D’SmartOffice: Smart Energy Management

D'Smart Solutions offers several smart control systems for offices, hotels, and homes under its D'SmartOffice series. The D'SmartOffice series allows users to monitor and control air conditioning systems from smartphones or tablets remotely. This provides higher comfort and convenience while improving efficiency at a low cost. Key features include energy and cost monitoring, time efficiency through convenient control of air conditioners and lights on the same floor via one controller, smart air conditioning control with automatic notifications, smart lighting control, and tenant billing based on individual energy consumption.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
164 views11 pages

D’SmartOffice: Smart Energy Management

D'Smart Solutions offers several smart control systems for offices, hotels, and homes under its D'SmartOffice series. The D'SmartOffice series allows users to monitor and control air conditioning systems from smartphones or tablets remotely. This provides higher comfort and convenience while improving efficiency at a low cost. Key features include energy and cost monitoring, time efficiency through convenient control of air conditioners and lights on the same floor via one controller, smart air conditioning control with automatic notifications, smart lighting control, and tenant billing based on individual energy consumption.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 11

D’Smart Solutions

Office

Hotel

Home

DHOSCPC2005
2 D’SmartOffice D’SmartOffice 3

OVERVIEW

D’SmartOffice series allows


users to monitor and control the
air conditioning system through
smartphone or tablet from
anywhere. This smart control
system provides higher levels of
comfort and convenience for $
occupants while also improving the
efficiency at low investment cost.

Perfect for offices, retail, hospitality,


education institutions and other
businesses.

HIGHLIGHTS F E AT U R E S

Energy & Time Efficiency Energy Consumption Monitoring


Cost Management
Conveniently control air Take control of your electrical cost by
Users can easily keep track of conditioners and lights on the same monitoring usage
their office’s monthly energy floor with one controller, instead
usage through the trend graphs of locating each of the multiple Smart Air-Conditioner
and reports generated. Optimise controllers in an area. Zone Control
and monitor expenditure with allows users to save time and Control and monitor your air-conditioner with
the tenant billing function that conveniently access all facilities on automatic notifications
ensures billing based on each a floor from their fingertips.
tenant’s consumption data. Smart Lighting Control
Achieve optimal lighting with the ability to
Convenience control and monitor your lights
Upgrade any office building using
the Scene Control function, which Zone Control
allows users to schedule and Allows for greater control and customization
automatically activate multiple according to every office building’s needs
facilities at the same time to suit
different situations. Whether a Tenant Billing Function
meeting or presentation, users can
$ Ability to generate invoice for each tenant based
simply set and access a fixed preset
and control their facilities with just on the individual energy consumption tracked
a simple press of a button.
4 D’SmartOffice D’SmartOffice 5

D’SmartOffice F E AT U R E
. A smartphone, tablet or PC can
D’SmartOffice Touch F E AT U R E
. A dedicated touch panel

SVMPC1 SVMPC1T
be used to monitor and control to monitor and control air-
air-conditioning from anywhere conditioning with ease
. Malfunctions are reported . Malfunctions are reported
automatically to the service automatically to the service
contractor for prompt repair. contractor for prompt repair.
For easy installation of an air-conditioning management system for For easy installation of an air-conditioning management system for
small to medium buildings . Only simple installation work small to medium buildings . Only simple installation work
is needed is needed
With only simple wiring, smart air-conditioning through centralised control is possible for the With only simple wiring, smart air-conditioning through centralised control is possible for the
entire building. Daily air-conditioning operations can be automated. entire building. Daily air-conditioning operations can be automated.

