Al-Burjesia, Basra-Iraq
+9647703178132
+9647823386633
http://www.ras-iq.com
[email protected]
CERTIFICATE OF THOROUGH EXAMINATION
This report complies with the Lifting Operation and Lifting Equipment Regulations
Certificate Page: 1 Of 5
Date of Through Examination: 09/07/2023 Date of Report: 10/07/2023 Report Number: RAS-A-23073030
Description and identification of the equipment: Manufacturer: TADANO FAUN
Year of Manufacture: 2007
Mobile Crane, Diesel powered, Hydraulic Operated, Model: ATF 100-4
Telescoping Boom Serial Number: 4070075
Chassis Number: WFN4RTAN1V4081082
Name and address of employer for whom the thorough examination
Plate Number: H 66789 Baghdad
was made:
Dar Al-Qrar Company Main Hoist Wire Diameter: 19(mm) Boom Length (Max-Min)
Address of premises at which the examination was made: 11.2 – 42.1 (Meter)
Basra Refinery Upgrade Project Safe Working Load (SWL):
Main Hoist Capacity: 60 (Ton) 100 Ton with fully
extended outriggers
EXAMINED IN ACCORDING TO BS EN 7121-2-3
Description Details of Load Test @4 Falls Boom Length(m) Radius (m) SWL (Kg) Proof Load (Kg)
Load test at 100 % SWL (Min.radius) 18.9 2.3 18400 NIL
Load test at 100 % SWL (Intermediate radius) 34.4 10.0 16000 17600
Load test at 100 % SWL (Max.radius) 42.1 18.0 7300 7300
Was the examination carried out:
Is this the first examination after installation or
assembly at a new site or location?
YES NO Within an interval of 6 months? YES NO
Within an interval of 12 months? YES NO
In accordance with an
If the answer to the above question is YES,
YES NO examination scheme?
YES NO
has the equipment been installed correctly? After the occurrence of
exceptional circumstances?
YES NO
Particulars of any repair, renewal or alteration required to remedy the defect identified above: NONE
Is the above a defect which is of immediate danger to persons YES NO
Is the above a defect which is not yet but could become a danger to persons: (if YES state the date by when) NONE Yes by:
Identification of any part found to have a defect which is or could become a danger to persons and a description of the defect: NONE
Particulars of any test carried out as part of examination:
The Equipment Has Been Function Tested as Per BS 7121-2-1 & BS 7121-2-3:2012 And MPI has Been Done to the Hook According to ASTME 709
IS THIS EQUIPMENT SAFE TO OPERATE? YES NO
Name & Qualifications of person making this Name of person authenticating this report: Latest date by which next thorough
report: Signature: Ammar Khaled examination must be carried out:
Aws Abdulla 08/07/2024
Name and address of employer of person making and authenticating this report:
Hussein Ali Hussein, Basra, Burjesia
Al-Burjesia, Basra-Iraq
شركة راية الشرق
+9647703178132
+9647823386633
للتجارة واملقاوالت العامة والنقل العام والفحص الهندس ي املحدودة
Al-Burjesia, Basra-Iraq
+9647703178132
+9647823386633
http://www.ras-iq.com
[email protected]
CERTIFICATE OF THOROUGH EXAMINATION
This report complies with the Lifting Operation and Lifting Equipment Regulations
Report Number: RAS-A-23073030 Certificate Page: 2 Of 5
GENERAL DESCRIPTION OF THE EQUIPMENT Status
1 – OPERATOR CAB OK NO NA Comments
Manufacturer’s operation manual
Load chart & operator competency certificate
Controls / marking & air condition
Window / wipers / chair / door look & seals
Body work
2 – Boom OK NO NA Comments
Head section / root section / intermediate sections
Jib, boom, turret, boom extension
Joining pins or bolts
Foot pins & bushes
Sheaves, pins & structures
