0% found this document useful (0 votes)
193 views2 pages

Ascona Datasheet1

This document provides specifications for various dimensional measurement models from the promex line. It lists different models of the promex BASIC, ADVANCED, and EXPERT series, along with their measuring field sizes, accuracies, and other technical details. The promex EXPERT series offers the largest measurement fields, highest accuracies down to ±5μm, and measuring times from 2 to 20 seconds depending on the model and field size. All of the promex systems are designed to operate between 10 and 40 degrees Celsius.

Uploaded by

R J
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
193 views2 pages

Ascona Datasheet1

This document provides specifications for various dimensional measurement models from the promex line. It lists different models of the promex BASIC, ADVANCED, and EXPERT series, along with their measuring field sizes, accuracies, and other technical details. The promex EXPERT series offers the largest measurement fields, highest accuracies down to ±5μm, and measuring times from 2 to 20 seconds depending on the model and field size. All of the promex systems are designed to operate between 10 and 40 degrees Celsius.

Uploaded by

R J
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Dimensional measurement Dimensional measurement

ALUMINIUM ALUMINIUM
promex BASIC / ADVANCED FAST promex EXPERT
MODEL promex BASIC FAST promex BASIC FAST MODEL promex EXPERT promex EXPERT
190/135 1,2 190/135 F *,1,2 180/120 2,3 180/180 2,4
Measuring field size 190 x 135 mm 190 x 210 mm or 135 x 300 mm Measuring field size 180 x 120 mm 180 x 180 mm
Measuring accuracy ± 20 μm ± 20 μm ≤ 190 x 135 mm Measuring accuracy ± 10 μm ± 10 μm ≤ 180 x 120 mm
± 40 μm > 190 x 135 mm ± 20 μm > 180 x 120 mm

MODEL promex ADVANCED FAST promex ADVANCED FAST MODEL promex EXPERT promex EXPERT
190/135 1,2 190/135 F *,1,2 220/180 LC 2,3 220/180 K RLC 1,3
Measuring field size 190 x 135 mm 190 x 210 mm or 135 x 300 mm Measuring field size 220 x 180 mm 220 x 180 mm
Measuring accuracy ± 20 μm ± 20 μm ≤ 190 x 135 mm Measuring accuracy ± 20 μm ± 30 μm
± 40 μm > 190 x 135 mm

¹ Sample length: max. 5 cm | ² Measuring time: 2 - 5 sec. | F* = 2 - 5 sec. + Handling time


MODEL promex EXPERT promex EXPERT
220/180 K RLC F *,1,3 220/300 LC 2,4
Measuring field size 360 x 180 mm or 220 x 280 mm 220 x 300 mm
Measuring accuracy ± 30 μm ≤ 220 x 180 mm ± 20 μm ≤ 220 x 180 mm
promex EXPERT ± 60 μm > 220 x 180 mm ± 40 μm > 220 x 180 mm

MODEL promex EXPERT MODEL promex EXPERT promex EXPERT


110/70 1,3 220/500 LC 2,4 220/700 LC 2,4
Measuring field size 110 x 70 mm Measuring field size 220 x 500 mm 220 x 700 mm
Measuring accuracy ± 5 μm Measuring accuracy ± 20 μm ≤ 220 x 180 mm ± 20 μm ≤ 220 x 180 mm
± 40 μm > 220 x 180 mm ± 40 μm > 220 x 180 mm

MODEL promex EXPERT promex EXPERT MODEL promex EXPERT promex EXPERT
115/95 K RLC 1,3 115/95 K RLC F *,1,3 260/170 2,3 260/300 2,4
Measuring field size 115 x 95 mm 170 x 95 mm or 115 x 130 mm Measuring field size 260 x 170 mm 260 x 300 mm
Measuring accuracy ± 20 μm ± 20 μm ≤ 115 x 95 mm Measuring accuracy ± 10 μm ± 10 μm ≤ 260 x 170 mm
± 40 μm > 115 x 95 mm ± 20 μm > 260 x 170 mm

