The document is a user manual for the PROFINET/DeviceNet Master - Converter. It allows communication between a PROFINET network and a DeviceNet network with up to 512 bytes of reading and writing data in each direction. The converter provides electrical isolation between the networks and power supply. It can be configured using the Compositor SW67608 software to define the communication parameters for each network.

Uploaded by

LiomarJunior
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
56 views24 pages

PROFINET/DeviceNet Master User Manual

The document is a user manual for the PROFINET/DeviceNet Master - Converter. It allows communication between a PROFINET network and a DeviceNet network with up to 512 bytes of reading and writing data in each direction. The converter provides electrical isolation between the networks and power supply. It can be configured using the Compositor SW67608 software to define the communication parameters for each network.

Uploaded by

LiomarJunior
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 24

User Manual PROFINET / DeviceNet Master

Document code: MN67608_ENG Revision 1.000 Pagina 1 di 24


Industrial Electronic Devices

User Manual
Revision 1.000
English

PROFINET / DeviceNet Master -


Converter
(Order Code: HD67608-A1)

for Website information:


www.adfweb.com?Product=HD67608

for Price information:


www.adfweb.com?Price=HD67608-A1

Benefits and Main Features:


For others PROFINET products see also the following link:
Very easy to configure
Other Converter PROFINET to
Electrical isolation Products www.adfweb.com?Product=HD67606 (CAN)
www.adfweb.com?Product=HD67609 (DeviceNet Slave)
Two PROFINET ports www.adfweb.com?Product=HD67610 (J1939)
www.adfweb.com?Product=HD67600 (NMEA2000)
Temperature range: -40°C/85°C (-40°F/185°F) www.adfweb.com?Product=HD67601 (Serial RS232)
www.adfweb.com?Product=HD67601 (Serial RS485)
www.adfweb.com?Product=HD67602 (Modbus Master RS232)
www.adfweb.com?Product=HD67602 (Modbus Master RS485)
www.adfweb.com?Product=HD67603 (Modbus Slave RS232)
www.adfweb.com?Product=HD67603 (Modbus Slave RS485)
www.adfweb.com?Product=HD67604 (PROFIBUS Master)
www.adfweb.com?Product=HD67605 (PROFIBUS Slave)

Do you have an your customer protocol?


www.adfweb.com?Product=HD67003
Do you need to choose a device? do you want help?
www.adfweb.com?Cmd=helpme

ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31


User Manual PROFINET / DeviceNet Master
Document code: MN67608_ENG Revision 1.000 Pagina 2 di 24
Industrial Electronic Devices

INDEX: UPDATED DOCUMENTATION:

Page Dear customer, we thank you for your attention and we remind you that
INDEX 2 you need to check that the following document is:
UPDATED DOCUMENTATION 2 Updated
REVISION LIST 2 Related to the product you own
WARNING 2
TRADEMARKS 2 To obtain the most recently updated document, note the “document code”
SECURITY ALERT 3 that appears at the top right-hand corner of each page of this document.
EXAMPLE OF CONNECTION 4
CONNECTION SCHEME 5 With this “Document Code” go to web page www.adfweb.com/download/
CHARACTERISTICS 6 and search for the corresponding code on the page. Click on the proper
CONFIGURATION 6 “Document Code” and download the updates.
POWER SUPPLY 7
FUNCTION MODES 8 To obtain the updated documentation for the product that you own, note
LEDS 9 the “Document Code” (Abbreviated written "Doc. Code" on the label on the
PROFINET 10 product) and download the updated from our web site
CAN 11 www.adfweb.com/download/
USE OF COMPOSITOR SW67608 12
NEW PROJECT / OPEN PROJECT 12
SET COMMUNICATION 13 REVISION LIST:
DEVICENET NETWORK 14
DEFINE BYTE 15 Revision Date Author Chapter Description
UPDATE DEVICE 16 1.000 26/09/2012 Dp All First Release
MECHANICAL DIMENSIONS 18
ORDERING INFORMATIONS 19
ACCESSORIES 19
PLC CONFIGURATION 20
DISCLAIMER 23
OTHER REGULATIONS AND STANDARDS 23 WARNING:
WARRANTIES AND TECHNICAL SUPPORT 24
RETURN POLICY 24 ADFweb.com reserves the right to change information in this manual about
PRODUCTS AND RELATED DOCUMENTS 24 our product without warning.
ADFweb.com is not responsible for any error this manual may contain.

TRADEMARKS:

All trademarks mentioned in this document belong to their respective


owners.

ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31


User Manual PROFINET / DeviceNet Master
Document code: MN67608_ENG Revision 1.000 Pagina 3 di 24
Industrial Electronic Devices

SECURITY ALERT:

GENERAL INFORMATION
To ensure safe operation, the device must be operated according to the instructions in the manual. When using the device are required for
each individual application, legal and safety regulation. The same applies also when using accessories.

INTENDED USE
Machines and systems must be designed so the faulty conditions do not lead to a dangerous situation for the operator (i.e. independent limit
switches, mechanical interlocks, etc.).

QUALIFIED PERSONNEL
The device can be used only by qualified personnel, strictly in accordance with the specifications.
Qualified personnel are persons who are familiar with the installation, assembly, commissioning and operation of this equipment and who
have appropriate qualifications for their job.

RESIDUAL RISKS
The device is state of the art and is safe. The instrument can represent a potential hazard if they are inappropriately installed and operated
by personnel untrained. These instructions refer to residual risks with the following symbol:

This symbol indicates that non-observance of the safety instructions is danger for people to serious injury or death and / or the
possibility of damage.

CE CONFORMITY
The declaration is made by us. You can send an email to [email protected] or give us a call if you need it.

ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31


User Manual PROFINET / DeviceNet Master
Document code: MN67608_ENG Revision 1.000 Pagina 4 di 24
Industrial Electronic Devices

EXAMPLE OF CONNECTION:

ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31


User Manual PROFINET / DeviceNet Master
Document code: MN67608_ENG Revision 1.000 Pagina 5 di 24
Industrial Electronic Devices

CONNECTION SCHEME:

Figure 1: Connection scheme for HD67608-A1


ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31
User Manual PROFINET / DeviceNet Master
Document code: MN67608_ENG Revision 1.000 Pagina 6 di 24
Industrial Electronic Devices

CHARACTERISTICS:

The HD67608-A1 is a PROFINET / DeviceNet Master - Converter.

It allows the following characteristics:


Up to 512 bytes in reading and 512 bytes in writing;
Triple isolation between DeviceNet - Power Supply, DeviceNet - Ethernet, Power Supply - Ethernet.
Two-directional information between DeviceNet bus and PROFINET bus;
Mountable on 35mm Rail DIN;
Wide power supply input range: 8…24V AC or 12…35V DC;
Wide temperature range: -40°C / 85°C [-40°F / +185°F].

CONFIGURATION:

You need Compositor SW67608 software on your PC in order to perform the following:
Define the parameter of PROFINET line;
Define the parameter of DeviceNet line;
Determinate which PROFINET byte transfer in DeviceNet and vice versa;
Update the device.

ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31


User Manual PROFINET / DeviceNet Master
Document code: MN67608_ENG Revision 1.000 Pagina 7 di 24
Industrial Electronic Devices

POWER SUPPLY:

The devices can be powered at 8…24V AC and 12…35V DC. For more details see the two tables below.

VAC VDC
Vmin Vmax Vmin Vmax
8V 24V 12V 35V

Consumption at 24V DC:

Device Consumption [W/VA]


HD67608-A1 3.5

Caution: Not reverse the polarity power

HD67608-A1

ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31


User Manual PROFINET / DeviceNet Master
Document code: MN67608_ENG Revision 1.000 Pagina 8 di 24
Industrial Electronic Devices

FUNCTION MODES:

The device has got two functions mode depending of the position of the ‘Dip2 of Dip-Switch B’:
The first, with ‘Dip2 of Dip-Switch B’ at “OFF” position, is used for the normal working of the device.
The second, with ‘Dip2 of Dip-Switch B’ at “ON” position, is used for upload the Project and/or Firmware.

For the operations to follow for the updating, see ‘UPDATE DEVICE’ section.

According to the functioning mode, the LEDs will have specifics functions, see ‘LEDS’ section.

Warning:
Dip1 of ‘Dip-Switch B’ must be at ON position for working even if the Ethernet cable isn’t inserted.

ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31


User Manual PROFINET / DeviceNet Master
Document code: MN67608_ENG Revision 1.000 Pagina 9 di 24
Industrial Electronic Devices

LEDS:

The device has got six LEDs that are used to give information of the functioning status.
The various meanings of the LEDs are described in the table below.

