(MIN) STANDARD METER TUBE LENGTHS PER AGA/API 14.
3 - 2000
No Conditioner or Vane
Upstream lengths (UL) are based on the largest expected published I.D. for a given size and
rounded up to nearest inch at 44D. Downstream lengths exceed the minimum recommended
minimum length. All downstream lengths (DL) are complete with (2) each 1/2" and (1) 3/4"
threadolet or coupling, spaced 6” apart.
2 SECTION METER TUBES
SIZE UL (44D) DL (4.5D +24”)
2 7'-10" 3'-0"
3 11'-4" 3'-6"
4 14'-13" 4'-0"
6 22'-4" 4'-6"
8 29’-5” 5'-0"
10 36’-12” 6'-0"
12 43’-13” 6'-6"
14 48’-3” 7'-0"
16 55’-0” 8'-0"
18 62’-0” 8'-6"
20 69’-0” 9'-6"
24 83’-0” 10'-8"
19 – Tube Bundle LSV
Upstream lengths (UL) are based on the largest expected published I.D. for a given size and
rounded up to nearest inch at 29D. Downstream lengths exceed the minimum recommended
minimum length. All downstream lengths (DL) are complete with (2) each 1/2" and (1) 3/4"
threadolet or coupling, spaced 6” apart.
2 SECTION METER TUBES W/ VANES
SIZE UPSTREAM DOWNSTREAM VANE LOCATION VL
2* 5'-0" 3'-0"
3 7'-5" 4'-0" 3'-8"
4 9'-9" 4'-0" 4'-10"
6 14'-8" 5'-0" 7'-1"
8 19'-8" 5'-0" 9'-6"
10 24'-10" 6'-0" 12'-0"
12** 29'-8" 7'-0" 13'-5-1/2" / 15'-2-1/2"
14** 32'-4" 8'-7" 14'-7-1/2" / 16'-8-1/2"
16** 37'-2" 9'-4" 18'-1-1/2" /20'-6-1/2"
18** 42'-0" 10'-1" 20'-5-1/2" / 23'-2-1/2"
20** 46'-7" 10'-11" 22'-8-1/2" / 25'-9-1/2"
24** 56'-3" 12'-7" 27'-4-1/2" / 31'-1-1/2"
*2" vanes are not available at this time, in any schedule. See Profiler for 2" sizes
**12" and larger have 2 setscrews. Numbers shown are to 1st, then to 2nd setscrew
2 section tubes 3 Section tubes
3 SECTION METER TUBES WITH FLANGED TYPE VANES
SIZE UPSTEAM INLET SPOOL UPSTREAM SPOOL DOWNSTREAM
LENGTH including vane flange(s), Flange face to orifice LENGTH
TOTAL 3 gaskets and 1/2" spacer plate centerline
plate Catalog "S" Catalog "U"
2* 5'-0" 2'-3" 2'-9" 3'-0"
3 7'-5" 3'-5" 4'-0" 4'-0"
4 9'-9" 4'-6" 5'-3" 4'-0"
6 14'-8" 7'-1" 7'-7" 5'-0"
8 19'-8" 9'-6" 10'-2" 5'-0"
10 24'-10" 12'-0" 12'-10" 6'-0"
12 29'-8" 14'-4" 15'-4" 7'-0"
14 32'-4" 15'-6" 16'-10" 8'-7"
16 37'-2" 17'-10" 19'-4" 9'-4"
18 42'-0" 20'-2" 21'-10" 10'-1"
20 46'-7" 22'-4" 24'-3" 10'-11"
24 56'-3" 27'-0" 29'-3" 12'-7"
*2" vanes are not available at this time, in any schedule. See Profiler for 2" sizes
3 SECTION METER TUBES WITH PROFILER
SIZE UPSTEAM INLET SPOOL UPSTREAM SPOOL DOWNSTREAM
LENGTH including 1/2" spacer Flange face to orifice LENGTH
TOTAL plate (9.5D min) plate centerline
2 3'-4" 1'-11" 1'-5" 3'-0"
3 4'-7" 2'-7" 2'-0" 4'-0"
4 6'-1" 3'-4" 2'-9" 4'-0"
6 8'-10" 4'-13" 3'-13" 5'-0"
8 11'-6" 6'-6" 5'-0" 5'-0"
10 14'-5" 8'-0" 6'-5" 6'-0"
12 17'-4" 9'-8" 7'-8" 7'-0"
14 18'-11" 10'-7" 8'-4" 8'-7"
16 19'-7" 12'-0" 9'-7" 9'-4"
18 24'-3" 13'-6" 10'-9" 10'-1"
20 26'-13" 15'-0" 11'-13" 10'-11"
24 32'-3" 18'-0" 14'-3" 12'-7"
Note: Minimum Length Upstream for TOL/HC is 36” from Profiler or Vane inlet.