Required Equipment Required Equipment


. DTA116A51 . DTA116A51
. SVMPC1 . SVMPC1T
* Wifi router and internet environment are * Wifi router and internet environment are
provided by the customer provided by the customer

Operating Conditions Operating Conditions


. 1 DTA116A51 can connect up . 1 DTA116A51 can connect up
to 64 indoor units to 64 indoor units
* Residential indoor units require BRP72C42 * Residential indoor units require BRP72C42
to connect D’SmartOffice to connect D’SmartOffice

SVMPC1 FUNCTIONS SVMPC1T FUNCTIONS

Category Functions Description Category Functions Description

English, Spanish, Portuguese, Simplified Chinese, Traditional Chinese, Vietnamese, English, Spanish, Portuguese, Simplified Chinese, Traditional Chinese, Vietnamese,
Multi Language Support Multi Language Support
Bahasa (Indonesia), Thai and Japanese Bahasa (Indonesia), Thai and Japanese

Monitoring Screen Icons display with real-time status updates allows easy navigation and control Monitoring Screen Icons display with real-time status updates allows easy navigation and control
Basic Functions Basic Functions
Monitoring Screen (Layout) Icons display according to the layout of building level Monitoring Screen (Layout) Icons display according to the layout of building level

Manual Operation Manually operating is still possible Manual Operation Manually operating is still possible

Schedule Automatic operation depending on date and time can be realized Schedule Automatic operation depending on date and time can be realized

Interlock Automatic operation depending on status change of management point is realized Interlock Automatic operation depending on status change of management point is realized
Automatic Control Automatic Control
Scene Control Single button controls multiple operations Scene Control Single button controls multiple operations

Setback Operation Keeps room at a semi-comfortable temperature with minimum energy Setback Operation Keeps room at a semi-comfortable temperature with minimum energy

Setpoint Range Limitation Prevents setpoint from being set too high/low Setpoint Range Limitation Prevents setpoint from being set too high/low
Energy Saving Energy Saving
Off Timer Automatically turn off air conditioner after certain time Off Timer Automatically turn off air conditioner after certain time

Energy Graph Energy consumption per day / month / year can be displayed in bar chart Energy Graph Energy consumption per day / month / year can be displayed in bar chart

Data Management Trend Graph Analog value like temperature, humidity, etc. can be displayed in line chart Data Management Trend Graph Analog value like temperature, humidity, etc. can be displayed in line chart

Operation History All operation, status change and error infomation are listed with date and time Operation History All operation, status change and error infomation are listed with date and time

Remote Access Smartphone access User can access to SVMPC1 from anywhere by smartphone, tablet and PC Remote Access Smartphone access User can access to SVMPC1T from anywhere by smartphone, tablet and PC

Access Security Only authorised users can access with username and password Access Security Only authorised users can access with username and password

Access Security Device Registration Registered device (tablet, smartphone, PC) can access through the internet Access Security Device Registration Registered device (tablet, smartphone, PC) can access through the internet

Encrypted Data Encrypted Data


All data communication through the internet is encrypted by SSL All data communication through the internet is encrypted by SSL
Communication Communication
6 D’SmartOffice D’SmartOffice 7

D’SmartOffice F E AT U R E
. Various equipment, including
System
Multi-Site Management System Architecture
air-conditioning, can be
operated and monitored
remotely from headquarters.
. Energy can also be monitored
at each facility by connecting a
For remote, centralised control of air-conditioning and other watt meter.
equipment installed at multiple buildings
. Only simple installation work
Centralised control via the Internet is possible for multiple buildings at different locations. is needed
. Malfunctions are reported
automatically to the service
contractor for prompt repair.

Required Equipment
At Individual Site:
. DTA116A51
(Connection of up to 64 indoor units
is possible.)
. SVMPC1
. WAGO I/O system
(This is necessary for equipment
control other than air-conditioning.)

At Headquarters:
. MSMPN1
* WiFi router and Internet environment
are provided by the customer.

Operating Conditions
. One MSMPN1 enables
centralised control of up to
300 buildings at once.

MSMPN1 FUNCTIONS

Category Functions Description

English, Spanish, Portuguese, Simplified Chinese, Traditional Chinese, Vietnamese,


Multi Language Support
Bahasa (Indonesia), Thai and Japanese
Basic Functions
Monitoring Screen All site information is conveniently displayed in one screen

Site Access Access to site SVMPC1 on the monitoring screen and can use all functions of SVMPC1

Remote Access Tablet Access User can access MSMPN1 from anywhere by tablet and PC

User Registration Only authorized user can access MSMPN1

Site Access Limitation Accessible sites can be limited for each user
Access Security
Encrypted Data All data communication through the internet is encrypted by SSL
Communication
8 D’SmartHotel D’SmartHotel 9