LED Normal Mode Boot Mode


1: ON [supply voltage ] ON: Device powered ON: Device powered
(green) OFF: Device not powered OFF: Device not powered
ON: Device not able to communicate with at least one
2: MT [maintenance display] Blinks quickly: Boot state
DeviceNet Slave
(yellow) Blinks very slowly (~0.5Hz): update in progress
OFF: No maintenance are present
ON: The Ethernet connection is defective; the IP
address exists several times in the network; the own
NameOfStation exists several times in the network; no
IP address has been set Blinks quickly: Boot state
3: BF [bus fault] (red)
Flashing: At least one configured AR is no longer in Blinks very slowly (~0.5Hz): update in progress
the data exchange
OFF: No errors are present
ON: At least one AR is not in the data exchange Blinks quickly: Boot state
4: SF [group error] (red)
OFF: No errors are present Blinks very slowly (~0.5Hz): update in progress
Blinks quickly: Boot state
5: Ethernet1 Tx (green) Blinks when is transmitting Ethernet frames
Blinks very slowly (~0.5Hz): update in progress
Blinks quickly: Boot state
6: Ethernet2 Tx (green) Blinks when is transmitting Ethernet frames
Blinks very slowly (~0.5Hz): update in progress

ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31


User Manual PROFINET / DeviceNet Master
Document code: MN67608_ENG Revision 1.000 Pagina 10 di 24
Industrial Electronic Devices

PROFINET:

The PROFINET connection must be made using Connector3 and/or Connector4 of HD67608-A1 with at least a Category 5E cable. The
maximum length of the cable should not exceed 100m. The cable has to conform to the T568 norms relative to connections in cat.5 up to
100 Mbps. To connect the device to an Hub/Switch is recommended the use of a straight cable, to connect the device to a PC/PLC/other is
recommended the use of a cross cable.

ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31


User Manual PROFINET / DeviceNet Master
Document code: MN67608_ENG Revision 1.000 Pagina 11 di 24
Industrial Electronic Devices

DeviceNet:

For terminate the DeviceNet line with a 120Ω resistor it is necessary that the Dip1 of ‘Dip-Switch A’ is at ON position.

Cable characteristics:

DC parameter: Impedance 70 Ohm/m


AC parameters: Impedance 120 Ohm/m
Delay 5 ns/m
Length Baud Rate [bps] Length MAX [m]
125 K 500
250 K 250
500 K 100

ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31


User Manual PROFINET / DeviceNet Master
Document code: MN67608_ENG Revision 1.000 Pagina 12 di 24
Industrial Electronic Devices

USE OF COMPOSITOR SW67608:

To configure the Converter, use the available software that runs with
Windows, called SW67608. It is downloadable on the site www.adfweb.com
and its operation is described in this document. (This manual is referenced
to the last version of the software present on our web site). The software
works with MSWindows (MS 2000, XP, Vista, Seven, 8; 32/64bit).

When launching the SW67608 the right window appears (Fig. 2).

Figure 2: Main window for SW67608

NEW PROJECT / OPEN PROJECT:

The “New Project” button creates the folder which contains the entire device configuration.

A device configuration can also be imported or exported:


To clone the configurations of a programmable “PROFINET / DeviceNet Master – Converter”
in order to configure another device in the same manner, it is necessary to maintain the
folder and all its contents;
To clone a project in order to obtain a different version of the project, it is sufficient to
duplicate the project folder with another name and open the new folder with the button
“Open Project”.

ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31


User Manual PROFINET / DeviceNet Master
Document code: MN67608_ENG Revision 1.000 Pagina 13 di 24
Industrial Electronic Devices

SET COMMUNICATION:

This section define the fundamental communication parameters of two buses, PROFINET and
DeviceNet Master.

By Pressing the “Set Communication” button from the main window for SW67608 (Fig. 2) the
window “Set Communication” appears (Fig. 3).
The window is divided in two sections, one for the PROFINET and the other for the DeviceNet
Master.

The means of the fields for “PROFINET” are:


In the fields “IP ADDRESS” insert the IP address that you want to give to the Converter;
In the fields “SUBNET Mask” insert the SubNet Mask;
In the fields “GATEWAY” insert the default gateway that you want to use. This feature can
be enabled or disabled pressing the Check Box field. This feature is used for going out of
the net;
In the field “Port” the port used for PROFINET communication is defined. The port has a
fixed value of 34964;
In the field "PROFINET Name of Station" is possible to assign a name to the PROFINET
node.

The means of the fields for the “DeviceNet Master” section are:
In the field “ID Device” the address for the DeviceNet Master is defined;
In the field “Baudrate” the velocity of the DeviceNet Master bus is defined.

