D’SmartOffice: Smart Energy Management
D’SmartOffice: Smart Energy Management
Office
Hotel
Home
DHOSCPC2005
2 D’SmartOffice D’SmartOffice 3
OVERVIEW
HIGHLIGHTS F E AT U R E S
D’SmartOffice F E AT U R E
. A smartphone, tablet or PC can
D’SmartOffice Touch F E AT U R E
. A dedicated touch panel
SVMPC1 SVMPC1T
be used to monitor and control to monitor and control air-
air-conditioning from anywhere conditioning with ease
. Malfunctions are reported . Malfunctions are reported
automatically to the service automatically to the service
contractor for prompt repair. contractor for prompt repair.
For easy installation of an air-conditioning management system for For easy installation of an air-conditioning management system for
small to medium buildings . Only simple installation work small to medium buildings . Only simple installation work
is needed is needed
With only simple wiring, smart air-conditioning through centralised control is possible for the With only simple wiring, smart air-conditioning through centralised control is possible for the
entire building. Daily air-conditioning operations can be automated. entire building. Daily air-conditioning operations can be automated.
English, Spanish, Portuguese, Simplified Chinese, Traditional Chinese, Vietnamese, English, Spanish, Portuguese, Simplified Chinese, Traditional Chinese, Vietnamese,
Multi Language Support Multi Language Support
Bahasa (Indonesia), Thai and Japanese Bahasa (Indonesia), Thai and Japanese
Monitoring Screen Icons display with real-time status updates allows easy navigation and control Monitoring Screen Icons display with real-time status updates allows easy navigation and control
Basic Functions Basic Functions
Monitoring Screen (Layout) Icons display according to the layout of building level Monitoring Screen (Layout) Icons display according to the layout of building level
Manual Operation Manually operating is still possible Manual Operation Manually operating is still possible
Schedule Automatic operation depending on date and time can be realized Schedule Automatic operation depending on date and time can be realized
Interlock Automatic operation depending on status change of management point is realized Interlock Automatic operation depending on status change of management point is realized
Automatic Control Automatic Control
Scene Control Single button controls multiple operations Scene Control Single button controls multiple operations
Setback Operation Keeps room at a semi-comfortable temperature with minimum energy Setback Operation Keeps room at a semi-comfortable temperature with minimum energy
Setpoint Range Limitation Prevents setpoint from being set too high/low Setpoint Range Limitation Prevents setpoint from being set too high/low
Energy Saving Energy Saving
Off Timer Automatically turn off air conditioner after certain time Off Timer Automatically turn off air conditioner after certain time
Energy Graph Energy consumption per day / month / year can be displayed in bar chart Energy Graph Energy consumption per day / month / year can be displayed in bar chart
Data Management Trend Graph Analog value like temperature, humidity, etc. can be displayed in line chart Data Management Trend Graph Analog value like temperature, humidity, etc. can be displayed in line chart
Operation History All operation, status change and error infomation are listed with date and time Operation History All operation, status change and error infomation are listed with date and time
Remote Access Smartphone access User can access to SVMPC1 from anywhere by smartphone, tablet and PC Remote Access Smartphone access User can access to SVMPC1T from anywhere by smartphone, tablet and PC
Access Security Only authorised users can access with username and password Access Security Only authorised users can access with username and password
Access Security Device Registration Registered device (tablet, smartphone, PC) can access through the internet Access Security Device Registration Registered device (tablet, smartphone, PC) can access through the internet
D’SmartOffice F E AT U R E
. Various equipment, including
System
Multi-Site Management System Architecture
air-conditioning, can be
operated and monitored
remotely from headquarters.
. Energy can also be monitored
at each facility by connecting a
For remote, centralised control of air-conditioning and other watt meter.
equipment installed at multiple buildings
. Only simple installation work
Centralised control via the Internet is possible for multiple buildings at different locations. is needed
. Malfunctions are reported
automatically to the service
contractor for prompt repair.
Required Equipment
At Individual Site:
. DTA116A51
(Connection of up to 64 indoor units
is possible.)
