0% found this document useful (0 votes)
176 views4 pages

AGA 14 3 Meter Tube Pipe Lengths

This document provides standard meter tube lengths according to AGA/API 14.3 - 2000. It lists upstream and downstream lengths for 2, 3, and multi-section meter tubes with and without vanes or conditioners. Lengths are specified based on tube diameter and configuration.

Uploaded by

Abby
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
176 views4 pages

AGA 14 3 Meter Tube Pipe Lengths

This document provides standard meter tube lengths according to AGA/API 14.3 - 2000. It lists upstream and downstream lengths for 2, 3, and multi-section meter tubes with and without vanes or conditioners. Lengths are specified based on tube diameter and configuration.

Uploaded by

Abby
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

(MIN) STANDARD METER TUBE LENGTHS PER AGA/API 14.

3 - 2000

No Conditioner or Vane
Upstream lengths (UL) are based on the largest expected published I.D. for a given size and
rounded up to nearest inch at 44D. Downstream lengths exceed the minimum recommended
minimum length. All downstream lengths (DL) are complete with (2) each 1/2" and (1) 3/4"
threadolet or coupling, spaced 6” apart.
2 SECTION METER TUBES
SIZE UL (44D) DL (4.5D +24”)
2 7'-10" 3'-0"
3 11'-4" 3'-6"
4 14'-13" 4'-0"
6 22'-4" 4'-6"
8 29’-5” 5'-0"
10 36’-12” 6'-0"
12 43’-13” 6'-6"
14 48’-3” 7'-0"
16 55’-0” 8'-0"
18 62’-0” 8'-6"
20 69’-0” 9'-6"
24 83’-0” 10'-8"

19 – Tube Bundle LSV


Upstream lengths (UL) are based on the largest expected published I.D. for a given size and
rounded up to nearest inch at 29D. Downstream lengths exceed the minimum recommended
minimum length. All downstream lengths (DL) are complete with (2) each 1/2" and (1) 3/4"
threadolet or coupling, spaced 6” apart.
2 SECTION METER TUBES W/ VANES
SIZE UPSTREAM DOWNSTREAM VANE LOCATION VL
2* 5'-0" 3'-0"
3 7'-5" 4'-0" 3'-8"
4 9'-9" 4'-0" 4'-10"
6 14'-8" 5'-0" 7'-1"
8 19'-8" 5'-0" 9'-6"
10 24'-10" 6'-0" 12'-0"
12** 29'-8" 7'-0" 13'-5-1/2" / 15'-2-1/2"
14** 32'-4" 8'-7" 14'-7-1/2" / 16'-8-1/2"
16** 37'-2" 9'-4" 18'-1-1/2" /20'-6-1/2"
18** 42'-0" 10'-1" 20'-5-1/2" / 23'-2-1/2"
20** 46'-7" 10'-11" 22'-8-1/2" / 25'-9-1/2"
24** 56'-3" 12'-7" 27'-4-1/2" / 31'-1-1/2"
*2" vanes are not available at this time, in any schedule. See Profiler for 2" sizes
**12" and larger have 2 setscrews. Numbers shown are to 1st, then to 2nd setscrew
2 section tubes 3 Section tubes
3 SECTION METER TUBES WITH FLANGED TYPE VANES
SIZE UPSTEAM INLET SPOOL UPSTREAM SPOOL DOWNSTREAM
LENGTH including vane flange(s), Flange face to orifice LENGTH
TOTAL 3 gaskets and 1/2" spacer plate centerline
plate Catalog "S" Catalog "U"
2* 5'-0" 2'-3" 2'-9" 3'-0"
3 7'-5" 3'-5" 4'-0" 4'-0"
4 9'-9" 4'-6" 5'-3" 4'-0"
6 14'-8" 7'-1" 7'-7" 5'-0"
8 19'-8" 9'-6" 10'-2" 5'-0"
10 24'-10" 12'-0" 12'-10" 6'-0"
12 29'-8" 14'-4" 15'-4" 7'-0"
14 32'-4" 15'-6" 16'-10" 8'-7"
16 37'-2" 17'-10" 19'-4" 9'-4"
18 42'-0" 20'-2" 21'-10" 10'-1"
20 46'-7" 22'-4" 24'-3" 10'-11"
24 56'-3" 27'-0" 29'-3" 12'-7"
*2" vanes are not available at this time, in any schedule. See Profiler for 2" sizes

3 SECTION METER TUBES WITH PROFILER


SIZE UPSTEAM INLET SPOOL UPSTREAM SPOOL DOWNSTREAM
LENGTH including 1/2" spacer Flange face to orifice LENGTH
TOTAL plate (9.5D min) plate centerline
2 3'-4" 1'-11" 1'-5" 3'-0"
3 4'-7" 2'-7" 2'-0" 4'-0"
4 6'-1" 3'-4" 2'-9" 4'-0"
6 8'-10" 4'-13" 3'-13" 5'-0"
8 11'-6" 6'-6" 5'-0" 5'-0"
10 14'-5" 8'-0" 6'-5" 6'-0"
12 17'-4" 9'-8" 7'-8" 7'-0"
14 18'-11" 10'-7" 8'-4" 8'-7"
16 19'-7" 12'-0" 9'-7" 9'-4"
18 24'-3" 13'-6" 10'-9" 10'-1"
20 26'-13" 15'-0" 11'-13" 10'-11"
24 32'-3" 18'-0" 14'-3" 12'-7"