OVERVIEW HIGHLIGHTS F E AT U R E S

D’SmartHotel series provides


Energy Efficiency Time Efficiency Smart Air-Conditioner
hotel managers with the tool to
optimise comfort for guests by Save energy with Guest Room Conveniently control air Control and monitor your air-conditioner
remotely monitoring and adjusting Air-Conditioner Interlock Function conditioners in the entire building
the room temperature to an ideal that is able to detect situations with only one controller, instead
desired level before and during such as an open window in an of locating each of the multiple Guest Room Air-Conditioner Interlock
occupancy, hence improving guest air conditioning room. In which controllers in the area. This
satisfaction. This smart control case, D’SmartHotel automatically allows users to save time and Air-conditioner automatically switches off when
system also helps to reduce switches the air conditioner off, conveniently access each and the windows are open, and switches back on
electrical consumption without preventing additional energy every air conditioner in the once they are closed
compromising on the comfort consumption costs. building right at their fingertips.
level and ease of control.
Prioritising Guests’ Comfort
D’SmartHotel assures comfort for
guests right from the beginning of
their stay by ensuring their rooms
are cooled prior to their arrival.
10 D’SmartHotel D’SmartHotel 11

D’SmartHotel F E AT U R E
. Only simple installation work
D’SmartResort F E AT U R E
. Only simple installation work

SVMPS3 SVMPS2
is needed is needed
. Simple setting realizes automatic . Simple setting realizes automatic
air-conditioning control such as air-conditioning control such as
pre-cooling/heating at check-in, pre-cooling/heating at check-in,
stop/setback/change setpoint stop/setback/change setpoint
For controlling air-conditioning of each guestroom according to use by guest For controlling air-conditioning of each villa according to use by guests when leaving
when leaving
Automatic air-conditioning control based on check in and out, leaving and entering rooms, and Automatic air-conditioning control based on check in and out, leaving and entering rooms, and
opening and closing windows. opening and closing windows.

Required Equipment Required Equipment


. Intelligent Touch Manager . SVMPS2 with built-in
. SVMPC1 DTA116A51
. SVMPS3 per 5 guestrooms
* Wifi router and internet environment are
provided by the customer
Operating Conditions
. 1 DTA116A51 can connect up
to 16 indoor units
Operating Conditions
. Control of air-conditioning for . Control of air-conditioning
each guestroom is possible by for each villa is possible by
sending the following signals sending the following signals
to SVMPS3 by dry contact to SVMPS2 by dry contact
. Occupied/unoccupied signal . Check in/check out signal
. Window open/close signal . Occupied/unoccupied signal
. Window open/close signal
. The check in/out signal is sent
from SVMPC1. SVMPC1 and
SVMPS3 connect to LAN and
communicate

SVMPS3 FUNCTIONS SVMPS2 FUNCTIONS

Category Functions Description Category Functions Description

Setpoint Setpoint
Default Setting These settings are used when room is occupied Default Setting These settings are used when room is occupied
Fan Speed Fan Speed

On / Off / Setback FCU operation can be selected after check out On / Off / Setback FCU operation can be selected after check out
Unrented Setting Unrented Setting
Remote Control Operation Remote Control Operation
FCU Operation from Remote Control can be enabled or disabled after check-out FCU Operation from Remote Control can be enabled or disabled after check-out
Enable/ Disable Enable/ Disable

Rented Setting Setpoint Rented Setting Setpoint


These settings are used after check in before being occupied These settings are used after check in before being occupied
(Before Occupied) (Before Occupied)
Fan Speed Fan Speed

Setpoint Unoccupied operation status can be selected. Setpoint Unoccupied operation status can be selected.
On / Off / Setback FCU setpoint setting when ‘On’ is selected On / Off / Setback FCU setpoint setting when ‘On’ is selected

Unoccupied Setting Fan Speed Fan speed setting when setback / ’On’ is selected Unoccupied Setting Fan Speed Fan speed setting when setback / ’On’ is selected

Remote Control Operation Remote Control Operation


FCU Operation from Remote Control can be enabled or disabled when room is unoccupied FCU Operation from Remote Control can be enabled or disabled when room is unoccupied
Enable/ Disable Enable/ Disable

