NOTIFIER ONYX Series Panel – NFS-320E
• 1 Loop Fire Alarm Control Panel
- 318 FlashScan® devices per loop
- 159 Add. Detectors and 159 Add. Modules
• 80 Character LCD Display with Full QWERTY
keypad for programming
• Networkable with NOTI●FIRE●NET (Normal and High-Speed) up to 200
nodes or over the internet to communicate with Fire Alarm Central
Monitoring Center (TCP/IP)
• Communicate with iBMS through ModBus or BACNet communication
(TCP/IP)
• RS-485 for Annunciators and RS-232 for printer interface
• Latest UL 9th Edition approved and FM
© 2015 by Honeywell International Inc. All rights reserved.
© 2015 by Honeywell International Inc. All rights reserved.
4
NOTIFIER ONYX Series Panel – NFS2-640E
• 2 Loops Control Fire Alarm Control Panel
- 318 FlashScan® devices per loop
- 636 FlashScan® devices fully loaded
• 80 Character LCD Display with Full QWERTY
keypad for programming
• Support Fire Fighter Intercom and Digital Voice Command
• Networkable with NOTI●FIRE●NET (Normal and High-Speed) up to 200
nodes or over the internet to communicate with Fire Alarm Central
Monitoring Center (TCP/IP)
• Communicate with iBMS through ModBus or BACNet communication
(TCP/IP)
• RS-485 for Annunciators and RS-232 for printer interface
• Latest UL 9th Edition approved and FM
© 2015 by Honeywell International Inc. All rights reserved.
© 2015 by Honeywell International Inc. All rights reserved.
5
NOTIFIER ONYX Series Panel – NFS2-3030E
• Up to 10 Loops (Signaling Line Circuits)
- 318 FlashScan® devices per loop
- 3,180 FlashScan® devices fully loaded
• 640 Character LCD Display w/Full QWERTY keypad for programming
• 10 Suppression Circuits (for Fire Suppression System)
• Support Fire Fighter Intercom and Digital Voice Command
• Networkable with NOTI●FIRE●NET (Normal and High-Speed) up to
200 nodes or over the internet to communicate with Fire Alarm
Central Monitoring Center (TCP/IP)
• Communicate with iBMS through ModBus or BACNet communication
(TCP/IP)
• RS-485 for Annunciators and RS-232 for printer interface
• Latest UL 9th Edition approved and FM
© 2015 by Honeywell International Inc. All rights reserved.
© 2015 by Honeywell International Inc. All rights reserved.
6
NOTIFIER Addressable Detectors
UL 268, 7th Edition – Smoke Detectors
© 2015 by Honeywell International Inc. All rights reserved.
© 2015 by Honeywell International Inc. All rights reserved.
UL 268 7th Edition | Background
• Goal to reduce nuisance alarms
- People disconnect to avoid false alarms
• Change in household materials and design
- Synthetic materials, open layouts & lighter construction materials burn hotter &
faster
- Escape time reduced - average of 17 min to 3-4 min
• National Fire Protection Research Foundation (NFPRF) and Smoke
Characterization Project
- Smoldering test and a flaming test - represent the smoke profiles of actual fires
- Capable of distinguishing between a smoldering fire and cooking smoke
- Based on differences in smoke particle
▪ size,
▪ quantity,
▪ gas concentrations and
▪ color between fires and cooking aerosols
© 2015 by Honeywell International Inc. All rights reserved.
8
NOTIFIER Addressable Detectors
• Addressable Photoelectric Smoke Detectors
- Stable communication technique with noise immunity
- Two-wire SLC connection with FlashScan® Technology
- Adjustable Sensitivity (0.5% to 2.35% per foot obscuration)
- 360° FOV Bi-LED Indicator for Normal and Alarm status
- Built-in rotary switches for addressing
• Addressable Heat Detectors
- State-of-the-art thermistor technology for fast response
- Two-wire SLC connection with FlashScan® Technology
- 360° FOV Bi-LED Indicator for Normal and Alarm status
- Rate-of-rise will sense increasing 8.3°C/minute with Fixed Heat
sensor temperature at 57°C
- Fixed Heat preset temperature at 57°C
- Fixed High-temperature preset temperature at 88 °C
© 2015 by Honeywell International Inc. All rights reserved.
