0% found this document useful (0 votes)
33 views1 page

TC0002

This certificate confirms that a FP15 Pilot product with a specific serial number has been tested and meets the stated settings. The equipment was tested using water glycol as the test medium for the valve and pilot. The leakage rate was less than 4.0 ml/hr for mineral oil and 8.0 ml/hr for water-based fluid. The certificate provides the working pressure, valve proof pressure, pilot proof pressure, minimum pilot pressure at 100 bar, and minimum pilot pressure at working pressure for various product codes.

Uploaded by

Mohamed Rady
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
33 views1 page

TC0002

This certificate confirms that a FP15 Pilot product with a specific serial number has been tested and meets the stated settings. The equipment was tested using water glycol as the test medium for the valve and pilot. The leakage rate was less than 4.0 ml/hr for mineral oil and 8.0 ml/hr for water-based fluid. The certificate provides the working pressure, valve proof pressure, pilot proof pressure, minimum pilot pressure at 100 bar, and minimum pilot pressure at working pressure for various product codes.

Uploaded by

Mohamed Rady
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

TC0002

Test Certificate: FP15 Pilot


BIFOLD ORDER NUMBER :
CLIENT :
CLIENT ORDER NUMBER :
KIT NO. :
PRODUCT :
QTY :
SERIAL NUMBER :

DATE :

This certificates the above equipment has been tested and conforms to those settings as stated below.
Test Medium Valve : Water Glycol (unless otherwise stated)
Test Medium Pilot : Water Glycol (H) / Compressed Air (L) (unless otherwise stated)
Proof Pressure Pilot : See Table
Proof Pressure Valve : See Table
Leakage Rate per stage @ 100 bar and x : <4.0 ml/hr mineral oil
: <8.0 ml/hr water based fluid
Minimum Pilot Pressure at 100 bar : See Table
Minimum Pilot Pressure at working pressure : See Table
Function Check valve : 20 cycles

Working Pilot Proof


Pressure (x) Valve Proof Pressure (bar) Min Pilot @ 100 Min Pilot @ WP
Code (bar) Pressure (bar) (Waived for L series) bar (bar) (bar)
L1 414 621 15 2.75 7.7
L1A 690 1035 29 3.5 16
L2 690 1035 15 1.8 7.0
L3 690 1035 10.5 1 4.5
L4 414 621 10.5 2.5 6.5
L5 690 1035 10.5 1.5 5.9
L9 900 1350 15 2 6.5
L10 1035 1553 15 2 6.5
L11 690 1035 15 1.4 4.2
H1 690 1035 360 35 170
H1A 690 1035 518 88 345
H2 690 1035 1035 80 450
H3 1035 1553 621 38 190
H5 1035 1553 1035 50 340

Signed: