Open navigation menu
Close suggestions
Search
Search
en
Change Language
Upload
Sign in
Sign in
Download free for days
0 ratings
0% found this document useful (0 votes)
154 views
27 pages
Drawings Isolators Tritech
Uploaded by
Ganesh Velu
AI-enhanced title
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content,
claim it here
.
Available Formats
Download as PDF or read online on Scribd
Download now
Download
Save drawings-isolators-tritech For Later
Download
Save
Save drawings-isolators-tritech For Later
0%
0% found this document useful, undefined
0%
, undefined
Embed
Share
Print
Report
0 ratings
0% found this document useful (0 votes)
154 views
27 pages
Drawings Isolators Tritech
Uploaded by
Ganesh Velu
AI-enhanced title
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content,
claim it here
.
Available Formats
Download as PDF or read online on Scribd
Download now
Download
Save drawings-isolators-tritech For Later
Carousel Previous
Carousel Next
Download
Save
Save drawings-isolators-tritech For Later
0%
0% found this document useful, undefined
0%
, undefined
Embed
Share
Print
Report
Download now
Download
You are on page 1
/ 27
Search
Fullscreen
TRETIGH CORPORATION GUARANTEED TECHNICAL PARTICULARS TRANSMISSION CORPORATION OF ANDHRA PRADESH LTD. ai Zea | GTPS FOR 33KV,800/1200/2000 AMPS ISOLATOR. ‘Sr.No. Description Particulars 4) Typelinstallation DBCR OUTDOOR TYPE 2) Manufacturers Name and Country oF TRITECH Manufacture CORPORATION, INDIA a ‘Standards according to which the isolators are _| 1S 9921,IEC129 manufactured 4) Maximum design voltage at which the isolator | 36 KV can operate (kV) 3) Frequency (Hz) SOHZ 6) Rated Voltage (kV) ‘33 KV 7) Maximum current that can be safely interrupted by the isolator 2) | Inductive (A & % PF) 07 AGUS PF ) | Capacitive (A & % PF)
[email protected]
8 Continuous current rating Nominal (Amps) 800/1200/2000 AMPS Under site conditions (Amps) 3) Rated short time current @) | For 3 seconds (KA rms) 25 KA RMS. [= “) |For T second (kA rms) E [ ‘C) | Rated peak short time current (kVp) 63 KAP. ) Current density at the minimum cross-section of | 800 1200 2000 @) | Moving blade (Amps/Sq.mm) 25 25 2.5 b) | Terminal pad AL10 | AL10 | AL. 10 ¢) | Contacts 2 2 I <@) | Terminal Connector 7 4 1.25 [11)_ | Maximum Temp. rise of current carrying parts | WITHIN LIMITS OF ISIEC when carrying rated current continuously (deg.c) 12) | Derating factor for specified site conditions UNITY 13)__| Insulation Levels. 2) | Impulse withstand volage (KV peak) Phase to | 170 KVII95 KVP Earth & Isolating Distance [gy | Switching surge withstand voltage (kV peak) | NOT APPLICABLE Phase to Earth & Isolating Distance | 6) | Power Frequency withstand vottage (kV ims) | 70/60 KV RMS FOR Phase to Earth & Across isolating Distance ‘Tritech Corporation, Gajra Udyog Ware House Complex, OPP. Rajur Bahula, Mumbai- Agra Highway, Nashik-422010. E- Mai Satyakrishna1957¢ |.com, MOB : 9441210508, MINUTE lirmal Ashram Gurudwara
[email protected]
