0% found this document useful (0 votes)
255 views8 pages

SMC - Pte 100 C

The document describes the PTE-100-C, a portable unit for testing current and voltage relays up to 250A. It produces variable AC/DC current and voltage outputs and measures injected current, voltage, frequency and power. The unit allows setting injection time/value limits for safe testing. It connects to other units via BUS-PTE for expanded testing capabilities and connects to a PC for calibration and automated testing.

Uploaded by

Suliyah Kuswadi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
255 views8 pages

SMC - Pte 100 C

The document describes the PTE-100-C, a portable unit for testing current and voltage relays up to 250A. It produces variable AC/DC current and voltage outputs and measures injected current, voltage, frequency and power. The unit allows setting injection time/value limits for safe testing. It connects to other units via BUS-PTE for expanded testing capabilities and connects to a PC for calibration and automated testing.

Uploaded by

Suliyah Kuswadi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 8

catalogo PTE-100-C ingles 15/7/00 12:39 Página 2

PTE-100-C
Current and Voltage Relay
testing unit to 250A
catalogo PTE-100-C ingles 15/7/00 12:41 Página 3

PTE-100-C

CHARACTERISTICS
– Variable current output up to 250 A.
– Variable AC voltage output up to 250V.
– Variable DC voltage output up to 350V.
– Variable auxiliary DC power supply to 250V.
– Auxillary AC voltage output of 110V.
– Outputs are fully isolated and Electronically protected.
APPLICATIONS
– Timer resolution: 1 ms. – Testing of overcurrent and minimum/maximum voltage relays.
– Contains Voltmeter, ammeter, frequency meter, measures apparent – Testing of overcurrent directional relays (option PTE-FCC).
power, impedance, and internal and external phase angles. – Testing of reclosing devices (option PTE-FCE).
– Control of injection time. – Testing of dc relays.
– Control of the maximum value injected. – Testing of MCB’s.
– Current can be pre-selected. – Verification of the knee point in current transformers.
– 1,000VA for 1 minute. – Combined with the PTE-100-V, forms a complete single phase
– RS-232 Serial Port. system, capable to test diferencial, sychronized, and inverse
– PTE-BUS Port. power relays, etc.
– Dimensions: 200 x 300 x 200 mm / 13.5 kg.
8 x 12 x 8 in / 30 lb.

DESCRIPTION FEATURES
The PTE-100-C is a portable Universal test equipment for The PTE-100-C is designed in a way that enables testing of
relay tests for electromechanical, electronic, and digital protective relays in an effective and easy manner for the
relays. The equipment can output a variable current up to operator. There is a variable dc voltage output for the
250A, a variable AC Voltage up to 250V, a variable DC auxiliary voltage supply for electronic relays, which is
Voltage up to 350V. Also the unit incorporates a variable independent of the main current and voltage outputs. For
stabilized auxiliary DC Voltage supply up to 250V and a the testing of overcurrent and maximum or minimum
fixed AC Voltage output up to 110V, which can be variable voltage relays, the unit has 2 Displays that indicated the
with the PTE-FCF option. output value and trip time respectively. In the case of testing
timing characteristics (inverse, very inverse, etc) the current
The equipment is extremely compact, and value being injected can be
contains all the functions necessary for current presented in percentage of the
and voltage relays. It incorporates various
measurement functions such as a voltmeter,
ammeter, frequency meter, as well as
measures apparent power, impedance, and
internal and external phase angles. From the front
panel controls, the maximum output injection can be
limited, used for example in testing
instantaneous overcurrent relays. Injection
time can also be limited, useful to safely
test reclosing devices.

The PTE-100-C can communicate with a PC via the


serial port RS-232, and can be connected to other PTE
units via the BUS-PTE.
catalogo PTE-100-C ingles 15/7/00 12:42 Página 4

PTE-100-C and PTE-300-V


One high current and three
voltage outputs.

nominal relay current, in a way you can compare the • Impedance measurement (Ω):
results with the theoretical characteristics. When testing - Measures the impedance connected to the current
instantaneous devices the unit can be set in the maximum circuit.
current measurement mode (Imax), limiting the maximum - 4 wire measurement method.
current to be injected (Ilim), and limiting the time of • Apparent Power Measurement (VA):
injection (Tlim). The pre-selection mode (Preset) enables the
- The power consumed in the current circuit.
current value to be pre-selected, when the impedance of
- Power V x I.
the load is previously measured, thus avoiding the
preheating of relays.

