Products Solutions Services
Proline Promass F 200
Coriolis flowmeter
Robust flowmeter with genuine loop-powered
technology
F L E X Benefícios:
• Highest process safety – immune to fluctuating and harsh
environments
• Fewer process measuring points – multivariable measurement (flow,
density, temperature)
• Space-saving installation – no in/outlet run needs
• Convenient device wiring – separate connection compartment
• Safe operation – no need to open the device due to display with touch
control, background lighting
• Integrated verification – Heartbeat Technology
Especificações resumidas
• Max. measurement error Mass flow (liquid): ±0.1 % Volume flow
Mais informações e preço atual: (liquid): ±0.1 % Mass flow (gas): ±0.25 % Density (liquid):
www.br.endress.com/8F2B ±0.0005 g/cm³
• Measuring range 0 to 70 000 kg/h (0 to 2570 lb/min)
• Medium temperature range Standard: –50 to +150 °C (–58 to
+302 °F) Option: –50 to +205 °C (–58 to +401 °F)
• Max. process pressure PN 100, Class 600, 63K
• Wetted materials Measuring tube: 1.4539 (904L); 1.4404 ; Alloy
C22, 2.4602 (UNS N06022) Connection: 1.4404 (316/316L);
Alloy C22, 2.4602 (UNS N06022)
Campo de aplicação: Promass F has a long standing reputation as a
highly accurate device. It is suited for broadest range of applications.
Promass F 200 offers in addition genuine, industry-compliant two-wire
technology. This enables seamless system integration into existing
infrastructures. Additional advantages are high operational safety in
Proline Promass F 200 / 8F2B
hazardous areas thanks to an intrinsically safe design (Ex ia) and process
safety at all times ensured by Heartbeat Technology.
Características e especificações
Liquids Measuring principle
Coriolis
Product headline
Robust flowmeter with genuine loop-powered technology.
Highest measurement performance for liquids and gases in a wide range
of applications.
Sensor features
Highest process safety – immune to fluctuating and harsh environments.
Fewer process measuring points – multivariable measurement (flow,
density, temperature). Space‐saving installation – no in-/outlet run
needs.
Mass flow: measured error ±0.1 %. Medium temperature up to +205 °C
(+401 °F). Nominal diameter: DN 8 to 80 (³⁄₈ to 3").
Transmitter features
Convenient device wiring – separate connection compartment. Safe
operation – no need to open the device due to display with touch control,
background lighting. Integrated verification – Heartbeat Technology.
Loop-powered technology. Robust dual-compartment housing. Plant
safety: worldwide approvals (SIL, Haz. area).
Nominal diameter range
DN 8 to 80 (⅜ to 3")
Wetted materials
Measuring tube: 1.4539 (904L); 1.4404; Alloy C22, 2.4602 (UNS
N06022)
Connection: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022)
2 Endress+Hauser
Proline Promass F 200 / 8F2B
Liquids Measured variables
Mass flow, density, temperature, volume flow, corrected volume flow,
reference density
Max. measurement error
Mass flow (liquid): ±0.1 %
Volume flow (liquid): ±0.1 %
Mass flow (gas): ±0.25 % Density (liquid): ±0.0005 g/cm³
Measuring range
0 to 70 000 kg/h (0 to 2570 lb/min)
Max. process pressure
PN 100, Class 600, 63K
Medium temperature range
Standard: –50 to +150 °C (–58 to +302 °F)
Option: –50 to +205 °C (–58 to +401 °F)
Ambient temperature range
–40 to +60 °C (–40 to +140 °F)
Sensor housing material
1.4301/1.4307 (304L), corrosion resistant
Transmitter housing material
AlSi10Mg, coated, 1.4404 (316L)
Degree of protection
IP66/67, type 4X enclosure
Display/Operation
4‐line backlit display with touch control
(operation from outside)
Configuration via local display and operating tools possible
Remote display available
3 Endress+Hauser
Proline Promass F 200 / 8F2B
Liquids Outputs
4‐20 mA HART (passive)
4‐20 mA (passive)
Pulse/frequency/switch output (passive)
Inputs
None
Digital communication
HART, PROFIBUS PA, FOUNDATION Fieldbus
Power supply
DC 18 to 35 V (4‐20 mA HART with/without