ii) No. of bearings, location and size 2, BELOW ROTATING INSULATOR STACK. 1) [Tandem pipe’ i) Size, length, class and no. of pipes | 25MM 1D,CL BGI PIPE-3.5 M ii) Size of shackle, screw [lily No. of bearings/bush and its material and size BRASS BUSH. im) | Type of interlock MECHANICAL. n) | Down pipe size, length and class 38 NB.CLB.GI PIPE ©) | Type of universa/swivel joint 7) Between bearing and down pipe. UNIVERSAL, ii) Between down pipe and operating mechanism | VERNIER TYPE. ‘Operating mechanism: MAIN AND EARTH:MANUAL °) TYPE i) Control cabinet Material and thickness (12 Gauge - 2.64mm) of | 2.64 MM Steel or 10 mm thick Aluminium or Casting. | Degree of protection P55 |_ Type size and No. of cable glands CONTRACTORS SCOPE Whether removable gland plate provided YES @) | Base. i) Size of steel sections used 100X50 MM FORMED ii) Overall size 4100X50X1070 MM. i) Total weight 8.50 KG POLE 7) | Terminal Connectors i) Clamp Body: ‘Alloy Composition AL ALLOY TOIS 617 Plating if any NOT APPLICABLE | Area at air cross -section 1600 SQ MM [ii) Bolts and nuts size Alloy Composition MS HOG AS PER REL IS STD. Tensie strength mana DO ii) Type of washers used FLAT AND SPRING iv) Materials of braids NOT APPLICABLE. v) Temperature rise when carrying rated current at 50 deg.c ambient (deg.c) WITHIN LIMITS OF IS 656% vv) Weight of each type of clamp (kg). ‘APP 1KG FOR SINGLE &2 KG FOR TWIN CONNECTOR14) | Minimum clearance in air: a) Between poles (mm) 1100MM FOR PHASE SPACING OF 1300 MM. ) | Between ve paris and earth (mm) 508MM ©) | Between live parts when switch is open i) On the same pole (mm) 715 MM FOR POLE SPACING OF 815 MM. i) Between adjacent poles (mm) 100MM. 15)__| Rated mechanical terminal load a) Load along the terminal connector side (kg.) _| NOT ASSIGNED IN IS/IEC |b) Load across the terminal connector side (kg.) _| NOT ASSIGNED INIS/IEC. 76) | Torque required to operate the switch in Kgm | MAIN-3SKGM,EARTH-35 | (Not specified) KGM. 47) | Contact Zone 2a) | Horizontal deflection (mm) NOT APPLICABLE FOR DOUBLE BREAK ISO. ») | Vertical deflection (mm) ====D0- Total amplitude of longitudinal movement w.rt. | ———-—-DO——— ©) | conductor supporting fixed contact (mm) 78) __| Design and Construction a) | No. of insulators per pole THREE STACKS/POLE 'b) | No. of breaks per pole MAIN-2,ES-SINGLE «)| Type of closing /Opening mechanism MAIN-HORIZONTAL EARTH (Horizontal/Vertical break straight etc.) SW-VERTICAL BREAK @) | Contacts: 800 | 4200 | 2000 | E/S i) Material and grade cu_|“cu [cu | cu il) Cross-sectional area (mm) 518_| 777 _| 1316 | 320 @) | Moving Blades: 00 | 4200 | 2000 | E/S i) Material and grade cu_[-cu [ cu [cu il) Cross-sectional area (mm) 427 | 644 | 1056 | 300 } | Contact Support: i) Material and size of channelblock MS HDG, 4M Til) Material and size of plate MS HDG., 6MM {@)_| Rain hood - Material grade and size MS HDG , 5MM h) | Tum and twist mechanism i) Material and size of clamps MS HDG. 6M il) Material size of springs. ‘SS, 2.64 MM DIA ili) Whether springs are encased YES i) | Nuts and Botts: 7) Size, material and grade in live parts LESS THAN 3/6” SS,ABOVE 5/8°HDG i) Size, material and grade in other parts 3/8" ABOVE HDG Insulator base plate Material and size of plate | MS HDG-10MM | below insulators | Bearings i) Material and size of housing AL ALLOY SUITABLE FOR (25 MM DIA SHAFT ABPROVEE wa AY chiar hh PEP SEnstruction APTRANSCO, Vidyut Soudi Hyderabad - 500 082. 