Note: Minimum Length Upstream for TOL/HC is 36” from Profiler or Vane inlet.
(MIN) STANDARD METER TUBE LENGTHS PER AGA/API 14.3 - 2002

No Conditioner or Vane
Upstream lengths (UL) are based on the largest expected published I.D. for a given size and
rounded up to nearest inch at 44D. Downstream lengths exceed the minimum recommended
minimum length. All downstream lengths (DL) are complete with (2) each 1/2" and (1) 3/4"
threadolet or coupling, spaced 6” apart.
2 SECTION METER TUBES
SIZE UL (44D) DL (4.5D +24”)
2 7'-10" 3'-0"
3 11'-4" 3'-6"
4 14'-13" 4'-0"
6 22'-4" 4'-6"
8 29’-5” 5'-0"
10 36’-12” 6'-0"
12 43’-13” 6'-6"
14 48’-3” 7'-0"
16 55’-0” 8'-0"
18 62’-0” 8'-6"
20 69’-0” 9'-6"
24 83’-0” 10'-8"

19 – Tube Bundle LSV


Upstream lengths (UL) are based on the largest expected published I.D. for a given size and
rounded up to nearest inch at 29D. Downstream lengths exceed the minimum recommended
minimum length. All downstream lengths (DL) are complete with (2) each 1/2" and (1) 3/4"
threadolet or coupling, spaced 6” apart.
2 SECTION METER TUBES W/ VANES
SIZE UPSTREAM DOWNSTREAM VANE LOCATION VL
2* 5'-0" 3'-0"
3 7'-5" 4'-0" 3'-8"
4 9'-9" 4'-0" 4'-10"
6 14'-8" 5'-0" 7'-1"
8 19'-8" 5'-0" 9'-6"
10 24'-10" 6'-0" 12'-0"
12** 29'-8" 7'-0" 13'-5-1/2" / 15'-2-1/2"
14** 32'-4" 8'-7" 14'-7-1/2" / 16'-8-1/2"
16** 37'-2" 9'-4" 18'-1-1/2" /20'-6-1/2"
18** 42'-0" 10'-1" 20'-5-1/2" / 23'-2-1/2"
20** 46'-7" 10'-11" 22'-8-1/2" / 25'-9-1/2"
24** 56'-3" 12'-7" 27'-4-1/2" / 31'-1-1/2"
*2" vanes are not available at this time, in any schedule. See Profiler for 2" sizes
**12" and larger have 2 setscrews. Numbers shown are to 1st, then to 2nd setscrew
3 SECTION METER TUBES WITH FLANGED TYPE VANES
SIZE UPSTEAM INLET SPOOL UPSTREAM SPOOL DOWNSTREAM
LENGTH including vane flange(s), Flange face to orifice LENGTH
TOTAL 3 gaskets and 1/2" spacer plate centerline
plate Catalog "S" Catalog "U"
2* 5'-0" 2'-3" 2'-9" 3'-0"
3 7'-5" 3'-5" 4'-0" 4'-0"
4 9'-9" 4'-6" 5'-3" 4'-0"
6 14'-8" 7'-1" 7'-7" 5'-0"
8 19'-8" 9'-6" 10'-2" 5'-0"
10 24'-10" 12'-0" 12'-10" 6'-0"
12 29'-8" 14'-4" 15'-4" 7'-0"
14 32'-4" 15'-6" 16'-10" 8'-7"
16 37'-2" 17'-10" 19'-4" 9'-4"
18 42'-0" 20'-2" 21'-10" 10'-1"
20 46'-7" 22'-4" 24'-3" 10'-11"
24 56'-3" 27'-0" 29'-3" 12'-7"
*2" vanes are not available at this time, in any schedule. See Profiler for 2" sizes

3 SECTION METER TUBES WITH PROFILER


SIZE UPSTEAM INLET SPOOL UPSTREAM SPOOL DOWNSTREAM
LENGTH including 1/2" spacer Flange face to orifice LENGTH
TOTAL plate (9.5D min) plate centerline
2 3'-4" 1'-11" 1'-5" 3'-0"
3 4'-7" 2'-7" 2'-0" 4'-0"
4 6'-1" 3'-4" 2'-9" 4'-0"
6 8'-10" 4'-13" 3'-13" 5'-0"
8 11'-6" 6'-6" 5'-0" 5'-0"
10 14'-5" 8'-0" 6'-5" 6'-0"
12 17'-4" 9'-8" 7'-8" 7'-0"
14 18'-11" 10'-7" 8'-4" 8'-7"
16 19'-7" 12'-0" 9'-7" 9'-4"
18 24'-3" 13'-6" 10'-9" 10'-1"
20 26'-13" 15'-0" 11'-13" 10'-11"
24 32'-3" 18'-0" 14'-3" 12'-7"

Note: Minimum Length Upstream for TOL/HC is 36” from Profiler or Vane inlet.