Pore-Water Pressure Sensor - Piezometer
Art.-No. 69.22.
Type PP3 SS
This kind of piezometer has a filter made of sintered metal at
front face. The piezoresistive piezometer is used to monitor
pore-water pressures.
The pressure sensor of the standard piezometer is encapsulated
in a waterproof housing with a diameter of 30 mm and a length
of 160 mm. The piezometer converts pore-water pressure to an
output signal proportional to the measured value via a filter and
via the diaphragm of the pressure sensor.
TECHNICAL DATA
Filter General Specifications
Sinter metal filter (PP3 SS) for installation Dimensions, Ø / length: 30x160 mm
in sand fills resp. groundwater measuring Material: V4A 1.4571
points Weight: 450 g
Protection class: IP 68
Accessories
Push-in sleeve for Type PP4 RS E General Specifications
Cable type PUD (blue)
type PEHD standard (black) and Filter type: Sintered metal
type PEHD with ventilation tube (black) Filter area: 5.5 cm2
Overvoltage protection Density: 4.9-5.3 g/cm3
Porosity: 33-38 %
Specific flow coefficient: 3 [m2]x10-12 (laminar)
8 [m2]x10-7 (turbulent)
Porometer, Ø pore size: 6 µm
Stand 12.05.2015/ P_69.22_Porenwasserdruckgeber_PP3SS_en.pdf
Technical data/ variants
Pore water pressure sensors
AU AI VW
69.xx.01 69.xx.02 69.xx.03
AU PIEZORESISTIVE PRESSURE SENSOR, AI PIEZORESISTIVE PRESSURE SENSOR PRESSURE SENSOR WITH VW VIBRATING
4-CONDUCTOR SYSTEM WITH A BUILT-IN AMPLIFIER WIRE TECHNOLOGY
Supply Constant current 1 mA Supply 15 to 30 V Overload protection of measuring range 50 %
Optional supply 4 mA or 10 VDC Output signal 4 – 20 mA Linearity incl. hysteresis ± 0.5 % f. s.
Output signal 0 – 250 mV Overload protection (1 – 50 bar) 50 % f. s. Linearity incl. hyster. (opt.) ± 0.1 % f. s.
Overload protection (1 – 50 bar) 50 % f. s. Linearity incl. hysteresis < 0.5 % f. s. Resolution ± 0.02 %*1 f. s.
Linearity incl. hysteresis < 0.5 % f. s. Linearity incl. hysteresis (opt.) < 0.1 % f. s. Thermal zero offset < 0.02 %/ °C*1
Linearity incl. hysteresis (opt.) < 0.1 % f. s. Operating temperature +5 to +60 °C
Thermal zero offset 0.025 mV/ °C Storage temperature (dry) -15 to +100 °C SENSOR SPECIFICATIONS
Operating temperature +5 to +80 °C Temperature coefficient < 0,01 %/ °C f. s. Temperature range -20 to +80 °C
Storage temperature (dry) -40 to +100 °C Load impedance (Us-9 V) : 20 mA Current consumption Impulse excitation
Long-term drift, temperature-dependent Initialization time after switch-on 6 seconds Operating frequency 2 kHz - 3,3 kHz
(at 0 °C to 50 °C), typ. 0.25 mV With optional AD 590 temperature sensor, Supply, impulse triggering 60 V
Max. cable lenghts 500 - 1000 m* output signal 1 μA/K Optional ex-protection*2 EEx ib IIB T4
Max. cable length 1000 - 2000 m* EEx ib IIB BTI
Max. cable length 2500 m
*Dependent on the number of sensors and cabe length
*1 Deviation during operation at high temperatures on request
*2 The cable characteristics need to be taken into account for
ex-versions
Pressure and measuring ranges Pressure and measuring ranges Pressure and measuring ranges
0 - 0.1, 0 - 0.2, 0 - 0.5 , 0 - 0.5 , 0 - 1 , 0 - 2, 0 - 0.1, 0 - 0.2, 0 - 0.5 , 0 - 0.5 , 0 - 1 , 0 - 2, -0.5 to +0.4, +0.7, +1.7, +3.5, +5.0, +7.0,
0 - 5 , 0 - 10, 0 - 20, 0 - 50, 0 - 100, 0 - 200 0 - 5 , 0 - 10, 0 - 20, 0 - 50, 0 - 100, 0 - 200 +10, +20, +35, +70, +100, +200, +350, +500
and 0 - 400 bar and 0 - 400 bar and 750 bar, negative pressures standard up
to -0.5 bar
Add-ons and finishes Measurement device and
Data logging
Resistance to seawater and brackish water
1.4439 or similar Handheld measuring device HMG
Handheld measuring device for
vibrating wire transducer
Environmental protection: Gel pad to DL Data logger
protect the membrane against aggressive Measurement system MCC
chemicals and extreme pH values
Climate tested: If required, we can prepare
a temperature test for your batch or indivi-
dual sensor to provide a precise tempera-
ture quotient for your evaluation.
* PW4 RF only: With additional M36x1.5
union for press-in sleeve
All of our sensors are calibrated in defined
environmental parameters. This calibration
result is included with the actual device in
the form of a comprehensive calibration
sheet. More extensive calibrations can be
arranged at any time.
Gesellschaft für Baumesstechnik mbH