9¢——— 2a AVIOVEOZET oe NOLLWYOddOD ae) = woanas HOE L < CLINI HS30Vad vaHONY ¥ | ia wotivatoaeoo NarsstwsNva | | ‘STIVL30 ONLLNNDN “TANNYHO 3sva SIV id S2ATIS 3v SLNIDd L9viNO9 sroaa4. NON Wy TTISINVA 2 wid 10M Ni Suave SAUNA TY Wr NT 3a SAOISNOWIC. TY =n € AVANASSY LOVINDD ONIADH HLRWa et 5 1 1 oO 6 1 8 S283 e “ 5 5 2 -MINGE @-SS¥I0 Ge AN Tuld TD HOOWWL é WSINVHOIN SNLWeSdD OL 6 SOL SN & e A WNaSSY L9¥ANGD SNIAD 3 5 AaNaSSy LO¥ANOD XLT ‘16 is? lava aS seep enone [teers eee Ty a [ Zz a Tapa a ge oo RN a eT esau pt vrei Hod a8 Soneee = e]2528,[= 2a dvIOOVORET “wel = — ar real was Samara wean ery Sr ereedfeat a eee WV ne or foe flared oe v HSA SIS We Tena anos NOLLWHOduOD| git HOSLIYL| [7] cauwr Hsatves vena Jo NoLiveen9 NeISSIMSN v «| STI130 ONTNNON “TENNVHO 3SvE Fd i > E i "| fe 2 A i 2 ae H $ i ‘OSV AAAS 3 SINOS LOVINGD SNORE MEN TY ts assiwvAwa uid LO Say Suva shawwad TY He i Yo NT Sav Suna TY i scam wera a eee # or on BM3SE RIE sav HH ONT NIVW 404 XO ONILVAEO “WANN 6 i g L} ont «BE AND 3dld ONTARIO 8 7 L Be sin € OsKOOH ENN SVE t SON 5 “SNH MOLYASTS 9 3 SON 2 MINCE a-ssvI0 «G2 aN) Sats TD HAUL & ‘SON € ‘ASOd TOOLS ONLLVLOS + as | San 6 cls & H SON E AnvaHaSsy LOvINGD SNIADK 8 H ‘SON 9 ATEW3SSY LDWINOD G3XI4 1 i ‘ALO ‘ist lavd ‘as 7 rhe ceed eee Me lean eg ee = oe s T £ I sr z I = i = I = = Z a {2@| caitsceta| Ty" dvooaMOzeW “or oa = “Sis BS OTATU TOL ie ‘aauW Ost e re cakivoo02/0021/008 AMEE wos ee) ly|_ SVL LOVINGO NIVH else pee oe TOVINOY-ORTAOW AIGA 3S TWVT ST NOUVASTS INOS ce| os PLAAO REY o~ NOLLWYOdUOD es om =: woairas |W OELUI| couIMn HszIvas vee 0 NOLLVIOANED WorssIMSIVeL | | 3 a) (i = w arxoot|oosat| v9 | over] sz | sc joost| ce | © |eexse} zt y) at SoCo eo vn ~. Hwee (eel ee ele fo [ee] om [am r| = | @% @”@ @ © f S| vm | Fed ® 7 a a = me Hf wi) oan enban |B ® i 9 nwa 2; 1 aN + i Loe Jair 4 a eames saa tose m4 ae {f= == eS —— q a ad to ‘ar = Hom ot wets Gd & E Pein mon am coments o] oe ica aearnmeaas * Fk Le areata He HH DouIRO AS HAT SWI et CSE : AIST faa otis nouvasTa 16 iy TSIAL NAM OG vid 3SvE_OW ISIAT RANI 3OF div 0 NBOHONIGaY OW ‘3S0H SaNL Wadd09" 9M CWS NU ONETAGIINS OW ‘AdONVS_OW Uy SERNWAD_ONLLwOGANS (Cv) Wd WAIN ‘49viNoa H_3 GS) SONTaIS OF y ‘aaa¥as WOH SHIDaY 3 GOON va I-94 Ast avd ras| r T z r = ¥ = = T Z i = -llel=[eleinlelelel=lelai=[216
You might also like
Quality Assurance Plan For MV Switchgear (Type - Unigear/Leangear Cubicle With " Vd4/Vind - Breaker")
PDF
No ratings yet
Quality Assurance Plan For MV Switchgear (Type - Unigear/Leangear Cubicle With " Vd4/Vind - Breaker")
3 pages
RPT - 3600727160 - Cable - Ampacity Study CYME
PDF
No ratings yet
RPT - 3600727160 - Cable - Ampacity Study CYME
77 pages
Guaranteed Technical Particulars For 66Kv Current Transformers S.No Description Guaranteed Particulars
PDF
No ratings yet
Guaranteed Technical Particulars For 66Kv Current Transformers S.No Description Guaranteed Particulars
