0% found this document useful (0 votes)
125 views5 pages

Certificate of Thorough Examination: Examined in According To Bs en 7121-2-3

The document is a 5 page certificate of thorough examination for a mobile crane. It details inspection of the crane and found it to be in good working order with no defects. The next examination must be completed by August 2024.

Uploaded by

3 face
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
125 views5 pages

Certificate of Thorough Examination: Examined in According To Bs en 7121-2-3

The document is a 5 page certificate of thorough examination for a mobile crane. It details inspection of the crane and found it to be in good working order with no defects. The next examination must be completed by August 2024.

Uploaded by

3 face
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 5

Al-Burjesia, Basra-Iraq

+9647703178132

+9647823386633

http://www.ras-iq.com

[email protected]

CERTIFICATE OF THOROUGH EXAMINATION


This report complies with the Lifting Operation and Lifting Equipment Regulations
Certificate Page: 1 Of 5
Date of Through Examination: 09/07/2023 Date of Report: 10/07/2023 Report Number: RAS-A-23073030

Description and identification of the equipment: Manufacturer: TADANO FAUN


Year of Manufacture: 2007
Mobile Crane, Diesel powered, Hydraulic Operated, Model: ATF 100-4
Telescoping Boom Serial Number: 4070075
Chassis Number: WFN4RTAN1V4081082
Name and address of employer for whom the thorough examination
Plate Number: H 66789 Baghdad
was made:
Dar Al-Qrar Company Main Hoist Wire Diameter: 19(mm) Boom Length (Max-Min)
Address of premises at which the examination was made: 11.2 – 42.1 (Meter)
Basra Refinery Upgrade Project Safe Working Load (SWL):
Main Hoist Capacity: 60 (Ton) 100 Ton with fully
extended outriggers

EXAMINED IN ACCORDING TO BS EN 7121-2-3


Description Details of Load Test @4 Falls Boom Length(m) Radius (m) SWL (Kg) Proof Load (Kg)
Load test at 100 % SWL (Min.radius) 18.9 2.3 18400 NIL
Load test at 100 % SWL (Intermediate radius) 34.4 10.0 16000 17600
Load test at 100 % SWL (Max.radius) 42.1 18.0 7300 7300
Was the examination carried out:
Is this the first examination after installation or
assembly at a new site or location?
YES NO  Within an interval of 6 months? YES NO 
Within an interval of 12 months? YES  NO
In accordance with an
If the answer to the above question is YES,
YES NO examination scheme?
YES NO 
has the equipment been installed correctly? After the occurrence of
exceptional circumstances?
YES NO 
Particulars of any repair, renewal or alteration required to remedy the defect identified above: NONE

Is the above a defect which is of immediate danger to persons YES NO 


Is the above a defect which is not yet but could become a danger to persons: (if YES state the date by when) NONE Yes by:

Identification of any part found to have a defect which is or could become a danger to persons and a description of the defect: NONE
Particulars of any test carried out as part of examination:
The Equipment Has Been Function Tested as Per BS 7121-2-1 & BS 7121-2-3:2012 And MPI has Been Done to the Hook According to ASTME 709

IS THIS EQUIPMENT SAFE TO OPERATE? YES  NO


Name & Qualifications of person making this Name of person authenticating this report: Latest date by which next thorough
report: Signature: Ammar Khaled examination must be carried out:
Aws Abdulla 08/07/2024

Name and address of employer of person making and authenticating this report:
Hussein Ali Hussein, Basra, Burjesia

Al-Burjesia, Basra-Iraq
‫شركة راية الشرق‬
+9647703178132
+9647823386633
‫للتجارة واملقاوالت العامة والنقل العام والفحص الهندس ي املحدودة‬
Al-Burjesia, Basra-Iraq

+9647703178132

+9647823386633

http://www.ras-iq.com

[email protected]

CERTIFICATE OF THOROUGH EXAMINATION


This report complies with the Lifting Operation and Lifting Equipment Regulations

Report Number: RAS-A-23073030 Certificate Page: 2 Of 5


GENERAL DESCRIPTION OF THE EQUIPMENT Status
1 – OPERATOR CAB OK NO NA Comments
Manufacturer’s operation manual 
Load chart & operator competency certificate 
Controls / marking & air condition 
Window / wipers / chair / door look & seals 
Body work 
2 – Boom OK NO NA Comments
Head section / root section / intermediate sections 
Jib, boom, turret, boom extension 
Joining pins or bolts 
Foot pins & bushes 
Sheaves, pins & structures 
Chords 
Lights 
3 – SAFE LOAD INDICATOR OK NO NA Comments
Load indicator 
Radius indicator 
Angle 
Audible warning 
Visible warning 
4 – CHASSIS OK NO NA Comments
Structural member / welding 
Security of fastening 
Electrical wiring / pipe work / body work 
Level indicator / main block traveling connection

point
Lights 
5 – WHEELS OK NO NA Comments
Tier walls 
Wheel nut security 
Tier pressure 
Thread 
Rims 
Bearings 

