100% found this document useful (1 vote)
201 views2 pages

Installation Instructions N-1602

This document provides wiring connection instructions for a brushless alternator and regulator for dual or single voltage applications. For dual voltage applications, the regulator has connections for 28V, 14V, AC, and ignition terminals. For single voltage 28V applications, only the 28V and ignition terminals are used. The document also shows how to connect the positive and negative cables from the alternator to the vehicle battery and chassis ground. Proper torque specifications are listed for all electrical connections.

Uploaded by

alex maltez
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
201 views2 pages

Installation Instructions N-1602

This document provides wiring connection instructions for a brushless alternator and regulator for dual or single voltage applications. For dual voltage applications, the regulator has connections for 28V, 14V, AC, and ignition terminals. For single voltage 28V applications, only the 28V and ignition terminals are used. The document also shows how to connect the positive and negative cables from the alternator to the vehicle battery and chassis ground. Proper torque specifications are listed for all electrical connections.

Uploaded by

alex maltez
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

N1602-1 Alternator / N3118 Regulator

C. E. Niehoff & Co. OEM Wiring Connections


BRUSHLESS ALTERNATORS Dual or Single Voltage
Installation Instructions

DUAL VOLTAGE (28 V/14 V) applications


(see other side for single voltage):
1. Connect as shown on this page. Boots (2)

Locknut, #10-24;


torque to 2.3 Nm / 20 lb.in. Locknut, 0.2500-20;
Washer
➛ ➛
➛ torque to 4 Nm / 35 lb.in.
➛ Washer
Regulator - AC terminal ➛ Regulator - IGN terminal


Regulator



Boot


➛ connectors

Vehicle

harness Regulator - 14 V terminal
Washer
Nut, 0.3125-18 UNC-2B;
torque to 5.6 Nm / 50 lb.in.

Figure 1- N1602-1 Alternator Figure 1a - N3118 Regulator Wiring Connections

B+ connections on alternator
Bolt, 0.3750-16 UNC-2A; torque to 20 Nm / 15 lb.ft. when securing B+ cables. Both positive
cables must be connected together at battery positive potential when alternator is installed
in vehicle and during operation. Interconnect cable is part of vehicle cabling.
➛ ➛
Interconnect Lockwasher
Lockwasher ➛ cable

➛ Washer
Washer
➛ ➛
Positive cable from vehicle
Positive cable

from vehicle ➛ Secure alternator mounting
lug to vehicle using hard-

ware specified by vehicle

manufacturer and torque


B– connections on alternator
B+ output terminals sufficient to withstand weight
Bolt, 0.3125-18 UNC-2A; torque to 9

of alternator.
Nm / 80 lb. in. when securing B–
cables. Both ground cables must be

MS21245-L12 nut;
connected to vehicle’s common ➛ torque to 163 Nm/
ground when alternator is installed in 120 lb. ft. when

vehicle and during installing drive pulley.


operation.
Washer
Lock Washer Secure alternator mounting

lugs to vehicle using hard-


Washer

➛ ➛ ➛ ware specified by vehicle


manufacturer and torque

Vehicle
harness sufficient to withstand weight
of alternator.

Figure 1b - B+ and B– Terminal Connections


Page 1 of 2 II0059A
SINGLE VOLTAGE (28 V) applications
(see other side for dual voltage):
1. Connect as shown on this page. Boots (2)

Locknut, #10-24;


torque to 2.3 Nm / 20 lb.in. Locknut, 0.2500-20;
Washer
➛ ➛
➛ torque to 4 Nm / 35 lb.in.
➛ Washer
Regulator - AC terminal ➛ Regulator - IGN terminal


Regulator



➛ connectors


Washer Regulator - 14 V terminal

Nut, 0.3125-18 UNC-2B;


torque to 5.6 Nm / 50 lb.in.

Figure 2- N1602-1 Alternator Figure 2a - N3118 Regulator Wiring Connections

B+ connections on alternator
Bolt, 0.3750-16 UNC-2A; torque to 20 Nm / 15 lb.ft. when securing B+ cables. Both positive
cables must be connected together at battery positive potential when alternator is installed
in vehicle and during operation. Interconnect cable is part of vehicle cabling.
➛ ➛
Interconnect Lockwasher
Lockwasher ➛ cable

➛ Washer
Washer
➛ ➛
Positive cable from vehicle
Positive cable

from vehicle ➛ Secure alternator mounting
lug to vehicle using hard-

ware specified by vehicle

manufacturer and torque


B– connections on alternator
B+ output terminals sufficient to withstand weight
Bolt, 0.3125-18 UNC-2A; torque to 9

of alternator.
Nm / 80 lb. in. when securing B–
cables. Both ground cables must be

MS21245-L12 nut;
connected to vehicle’s common ➛ torque to 163 Nm/
ground when alternator is installed in 120 lb. ft. when

vehicle and during installing drive pulley.


operation.
Washer
Lock Washer Secure alternator mounting

lugs to vehicle using hard-


Washer

➛ ➛ ➛ ware specified by vehicle


manufacturer and torque

Vehicle
harness sufficient to withstand weight
of alternator.

Figure 2b - B+ and B– Terminal Connections

C. E. Niehoff & Co. • 2021 Lee Street • Evanston, IL 60202 Tech Services Hotline 800-643-4633

Page 2 of 2 II0059A