2 pages
Janeshwar PCC 3.3 Based, Auto Sync, Auto Load Sharing. (Inb. 08.08.18 11,57)
PDF
No ratings yet
Janeshwar PCC 3.3 Based, Auto Sync, Auto Load Sharing. (Inb. 08.08.18 11,57)
28 pages
Disconnectors
PDF
No ratings yet
Disconnectors
75 pages
DWG Approved of ACSR Zebra Conductor
PDF
No ratings yet
DWG Approved of ACSR Zebra Conductor
7 pages
Intelineo 6000 2.0.0 Global Guide (1)
PDF
No ratings yet
Intelineo 6000 2.0.0 Global Guide (1)
1,541 pages
GAE630 Catalogue CA - 501 - GB - 0601
PDF
No ratings yet
GAE630 Catalogue CA - 501 - GB - 0601
38 pages
Is 15767 2008 PDF
PDF
100% (1)
Is 15767 2008 PDF
20 pages
42221-42422 - 66kv-30kv-11kv Heat Shrinkable Outdoor Termination Kit For XLPE Insulated Cable
PDF
No ratings yet
42221-42422 - 66kv-30kv-11kv Heat Shrinkable Outdoor Termination Kit For XLPE Insulated Cable
17 pages
Switchgear Manufacturing Company Pvt. LTD Smc-454-Rev-0
PDF
No ratings yet
Switchgear Manufacturing Company Pvt. LTD Smc-454-Rev-0
62 pages
OPGW Spec
PDF
No ratings yet
OPGW Spec
28 pages
110KV CT-1
PDF
No ratings yet
110KV CT-1
4 pages
3271005441XX316R01 As On 010222
PDF
No ratings yet
3271005441XX316R01 As On 010222
35 pages
UP Solar SCEPL SLD R2- Approved From SCL Side (1)
PDF
No ratings yet
UP Solar SCEPL SLD R2- Approved From SCL Side (1)
1 page
0260 573 PVE Y 233 03 Guaranteed Technical Particulars For GIS
PDF
No ratings yet
0260 573 PVE Y 233 03 Guaranteed Technical Particulars For GIS
36 pages
Substation List - PATAN MEHSANA
PDF
No ratings yet
Substation List - PATAN MEHSANA
2 pages
11kv 200a Ab Switch PDF
PDF
No ratings yet
11kv 200a Ab Switch PDF
2 pages
LASCPT & CT Panal Drawing
PDF
No ratings yet
LASCPT & CT Panal Drawing
22 pages
Cable Tray Catalogue.
PDF
No ratings yet
Cable Tray Catalogue.
18 pages
Is 398 (Part Iii) 1976
PDF
No ratings yet
Is 398 (Part Iii) 1976
17 pages
Disconnector ABB Topics.
PDF
No ratings yet
Disconnector ABB Topics.
14 pages
132kV 1250A Isolator GTP and Drawings
PDF
No ratings yet
132kV 1250A Isolator GTP and Drawings
12 pages
21121-EL-DWG-0023 - AC Cable Route Layout & Cross Section
PDF
No ratings yet
21121-EL-DWG-0023 - AC Cable Route Layout & Cross Section
2 pages
n 800kV_HVDC_WZ-4_Tower_spotting_data_and_SLD_tower
PDF
No ratings yet
n 800kV_HVDC_WZ-4_Tower_spotting_data_and_SLD_tower
13 pages
Analysis of Auxiliary Energy Consumption in Utility Scale Solar PV Power Plant
PDF
No ratings yet
Analysis of Auxiliary Energy Consumption in Utility Scale Solar PV Power Plant
2 pages
KPLC - 132 KV Isolator - Specifications
PDF
No ratings yet
KPLC - 132 KV Isolator - Specifications
10 pages
adaniTS_Composite Long Rod insulators Section-II
PDF
100% (1)
adaniTS_Composite Long Rod insulators Section-II
36 pages
Oblum Electrical Industries Private Limited
PDF
No ratings yet
Oblum Electrical Industries Private Limited
6 pages
3C. Switchgear Isolator
PDF
No ratings yet
3C. Switchgear Isolator
17 pages
Lightning Arresters: CG Power and Industrial Solutions Ltd. India
PDF
No ratings yet
Lightning Arresters: CG Power and Industrial Solutions Ltd. India
1 page