© 2015 by Honeywell International Inc. All rights reserved.
9
NOTIFIER Addressable Input Module
• Zone Module (FZM-1)
- Interface for monitors and supervises 2-wire detector
- Need external 24Volt resettable power
- Class A or Class B Circuit
- LED Indicator for Normal and Alarm status
- Built-in rotary switches for addressing
• Mini Monitor Module (FMM-101)
- Interface for monitors water-flow devices, or other normally open
dry contact alarm activation
- No additional power required
- Class B Circuit only
- Tinned, stripped leads for ease of wiring
- Built-in rotary switches for addressing
© 2015 by Honeywell International Inc. All rights reserved.
© 2015 by Honeywell International Inc. All rights reserved.
10
NOTIFIER Addressable Output Module
• Control Module (FCM-1)
- Interface to switch 24 VDC audible/visual power
- Need external 24Volt power supply
- Maximum contact rating 2A
- Class A or Class B Circuit
- LED Indicator for Normal and Alarm status
- Built-in rotary switches for addressing
• Relay Module (FRM-1)
- Module may be programmed to operate dry contacts for
applications such as Air Handling Unit shutdown, Pressurize
Fan, Homing Lift or PAVA
- Built-in rotary switches for addressing
© 2015 by Honeywell International Inc. All rights reserved.
© 2015 by Honeywell International Inc. All rights reserved.
11
FIRE ALARM SEMI ADDRESSABLE SYSTEM
© 2015 by Honeywell International Inc. All rights reserved.
© 2015 by Honeywell International Inc. All rights reserved.
Home
12
SYSTEM SENSOR Linear Heat Detector
• DigitalLinear Heat Detector (800 Series)
- Multiple alarm temperature ratings available (Factory Preset)
- Maximum zone length (800 Series) - 1000 meters
- Easy replacing Linear Heat Detector
- Compatible with any conventional or intelligent fire alarm panel
- Smoothing algorithms provide false alarm immunity
© 2015 by Honeywell International Inc. All rights reserved.
© 2015 by Honeywell International Inc. All rights reserved.
13
SYSTEM SENSOR Linear Heat Detector
• Analog Linear Heat Detector (900 Series)
- Multiple alarm temperature ratings available (Factory Preset)
- Maximum zone length (900 Series) - 200 meters
- Easy replacing Linear Heat Detector
- Compatible with any conventional or intelligent fire alarm panel
- Smoothing algorithms provide false alarm immunity
© 2015 by Honeywell International Inc. All rights reserved.
© 2015 by Honeywell International Inc. All rights reserved.
14
SYSTEM SENSOR Linear Heat Detector
© 2015 by Honeywell International Inc. All rights reserved.
© 2015 by Honeywell International Inc. All rights reserved.
Notifier Repeaters
Network Repeater for
Local Repeater for Noti-Fire-Network
NFS2-3030 Panel
Local Repeater for
NFS-320E & NFS2-
640E Panels
FDU-80 LCD-160 NCA-2
+ ABS-
2D
© 2015 by Honeywell International Inc. All rights reserved.
17
NOTIFIER ONYX Network Annunciator – NCA-2
• Work as Main Control Fire Alarm System
• Compatible with ONYX Series Panel
• Fixed Function Key
- Acknowledge
- Signal Silence
- System Reset
• 640-character LCD Display with Full QWERTY keypad
• Networkable with NOTI●FIRE●NET (Normal and High-Speed) up
to 200 nodes or over the internet to communicate with Fire Alarm
Central Monitoring Center (TCP/IP)
• RS-485 for Annunciators and RS-232 for printer interface
• Approval : UL and FM Approved
© 2015 by Honeywell International Inc. All rights reserved.
© 2015 by Honeywell International Inc. All rights reserved.
18
NOTIFIER Networking System (NOTI●FIRE●NET)
• Supports all NOTIFIER intelligent systems NFS2-3030
- NFS-320 Node 35
- NFS/NFS2-640
NFS2-640
- NFS/NFS2-3030
Node 30 NFS2-640
- NCA/NCA2
- AM-2020/AFP-1010 Node 50
- AFP-400/300
- AFP-200
• Backward and forward compatible
• Wire and Fiber Connection
• High-Speed Communication
ONYXWorks
• Up to 200 Nodes in 1 (One) System
Node 25
NFS2-3030
Node 10
© 2015 by Honeywell International Inc. All rights reserved.
