Botticelli Smart BT A - Instruction Manual
Botticelli Smart BT A - Instruction Manual
BOTTICELLI SMART BT A
850-1250
INSTALLATION AND USER’S MANUAL AUTOMATION FOR OVERHEAD AND SECTIONAL GARAGE DOORS
1 2 3
BRTS
Not supplied
M8 M8
4,8x22
M8x30
M8x16 3,9x13
M8X60 S10
M8x60
EQUIPMENT
*
PH1/PH2
Ø5 Ø10 13/17
13 Ferro Muro
Iron Wall
Fer Mural
PH1/PH2
Eisen Mauer
Hierro Pared
Ijzer Muur
* For installations that require the operator to operate at heights greater than 2 meters above the floor level, it is mandatory to use equipment with higher safety levels
such as scaffolding or rolling towers. For activities outside Italy, check the specific local legislation in advance.
108÷116 mm
*Not supplied
200 mm
*Not supplied
200 mm
It is suggested that the operator be set so that the front branch of the lever
is as horizontal as possible (see figure), considering in any case that the
installer must verify that the regulation concerning impacts must be
complied with.
145°~
B DIMENSIONS
3200 / 3800
66
,5
44.5
33.5
115
127 2290 / 2890* 50
115
215 2840 / 3440 331
3150 / 3750
RAIL ASSEMBLY
C
Chain
New
Single rail,
Belt
New Old
1 2 3
y
OK
y
z
y z
4 5 17 mm
6
OK
z
m
m
18
z 4
PH1
8
BOTTICELLI SMART BT A 850-1250 - 5
D813948 03A00_04
FIXING OF THE CEILING “RAIL SUPPORT BRACKET
D
48 mm
D1 V2
Ø10
F1
V1 V2
13 mm
F1
Ø10 mm
V1 D1 V2
Ø10 mm
8 8
13
60 8 16
Ø10 mm
Ø10 mm
6,3
Ø10 mm
PH2
60
PH2
* *
Ø10 mm Ø10 mm
* *
* *
* *
* Not supplied.
= =
13 mm
max
Ø10 mm
5,5 mm
13
PH2
3
1
D1
V1 V3
V3
4
V2
V1 V2 V3 D1
D1 2 6
8
8
8
40 30
13
60
8
2
3
1
4,8
V1
V1
25
3,5
V2
PH1 V2
PH2
PH2
25
V1
2
Ø5
1
3 V2
PH1
4,8
3,9
V1
Ø 5 mm
V2
PH2
PH2
13 25
1 *
2
* *
PH2
4,2
13
4
KO
>30 s
......
KO
>30 s
......
KO
5s
>30 s
......
KO
......
OK
fast
WARNING!! Check that the force of impact measured at the points provided for by standard EN 12445 is lower than the value laid down by standard EN 12453.
Warning!! While the autoset function is running, the obstacle detection function is not active. Consequently, the installer must monitor the automated system’s
movements and keep people and property out of range of the automated system.
NO
NC
NO
NC
NC
24 VSafe+
AUX 3
24V +
24V -
SAFE 2
SAFE 1
STOP
COM
IC 2
IC 1
73 72 71 60 62 61 52 51 50 27 26
70 21 20
Courtesy lamp,
Fuse,
SAFE1 SAFE2
DE
(1PHOT / 1 PHOT OP/ 1 PHOT CL) (1PHOT / 1 PHOT OP/ 1 PHOT CL)
50 51 70 72 50 51 70 73
FA
24V-
24V+
24V-
24V+
SAFE1= 0,2,4
SAFE2= 0,2,4
TEST OFF
UL
T
1 TX1 RX1 1 1 TX1 RX1 1
2 2 2 2
3 3
4 4
5 5
(1 PHOT / 1 PHOT OP/ 1 PHOT CL) (1 PHOT / 1 PHOT OP/ 1 PHOT CL)
50 51 52 70 72 50 51 52 70 73
24V-
24V+
24Vsafe+
24V-
24V+
24Vsafe+
SAFE2= 1,3,5
SAFE1= 1,3,5
TEST ON
1 TX1 1 1 TX1 1
2 RX1 2 2 RX1 2
3 3
4 4
5 5
(1 BAR / 1 BAR OP/ 1 BAR CL) (1 BAR / 1 BAR OP/ 1 BAR CL)
50 51
DE 70 72 50 51 70 73
FA
SAFE2= 6,9,12
24V-
24V+
24V-
24V+
SAFE1= 6,9,12
UL
TEST OFF
51 6
72 5
4
70 3
T
BAR
51 6
73 5
4
70 3 BAR
50 2 50 2
51 1 51 1
(1 BAR / 1 BAR OP/ 1 BAR CL) (1 BAR / 1 BAR OP/ 1 BAR CL)
50 51 52 70 72 50 51 52 70 73
SAFE1= 7,10,13
SAFE2= 7,10,13
24V-
24V+
24Vsafe+
24V-
24V+
24Vsafe+
TEST ON
52 6 52 6
72 5 73 5
4 BAR 4 BAR
70 3 70 3
50 2 50 2
51 1 51 1
(BAR 8K2/ BAR 8K2 OP/ BAR 8K2 CL)
SAFE1= 8,11,14,16
70 72
TEST ON
8,2Kohm 5%
tor supply
Mo- Power
JP2 TRANSF SEC Board power supply:
24V~ Transformer secondary winding
