0% found this document useful (0 votes)
154 views8 pages

3 - Proportional Pressure Reducing Valve

This document provides information on a proportional pressure reducing valve including: - It is a direct operated cartridge valve that reduces system pressure proportionally to solenoid current. - It functions independently of input pressure and sets minimum pressure with 0 current or power failure. - It can be used to continuously reduce system pressure and control couplings, pumps, and directional valves.

Uploaded by

Adel Ashraf
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
154 views8 pages

3 - Proportional Pressure Reducing Valve

This document provides information on a proportional pressure reducing valve including: - It is a direct operated cartridge valve that reduces system pressure proportionally to solenoid current. - It functions independently of input pressure and sets minimum pressure with 0 current or power failure. - It can be used to continuously reduce system pressure and control couplings, pumps, and directional valves.

Uploaded by

Adel Ashraf
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 8

Proportional pressure reducing RE 64666/02.

10 1/8

valve, direct operated

Type MHDRE 04 K

Size 4
Component series 1X
Maximum control pressure 30 bar
Maximum flow 6 l/min
H7660

Table of contents Features


Content Page – Direct operated proportional pressure reducing valve for
Features 1 reducing a system pressure
Ordering code 2 – Cartridge valve
Standard types 2 – Suitable for mobile and industrial applications
Symbol 2 – Operation by means of proportional solenoid
Function, section 3 – In case of power failure, the minimum pressure is set
Technical data 4, 5 – Recommended control electronics:
• Mobile amplifier type RA and RC
Characteristic curves with tolerance band 5
Admissible working range 6
Unit dimensions, mounting cavity 7
Available individual components 8

Information on available spare parts:


www.boschrexroth.com/spc
2/8 Bosch Rexroth AG Hydraulics MHDRE 04 RE 64666/02.10

Ordering code

MHDRE 04 K 1X 30 A V *

Proportional pressure reducing Further details in the plain text


valve, direct operated Seal material
Size 4 = 04 V= FKM seals
Cartridge valve =K (other seals upon request)
Component series 10 to 19 = 1X Attention!
(10 to 19: Unchanged installation and connection dimensions) Observe compatibility of seals with
hydraulic fluid used!
Maximum control pressure 30 bar = 30
Electrical connection 1)
Proportional solenoid, wet-pin =A
K40 = without mating connector with
connector DT 04-2P (Deutsch plug)
Nominal voltage
1) Mating connectors (order separately) see data sheet 08006 G12 = DC 12 V
G24 = DC 24 V

Standard types

Material number
Type 12 V 24 V
MHDRE 04 K1X/30AG..K40V R901059491 R901067641

Symbol

① = Main port 1 (A)


② = Main port 2 (P)
2 3 ③ = Main port 3 (T)
RE 64666/02.10 MHDRE 04 Hydraulics Bosch Rexroth AG 3/8

Function, section
General Basic principle
The proportional pressure reducing valve type MHDRE 04 K The valve controls the pressure in the main port ① propor-
is a direct operated cartridge valve in 3-way design. It reduc- tionally to the current at the solenoid.
es the control pressure (main port ①) proportionally to the The proportional solenoid (1) converts the electric current into
solenoid current and functions largely independently from the mechanical force that acts on the spool (2) via the armature.
input pressure (main port ②). The spool controls the connection between the main ports.
With a command value of 0 or in case of power failure, the
minimum pressure is set. Operation is effected by means of
Note!
proportional solenoid. The solenoid's interior is connected to
the main port ③ and filled with hydraulic fluid. Occurring tank pressure (main port ③) is added up to the
control pressure (main port ①).
Depending on the electric command value, these valves can
be used to reduce the system pressure continuously. The
valve is suitable for controlling couplings, pumps and direc- Attention!
tional valves as well as for use in proportional pilot controls If the valve is not installed or installed in a system that is not
(particularly in the mobile area, however also for industrial ap- completely bled, the valve must not be energized as other-
plications). wise, the entering air has a very negative effect on the valves'
dynamic behavior.