© 2015 by Honeywell International Inc. All rights reserved.
19
NOTIFIER Central Monitoring System - ONYXWorks
© 2015 by Honeywell International Inc. All rights reserved.
© 2015 by Honeywell International Inc. All rights reserved.
HONEYWELL
CONNECTED LIFE
SAFETY SERVICES
21
CLSS Architecture
Control
CLSS
GATEWAY
Events
Facility Manager
Check Point
CLSS Check
Fire Panels Point
Local over Mobile Bluetooth for CLSS Site Manager
commissioning and proof of presence
© 2015 by Honeywell International Inc. All rights reserved.
OSID
FIRE ALARM Open-area Smoke Imaging
SYSTEM Detection
23
Open-area Smoke Imaging Detection
▪ Dual frequency beams
▪ Digital imaging versus photodiodes
▪ Ball & Socket arrangement
▪ Smart algorithms
▪ Diagnostic tools
© 2015 by Honeywell International Inc. All rights reserved.
24
OSID – Principle of Operation
▪ An active Emitter with wide beam LEDs
transmit 2 different wavelengths IR and
UV to the Imager
▪ Intelligent software locates the specific
pixels on the multi pixel CMOS Imager
illuminated by the uniquely coded
Emitter
▪ Relative strengths of the 2 wavelength
signals are compared to detect smoke
and discriminate against nuisance
alarm particulates
▪ Building movement and alignment is
managed by Imager software without
any need for controlled motor drives
© 2015 by Honeywell International Inc. All rights reserved.
25
Imager versus Photo Diode
▪ OSID ‘sees’ the protected
area.
▪ One Imager equals
100.000’s of photodiodes
▪ An Imager locates and 1 2
tracks the position of an
Emitter anywhere in its field
of view at pixel level
▪ OSID can operate reliably
in all lighting conditions;
bright day/ sunlight to total
Emitters
darkness
© 2015 by Honeywell International Inc. All rights reserved.
26
What does OSID bring to the table?
▪ Faster detection than single wavelength beams
▪ Simple installation, commissioning and maintenance
▪ Long range detection
▪ High tolerance to vibration and structural
movement
▪ High resistance to dust, fogging, steam,
reflections and object intrusion
▪ High resistance to reflected sunlight
▪ Aesthetically discreet and 3D coverage
▪ Unique, unprecedented diagnostic tools
© 2015 by Honeywell International Inc. All rights reserved.
27
Higher sensitivity - faster detection
▪ UV is prime detection wavelength
▪ 20% obscuration over 490 ft/150 m
UV is 50% more sensitive 33 %
than IR to detect flaming fire
20 %
© 2015 by Honeywell International Inc. All rights reserved.
28
Simple Installation
▪ Simple and easy installation using a unique Laser
Alignment Tool
• No need for precise alignment due to the wide angle
of view of the Imager(s)
• Complex and time consuming alignment tools not
needed. “Laser screwdriver” for quick and easy
alignment
• System can be aligned without powering the units with
or without support bracket
▪ NO control ground station required
▪ Ball & Socket arrangement
• Wide range of vertical and horizontal adjustment
• Fits all walls, no need for adjustment brackets
Up to 70% time saving compared to
traditional beams
© 2015 by Honeywell International Inc. All rights reserved.
29
Simple Installation
© 2015 by Honeywell International Inc. All rights reserved.
30
Simple Installation
OR The only tool you will
ever need
© 2015 by Honeywell International Inc. All rights reserved.
31
Simple Installation
▪ Unique solution with Imagers in
center serving battery powered
Emitters along the perimeter
▪ Power only to the centre units
5,85 “/15 cm
Cost saving approaches
© 2015 by Honeywell International Inc. All rights reserved.
32
Operates over long ranges
▪ Reliably detecting at 656 ft/200 m
▪ Allows for 20% sensitivity setting at
656 ft/150 m
▪ Can operate through metal support
structure of the roof with a minimal
free view between Imager and
Emitters of ø 20 cm/7,8” .
