3 Amps at 30 VDC (resistive)
• One (1) Manual Release Circuit
- Compatible with normally open contact-closure type
devices
- Configurable as Class A or Class B
- Supervised for ground faults and open circuits
- Power limited
• One (1) Abort Circuit
- Compatible with normally open contact-closure type
devices
- Configurable as Class A or Class B
- Supervised for ground faults and open circuits
- Six (6) Abort Modes available
- Power-limited
• Two (2) Supervisory Circuits
- Compatible with normally open contact-closure type
devices
- Configurable as Class A or Class B
- Option to use SUP 1 circuit as fourth detection
circuit *
- Supervised for ground faults and open circuits
- Power-limited

-5-
TECHNICAL SPECIFICATIONS (CONT’D) ORDERING INFORMATION
• NEMA 1 Enclosure
Description Part Number
- 18 gauge sheet steel with door
- Red color Control Units:
- Suitable for semi flush and surface wall mounting
- Indoor/Dry Use Only Kidde AEGIS-XLT Control Unit, NEMA 1 84-70101793
- Optional Trim Ring
- Optional Dead Front Plate Kidde AEGIS-XLT Control Unit, NEMA 4 84-10101510
- Dimensions: Kidde AEGIS-XLT Control Unit, NEMA 12 84-10101508
14-1/4 in. W x 5 in. D x 19 in. H
(362 mm x 127 mm x 483 mm) MICRO 1-EV to AEGIS-XLT Retrofit Kit 84-20100248
- Operating temperature range: 32°F to 120°F
(0°C to 49°C) Accessories and Spare Parts:
- Humidity: 93 ± 2% RH at 90 ± 3°F (32 ± 2°C)
non-condensing Kidde AEGIS-XLT NEMA 1 Enclosure 84-70101537
Only
• NEMA 4 Enclosure
Trim Ring (Red) for NEMA 1 Enclosure 76-600000-007
- 16 gauge sheet steel with door
Bezel Assembly for NEMA 1 Enclosure 06-220151-001
- Red color
- Suitable for wall mounting Replacement PCB Assembly 84-70101664
- Indoor/Outdoor Use
- Dimensions: Replacement Power Supply 06-118394-002
20 in. W x 6 in. D x 24 in. H In-Line Releasing Device 06-220023-001
(508 mm x 152 mm x 609 mm)
- Operating temperature range: -20°F to 120°F Installation/Configuration Kit 84-70000296
(-29°C to 49°C)
Replacement Hardware Installation Kit 06-220149-001
NOTE: Heater Needed For Use Below 32°F (0°C)
- Humidity: 93 ± 2% RH at 90 ± 3°F (32 ± 2°C) Large Capacity Battery Enclosure 76-100010-001
non-condensing
Spare Key (for NEMA 1 Control Unit and 06-118013-001
pull stations)
• NEMA 12 Enclosure
NEMA 1 Control Unit Spare Lock w/2 06-239924-001
- 16 gauge sheet steel with door Keys
- Red color
- Suitable for wall mounting Dead Front Plate for NEMA 1 Enclosure 06-220175-001
- Industrial Use
EOL Resistors (10 pk) 06-220184-001
- Dust-tight and Oil Resistant
- Dimensions: Corrosion Inhibitor 70120188
20 in. W x 6 in. D x 24 in. H
(508 mm x 152 mm x 609 mm) Key Maintenance Bypass Switch 76-600000-200
- Operating temperature range: -20°F to 120°F
(-29°C to 49°C) • Packaging/Shipping
NOTE: Heater Needed For Use Below 32°F (0°C)
- Enclosure, PCB, and PSU packaged in individual
- Humidity: 93 ± 2% RH at 90 ± 3°F (32 ± 2°C)
cartons. Field assembly is required.
non-condensing
- Accessories shipped include mounting hardware, battery
leads, operating instruction sheet, and EOL resistor kit.
- Order in-line releasing device (required for power-limited
ARCs), agent release key maintenance bypass switch
EXPORT INFORMATION (USA):
Jurisdiction: EAR and batteries separately.
US ECCN: EAR99
This document contains technical data subject to the EAR. For detailed installation, operation, and configuration information, refer to the
Kidde AEGIS-XLT Conventional Fire Alarm-Suppression Control Unit Installation,
Kidde, Fenwal and Chemetron are registered trademarks of Kidde-Fenwal Inc., or Operation, and Maintenance Manual
its parents, subsidiaries or affiliates. P/N 06-237464-001.

This literature is provided for informational purposes only. KIDDE-FENWAL, INC. believes this data to be accurate, but it is
published and presented without any guarantee or warranty whatsoever. KIDDE-FENWAL, INC. assumes no responsibility for
the product's suitability for a particular application. The fire suppression system design, installation, maintenance, service and
troubleshooting must be performed by trained, authorized Kidde Fire Systems distributors for the product to work correctly.
If you need more information on this product, or if you have a particular problem or question, contact: 400 Main Street
KIDDE-FENWAL, INC., Ashland, MA 01721 USA, Telephone: (508) 881-2000. Ashland, MA 01721 USA
Tel: 508.881.2000
K-84-300 Rev AD © 2020 Kidde-Fenwal Inc. www.kiddefiresystems.com