(MIN) STANDARD METER TUBE LENGTHS PER AGA/API 14.3 - 2002
No Conditioner or Vane
Upstream lengths (UL) are based on the largest expected published I.D. for a given size and
rounded up to nearest inch at 44D. Downstream lengths exceed the minimum recommended
minimum length. All downstream lengths (DL) are complete with (2) each 1/2" and (1) 3/4"
threadolet or coupling, spaced 6” apart.
2 SECTION METER TUBES
SIZE UL (44D) DL (4.5D +24”)
2 7'-10" 3'-0"
3 11'-4" 3'-6"
4 14'-13" 4'-0"
6 22'-4" 4'-6"
8 29’-5” 5'-0"
10 36’-12” 6'-0"
12 43’-13” 6'-6"
14 48’-3” 7'-0"
16 55’-0” 8'-0"
18 62’-0” 8'-6"
20 69’-0” 9'-6"
24 83’-0” 10'-8"
19 – Tube Bundle LSV
Upstream lengths (UL) are based on the largest expected published I.D. for a given size and
rounded up to nearest inch at 29D. Downstream lengths exceed the minimum recommended
minimum length. All downstream lengths (DL) are complete with (2) each 1/2" and (1) 3/4"
threadolet or coupling, spaced 6” apart.
2 SECTION METER TUBES W/ VANES
SIZE UPSTREAM DOWNSTREAM VANE LOCATION VL
2* 5'-0" 3'-0"
3 7'-5" 4'-0" 3'-8"
4 9'-9" 4'-0" 4'-10"
6 14'-8" 5'-0" 7'-1"
8 19'-8" 5'-0" 9'-6"
10 24'-10" 6'-0" 12'-0"
12** 29'-8" 7'-0" 13'-5-1/2" / 15'-2-1/2"
14** 32'-4" 8'-7" 14'-7-1/2" / 16'-8-1/2"
16** 37'-2" 9'-4" 18'-1-1/2" /20'-6-1/2"
18** 42'-0" 10'-1" 20'-5-1/2" / 23'-2-1/2"
20** 46'-7" 10'-11" 22'-8-1/2" / 25'-9-1/2"
24** 56'-3" 12'-7" 27'-4-1/2" / 31'-1-1/2"
*2" vanes are not available at this time, in any schedule. See Profiler for 2" sizes
**12" and larger have 2 setscrews. Numbers shown are to 1st, then to 2nd setscrew
3 SECTION METER TUBES WITH FLANGED TYPE VANES
SIZE UPSTEAM INLET SPOOL UPSTREAM SPOOL DOWNSTREAM
LENGTH including vane flange(s), Flange face to orifice LENGTH
TOTAL 3 gaskets and 1/2" spacer plate centerline
plate Catalog "S" Catalog "U"
2* 5'-0" 2'-3" 2'-9" 3'-0"
3 7'-5" 3'-5" 4'-0" 4'-0"
4 9'-9" 4'-6" 5'-3" 4'-0"
6 14'-8" 7'-1" 7'-7" 5'-0"
8 19'-8" 9'-6" 10'-2" 5'-0"
10 24'-10" 12'-0" 12'-10" 6'-0"
12 29'-8" 14'-4" 15'-4" 7'-0"
14 32'-4" 15'-6" 16'-10" 8'-7"
16 37'-2" 17'-10" 19'-4" 9'-4"
18 42'-0" 20'-2" 21'-10" 10'-1"
20 46'-7" 22'-4" 24'-3" 10'-11"
24 56'-3" 27'-0" 29'-3" 12'-7"
*2" vanes are not available at this time, in any schedule. See Profiler for 2" sizes
3 SECTION METER TUBES WITH PROFILER
SIZE UPSTEAM INLET SPOOL UPSTREAM SPOOL DOWNSTREAM
LENGTH including 1/2" spacer Flange face to orifice LENGTH
TOTAL plate (9.5D min) plate centerline
2 3'-4" 1'-11" 1'-5" 3'-0"
3 4'-7" 2'-7" 2'-0" 4'-0"
4 6'-1" 3'-4" 2'-9" 4'-0"
6 8'-10" 4'-13" 3'-13" 5'-0"
8 11'-6" 6'-6" 5'-0" 5'-0"
10 14'-5" 8'-0" 6'-5" 6'-0"
12 17'-4" 9'-8" 7'-8" 7'-0"
14 18'-11" 10'-7" 8'-4" 8'-7"
16 19'-7" 12'-0" 9'-7" 9'-4"
18 24'-3" 13'-6" 10'-9" 10'-1"
20 26'-13" 15'-0" 11'-13" 10'-11"
24 32'-3" 18'-0" 14'-3" 12'-7"
Note: Minimum Length Upstream for TOL/HC is 36” from Profiler or Vane inlet.