1 2

3 2

① = Main port 1 (A)


② = Main port 2 (P)
③ = Main port 3 (T)
4/8 Bosch Rexroth AG Hydraulics MHDRE 04 RE 64666/02.10

Technical Data (For applications outside these parameters, please consult us!)

general
Weight kg approx. 0.25
Installation position Any - if it is ensured that no air can collect upstream the
valve. Otherwise, we recommend suspended installation of
the valve (electric connection downwards).
Ambient temperature range °C See “admissible working range” page 6
Storage temperature range °C –30 to +80

Environmental audits:
Salt spray test according to EN ISO 9227 h 600 (NSS test)
Surface protection Solenoid Coating according to DIN 50962-Fe//ZnNi with thick lay-
er passivation

hydraulic
Maximum control pressure – Main port ① bar 30
Maximum input pressure – Main port ② bar 100
Maximum backpressure – Main port ③ bar at zero pressure (max. 30 bar, occurring tank pressures are
added up to the control pressure (main port ①))
Maximum flow (∆p = 7 bar) l/min 6
Maximum leakage – Main port ③ ml/min 100 (50 bar in ②; I = 0 mA, 46 cSt)
Maximum pilot oil ml/min 350 (50 bar in ②; I = Imax, 46 cSt)
Hydraulic fluid Mineral oil (HL, HLP) according to DIN 51524; other hy-
draulic fluids upon request
Hydraulic fluid temperature range °C –30 to +110
Viscosity range mm2/s 5 to 400
Maximum permitted degree of contamination of the hydraulic Class 20/18/15 1)
fluid - cleanliness class according to ISO 4406 (c)
Hysteresis (within tolerance band) bar ≤ 1.5
Step response (Tu + Tg) ms ≤ 60 (50 bar in ②; 46 cSt, qV = 0 l/min,
0 % → 100 %; 100 % → 0 % dead volume in ① 140 cm3)
Repeatability % < 2 % of the maximum control pressure
Load cycles 107
Mesh size strainer element at the main port ② µm 160

1) The cleanliness classes specified for the components must


be adhered to in hydraulic systems. Effective filtration pre-
vents faults and at the same time increases the service life
of the components.
For the selection of filters, see data sheets 50070, 50076,
50081, 50086, 50087 and 50088.

For more information refer to data sheets:


– 07008
– 07800
– 07900
– 64020
RE 64666/02.10 MHDRE 04 Hydraulics Bosch Rexroth AG 5/8

Technical Data (For applications outside these parameters, please consult us!)

electrical
Supply voltage V 12 DC 24 DC
Maximum control current A 1.7 0.98
Coil resistance at 20 °C Ω 3.5 11.1
Duty cycle (ED) 3) % 100
Maximum coil temperature 4) °C 185
Protection class according to VDE 0470-1 (DIN EN 60529), IP 69K (with mating connector mounted and locked)
DIN 40050-9
Chopper frequency (recommended) 5) Hz 200
Control electronics (separate order) Control unit RA, see data sheet 95230
Control units RC, see data sheet 95200
Design according to VDE 0580

3) In
case of use at an altitude of more than 2000 m a.s.l., we Note!
recommend consulting the manufacturer.
– The technical data were determined at a viscosity of
4) Due to the temperatures occurring at the surfaces of the ν = 46 mm²/s (HLP46; 40 °C).
solenoid coils, the standards ISO 13732-1 and EN 982
– You can find more information on the correct use of hydrau-
need to be adhered to!
lic products of Rexroth in the data sheet 64020-B, “Hydrau-
5) The chopper frequency is to be optimized depending on the lic valves for mobile applications - General information”.
application. In this regard, observe the temperature range
of the application.

