0% found this document useful (0 votes)
72 views8 pages

(ACM) RG Catalogue

The High Pressure Water Mist System utilizes the latest declining pressure technology with cylinder batteries, open nozzles, and a RG W-FOG UAC system to control and protect an area. It simultaneously attacks fires from two angles, cooling and reducing oxygen levels, to effectively control fires. The system is ideal for occupied spaces and causes minimal damage due to its water efficiency and smoke removal capabilities. It uses inert nitrogen as a propellant, making it environmentally friendly.

Uploaded by

razak shareef
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
72 views8 pages

(ACM) RG Catalogue

The High Pressure Water Mist System utilizes the latest declining pressure technology with cylinder batteries, open nozzles, and a RG W-FOG UAC system to control and protect an area. It simultaneously attacks fires from two angles, cooling and reducing oxygen levels, to effectively control fires. The system is ideal for occupied spaces and causes minimal damage due to its water efficiency and smoke removal capabilities. It uses inert nitrogen as a propellant, making it environmentally friendly.

Uploaded by

razak shareef
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 8

CYLINDER BATTERY WITH

DECLINING PRESSURE
TECHNOLOGY
WATER
MIST
SYSTEM

OPEN
NOZZLES
PROTECTION

GUARANTEED
The High Pressure Water Mist Sys-
tem with cylinder battery, RG W-
FOG UAC and open nozzles, utili-
zes the latest technology to control,

protected area.

For it, it has nozzles for optimum


mist capacity manufactured with
the highest quality standards and
tested in the most prestigious inter-
national laboratories according to
the norms and guidelines establis-
hed for each application.

The RG W-FOG UAC system com-


bines two technologies in one. It
simultaneously attacks form two
-

locally reducing the concentration

and descending the temperature.


This is possible thanks to that du-

the water is produced in micro dro-

to a greater heat exchange surface,

the adjacent oxygen, hindering the


combustion.

This system is ideal for busy areas, since the displacement of the oxygen
-

maximizing its cooling capacity and reducing the pos-


sible damages to a minimum.

It is a completely ecological system that employs an


inert gas as a propellant, naturally present in the air
and that has no greenhouse effect nor damages the
ozone layer.

It is especially recommendable when there are people

Due to its harmlessness and smoke dragging capacity


and particles in suspension, the water mist cleans and

the people with complete security.

RG W-FOG UAC

Water in the determined quantity calculated.

N2 pressurizer in 1:3 proportions.


COMPONENTS

The RG W-FOG UAC system is comprised of autonomously operating cylinders which already con-
tain the necessary agent, nitrogen, for their pressurization and open nozzles, that produce the misting
and distribute the water throughout the entire affected area.

so much for the technology of constant pressure as for the technology of declining pressure. The

discharge pressure.
COMPONENTS
SPECIAL:
All the employed electric com-
ponents in this system can be
Cylinders of N2 -
substituted for electrical com-

Discharge manifold to collect the propelled


water and direct it to the network. That is to say, when the equip-
ment protects a special hazard
that has an atmosphere with
the possibility of an explosion
Network piping and accessories.
the electrical components of
our system can be substituted.

Distribution blocks and direct tees to facilitate -


installation. mospheres more or less restric-

Pressure gauges, pressure gauges with electric


agencies as ATEX, UL, CSA,
contacts, switches, etc. for the control and load
IEC Ex, KOSHA, NEPSI, etc.

Trigger hoses, discharge hoses, adaptors, etc.

Electric, manual, pneumatic, etc. discharge


headrests.

Continuous weighing systems for the water


and nitrogen cylinders.
PRINCIPLES OF

OPERATION
DETECTION:

case of electric failure exists, or to arrange redundant thermal-pneumatic detection lines, for the automatic

ACTIVATION:
-
ders, pressurizing and forcing all the water to run through the water pipes and be discharged in the protec-

DECLINING PRESSURE TECHNOLOGY:


RG Systems offers a unique protection system with High Pressure Water Mist by means of cylinder batte-
-
rizes the water cylinders and they carry out the correct water impulsion through the distribution network
to the nozzles.

THE BEST ALTERNATIVE

SET AGAINST SPRINKLERS SET AGAINST GAS SYSTEMS:


Area doesn’t need water tightness.
to the high pressure and small The advantages of
the
size of the micro droplets WATER MIST SYSTEM application.
against other traditional
PCI systems are
areas. numerous:
Minimum damage on real estate
and equipment.
Economical reloads
Compak and autonomous equipment.
BENEFITS

since it minimizes water use, using a tenth of the traditional sprinkler system. Besides, the use of inert gas

Thanks to the cooling off effect and cooling Due to its design, it permits an integration
with esthetics and the architecture in which it
is installed, obtaining a suitable and beautiful
- installation in applications as museums, hos-
ning to the normal rhythm of work sooner. pitals, schools, etc.

Eligible to protect busy areas without cau-


sing damages to the people that are found in designing systems for different applications, for

of special protections, transformers, mechani-


without danger. cal stairs, etc.

It has a particle dragging effect in decompo- Cost reduction in the resulting damages by
sition and poison gases and irritants created employing this technology, as well as a cost
- reduction when utilizing a system with less
ble for the personnel’s correct respiration that water and less necessary components than
works in the protected area. other systems.

The damage caused to the equipment, goods Direct local application on the protected area
and real estate is minimum due to the mini- -
mum water consumption. cations as transformers, turbines, etc.

Automatic operation, without use of exter- Guarantee in the use of the RG SYSTEMS ap-
nal energy since the water pressurization -
and impulsion uses an inert gas that doesn’t nal agencies, like VdS, Bureau Veritas, DNV,
damage the ozone layer and has zero green- etc. As well as in laboratories of recognized
house effect. prestige as VTT, SINTEF, etc.
ACM CONTRACTING PTE LTD
50 Gambas Crescent
#04-17 Proxima @ Gambas
Singapore 757022
Tel: (65) 6747 5423 | Fax: (65) 6747 5023
www.acmc.com.sg | [email protected]