. SVMPC1
. WAGO I/O system
(This is necessary for equipment
control other than air-conditioning.)
At Headquarters:
. MSMPN1
* WiFi router and Internet environment
are provided by the customer.
Operating Conditions
. One MSMPN1 enables
centralised control of up to
300 buildings at once.
MSMPN1 FUNCTIONS
Site Access Access to site SVMPC1 on the monitoring screen and can use all functions of SVMPC1
Remote Access Tablet Access User can access MSMPN1 from anywhere by tablet and PC
Site Access Limitation Accessible sites can be limited for each user
Access Security
Encrypted Data All data communication through the internet is encrypted by SSL
Communication
8 D’SmartHotel D’SmartHotel 9
OVERVIEW HIGHLIGHTS F E AT U R E S
D’SmartHotel F E AT U R E
. Only simple installation work
D’SmartResort F E AT U R E
. Only simple installation work
SVMPS3 SVMPS2
is needed is needed
. Simple setting realizes automatic . Simple setting realizes automatic
air-conditioning control such as air-conditioning control such as
pre-cooling/heating at check-in, pre-cooling/heating at check-in,
stop/setback/change setpoint stop/setback/change setpoint
For controlling air-conditioning of each guestroom according to use by guest For controlling air-conditioning of each villa according to use by guests when leaving
when leaving
Automatic air-conditioning control based on check in and out, leaving and entering rooms, and Automatic air-conditioning control based on check in and out, leaving and entering rooms, and
opening and closing windows. opening and closing windows.
Setpoint Setpoint
Default Setting These settings are used when room is occupied Default Setting These settings are used when room is occupied
Fan Speed Fan Speed
On / Off / Setback FCU operation can be selected after check out On / Off / Setback FCU operation can be selected after check out
Unrented Setting Unrented Setting
Remote Control Operation Remote Control Operation
FCU Operation from Remote Control can be enabled or disabled after check-out FCU Operation from Remote Control can be enabled or disabled after check-out
Enable/ Disable Enable/ Disable
Setpoint Unoccupied operation status can be selected. Setpoint Unoccupied operation status can be selected.
On / Off / Setback FCU setpoint setting when ‘On’ is selected On / Off / Setback FCU setpoint setting when ‘On’ is selected
Unoccupied Setting Fan Speed Fan speed setting when setback / ’On’ is selected Unoccupied Setting Fan Speed Fan speed setting when setback / ’On’ is selected
Operation status can be selected when window is opened Operation status can be selected when window is opened
Window Open Setting Off Window Open Setting Off
If stop is not selected, Remote Control can be used when window is opened If stop is not selected, Remote Control can be used when window is opened
12 D’SmartHome D’SmartHome 13
OVERVIEW HIGHLIGHTS
D’SmartHome series lets home
owners control and monitor Daikin
air conditioners using a smartphone Interconnected Home
anywhere and even acts as a D’SmartHome allows users to link up all
centralised remote controller inside their smart devices and conveniently control
the home. various facilities with a simple press of a
button. Enjoy a relaxing and fuss-free time
This system is designed to enhance at home, by letting D’SmartHome take
the comfort and convenience for care of little things like pre-cooling rooms
homeowners, offering complete or drawing curtains
control of core functions in Daikin
air conditioning systems remotely Smart Security
through app access.
Together with Smart Door Lock and Smart
IP Camera, users can easily monitor their
homes 24/7. Save the hassle of getting
home in time to welcome guests or receive
delivery parcels. D’SmartHome allows users
to remotely unlock their Smart Door Lock
and monitor visitors through the Smart
IP Camera.
Safety
Be assured of a safer home, with Smart
Smoke Detector and Motion Sensors. It
immediately alerts its homeowner if an
issue arises, allowing them to take the
required action on time.
F E AT U R E S
D’SmartHome F E AT U R E
. Only simple installation work
D’SmartHome AC F E AT U R E
. Only simple installation work
SVMPH1 SVMPR1
is needed is needed
. Malfunctions are reported . Malfunctions are reported
automatically to the service automatically to the service
contractor for prompt repair. contractor for prompt repair.