INTERCONNECTION CAPABILITY
The PTE-100-C can be interconnected, with a simple
BUS-PTE cable, to any other equipment in the PTE Range
(PTE-100-V, PTE-300-V, etc).
When connected to the PTE-100-V, the combination is a
MEASUREMENT FUNCTIONS complete single-phase relay test system that can test
The PTE-100-C contains the following measurement overcurrent directional relays, differential relays, or
functions: synchronizing relays.
• Ammeter: External current measurement up to 10A can When connected to the PTE-300-V, the combination forms
be measured. a system of 3 voltage outputs and 1 current, that can test
• Voltmeter: External voltage measurement up to 400V in relays which require 3 voltages to function correctly, such
ac and dc, and with the option PTE-FCH up to 1,000V. as distance relays, and directional power relays, etc.
• Frequency meter: External frequency measurement
from 20 to 2000 Hz.
• Phase angle meter enables to measurement
of the phase angle between:
- The current produced by the PTE-100-C
and the voltage in the output taps, the
impedance angle of the load.
- The current produced by the PTE-100-C
and an external voltage.
- External current and voltage.

V
ϕ
I
catalogo PTE-100-C ingles 15/7/00 12:45 Página 5

PTE-100-C
1 SIGNAL MONITOR
1
The signal monitor indicates the state of the relay under test. These inputs can
work with Dry Contacts (voltage free) or with Voltage Signals from 5 to 250V
ac or dc.

2 SPECIAL MEASUREMENTS AND FUNCTIONS


- Measures voltage (ac. and dc.).
- Measures frequency.
- Measures the voltage output.
- Measures the phase angle.
6
- Measures the impedance of the load.
- Measures the apparent power (VA).
- Measures the current injected in % of the current rating of the relay under test.
- Measures instantaneously the maximum current injected (instantaneous test).
- Injection time can be limited.
- Injection values can be limited.
- Current can be pre-selected (PRESET).

3 RS-232 COM PORT


Used to control and communicate with external hardware to perform the
following:
• Connected to an computer:
- Calibration.
- Semi-automatic testing.
• Connection to a printer to directly print test results.

4 PTE-BUS
Allows the interconnection with any other unit in the PTE RANGE, enabling
an easy access for references, controls, etc.

5 CURRENT OUTPUTS
There are 4 current outputs and the regulation is through a variable
autotransformer (variac) and an output transformer.

6 BUILT-IN TIMER 7
The built-in timer can measure the time delay of the Relays under test with a
1 ms resolution. It is a digital timer incorporated in the PTE-100-C and
contains all the required inputs and outputs to start and stop the timer.

7 MAINS VOLTAGE SUPPLY


The voltage is supplied to the equipment by a standard SCHUKO male plug with
9 AUXILLARY DC VOLTAGE SUPPLY
ground. Contain in this is a main filter to eliminate possible perturbations from
entering the equipment. Standard 5 x 20 mm. fuses protects the input circuits. Electronically regulated, with a variable stabilized output. This dc output has 3
ranges (auto-range) up to 250V dc, 0.25A. Can be used simultaneously with
any other output.
8 AUXILIARY VOLTAGE OUTPUT
The auxiliary voltage output has a nominal voltage of 110V ac with a
maximum current of 0.3A. This output is fuse protected.
catalogo PTE-100-C ingles 15/7/00 12:47 Página 6

ACTUAL SIZE

3 4

5
2

10 12

8 9 11

10 OUTPUT PROTECTION 11 AC VOLTAGE OUTPUTS


The outputs and the unit are electronically protected against overload, Regulation is by a variable autotransformar and output transformer up to
shortcircuit and over temperature. The appropriate alarms are indicated 250V ac, 4 A. This output cannot be used simultaneously with the current
on the front panel.