Reactors - Specification: Indian Standard
PDF
No ratings yet
Reactors - Specification: Indian Standard
9 pages
11kV OUTGOING VCB 18.4KA, CTR: 200-100/5+5A .: Technical Specifications (D) Circuit Breaker
PDF
No ratings yet
11kV OUTGOING VCB 18.4KA, CTR: 200-100/5+5A .: Technical Specifications (D) Circuit Breaker
11 pages
CVT Comments Arkay
PDF
No ratings yet
CVT Comments Arkay
3 pages
RRVPNL
PDF
No ratings yet
RRVPNL
51 pages
Optical Fiber
PDF
No ratings yet
Optical Fiber
2 pages
GTP ACSR WEASEL
PDF
100% (1)
GTP ACSR WEASEL
4 pages
Disconnector Catalogue
PDF
100% (1)
Disconnector Catalogue
68 pages
Crs-Gid-208-El-Baw-Sa-2043 R0 5.03.2014
PDF
No ratings yet
Crs-Gid-208-El-Baw-Sa-2043 R0 5.03.2014
6 pages
Appoved Letter & Drawing of 400 KV Disconnector of Medhasal
PDF
No ratings yet
Appoved Letter & Drawing of 400 KV Disconnector of Medhasal
31 pages
Development of 765 KV AC Transmission KEPCO
PDF
No ratings yet
Development of 765 KV AC Transmission KEPCO
4 pages
DATUM 0.000m Levels DATUM 0.000m Levels DATUM 0.000m
PDF
No ratings yet
DATUM 0.000m Levels DATUM 0.000m Levels DATUM 0.000m
1 page
10 400 KV PANTO Isolator R2 Jan12
PDF
No ratings yet
10 400 KV PANTO Isolator R2 Jan12
39 pages
BPI Specifications Rev 0
PDF
No ratings yet
BPI Specifications Rev 0
4 pages
7SR5 Engineering Guide Version
PDF
No ratings yet
7SR5 Engineering Guide Version
146 pages
Technical Specification: Odisha Power Transmission Corporation Limited
PDF
No ratings yet
Technical Specification: Odisha Power Transmission Corporation Limited
55 pages
Scada Schedule of Prices (Reference Only) : No. Description Q'ty
PDF
100% (1)
Scada Schedule of Prices (Reference Only) : No. Description Q'ty
1 page
440kv GSS
PDF
No ratings yet
440kv GSS
37 pages
Technical Specifications For Bird Flight Diverter
PDF
No ratings yet
Technical Specifications For Bird Flight Diverter
19 pages
Ga Drawing Dry
PDF
No ratings yet
Ga Drawing Dry
3 pages
Substation Battery Charger
PDF
No ratings yet
Substation Battery Charger
2 pages
Punto de Entrega de Transelectric - Quevedo: Tap1 - GLR
PDF
No ratings yet
Punto de Entrega de Transelectric - Quevedo: Tap1 - GLR
1 page
Central Electricity Authority (Technical Standards for Construction of Electrical Plants and Electric Lines) Regulations, 2022
PDF
No ratings yet
Central Electricity Authority (Technical Standards for Construction of Electrical Plants and Electric Lines) Regulations, 2022
97 pages
ABB REF615 - H Product Selection Tool - de
PDF
No ratings yet
ABB REF615 - H Product Selection Tool - de
3 pages
33kV Outdoor Isolator Data Sheet
PDF
No ratings yet
33kV Outdoor Isolator Data Sheet
1 page
ANNEX 01 - Technical Specifications: 1. 220kV Circuit Breaker
PDF
100% (2)
ANNEX 01 - Technical Specifications: 1. 220kV Circuit Breaker
4 pages
132kv Gr Power Gtps
PDF
No ratings yet
132kv Gr Power Gtps
21 pages
SOR Elect 2003 (3) General
PDF
No ratings yet
SOR Elect 2003 (3) General
13 pages
MCC Panel (Ventilation System)
PDF
No ratings yet
MCC Panel (Ventilation System)
25 pages
11 KV 800A Isolator WEB Approved GTP.o
PDF
No ratings yet
11 KV 800A Isolator WEB Approved GTP.o
4 pages