When a VRV system is installed at your home When a VRV system is installed at your home
You can easily monitor and control the air-conditioner from anywhere with your smartphone. You can easily monitor and control the air-conditioner from anywhere with your smartphone.
Required Equipment Required Equipment
. DTA116A51 . DTA116A51
. SVMPH1 . SVMPR1
*Wifi router and internet environment are *Wifi router and internet environment are
provided by the customer provided by the customer
English, Spanish, Portuguese, Simplified Chinese, Traditional Chinese, Vietnamese, English, Spanish, Portuguese, Simplified Chinese, Traditional Chinese, Vietnamese,
Multi Language Support Multi Language Support
Bahasa (Indonesia), Thai and Japanese Bahasa (Indonesia), Thai and Japanese
Basic Functions Basic Functions
Monitoring Screen Icons display with real-time status updates allows easy navigation and control Monitoring Screen Icons display with real-time status updates allows easy navigation and control
Manual Operation Manually operating is still possible Manual Operation Manually operating is still possible
Schedule Automatic operation depending on date and time can be realized Automatic Control Scene Control Single button controls multiple operations
Automatic Control Interlock Automatic operation depending on status change of management point is realized Energy Saving Off Timer Automatically turn off air conditioner after certain time
Scene Control Single button controls multiple operations Remote Access Smartphone Access User can access to SVMPR1 from anywhere by smartphone, tablet and PC
Energy Saving Off Timer Automatically turn off air conditioner after certain time User Login Username and password required to log in
Access Security
Data Management Energy Graph Electricity consumption per day / month / year can be displayed in bar chart Device Registration Registered device (tablet, smartphone) can access through the internet
Remote Access Smartphone Access User can access to SVMPH1 from anywhere by smartphone, tablet and PC
User Login Username and password required to log in Connectable Devices Air-Conditioner only
Access Security
Device Registration Registered device (tablet, smartphone) can access through the internet
Air-Conditioner, Lighting, IP Camera, Smart Lock, Smart Plugs, Motorised Curtains, Voice Assistant (Google Home),
Connectable Devices
Sensors, Alarms, Smoke Detector
16 Product Overview Product Overview 17
Device Device
Setpoint
Ambient Trend Report
Fan Speed (includes Temperature, Humidity, CO2 Levels)
Air-flow Direction
Energy Graph:
Data Electricity only
Error Notification Electricity / Water Consumption Graph
Status Management
Monitoring
Error Code Tenant Billing *
Light Dimming * * System Setting/ Indoor Unit Name & Icon Setting
Display
Door Lock
Multi-Language setting:
Video English, Spanish, Portuguese, Thai, Vietnamese,
Simplified Chinese, Traditional Chinese
On/off
Setpoint
Group Screen:
Operation Mode Number of operating FCU shown on screen.
FCU can be in multiple groups
Fan Speed
Air-flow Direction
Layout Screen:
Manual Dimming * * Custom image for each group and main screen.
Operation Touch screen gestures to zoom and pan
Lock/Unlock
* D’SmartOffice and D’SmartOffice Touch can monitor and control lighting only if Wago system is installed together with SVMPC1/SVMPC1T Remote Software Updates:
^ Not applicable for app version Connection to internet required.
Others
Trouble Shooting:
Error History; System Reset
* Tenant Billing is applicable to D’SmartOffice when iTM is installed together with SVMPC1
18 Product Overview Notes 19
SYSTEM RESUME
Notes
Device Maximum Indoor Unit Connection Interface and Quantity required
* For AC connection up to 64 Indoor Units, D’SmartOffice can use DTA116A51. For AC connection more than 64 units, iTM should be connected to instead.
Daikin Holdings
Singapore Pte Ltd
Address
10 Ang Mo Kio Industrial Park 2,
Singapore 569501
Main Line
6583 8888
@ Email
[email protected]