AUX 3 - FREE AUX 3 configurable output - Default setting MONOSTABLE RADIO CHANNEL
26 Output MONOSTABLE RADIO CHANNEL/ SCA GATE OPEN LIGHT/ COURTESY LIGHT command/ ZONE LIGHT command/ STAIR
CONTACT (N.O.) LIGHT/ GATE OPEN ALARM/ FLASHING LIGHT/ SOLENOID LATCH/ MAGNETIC LOCK/MAINTENANCE/ FLASHING LIGHT AND MAIN-
27 (MAX. 24V 1A) TENANCE / GATE CLOSED STATUS / BISTABLE RADIO CHANNEL / TIMED RADIO CHANNEL / GATE OPEN STATUS
Accessories
50 24V-
Accessories power supply output.
supply
power
51 24V+
52 24 Vsafe+ Tested safety device power supply output (photocell transmitter).
Output active only during operating cycle.
60 Common IC 1 and IC 2 inputs common
Commands
OK
3
1 *
2
* *
PH2
4,2
13
4
*supplied with the rail
auto . . . . . . . . . . . . . . . . . .
5s
fast
KO
fast
WARNING!! Check that the force of impact measured at the points provided for by standard EN 12445 is lower than the value laid
down by standard EN 12453.
Warning!! While the autoset function is running, the obstacle detection function is not active. Consequently, the installer must monitor
the automated system’s movements and keep people and property out of range of the automated system.
<10 s <10 s
2s o o o o o
1 2 3 4 5 6 7
10 s 10 s
TRANSMITTERS CANCELLATION
H
P
5s
prg
Exit Menù
See LOGIC MENU
erase 64
• ≥ 5 sec Cancellation of remote controls
ok If cancelled
erase 1 ( 0001 ) KO If not present
dis If clone, it is disabled
• Access menu
• ≥ 5 sec menu autoset
02.01 02 Travel less than the minimum required travel, about 50 cm.
The installation is too "resilient/oscillating". Tighten it by
........ 03 adding a mechanical stop to the closure limit-switch (kit
code I100025 10005) before performing a further autoset.
30.15
+/-
* X = 0,1,…,9,A,B,C,D,E,F
ENGLISH
Automatic closing
TCA 0 180 40 Waiting time before automatic closing.
time [s]
Lighting time of the Lighting time of the courtesy light [s] Activation time of the courtesy light on the board
t.light 30 300 90 courtesy light [s]
Slow-down distance for motor(s) during opening, given as a percentage of total travel.
OP.DIST. Slow-down distance WARNING: Once the parameter has been edited, a complete uninterrupted opening-
7 99 7
SLOUD during opening [%] closing cycle is required.
WARNING: when the display reads “SET”, obstacle detection is not active.
Slow-down distance for motor(s) during closing, given as a percentage of total travel.
CL.DIST. Slow-down distance WARNING: Once the parameter has been edited, a complete uninterrupted opening-
7 99 7 during closing [%] closing cycle is required.
SLOUD
WARNING: when the display reads “SET”, obstacle detection is not active.
PARTIAL 1 99 20 Partial opening [%] Partial opening distance as a percentage of total opening following activation of PED pedestrian
OPENING command.
Force exerted by leaf/leaves during opening. This is the percentage of force delivered, beyond
the force stored during the autoset cycle (and subsequently updated), before an obstacle alarm
is generated.
Leaf force during
OP.FORCE 1 99 75 opening [%] The parameter is set automatically by the autoset function.
WARNING: It affects impact force directly: make sure that current safety requirements
are met with the set value (*). Install anti-crush safety devices where necessary (**).
