This document provides release notes for firmware versions of products CPU 9442/3x and PM 9445/3x. The most recent version is SWU 01.01.03 from May 23, 2023 which fixes a bug in the calculation of current in Zone 1 for PM modules. Earlier versions provided various bug fixes and new features related to firmware updates, redundancy, temperature compensation, and other improvements. Known issues remain with certain module configurations and updating older PM modules.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0 ratings0% found this document useful (0 votes)
35 views3 pages
Release Notes 9442
This document provides release notes for firmware versions of products CPU 9442/3x and PM 9445/3x. The most recent version is SWU 01.01.03 from May 23, 2023 which fixes a bug in the calculation of current in Zone 1 for PM modules. Earlier versions provided various bug fixes and new features related to firmware updates, redundancy, temperature compensation, and other improvements. Known issues remain with certain module configurations and updating older PM modules.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3
Product Information
CPU 9442/3x and PM 9445/3x - Firmware Release Notes
SWU 01.01.03 Release Date 23.05.2023 New Features -- -- Bugfix PM • Correct calculation of current in Zone 1 PM Known Bugs CPU • 9468/ and 9469/ with 8AO + 4 HV or 8 AO + 8 HV does not work - Configure module as 8AI/AO + HART PV Remarks Firmware identical to version SWU 01.00.25, only PM firmware changed
SWU 01.01.02 Release Date 16.05.2023
New Features -- -- EN Bugfix PM • Update of all power module firmware versions to this version is possible Known Bugs CPU • 9468/ and 9469/ with 8AO + 4 HV or 8 AO + 8 HV does not work - Configure module as 8AI/AO + HART PV PM • Current of Zone 1 PM not correct. Maintenance LED can be switched on - Update to 01.01.03 Remarks Firmware identical to version SWU 01.00.25, only PM firmware changed
SWU 01.01.01 Release Date 03.05.2023
New Features -- -- Bugfix PM • use correct temperature correction in current measurement PM zone 2 Known Bugs CPU • 9468/ and 9469/ with 8AO + 4 HV or 8 AO + 8 HV does not work - Configure module as 8AI/AO + HART PV PM • PM with FW < 01.00.25 cannot be updated and will switch of power. - restarted using separate power supply (using SWU 99.00.00) - updated to 01.00.25 prior - If updated once to 01.01.01 or later, any update is possible Remarks Firmware identical to version SWU 01.00.25, only PM firmware changed
SWU 01.01.00 Release Date 04.04.2023
New Features PM • Improved load balancing in redundant mode • Switch output off faster if power is disconnected • add support for new PM Z1 • Use constant output voltage while in boot mode Bugfix PM • Problem with firmware update solved. Some PM got stuck in download mode and switched output off Known Bugs CPU • 9468/ and 9469/ with 8AO + 4 HV or 8 AO + 8 HV does not work - Configure module as 8AI/AO + HART PV PM • PM with a FW < 01.00.25 cannot be updated and will switch of power. - PM can be restarted with a separate power supply (use SWU 99.00.00) - If system is updated to 01.00.25 prior, it can be updated to 01.01.00 • Skipped temperature compensation of current measurement PM zone 2, values in webserver too high Remarks Firmware identical to version SWU 01.00.25, only PM firmware changed
Firmware Release Notes
Series 9442/3x and 9445/3x 2023-05-23 PI00 III en 01 Product Information
SWU 01.00.25 Release Date 23.11.2022
New Features CPU • Password reset PM • Switch off red. PM while other PM is in update. • Serial firmware download of redundant PM Bugfix CPU • Improved redundancy switching • Webserver - Show DI instead of DO, fix text - Correct display of CPU zone 1 PM • Fixed power on problem • Serial firmware download • Switch off PWR OUT LED if power supply of PM is removed Known Bugs CPU • 9468/ and 9469/ with 8AO + 4 HV or 8 AO + 8 HV does not work - Configure module as 8AI/AO + HART PV Remarks
SWU 01.00.24 Release Date 28.03.2022
New CPU • HART communication over backup CPU Features • Add support for virtual COM port EN • Add OPC UA demo mode in standard CPU • Add NTP support • Add global data (field station name, location, comments….) available in both redundant CPU • Add support for IOM redundancy • Add PROFINET extensions • Improved Web diagnostics • Licenses loadable via webserver • Add support for HEX decoders of socket (9496\) Bugfix CPU • Extend PROFINET to 1024 Bytes • Boot from sockets from factory (empty sockets) PM • Improve PM redundancy Known Bugs PM • Power on problem may occur Remarks --
SWU 01.00.23 Release Date 26.10.2020
New Features -- -- Bugfix CPU • Optimize timeout on backplane Known Bugs -- -- Remarks --
SWU 01.00.22 Release Date 22.09.2020
New Features CPU • Webserver extended history • Webserver timesync with PC • IS1+ Virtual Com port support Bugfix PM • no maintenance alarm of red. PM, with a switched off PM Known Bugs CPU • Update from SWU 01.00.21 requires a power on to show correct PM information Remarks No official release
Firmware Release Notes
Series 9442/3x and 9445/3x 2023-05-23 PI00 III en 01 Product Information
SWU 01.00.21 Release Date 09.07.2020
New Features CPU • PROFIBUS DP • New PROFINET stack Bug Fixes CPU • Webserver Known Bugs -- -- Remarks --
SWU 01.00.18 Release Date 19.03.2020
New Features CPU • PROFIBUS DP Bugfix CPU • PROFIBUS DP • Webserver Known Bugs -- -- Remarks --
SWU 01.00.17 Release Date 11.02.2020
New Features -- -- Bugfix CPU • Synchronization between redundant CPU • Webserver Known Bugs -- -- Remarks --
SWU 01.00.16 Release Date 11.09.2019
New Features -- -- Bugfix CPU • Synchronization between redundant CPU EN Known Bugs CPU • HART over PROFIBUS DP not working • No slave startup on PROFIBUS DP • RS485 only point to point connection Remarks --
SWU 01.00.11 Release Date 06.02.2019
New Features CPU • All protocols implemented Bugfix CPU • Synchronization between redundant CPU Known Bugs CPU • No HART communication on inactive CPU • No update of inactive CPU if other CPU is active • RS485 only point to point connection Remarks --