20 cm/7,8”
5,85 “/15 cm
OSID outperforms beams
with 50%
© 2015 by Honeywell International Inc. All rights reserved.
33
High tolerance to structural movement
and vibration
▪ OSID guarantees a minimum of
2° in all directions of building flex
• Best competitive beams gives a
false alarm at 0.6° misalignment
▪ OSID has no risk of missing a
slow burning fire because of the
rate of compensation
• OSID relies on 2 different
wavelengths to recognize smoke
from building movement
Flex tested up to 4°without issues
© 2015 by Honeywell International Inc. All rights reserved.
34
High resistance to reflected sunlight
▪ The Imager resistance is based
on two techniques
• IR and UV filter at the Imager
• Background subtraction
When fully exposed to the sun
OSID will only give a fault
© 2015 by Honeywell International Inc. All rights reserved.
35
Aesthetically discreet and 3D coverage
▪ Up to 7 Emitters may be used
at the same time with a single
Imager
▪ Emitters can be positioned at
multiple elevations
▪ Emitters can be added later
Strictly confidential
© 2015 by Honeywell International Inc. All rights reserved.
36
Unique, unprecedented diagnostic tools
▪ On-board event log in the Imager
▪ Industry first and unique to the beam market
▪ Memory stores 10k events
▪ Stores data identical to the Diagnostic log files with time
and date stamp
▪ Provides a wealth of information surrounding an alarm,
fault or any significant change
▪ Events and data retrieved by OSID Diagnostic SW tool
▪ Data can be analysed and plotted revealing; IR/UV
attenuation, beam positioning, temperature, reference
signals, contamination, loop voltage etc.
Strictly confidential
© 2015 by Honeywell International Inc. All rights reserved.
37
Detector range
▪ OSI-10 Imager - 7º coverage, 24V DC
▪ OSI-90 Imager - 80º coverage, 24V DC
▪ OSE-SP-01 Emitter - Standard Power, Alkaline battery
▪ OSE-SPW Emitter - Standard Power, Wired at 24V DC
▪ OSE-HPW Emitter - High Power, Wired at 24V DC
▪ OSE-HP-01 Emitter - High Power, Alkaline battery
© 2015 by Honeywell International Inc. All rights reserved.
38
Range of Accessories
▪ OSID-WG Wire Guard
▪ OSID-EHI Imager Environmental Housing
▪ OSID-EHE Emitter Environmental Housing
▪ OSI-LS Light shield for OSI-10
▪ RTS151KEY Imager Reset Station Flush Mount
▪ RTS151KIT Imager Reset Station Surface Mount
© 2015 by Honeywell International Inc. All rights reserved.
39
Range of Accessories
▪ OSID-INST OSID Installation Kit. Incl: Laser alignment
tool, test filter, PC cable, cleaning cloth,
manual
▪ VKT-301 OSID Demo kit consisting of 2 X OSE-SPW
(fitted with alkaline batteries), 1 X OSI-90, 1 X
OSID-INST, fitted in a carry case with mounting
plates
▪ OSP-001 FTDI Cable 1.5m
▪ OSP-002 Laser Alignment tool
▪ OSP-003 Acrylic test filter - 10 pack
▪ OSP-003-200 Acrylic test filter - bulk pack 200 units
▪ OSE-RBL Emitter Lithium battery exchange unit
▪ OSE-RBA Emitter spare battery Alkaline
© 2015 by Honeywell International Inc. All rights reserved.
40
Approvals
▪ UL/ULC (US/Canada)
▪ CSFM (US)
▪ CE - EMC and CPD (Europe)
▪ AFNOR (France)
▪ VdS (Germany)
▪ BOSEC (Belgium)
▪ ActivFire (Australia-New Zealand)
▪ CFE (China)
▪ VNIIPO (Russia)
▪ FM (US)
© 2015 by Honeywell International Inc. All rights reserved.
FIRE
SUPPRESSION
SYSTEM
What is Clean Agent Fire Suppression System? 42
Use of inert gases and chemical/synthetic agents to extinguish a fire is called as clean
agent fire suppression system.