12 DC VOLTAGE OUTPUTS
Regulations is by a variable autotransformar and output transformer up to
350V dc, 2.8 A. This output cannot be used simultaneously with the current
output.
catalogo PTE-100-C ingles 15/7/00 12:47 Página 7

PTE-FCC PTE-FCB
Load Option MCB Test
Option
Description: Mounted

software
in the top cover of the Description: To test MCB’S
PTE-100-C unit, the up to 250A on site.
PTE-FCC Load Option
Options
consists of a group of Technical characteristics:
power resistors and a
– Test panel with DIN rail
capacitor set, designed to be connected directly to the
mounted in top cover.
current output. The Resistance value is selected by
– Software to direct the test and to record and print test
connecting to the desired tap.
results.
Application: The application of the resistor set is to
increase the Load value when working with very low relay
loads.
This load improves the regulation of the current output value
and the output distortion in the waveform. This enables the
variac to work with a better efficiency.
The Capacitor can be combined with the Resistor set and PTE-FCE
different angle values up to nearly 90° can be obtained.
External Timer
Start Option
Technical characteristics: Description: Designed to
be used with the PTE-100-C,
RESISTOR
Maximum Current (A)
thus giving the equipment a wider application in measuring
Value (±5%)
Ω Permanent 1 Minute times.
0.5 20 30
This option is mounted in a small, lightweight box,
1 10 15
designed to be transported inside the lid of the PTE-100-C.
2 5 7.5
25 1.6 2 It is connected directly to the monitor input taps of the
50 0.8 1 equipment.
100 0.4 0.5
The voltage supply can be by the main voltage supply
Capacitor: –No polarity or by connecting to the 110V 0.3A tap (Out 4) of the
–Nominal voltage (dc): 450V
–Value: 10µF ±10% PTE-100-C.

Application: The option to use the built-in timer as an


independent timer, allowing the timer to start by an external
contact.
PTE-FCF
Variable Voltage
Technical characteristics:
Description:
Connected to the 110V INPUTS
auxiliary voltage Dry contact, power free (NO or NC): Optocoupled.
output, the PTE-FCF Voltage - open circuit: 15V d.c.
Current - short circuit: 8 mA.
enables regulation of
Protection: Standard fuse 5 x 20.
the fixed voltage Input taps are fully protected.
output in the PTE range from 10 to 120V with a maximum Indicative LED of associated working states.
current of 0.3A
Application: A battery simulator, a auxiliary voltage
supply required in relay testing.

Technical characteristics:
Output Maximum Current Accuracy Power
0V - 120V 0.25A 1V 30VA
catalogo PTE-100-C ingles 15/7/00 12:48 Página 8

PTE-OCT SOFTWARE PTE-TDC SOFTWARE


OVERCURRENT RELAYS TEST DATA
TEST SOFTWARE CAPTURE SOFTWARE
Description: The PTE-OCT Software is designed to This software is intended to aquire data from a PTE-100-C
software
preform semi-automatic overcurrent relay tests. The equipment, making easy the task of adquiring an adequate
software is WINDOWS based, with text and graphical data format in order to print or transfer results into a file.
presentation of results, Database handling, report, etc. The file can be Microsoft Access or a standard ASCII
format. It is possible to store test results and retrieve to print.
The software works with Inverse Time Overcurrent Relays
The software is developed in Windows and it is easy to
and Definite Time Overcurrent Relays
use. It enables identification of results, by means of a test
header where data can be introduced, such as dates,
locations codes, operator, device under test, etc. The
connection between PC and PTE-100-C is made by a cable
supplied with the equipment.

Inverse Time Overcurrent Relays


• General Condition Test.
• Creep Current Test.
• Run Back Time Test.
• Timing Curve Test.
• Tripping Time Test.
Definite Time Overcurrent Relays
• General Condition Test. STANDARD ACCESORIES
• Pick-Up, Drop-Out Test. • 1 voltage supply cable 1.5 m length.
• Tripping Time Test.
All the test results are recorded and stored in MS ACCESS • 2 connection cables 2 meters length
format. and 16 mm2 section for high currents.
The software includes a Graphic Curve Editor that enables
the user to create standard curves. These curves can be • 6 crocodile clips, input 4 mm.
used as the comparison standard by the software,
• 6 connection cables 2 meters length
comparing results against the expected value, in the Timing
and 2.5 mm2 section.
Curve Tests.

Applications • 2 adaptor plugs 6 mm to 4 mm.