Figure 3: “Set Communication” window

ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31


User Manual PROFINET / DeviceNet Master
Document code: MN67608_ENG Revision 1.000 Pagina 14 di 24
Industrial Electronic Devices

DEVICENET NETWORK:

By pressing the “DeviceNet Network” button from the main window for SW67608 (Fig. 2) the window “DeviceNet Network” appears (Fig.
4).

The data of the columns have the following meanings:


In the field “ID” the ID of a slave DeviceNet device is defined;
In the field “N BYTE IN” the number of input byte of the slave DeviceNet is defined;
In the field “N BYTE OUT” the number of output byte of the slave DeviceNet is defined;
In the field “Mnemonic” is possible to insert a description. It isn’t necessary compiling this field, is only a label.

Figure 4: “DeviceNet Network” window

ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31


User Manual PROFINET / DeviceNet Master
Document code: MN67608_ENG Revision 1.000 Pagina 15 di 24
Industrial Electronic Devices

DEFINE BYTE:

By pressing the “Define Byte” button from the main window for SW67608 (Fig. 2) the window “Define Offset” appears (Fig. 5).

In the field “Select the Slave DeviceNet” it is possible to select the slave to configure between those defined in the “DeviceNet Network”
step.

The data of the column have the following meanings:

Byte IN side:
In the column “Offset” it is possible to select
the desired byte of DeviceNet which will be
written from the PROFINET Master;
In the column “Mnemonic” is possible to
insert a description. It isn’t necessary
compiling this field, is only a label.

Byte OUT side:


In the column “Offset” it is possible to select
the desired byte of DeviceNet which will be
read from the PROFINET Master;
In the column “Mnemonic” is possible to
insert a description. It isn’t necessary
compiling this field, is only a label.

Figure 5: “Define Offset” window

ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31


User Manual PROFINET / DeviceNet Master
Document code: MN67608_ENG Revision 1.000 Pagina 16 di 24
Industrial Electronic Devices

UPDATE DEVICE:

By pressing the “Update Device” button it is possible to load the created Configuration into the
device; and also the Firmware, if is necessary.

If you don’t know the actual IP address of the device you have to use this procedure:
Turn off the Device;
Put Dip2 of ‘Dip-Switch B’ at ON position;
Turn on the device
Connect the Ethernet cable;
Insert the IP “192.168.2.205”;
Press the “Ping” button, must appear “Device Found!”;
Press the “Next” button;
Select which operations you want to do;
Press the “Execute update firmware” button to start the upload;
When all the operations are “OK” turn off the Device;
Put Dip2 of ‘Dip-Switch B’ at OFF position;
Turn on the device.

At this point the configuration/firmware on the device is correctly updated.

Figure 8: “Update device” windows

ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31


User Manual PROFINET / DeviceNet Master
Document code: MN67608_ENG Revision 1.000 Pagina 17 di 24
Industrial Electronic Devices

If you know the actual IP address of the device you have to use this procedure:
Turn on the Device with the Ethernet cable inserted;
Insert the actual IP of the Converter;
Press the “Ping” button, must appear “Device Found!”;
Press the “Next” button;
Select which operations you want to do;
Press the “Execute update firmware” button to start the upload;
When all the operations are “OK” the device automatically goes at
Normal Mode.

At this point the configuration/firmware on the device is correctly update.

Note:
When you install a new version of the software it is better if the first time you do the update of the Firmware in the HD67608-A1
device.

Note:
When you receive the device, for the first time, you have to update also the Firmware in the HD67608-A1 device.

Warning:
If the Fig. 9 appears when you try to do the Update before require assistance try
these points:
Try to repeat the operations for the updating;
Try with another PC;
Try to restart the PC;
If you are using the program inside a Virtual Machine, try to use in the main
Operating System;
If you are using Windows Seven or Vista or 8, make sure that you have the
administrator privileges;
Figure 9: “Protection” window
Take attention at Firewall lock;
Check the LAN settings.

In the case of HD67608-A1 you have to use the software “SW67608”: www.adfweb.com\download\filefold\SW67608.zip.

ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31


User Manual PROFINET / DeviceNet Master
Document code: MN67608_ENG Revision 1.000 Pagina 18 di 24
Industrial Electronic Devices

MECHANICAL DIMENSIONS:

Figure 10: Mechanical dimensions scheme for HD67608-A1

ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31


User Manual PROFINET / DeviceNet Master
Document code: MN67608_ENG Revision 1.000 Pagina 19 di 24
Industrial Electronic Devices

ORDERING INFORMATIONS:

The ordering part number is formed by a valid combination of the following:


HD67608 – A 1

Connectors Type
1: Removable 5mm Screw Terminal

Enclosure Type
A: 1M, 35mm DIN Rail mounting

Device Family
HD67608: PROFINET / DeviceNet Master - Converter

Order Code: HD67608-A1 - PROFINET / DeviceNet Master - Converter

ACCESSORIES:

Order Code: AC34001 - 35mm Rail DIN - Power Supply 220/240V AC 50/60Hz – 12 V AC
Order Code: AC34002 - 35mm Rail DIN - Power Supply 110V AC 50/60Hz – 12 V AC

ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31


User Manual PROFINET / DeviceNet Master
Document code: MN67608_ENG Revision 1.000 Pagina 20 di 24
Industrial Electronic Devices

PLC CONFIGURATION:

The configuration and commissioning of the PROFINET Converter as described on the following pages was accomplished with the help of the
TIA Portal V11-software of Siemens. In case of using a control system from another supplier please attend to the associated documentation.
These are the steps to follow:

1) Install the description file of the module.

ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31


User Manual PROFINET / DeviceNet Master
Document code: MN67608_ENG Revision 1.000 Pagina 21 di 24
Industrial Electronic Devices

2) Import the module in the network; connect the device to the PLC network and edit the parameters of IP, station name etc.

ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31


User Manual PROFINET / DeviceNet Master
Document code: MN67608_ENG Revision 1.000 Pagina 22 di 24
Industrial Electronic Devices

3) Load the configuration into the PLC.

ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31


User Manual PROFINET / DeviceNet Master
Document code: MN67608_ENG Revision 1.000 Pagina 23 di 24
Industrial Electronic Devices

DISCLAIMER

All technical content within this document can be modified without notice. The content of the document content is a recurring audit.
For losses due to fire, earthquake, third party access or other accidents, or intentional or accidental abuse, misuse, or use under abnormal
conditions repairs are charged to the user. ADFweb.com S.r.l. will not be liable for accidental loss of use or inability to use this product, such
as loss of business income. ADFweb.com S.r.l. shall not be liable for consequences of improper use.

OTHER REGULATIONS AND STANDARDS

WEEE INFORMATION
Disposal of old electrical and electronic equipment (as in the European Union and other European countries with separate
collection systems).
This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish. Instead, it
should be taken to an applicable collection point for the recycling of electrical and electronic equipment. If the product is disposed
correctly, you will help prevent potential negative environmental factors and human health, which could otherwise be caused by
inappropriate disposal. The recycling of materials will help to conserve natural resources. For more information about recycling this
product, please contact your local city office, your household waste disposal service or the shop where you purchased the product.

RESTRICTION OF HAZARDOUS SUBSTANCES DIRECTIVE


The device respects the 2002/95/EC Directive on the restriction of the use of certain hazardous substances in electrical
and electronic equipment (commonly referred to as Restriction of Hazardous Substances Directive or RoHS).

CE MARKING
The product conforms with the essential requirements of the applicable EC directives.

ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31


User Manual PROFINET / DeviceNet Master
Document code: MN67608_ENG Revision 1.000 Pagina 24 di 24
Industrial Electronic Devices

WARRANTIES AND TECHNICAL SUPPORT:

For fast and easy technical support for your ADFweb.com SRL products, consult our internet support at www.adfweb.com.
Otherwise contact us at the address [email protected]

RETURN POLICY:

If while using your product you have any problem and you wish to exchange or repair it, please do the following:
1) Obtain a Product Return Number (PRN) from our internet support at www.adfweb.com. Together with the request, you need to
provide detailed information about the problem.
2) Send the product to the address provided with the PRN, having prepaid the shipping costs (shipment costs billed to us will not be
accepted).
If the product is within the warranty of twelve months, it will be repaired or exchanged and returned within three weeks. If the product is no
longer under warranty, you will receive a repair estimate.

PRODUCTS AND RELATED DOCUMENTS:

Part Description URL


HD67120 Converter Ethernet to RS232/RS485 www.adfweb.com?product=HD67120
HD67119 Converter USB 2.0 to RS485 Isolated www.adfweb.com?product=HD67119
HD67507 Gateway Modbus TCP Server to RTU Master www.adfweb.com?product=HD67507
HD67510 Gateway Modbus TCP Client to RTU Slave www.adfweb.com?product=HD67510

ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31

You might also like