Operation status can be selected when window is opened Operation status can be selected when window is opened
Window Open Setting Off Window Open Setting Off
If stop is not selected, Remote Control can be used when window is opened If stop is not selected, Remote Control can be used when window is opened
12 D’SmartHome D’SmartHome 13

OVERVIEW HIGHLIGHTS
D’SmartHome series lets home
owners control and monitor Daikin
air conditioners using a smartphone Interconnected Home
anywhere and even acts as a D’SmartHome allows users to link up all
centralised remote controller inside their smart devices and conveniently control
the home. various facilities with a simple press of a
button. Enjoy a relaxing and fuss-free time
This system is designed to enhance at home, by letting D’SmartHome take
the comfort and convenience for care of little things like pre-cooling rooms
homeowners, offering complete or drawing curtains
control of core functions in Daikin
air conditioning systems remotely Smart Security
through app access.
Together with Smart Door Lock and Smart
IP Camera, users can easily monitor their
homes 24/7. Save the hassle of getting
home in time to welcome guests or receive
delivery parcels. D’SmartHome allows users
to remotely unlock their Smart Door Lock
and monitor visitors through the Smart
IP Camera.

Safety
Be assured of a safer home, with Smart
Smoke Detector and Motion Sensors. It
immediately alerts its homeowner if an
issue arises, allowing them to take the
required action on time.

F E AT U R E S

Smart Air-Conditioner Energy Consumption Door & Window


Monitoring Security Sensor
Control and monitor your
air-conditioner with automatic Take control of your electrical Notified when the door/
notifications cost by monitoring usage window is opened or closed

Surveillance Camera Smart Electronical Plugs Motorised Curtain


Keep your home safe by Conveniently control electrical Automate your curtains for
monitoring it anytime, anywhere appliances in the space, such as greater convenience
an air purifier.

Smart Digital Lock Smoke Detector Voice Assistant


Lock and unlock doors remotely Sends an alert when smoke is A personal assistant who will
anytime and anywhere detected perform tasks on command

Smart Lighting Control


Achieve optimal lighting with
the ability to control and monitor
your lights *Only Smart Air-Conditioner feature available for D’SmartHome AC, other features not applicable
14 D’SmartHome D’SmartHome 15

D’SmartHome F E AT U R E
. Only simple installation work
D’SmartHome AC F E AT U R E
. Only simple installation work

SVMPH1 SVMPR1
is needed is needed
. Malfunctions are reported . Malfunctions are reported
automatically to the service automatically to the service
contractor for prompt repair. contractor for prompt repair.
When a VRV system is installed at your home When a VRV system is installed at your home
You can easily monitor and control the air-conditioner from anywhere with your smartphone. You can easily monitor and control the air-conditioner from anywhere with your smartphone.
Required Equipment Required Equipment
. DTA116A51 . DTA116A51
. SVMPH1 . SVMPR1
*Wifi router and internet environment are *Wifi router and internet environment are
provided by the customer provided by the customer

Operating Conditions Operating Conditions


. SVMPH1 with 1 DTA116A51 . SVMPR1 with 1 DTA116A51
can connect up to 64 VRV / SA can connect up to 32 VRV / SA
indoor units indoor units
* Residential indoor units require BRP072C42
to connect D’SmartHome

SVMPH1 FUNCTIONS SVMPR1 FUNCTIONS

Category Functions Description Category Functions Description

English, Spanish, Portuguese, Simplified Chinese, Traditional Chinese, Vietnamese, English, Spanish, Portuguese, Simplified Chinese, Traditional Chinese, Vietnamese,
Multi Language Support Multi Language Support
Bahasa (Indonesia), Thai and Japanese Bahasa (Indonesia), Thai and Japanese
Basic Functions Basic Functions
Monitoring Screen Icons display with real-time status updates allows easy navigation and control Monitoring Screen Icons display with real-time status updates allows easy navigation and control

Manual Operation Manually operating is still possible Manual Operation Manually operating is still possible

Schedule Automatic operation depending on date and time can be realized Automatic Control Scene Control Single button controls multiple operations