Chords
Lights
3 – SAFE LOAD INDICATOR OK NO NA Comments
Load indicator
Radius indicator
Angle
Audible warning
Visible warning
4 – CHASSIS OK NO NA Comments
Structural member / welding
Security of fastening
Electrical wiring / pipe work / body work
Level indicator / main block traveling connection
point
Lights
5 – WHEELS OK NO NA Comments
Tier walls
Wheel nut security
Tier pressure
Thread
Rims
Bearings
Al-Burjesia, Basra-Iraq
شركة راية الشرق
+9647703178132
+9647823386633
للتجارة واملقاوالت العامة والنقل العام والفحص الهندس ي املحدودة
Al-Burjesia, Basra-Iraq
+9647703178132
+9647823386633
http://www.ras-iq.com
[email protected]
CERTIFICATE OF THOROUGH EXAMINATION
This report complies with the Lifting Operation and Lifting Equipment Regulations
Report Number: RAS-A-23073030 Certificate Page: 3 Of 5
6 – OUTRIGGERS OK NO NA Comments
Locking mechanism
Retraction / Travel alarm No Travel Alarm
Foot pads / Hydraulic hoses and fittings
Seals
7 - SLEWRING OK NO NA Comments
Brake / rocking motions / Bolts
Lubrication
Gear teeth on slew ring and pinion
Clutch
8 – COUNTERWEIGHTS OK NO NA Comments
Security / Connection / Hydraulics / Rams
Hoses
Fittings
9 – MAIN BLOCK / WHIP LINE OK NO NA Comments
Hook / Safety catch
Sheaves / Structure / Pins
Whip line Capacity
Main block Capacity
10 - WINCHES OK NO NA Comments
Drum
Rope anchor
Spooling
Brake
Rope guards
Clutches
11 - WIRE ROPE OK NO NA Comments
Main hoist wire rope
Termination
Boom wire rope
Wedge socket
Whip line wire rope
12 – SAFTEY DEVICES OK NO NA Comments
Level indicator or Spirit level
Load limiter
Limit stops relating to lifting motions
Al-Burjesia, Basra-Iraq
شركة راية الشرق
+9647703178132
+9647823386633
للتجارة واملقاوالت العامة والنقل العام والفحص الهندس ي املحدودة
Al-Burjesia, Basra-Iraq
+9647703178132
+9647823386633
http://www.ras-iq.com
[email protected]
CERTIFICATE OF THOROUGH EXAMINATION
This report complies with the Lifting Operation and Lifting Equipment Regulations
Report Number: RAS-A-23073030 Certificate Page: 4 Of 5
Al-Burjesia, Basra-Iraq
شركة راية الشرق
+9647703178132
+9647823386633
للتجارة واملقاوالت العامة والنقل العام والفحص الهندس ي املحدودة
Al-Burjesia, Basra-Iraq
+9647703178132
+9647823386633
http://www.ras-iq.com
[email protected]
CERTIFICATE OF THOROUGH EXAMINATION
This report complies with the Lifting Operation and Lifting Equipment Regulations
Report Number: RAS-A-23073030 Certificate Page: 5 Of 5
LOAD TEST & NDT (MPI) REPORT
Report No: 23073030 Examination Date: 09/07/2023
LOAD TEST
Equipment Details
Load Cell Serial No: 30682 / 25532 Vernier Caliper S/N: 400 0576 010 Measuring Tape S/N: N/A
NDT (MPI) FOR CRANE’S HOOK
NDT Details
Standard: ASTME 709 Equipment type: PERMENANT YOKE Contrast Media: WHITE CONTRAST
Viewing Condition Colored media Method WET Indicator: BLACK INK
NDT Equipment Details
YOKE S/N A12-512 WHITE CONTRAST MagnavisWCP-2 BLACK INK Magnavis7HF
Hook Details
Main Hook Serial Number: 99707004453
Main Hook SWL: 60 Ton
NDT Procedure
Visual &MPI CARRIED OUT FOR THE ABOVE DESCRIPTION AND FOUND FREE OF SURFACE DEFECTS AT THE TIME OF INSPECTION
Identification of any part found to have a defect and a description of the defect: NONE
Particulars of any repair, renewal or alteration required to remedy the defect identified above: NONE
ASNT Level II Inspector Name & Signature: Hussein Ali RESULT: PASS
Al-Burjesia, Basra-Iraq
شركة راية الشرق
+9647703178132
+9647823386633
للتجارة واملقاوالت العامة والنقل العام والفحص الهندس ي املحدودة