• The test is “directed” by the software, including the test
• 1 RS-232 Cable.
current values.
• The storing of Test Results, as well is as the ID data of the
• Spare fuses.
relay under test.
• The automatic comparison of the Test Results with the • Instruction manual.
desired Standard Curve.
• The Open Database in ACCESS format, allows users to • 1 nylon protection bag.
create and also integrate results into planned
maintenance systems.
catalogo PTE-100-C ingles 20/7/00 17:18 Página 1

TECHNICAL SPECIFICATION
POWER OUTPUTS
OUTPUTS NO LOAD FULL LOAD MAXIMUM DUTY AUXILLARY AC MAXIMUM
VOLTAGE VOLTAGE CURRENT CYCLE VOLTAGE
VOLTAGE SUPPLY CURRENT
0-5 A 200V 163V 5.5A 1 min. ON / 15 min OFF
0-25A 40V 33V 27.5A 1 min. ON / 15 min OFF 110V AC (Fixed) 110V 0.3A

0-50A 20V 16V 55A 1 min. ON / 15 min OFF AUXILLARY DC MAXIMUM


0-100A 10V 7.6V 110A 1 min. ON / 15 min OFF VOLTAGE SUPPLY (OUT 3) VOLTAGE CURRENT

0-150A 10V 6.6V 150A 10 seg. ON / 5 min. OFF


0-50V DC 0-50V 1A
0-210A 10V 4.2V 210A 5 seg. ON / 5 min. OFF
0-250A 10V 4.2V 250A 3 seg. ON / 5 min. OFF
0-125V DC 50-125V 0.5A
0-250V AC 285V 220V 4A 10 min. ON / 15 min. OFF
0-350V DC 292V 270V 2.8A 5 min. ON / 15 min. OFF 0-250V DC 125-250V 0.25A

MEASUREMENT FUNCTIONS SPECIFIC SELECTION FUNCTIONS


MEASURE CURRENT VOLTAGE VOLTAGE FREQ. VOLT. TAP PHASE ANGLE POWER IMPEDAN. In PERCENTAGE TIME LIMIT CURRENT PRESET
FUNCTION (AC) (AC) (DC) (Hz) (AC) (degrees) (VA) (Ω) (A) (s.) LIMIT (A) CURRENT (A)

MIN 0.0070 000.1 000.1 20.000 0.01 000.0 00.01 0.001 00.1 0.01 0.1 0.1

MAX 299.9 300.0* 400.0* 2000.0 199.9 359.9 999.9 999.9 99.99 99.99 100.0 100.0

ACCURACY ±1% R ±1% R ±1% R ±0.003 Hz ±1% R ±2° ±2% R ±2% R - - - -


(10% to
±1 dig. ±1 dig. ±1 dig. ±1 dig. ±1 dig. ±1 dig. ±1 dig. ±1 dig.

Please Note: Due to the continuous research and development by EUROSMC, specifications in this catalog may be changed without previous notice.
full range) - - - -

RESOLUTION 0.001 0.1 0.1 0.01 0.01 0.1° 0.01 0.001 0.01 0.01 0.1 0.1
* Up to 1,000V with the PTE-FCH option

BUILT-IN TIMER SIGNAL MONITOR


MEASURING RANGES: Time: 0.001 to 99999 s. (autorange). Dry Contact Input
Cycles: 000.1 to 9999.9 Cycles (referenced frequency). • Open circuit voltage: 10.2 V. D.C.

ACCURACY: ±0.003% of the reading ±1 dig. • Short-circuit current: 25 mA.


• Fuse protected.
TIME START: By activation/deactivation of the power output.
Voltage Input
TIMER STOP: Selectable between activation or deactivation of the Signal Monitor.
• Level Limits: from 5 to 250 V A.C./D.C.
• Input Impedance: 19 KΩ
• Fuse protected.
GENERAL
Temperature Range: Operation: 0 - 50° C / Storing: -20° - 70° C
Voltage supply: 230 V ± 10% 50-60 Hz
115 V ± 10% 60 Hz.
Dimensions: Height: 200 mm Width: 300 mm Depth: 200 mm
8” 12” 8”
Weight: 13,5 Kg. - 30 lb.

DISTRIBUTED BY:

EUROSMC, S.A.
Polígono Industrial P-29, Calle Buríl, Nave 2. 28400 Collado-Villalba.
Madrid (Spain). Tels: 34 - 91 - 849 89 80*. Fax: 34 - 91 - 851 25 53
www.eurosmc.com • e-mail: [email protected]