pulse/frequency/switch)
DC 18 to 30 V (20 mA HART, 4‐20 mA)
DC 9 to 32 V (PROFIBUS PA)
Hazardous area approvals
ATEX, IECEx, cCSAus, INMETRO, NEPSI, JPN, UK Ex
Product safety
CE, C-TICK
Functional safety
Functional safety according to IEC 61508, applicable in safety-relevant
applications in accordance with IEC 61511
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC
17025)
Heartbeat Technology complies with the requirements for measurement
traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD
attestation)
Pressure approvals and certificates
PED, CRN, AD 2000
4 Endress+Hauser
Proline Promass F 200 / 8F2B
Liquids Material certificates
3.1 material
NACE MR0175/MR0103, PMI; welding test acc. to EN ISO, ASME,
NORSOK
Hygienic approvals and certificates
3-A, EHEDG, cGMP
Gas Measuring principle
Coriolis
Product headline
Robust flowmeter with genuine loop-powered technology.
Highest measurement performance for liquids and gases in a wide range
of applications.
Sensor features
Highest process safety – immune to fluctuating and harsh environments.
Fewer process measuring points – multivariable measurement (flow,
density, temperature). Space‐saving installation – no in-/outlet run
needs.
Mass flow: measured error ±0.1 %. Medium temperature up to +205 °C
(+401 °F). Nominal diameter: DN 8 to 80 (³⁄₈ to 3").
Transmitter features
Convenient device wiring – separate connection compartment. Safe
operation – no need to open the device due to display with touch control,
background lighting. Integrated verification – Heartbeat Technology.
Loop-powered technology. Robust dual-compartment housing. Plant
safety: worldwide approvals (SIL, Haz. area).
Nominal diameter range
DN 8 to 80 (⅜ to 3")
5 Endress+Hauser
Proline Promass F 200 / 8F2B
Gas Wetted materials
Measuring tube: 1.4539 (904L); 1.4404 ; Alloy C22, 2.4602 (UNS
N06022)
Connection: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022)
Measured variables
Mass flow, density, temperature, volume flow, corrected volume flow,
reference density
Max. measurement error
Mass flow (liquid): ±0.1 %
Volume flow (liquid): ±0.1 %
Mass flow (gas): ±0.25 % Density (liquid): ±0.0005 g/cm³
Measuring range
0 to 70 000 kg/h (0 to 2570 lb/min)
Max. process pressure
PN 100, Class 600, 63K
Medium temperature range
Standard: –50 to +150 °C (–58 to +302 °F)
Option: –50 to +205 °C (–58 to +401 °F)
Ambient temperature range
–40 to +60 °C (–40 to +140 °F)
Sensor housing material
1.4301/1.4307 (304L), corrosion resistant
Transmitter housing material
AlSi10Mg, coated, 1.4404 (316L)
Degree of protection
IP66/67, type 4X enclosure
6 Endress+Hauser
Proline Promass F 200 / 8F2B
Gas Display/Operation
4‐line backlit display with touch control
(operation from outside)
Configuration via local display and operating tools possible
Remote display available
Outputs
4‐20 mA HART (passive)
4‐20 mA (passive)
Pulse/frequency/switch output (passive)
Inputs
None
Digital communication
HART, PROFIBUS PA, FOUNDATION Fieldbus
Power supply
DC 18 to 35 V (4‐20 mA HART with/without
pulse/frequency/switch)
DC 18 to 30 V (20 mA HART, 4‐20 mA)
DC 9 to 32 V (PROFIBUS PA)
Hazardous area approvals
ATEX, IECEx, cCSAus, INMETRO, NEPSI, JPN, UK Ex
Product safety
CE, C-Tick, EAC marking
Functional safety
Functional safety according to IEC 61508, applicable in safety-relevant
applications in accordance with IEC 61511
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC
17025)
Heartbeat Technology complies with the requirements for measurement
traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD
attestation)
7 Endress+Hauser
Proline Promass F 200 / 8F2B
Gas Pressure approvals and certificates
PED, CRN, AD 2000
Material certificates
3.1 material
NACE MR0175/MR0103, PMI; welding test acc. to EN ISO, ASME,
NORSOK
Hygienic approvals and certificates
3-A, EHEDG, cGMP
Density/Concentration Measuring principle
Coriolis
Product headline
Robust flowmeter with genuine loop-powered technology.