Characteristic curves with tolerance band (measured with HLPD46, ϑoil = 50 ± 5 °C)

34 Measuring conditions:
32
Installation position: horizontal
30
Amplifier: Analog amplifier
Set pressure at the main port ① in bar →

28
RA (data
26 sheet 95230)
24 Chopper frequency: 200 Hz
22
Input pressure: 50 bar
20
Dead volume at the 135 ml
18 main port ①:
16
14
12
10
8
6
4
2

0 0,2 0,4 0,6 0,8 1 1,2 1,4 1,6 1,8 2


12 V (0,6) (1,7)

24 V 0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 0,98
Control current in A →
6/8 Bosch Rexroth AG Hydraulics MHDRE 04 RE 64666/02.10

Admissible working range:

Admissible working range against the ambient temperature


Version “G12” (DC 12 V)
12 120

(3) Admissible continuous application of current


(1) Required minimum voltage at the coil in V →

11 1,7

(2) Relative duty cycle ED for Imax (1.7 A)


3
10 110
9 1,6

in A with 100 % ED →
8 100
2
7
1,5

in % →
1
6 90
5
1,4
4 80
3
2 70 1,3

1
0 60 1,2
-30 -20 -10 0 10 20 30 40 50 60 70 80 90 100 110

Ambient temperature in °C →

Admissible working range against the ambient temperature


Version “G24” (DC 24 V)
24 120 1

(3) Admissible continuous application of current


(1) Required minimum voltage at the coil in V →

0,98
(2) Relative duty cycle ED for Imax (0,98 A)

22
3
20 110 0,95
18
16 100 0,9 in A with 100 % ED →
2
14
in % →

1
12 90 0,85
10
8 80 0,8
6
4 70 0,75
2
0 60 0,7
-30 -20 -10 0 10 20 30 40 50 60 70 80 90 100 110
Ambient temperature in °C →
RE 64666/02.10 MHDRE 04 Hydraulics Bosch Rexroth AG 7/8

Unit dimensions, mounting cavity (dimensions in mm)


30±0,3

26,6±0,3
1

15 1
29
0,05 A 23,8+0,1
47,5±0,5 M22 x 1,5
0,05 A
5 19H8
A
45 0,02 A
15

max 0,5
2,4+0,1
3

13,1±0,1
13±0,2

+0,1
R0,1 Rz 16
1

LS
0
9,5

11

min 24,5 1)
19±0,1
3
23,5±0,3

27,5±0,1

30,8±0,1

min 40,5 1)
34±0,1
39,5±0,5

min 42
60
5±0,1

2
2
5±0,1

1
15f7
15 1 0,02 A
17±0,3
min 5
18,5-0,1
15H8
19f7
M22 x 1,5
-0,1 +0,4
28 Rz 8
31,8

1) Depth of fit
1 Mating connector for connector “K40”
(separate order, see data sheet 08006)
2 Strainer
3 Flat across widths SW30; MA = 12+5 Nm Standards:
Workpiece edges DIN ISO 13715
① = Main port 1 (A) Form and position tolerance DIN EN ISO 1101
② = Main port 2 (P) General tolerances for DIN ISO 2768-mK
③ = Main port 3 (T) metal-cutting procedures
LS = Location shoulder Tolerance DIN ISO 8015
Surface quality DIN EN ISO 1302
8/8 Bosch Rexroth AG Hydraulics MHDRE 04 RE 64666/02.10

Available individual components

999

Item Description Material no.


999 Seal kit of the valve R961004421

Bosch Rexroth AG © This document, as well as the data, specifications and other informa-
Hydraulics tion set forth in it, are the exclusive property of Bosch Rexroth AG. It
Zum Eisengießer 1 may not be reproduced or given to third parties without its consent.
97816 Lohr am Main, Germany The data specified above only serve to describe the product. No state-
Phone +49 (0) 93 52 / 18-0 ments concerning a certain condition or suitability for a certain applica-
Fax +49 (0) 93 52 / 18-23 58 tion can be derived from our information. The information given does not
[email protected] release the user from the obligation of own judgment and verification. It
www.boschrexroth.de must be remembered that our products are subject to a natural process
of wear and aging.

You might also like