Force exerted by leaf/leaves during closing. This is the percentage of force delivered, beyond the
force stored during the autoset cycle (and subsequently updated), before an obstacle alarm is
generated.
Leaf force during
CLS.FORCE 1 99 75 closing [%] The parameter is set automatically by the autoset function.
WARNING: It affects impact force directly: make sure that current safety requirements
are met with the set value (*). Install anti-crush safety devices where necessary (**).
Percentage of maximum speed that can be reached by motor(s) during opening. WARNING: Once
OP SPEED 25 99 99 Opening speed [%} the parameter has been edited, a complete uninterrupted opening-closing cycle is required.
WARNING: when the display reads "SET", obstacle detection is not active.
Percentage of maximum speed that can be reached by motor(s) during closing. WARNING: Once
CL SPEED 25 99 45 Closing speed [%] the parameter has been edited, a complete uninterrupted opening-closing cycle is required.
WARNING: when the display reads "SET", obstacle detection is not active.
Programming num-
ber of operations
Mainte- 0 250 0 for maintenance Allows you to set a number of operations after which the need for maintenance will be reported
nance on the AUX output configured as Maintenance or Flashing Light and Maintenance .
threshold
[in hundreds]
(*) In the European Union, apply standard EN 12453 for force limitations, and standard EN 12445 for measuring method.
(**) Impact forces can be reduced by using deformable edges.
step-by-step mov.
Inputs configured as Start E, Start I, Ped oper- 3 STEP 4 STEP
0 ate with 4-step logic.
CLOSED OPENS
OPENS
STEP-BY-STEP Step-by-step 0 DURING CLOSING STOPS
MOVEMNT movement
OPEN CLOSES CLOSES
Inputs configured as Start E, Start I, Ped oper-
1 ate with 3-step logic. Pulse during closing DURING OPENING STOP + TCA STOP + TCA
reverses movement.
AFTER STOP OPENS OPENS
Cross
out
Logic Definition Default Optional extras
setting
used
0 Input configured as Phot (photocell).
Configuration 1 Input configured as Phot test (tested photocell).
of safety input
SAFE 1 6
SAFE 1.
72 2 Input configured as Phot op (photocell active during opening only).
3 Input configured as Phot op test (tested photocell active during opening only).
5 Input configured as Phot cl test (tested photocell active during closing only).
9 Input configured as Bar OP, safety edge with inversion active only while opening. If while closing, the movement stops.
Configuration Input configured as Bar OP TEST, safety edge tested with inversion active only while opening. If while closing, the
of safety input 10
SAFE 2 4 movement stops.
SAFE 2.
73 Input configured as Bar OP 8k2, safety edge with inversion active only while opening. If while closing, the movement
11 stops. (Inactive on SAFE 2).
12 Input configured as Bar CL, safety edge with inversion active only while closing. If while opening, the movement stops.
Input configured as Bar CL TEST, safety edge tested with inversion active only while closing. If while opening, the
13 movement stops.
Input configured as Bar CL 8k2, safety edge with inversion active only while closing. If while opening, the movement
14 stops. (Inactive on SAFE 2).
15 Not used
ENGLISH
Cross
out
Logic Definition Default Optional extras
setting
used
Receiver is configured for operation in rolling-code mode.
0 Fixed-Code Clones are not accepted.
FIXED CODE Fixed code 0
Receiver is configured for operation in fixed-code mode.
1 Fixed-Code Clones are accepted.
A - The password is not required to access the programming menus
B - Enables wireless memorizing of transmitters.
Operations in this mode are carried out near the control panel and do not require access:
- Press in sequence the hidden key and normal key (T1-T2-T3-T4) of a transmitter that has already been memori-
zed in standard mode via the radio menu.
- Press within 10 sec. the hidden key and normal key (T1-T2-T3-T4) of a transmitter to be memorized.
The receiver exits programming mode after 10 sec.: you can use this time to enter other new transmitters by
0 repeating the previous step.
C - Enables wireless automatic addition of clones.
Enables clones generated with the universal programmer and programmed Replays to be added to the recei-
ver’s memory.
D - Enables wireless automatic addition of replays.
Enables programmed Replays to be added to the receiver’s memory.
E - The board’s parameters can be edited via the U-link network
A - You are prompted to enter the password to access the programming menus
1 The default password is 1234.
No change in behaviour of functions B - C - D - E from 0 logic setting
Protection Setting the 0
A - You are prompted to enter the password to access the programming menus
level protection level The default password is 1234.