Chemical agents HFC-227ea & FK-5-1-12 are waterless agents/gases, which gets discharged into the risk
area within 10 seconds and suppresses the fire immediately ( within 10 Sec).
Diagram shows the integration with Fire Detection System
© 2015 by Honeywell International Inc. All rights reserved.
Why Clean Agent Fire Suppression System is necessary? 43
When the challenge is,
- Class A, C & D type Fires
- Wet Systems like Sprinklers, Deluge systems can’t be
used due to Electrical equipments
- Controlling Oxygen.
Purpose,
Fire Triangle - Portable Dry Powder Extinguishers, CO2 flooding system,
some wet Extinguishers, Inert Gases remove “Oxygen”
from Fire to extinguish.
- Sprinklers, Clean Agents remove “Heat” from the Fire
situation
- Removal of Fuel is usually a challenge in Fire situations,
hence, normally “Oxygen” or “Heat” is removed /
targetted to control / douse the Fire.
Remove any one and Fire gets “extinguished” - Server Rooms, Critical Control Rooms, Substations,
Switch Rooms etc. requires Gas based suppression
system
© 2015 by Honeywell International Inc. All rights reserved.
Types of Fire 44
Not all fires are
the same. Per
NFPA 10,
burning may be
classified into
one or more of
the following
fire classes and
the fire
protection
specialist must
select the right
fire
extinguishing
system for the
hazard.
© 2015 by Honeywell International Inc. All rights reserved.
Clean Agent | Properties & Listing
HFC-227ea & FK-5-1-12 are:- Agent Listing/Approvals
- Clean - Underwriters Laboratories
- Electrically non-conductive - US Environmental Protection Authority (EPA)
- Colorless - NFPA 2001
- Odorless
- Non-toxic
Environmental Properties
Description Halon 1301 HFC-125 FK-5112 HFC-227ea
Ozone Depletion Potential 12.0 0.0 0.0 0.0
Global Warming Potential 7140 3500 1 3220
Atmospheric Lifetime (Years) 65 29 0.014 34.2
© 2015 by Honeywell International Inc. All rights reserved.
Honeywell | Offering
UL Listed 25 BAR system with DOT cylinders
HFC-227ea Clean Agent FK-5-1-12 Clean Agent
System System
LTR LTR
© 2015 by Honeywell International Inc. All rights reserved.
Honeywell | Offering
1st ever UL Listed 42 BAR system with seamless cylinders
HFC-227ea Clean Agent FK-5-1-12 Clean Agent
System System
LTR LTR
© 2015 by Honeywell International Inc. All rights reserved.
Honeywell | Installation Scheme
© 2015 by Honeywell International Inc. All rights reserved.
49
CYLINDER DATA
SEAMLESS CYLINDER
Capacity Valve Size Storage Agent Agent Fill Height Diameter
Pressure Range (Kg)
34 Liter 1.5” 25 & 42 Bar HFC & FK 16.0 to 38.0 1118 mm Ø 232
80 Liter 2” & 1.5” 25 & 42 Bar HFC & FK 39.0 to 90.0 1842 mm Ø 267
120 Liter 2” & 1.5” 25 & 42 Bar HFC & FK 58.0 to 135.0 1642 mm Ø 356
140 Liter 2” & 1.5” 25 & 42 Bar HFC & FK 67.0 to 157.0 1867 mm Ø 356
DOT CYLINDER – to roll out by OCT 2020
Capacity Valve Size Storage Agent Agent Fill Height Diameter
Pressure Range (Kg)
15 Liter 1.5” 25 Bar HFC & FK 7.0 to 16.2 488.3 mm Ø 254
29 Liter 1.5 25 Bar HFC & FK 14.0 to 32.5 790.0 mm Ø 254
49 Liter 1.5” 25 Bar HFC & FK 23.6 to 54.9 83.6 mm Ø 324
80 Liter 2” 25 Bar HFC & FK 38.5 to 89.7 1258 mm Ø 324
104 Liter 2” 25 Bar HFC & FK 50.2 to 117.1 794.6 mm Ø 508
148 Liter 2” 25 Bar HFC & FK 71.3 to 166.5 1023 mm Ø 508
227 Liter 3” 25 Bar HFC & FK 109.0 to 254.6 1478 mm Ø 508
369 Liter 3” 25 Bar HFC & FK 177.2 to 414.0 1643 mm Ø 610
© 2015 by Honeywell International Inc. All rights reserved.