Highest measurement performance for liquids and gases in a wide range
of applications.
Sensor features
Highest process safety – immune to fluctuating and harsh environments.
Fewer process measuring points – multivariable measurement (flow,
density, temperature). Space‐saving installation – no in-/outlet run
needs.
Mass flow: measured error ±0.1 %. Medium temperature up to +205 °C
(+401 °F). Nominal diameter: DN 8 to 80 (³⁄₈ to 3").
Transmitter features
Convenient device wiring – separate connection compartment. Safe
operation – no need to open the device due to display with touch control,
background lighting. Integrated verification – Heartbeat Technology.
Loop-powered technology. Robust dual-compartment housing. Plant
safety: worldwide approvals (SIL, Haz. area).
Nominal diameter range
DN 8 to 80 (⅜ to 3")
8 Endress+Hauser
Proline Promass F 200 / 8F2B
Density/Concentration Wetted materials
Measuring tube: 1.4539 (904L); 1.4404; Alloy C22, 2.4602 (UNS
N06022)
Connection: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022)
Measured variables
Mass flow, density, temperature, volume flow, corrected volume flow,
reference density
Max. measurement error
Mass flow (liquid): ±0.1 %
Volume flow (liquid): ±0.1 %
Mass flow (gas): ±0.25 % Density (liquid): ±0.0005 g/cm³
Measuring range
0 to 70 000 kg/h (0 to 2570 lb/min)
Max. process pressure
PN 100, Class 600, 63K
Medium temperature range
Standard: –50 to +150 °C (–58 to +302 °F)
Option: –50 to +205 °C (–58 to +401 °F)
Ambient temperature range
–40 to +60 °C (–40 to +140 °F)
Sensor housing material
1.4301/1.4307 (304L), corrosion resistant
Transmitter housing material
AlSi10Mg, coated, 1.4404 (316L)
Degree of protection
IP66/67, type 4X enclosure
9 Endress+Hauser
Proline Promass F 200 / 8F2B
Density/Concentration Display/Operation
4‐line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible
Remote display available
Outputs
4‐20 mA HART (passive)
4‐20 mA (passive)
Pulse/frequency/switch output (passive)
Inputs
None
Digital communication
HART, PROFIBUS PA, FOUNDATION Fieldbus
Power supply
DC 18 to 35 V (4‐20 mA HART with/without pulse/frequency/switch)
DC 18 to 30 V (20 mA HART, 4‐20 mA)
DC 9 to 32 V (PROFIBUS PA)
Hazardous area approvals
ATEX, IECEx, cCSAus, INMETRO, NEPSI, JPN, UK Ex
Product safety
CE, C-TICK
Functional safety
Functional safety according to IEC 61508, applicable in safety-relevant
applications in accordance with IEC 61511
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC
17025)
Heartbeat Technology complies with the requirements for measurement
traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD
attestation)
10 Endress+Hauser
Proline Promass F 200 / 8F2B
Density/Concentration Pressure approvals and certificates
PED, CRN, AD 2000
Material certificates
3.1 material
NACE MR0175/MR0103, PMI; welding test acc. to EN ISO, ASME,
NORSOK
Hygienic approvals and certificates
3-A, EHEDG, cGMP
Mais informações www.br.endress.com/8F2B
Endress+Hauser Controle e addresses.endress.com
Automação Ltda.
[email protected]Brasil