Al-Burjesia, Basra-Iraq
‫شركة راية الشرق‬
+9647703178132
+9647823386633
‫للتجارة واملقاوالت العامة والنقل العام والفحص الهندس ي املحدودة‬
Al-Burjesia, Basra-Iraq

+9647703178132

+9647823386633

http://www.ras-iq.com

[email protected]

CERTIFICATE OF THOROUGH EXAMINATION


This report complies with the Lifting Operation and Lifting Equipment Regulations
Report Number: RAS-A-23073030 Certificate Page: 3 Of 5
6 – OUTRIGGERS OK NO NA Comments
Locking mechanism 
Retraction / Travel alarm  No Travel Alarm
Foot pads / Hydraulic hoses and fittings 
Seals 
7 - SLEWRING OK NO NA Comments
Brake / rocking motions / Bolts 
Lubrication 
Gear teeth on slew ring and pinion 
Clutch 
8 – COUNTERWEIGHTS OK NO NA Comments
Security / Connection / Hydraulics / Rams 
Hoses 
Fittings 
9 – MAIN BLOCK / WHIP LINE OK NO NA Comments
Hook / Safety catch 
Sheaves / Structure / Pins 
Whip line Capacity 
Main block Capacity 
10 - WINCHES OK NO NA Comments
Drum 
Rope anchor 
Spooling 
Brake 
Rope guards 
Clutches 
11 - WIRE ROPE OK NO NA Comments
Main hoist wire rope 
Termination 
Boom wire rope 
Wedge socket 
Whip line wire rope 
12 – SAFTEY DEVICES OK NO NA Comments
Level indicator or Spirit level 
Load limiter 
Limit stops relating to lifting motions 

Al-Burjesia, Basra-Iraq
‫شركة راية الشرق‬
+9647703178132
+9647823386633
‫للتجارة واملقاوالت العامة والنقل العام والفحص الهندس ي املحدودة‬
Al-Burjesia, Basra-Iraq

+9647703178132

+9647823386633

http://www.ras-iq.com

[email protected]

CERTIFICATE OF THOROUGH EXAMINATION


This report complies with the Lifting Operation and Lifting Equipment Regulations
Report Number: RAS-A-23073030 Certificate Page: 4 Of 5

Al-Burjesia, Basra-Iraq
‫شركة راية الشرق‬
+9647703178132
+9647823386633
‫للتجارة واملقاوالت العامة والنقل العام والفحص الهندس ي املحدودة‬
Al-Burjesia, Basra-Iraq

+9647703178132

+9647823386633

http://www.ras-iq.com

[email protected]

CERTIFICATE OF THOROUGH EXAMINATION


This report complies with the Lifting Operation and Lifting Equipment Regulations

Report Number: RAS-A-23073030 Certificate Page: 5 Of 5

LOAD TEST & NDT (MPI) REPORT


Report No: 23073030 Examination Date: 09/07/2023
LOAD TEST
Equipment Details
Load Cell Serial No: 30682 / 25532 Vernier Caliper S/N: 400 0576 010 Measuring Tape S/N: N/A

NDT (MPI) FOR CRANE’S HOOK


NDT Details
Standard: ASTME 709 Equipment type: PERMENANT YOKE Contrast Media: WHITE CONTRAST
Viewing Condition Colored media Method WET Indicator: BLACK INK
NDT Equipment Details
YOKE S/N A12-512 WHITE CONTRAST MagnavisWCP-2 BLACK INK Magnavis7HF

Hook Details
Main Hook Serial Number: 99707004453

Main Hook SWL: 60 Ton

NDT Procedure
Visual &MPI CARRIED OUT FOR THE ABOVE DESCRIPTION AND FOUND FREE OF SURFACE DEFECTS AT THE TIME OF INSPECTION

Identification of any part found to have a defect and a description of the defect: NONE

Particulars of any repair, renewal or alteration required to remedy the defect identified above: NONE

ASNT Level II Inspector Name & Signature: Hussein Ali RESULT: PASS