ELECTRICAL
CABINET
SUPPRESSION
SYSTEM
ECS- DLP | System Working
Cylinder with clean agent is connected to one end of the
heat detection tube, the tube is laid inside the cabinet &
enclosure. On detecting a temperature of 110°C or above
heat detection tube de-pressurizes itself to the
atmospheric pressure & ruptures it at the source of
fire/heat.
The clean agent from the cylinder system flows through
the Heat Detection Tube & get released from the ruptured
hole. The fire is quickly suppressed just moments after it
began, hence minimizing damage and downtime
This most innovative technology makes this system fully
automatic. It requires no power & human intervention
specially applicable for “micro-environments”where the fire
hazard likely to be in the enclosed space
© 2015 by Honeywell International Inc. All rights reserved.
ECS- DLP | System Working
© 2015 by Honeywell International Inc. All rights reserved.
ECS- DLP | FEATURES
A COMPLETE PRE-ENGINEERED SYSTEM RELIABILITY
▪ Designed to protect & suppress Electrical Enclosures ▪ UL Listed Clean Agent & Heat Detection Tube
and Circuitry ▪ Dual Valve Outlet- Ensures substantial savings yet
▪ Pre-Engineered Electrical Cabinet Suppression System protecting large sized cabinets
kit
FULLY AUTOMATIC FAST DETECTION
▪ Automatically detects and suppresses fire ▪ Get Installed directly inside electrical cabinets –
▪ No external power or Human intervention required closer to where a fire can start
© 2015 by Honeywell International Inc. All rights reserved.
ECS- ILP | System Working
▪ Cylinder is pressurized at 16.5 Bar with Nitrogen & filled up
with clean agent FK-5-1-12
▪ The heat detection tube is connected on the cylinder valve
(as shown in the picture). The discharge pipe with discharge
nozzles is connected to the discharge outlet port of the
cylinder valve (as shown in the picture)
▪ Heat detection tube is laid inside the electrical cabinet & on
detecting a temperature of 110°C or above, this heat
detection tube de-pressurizes itself to the atmospheric
pressure (1Bar) by releasing the nitrogen from it.
▪ On activation, the clean agent from the cylinder flows through
the discharge pipe & get released through the discharge
nozzles inside the electrical cabinet & suppression the fire
immediately by flooding the entire cabinet.
This system requires no power & human intervention specially
applicable for “micro-environments” where the fire hazard likely
to be in the enclosed space
*An independent ½” black steel/flexible seamless pipe, schedule 40, ASTM A53, Grade B, shall be used for delivery of the FK-5-12
fire suppression
© 2015 Agent
by Honeywell into the
International Electrical
Inc. All panel through discharge nozzles
rights reserved.
Not Just Fire DetectioN & Room Flooding System….
Introducing “Honeywell Multipoint, Clean Agent, UL Listed, In-Direct Low Pressure Electrical Cabinet Fire
Suppression System”……….for individual panel/machine protection- Making Electrical Panels Fire Safe
MANUAL or
MULTI POINT
RELIABILITY ELECTRONIC
SUPPRESSION
ACTUATION
UL Listed System Manually or Nozzle based Multi
(UL Listed Clean Electronically Point Suppression
Agent, UL Listed operatable through System
Heat Detection actuators
Tube, UL Listed
Cylinder &
Accessories)
© 2015 by Honeywell International Inc. All rights reserved.
ECS-ILP | DESIGN
© 2015 by Honeywell International Inc. All rights reserved.
Target segment | applications
Electrical & Flammable
Transformer Electronic Chemical
Cabinets Cabinets Storage
Cabinets
CNC & VMC Laboratory Generator
Machining Exhaust Cabinets Enclosures
Cabinets
© 2015 by Honeywell International Inc. All rights reserved.
Michael Köhler
THANKS
Honeywell Confidential - © 2017 by Honeywell International Inc. All rights reserved.