MODEL promex EXPERT promex EXPERT MODEL promex EXPERT promex EXPERT
175/145 K RLC 1,3 175/145 K RLC F *,1,3 260/500 2,4 260/700 2,4
Measuring field size 175 x 145 mm 290 x 145 mm or 175 x 230 mm Measuring field size 260 x 500 mm 260 x 700 mm
Measuring accuracy ± 25 μm ± 25 μm ≤ 175 x 145 mm Measuring accuracy ± 10 μm ≤ 260 x 170 mm ± 10 μm ≤ 260 x 170 mm
± 50 μm > 175 x 145 mm ± 20 μm > 260 x 170 mm ± 20 μm > 260 x 170 mm

1
Sample length: 6,5 - 8 cm | 2
Sample length: 10 - 40 cm | 3
Measuring time: 2 - 5 sec.
F* = 2 - 5 sec. + Handling time | 4
Measuring time: 3 - 20 sec.

Operating and storage environment: Operating and storage environment:


Temperature range (without air conditioner): Operation: 10°C - 40°C (50°F - 104°F); Storage: -40°C - 65°C (-40°F -149°F) Temperature range (without air conditioner): Operation: 10°C - 40°C (50°F - 104°F); Storage: -40°C - 65°C (-40°F -149°F)
Relative humidity (maximum): Operation: 20 % - 80 % (non-condensing); Storage: 5% - 95% (non-condensing) Relative humidity (maximum): Operation: 20 % - 80 % (non-condensing); Storage: 5% - 95% (non-condensing)
Repeatable measuring accuracy based on Measurement System Capability Type1 Cg / Cgk-Study Repeatable measuring accuracy based on Measurement System Capability Type1 Cg / Cgk-Study
according to DIN EN ISO 9001/10012, QS.9000, VDA 6,1 GUM and ISO 14253-1 Version 11/2022 according to DIN EN ISO 9001/10012, QS.9000, VDA 6,1 GUM and ISO 14253-1 Version 11/2022
Dimensional measurement

ALUMINIUM
promex EXPERT
MODEL promex EXPERT promex EXPERT
300/300 LC 2,4 300/500 LC 2,4
Measuring field size 300 x 300 mm 300 x 500 mm
Measuring accuracy ± 20 μm ≤ 220 x 180 mm ± 20 μm ≤ 220 x 180 mm
± 40 μm > 220 x 180 mm ± 40 μm > 220 x 180 mm

MODEL promex EXPERT promex EXPERT


300/700 LC 2,4 340/500 2,4
GLOBAL INNOVATIVE
Measuring field size 300 x 700 mm 340 x 500 mm
Measuring accuracy ± 20 μm ≤ 220 x 180 mm ± 10 μm ≤ 260 x 170 mm
± 40 μm > 220 x 180 mm ± 20 μm > 260 x 170 mm

MODEL promex EXPERT promex EXPERT


340/700 2,4 380/500 LC 2,4
Measuring field size 340 x 700 mm 380 x 500 mm
Measuring accuracy ± 10 μm ≤ 260 x 170 mm ± 20 μm ≤ 220 x 180 mm
± 20 μm > 260 x 170 mm ± 40 μm > 220 x 180 mm

MODEL promex EXPERT promex EXPERT


380/700 LC 2,4 420/500 2,4
Measuring field size 380 x 700 mm 420 x 500 mm
Measuring accuracy ± 20 μm ≤ 220 x 180 mm ± 10 μm ≤ 260 x 170 mm

www.ascona.de
± 40 μm > 220 x 180 mm ± 20 μm > 260 x 170 mm

MODEL promex EXPERT


420/700 2,4
Measuring field size 420 x 700 mm
Measuring accuracy ± 10 μm ≤ 260 x 170 mm
± 20 μm > 260 x 170 mm

1
Sample length: 6,5 - 8 cm | 2
Sample length: 10 - 40 cm | 3
Measuring time: 2 - 5 sec.
F* = 2 - 5 sec. + Handling time | 4
Measuring time: 3 - 20 sec.

Operating and storage environment:


Temperature range (without air conditioner): Operation: 10°C - 40°C (50°F - 104°F); Storage: -40°C - 65°C (-40°F -149°F)
Relative humidity (maximum): Operation: 20 % - 80 % (non-condensing); Storage: 5% - 95% (non-condensing)
Repeatable measuring accuracy based on Measurement System Capability Type1 Cg / Cgk-Study
according to DIN EN ISO 9001/10012, QS.9000, VDA 6,1 GUM and ISO 14253-1 Version 11/2022

You might also like