Automatic Control Interlock Automatic operation depending on status change of management point is realized Energy Saving Off Timer Automatically turn off air conditioner after certain time

Scene Control Single button controls multiple operations Remote Access Smartphone Access User can access to SVMPR1 from anywhere by smartphone, tablet and PC

Energy Saving Off Timer Automatically turn off air conditioner after certain time User Login Username and password required to log in
Access Security
Data Management Energy Graph Electricity consumption per day / month / year can be displayed in bar chart Device Registration Registered device (tablet, smartphone) can access through the internet

Remote Access Smartphone Access User can access to SVMPH1 from anywhere by smartphone, tablet and PC

User Login Username and password required to log in Connectable Devices Air-Conditioner only
Access Security
Device Registration Registered device (tablet, smartphone) can access through the internet

Air-Conditioner, Lighting, IP Camera, Smart Lock, Smart Plugs, Motorised Curtains, Voice Assistant (Google Home),
Connectable Devices
Sensors, Alarms, Smoke Detector
16 Product Overview Product Overview 17

PRODUCT OVERVIEW DEVICE SETTING LISTING

Device Device

Multi-Site D’SmartOffice D’SmartHome


D’SmartOffice D’SmartHome Category Functions D’SmartOffice D’SmartHome
Category Functions D’SmartOffice Management D’SmartHome Touch AC
Touch AC
System
SVMPC1 SVMPC1T SVMPH1 SVMPR1

SVMPC1 SVMPC1T MSMPN1 SVMPH1 SVMPR1 Off Timer

Operation Status Setpoint Range Limitation


(On/Off)
Automatic Setback Operation
Control
Schedule
Operation Mode
(Cool/Heat/Fan/ Interlock
Dry/Auto)
Scene control

Setpoint
Ambient Trend Report
Fan Speed (includes Temperature, Humidity, CO2 Levels)

Air-flow Direction
Energy Graph:
Data Electricity only
Error Notification Electricity / Water Consumption Graph
Status Management
Monitoring
Error Code Tenant Billing *

Filter Sign ^ Operation Report

Room Temperature Malfunction Report


Information
User Registration, Password Setting,
Sensor Information Network Setting

Light Dimming * * System Setting/ Indoor Unit Name & Icon Setting
Display
Door Lock
Multi-Language setting:
Video English, Spanish, Portuguese, Thai, Vietnamese,
Simplified Chinese, Traditional Chinese
On/off

Setpoint
Group Screen:
Operation Mode Number of operating FCU shown on screen.
FCU can be in multiple groups
Fan Speed

Air-flow Direction
Layout Screen:
Manual Dimming * * Custom image for each group and main screen.
Operation Touch screen gestures to zoom and pan
Lock/Unlock

Shutter Open/Close User Login (Username, Password)


Access Security
Filter Sign Clear Device Account Registration

* D’SmartOffice and D’SmartOffice Touch can monitor and control lighting only if Wago system is installed together with SVMPC1/SVMPC1T Remote Software Updates:
^ Not applicable for app version Connection to internet required.
Others
Trouble Shooting:
Error History; System Reset

* Tenant Billing is applicable to D’SmartOffice when iTM is installed together with SVMPC1
18 Product Overview Notes 19

SYSTEM RESUME
Notes
Device Maximum Indoor Unit Connection Interface and Quantity required

64 Indoor Units DTA116A51 X 1


D’SmartOffice SVMPC1
2560 Indoor Units* iTM X 5*

D’SmartOffice Touch SVMPC1T 64 Indoor Units DTA116A51 X 1

Multi-Site Management System MSMPN1 300 Sites

SVMPS3 x 1 (per 5 rooms)


D’SmartHotel SVMPS3 16 Indoor Units
SVMPC1 x 1

D’SmartResort SVMPS2 16 Indoor Units DTA116A51 (built-in) x 1

D’SmartHome SVMPH1 64 Indoor Units DTA116A51 X 1

D’SmartHome AC SVMPR1 32 Indoor Units DTA116A51 X 1

* For AC connection up to 64 Indoor Units, D’SmartOffice can use DTA116A51. For AC connection more than 64 units, iTM should be connected to instead.