2 B - Wireless memorizing of transmitters is disabled.
C - Wireless automatic addition of clones is disabled. No change in behaviour of functions D - E from 0 logic
setting
A - You are prompted to enter the password to access the programming menus
The default password is 1234.
3 B - Wireless memorizing of transmitters is disabled.
D - Wireless automatic addition of Replays is disabled.
No change in behaviour of functions C - E from 0 logic setting
A - You are prompted to enter the password to access the programming menus
The default password is 1234.
B - Wireless memorizing of transmitters is disabled.
C - Wireless automatic addition of clones is disabled.
4 D - Wireless automatic addition of Replays is disabled.
E - The option of editing the board’s parameters via the U-link network is disabled.
Transmitters are memorized only using the relevant Radio menu.
IMPORTANT: This high level of security stops unwanted clones from gaining access and also stops radio interfe-
rence, if any.
Serial mode 0 Standard SLAVE: board receives and communicates commands/diagnostics/etc.
(Identifies how
board is con-
SERIAL MODE 0
figured in a BFT
network 1 Standard MASTER: board sends activation commands (START, OPEN, CLOSE, PED, STOP) to other boards.
connection).
Identifies board address from 0 to 119 in a local BFT network connection.
ADDRESS Address 0 [ ___ ] (see U-LINK OPTIONAL MODULES section)
Reversing During closure, after an obstacle is detected, the movement gets reversed for 2 seconds.
0 During opening, after an obstacle is detected, the manoeuvre gets interrupted and the automation is blocked.
op.revers.obst obstacle when 0
opening 1 Both while closing as well as opening, after an obstacle is detected, the movement gets reversed for 2 seconds.
0 Standard operation with sectional doors (General Notes Ref. Fig. 1 and 2)
brts BRTS 0
1 Operation with tip-up doors, fitted with BRTS accessory (General Notes Ref. Fig. 3)
0 Input configured as Start E command.
1 Input configured as Start I command.
2 Input configured as Open command.
3 Input configured as Close command.
4 Input configured as Ped command.
5 Input configured as Timer command.
6 Input configured as Timer Pedestrian command.
7 Input configured as Phot (photocell) safety.
8 Input configured as Phot op safety (photocell active during opening only).
Configuration
of EXPI1 input 9 Input configured as Phot cl safety (photocell active during closing only).
on input-output 10 Input configured as Bar safety (safety edge).
EXPI1 2
expansion
board. Input configured as safety Bar OP, safety edge with inversion active only while opening, if while closing the mo-
11
1-2 vement stops.
Input configured as safety Bar CL, safety edge with inversion active only while closing, if while opening the mo-
12 vement stops.
13 Input configured as Phot test safety, tested photocell.
14 Input configured as Phot op test safety, tested photocell active only while opening.
15 Input configured as Phot cl test safety, tested photocell active only while closing.
16 Input configured as Bar safety, tested safety edge.
Input configured as safety Bar OP test, safety edge with inversion active only while opening, if while closing the
17 movement stops.
Input configured as safety Bar CL test, safety edge with inversion active only while closing, if while opening the
18 movement stops.
Cross
out
Logic Definition Default Optional extras
setting
used
0 Input configured as Start E command.
1 Input configured as Start I command.
Configuration of
EXPI2 input 2 Input configured as Open command.
on input-output
EXPI2 3 3 Input configured as Close command.
expansion
board. 4 Input configured as Ped command.
1-3
5 Input configured as Timer command.
6 Input configured as Timer Pedestrian command.
0 Output configured as monostable Radio Channel.
1 Output configured as SCA (gate open light).
2 Output configured as Courtesy Light command.
Configuration of
EXPO2 output 3 Not used
on input-output
EXPO1 13 4 Not used
expansion
board 5 Not used
4-5
6 Not used
7 Not used
8 Not used
9 Output configured as Maintenance.
10 Not used
Configuration of 11 Not used
EXPO2 output
on input-output 12 Not used
EXPO2 16
expansion 13 Output configured as Gate Status
board
6-7 14 Output configured as Bistable Radio Channel
15 Output configured as timed Radio Channel
16 Output configured as open gate Status
(**) Active only if the output is configured as Monostable Radio Channel, Courtesy Light, Zone Light, Stair Light, Bistable Radio Channel or Timed Radio Channel.
ENGLISH
SAFE logic= 5 - Input configured as Phot cl test (tested photocell active during closing only.
Switches photocell testing on at start of operation. In the event beam is broken, photocell operation is disabled during opening. During closing, movement is reversed immediately.
SAFE logic= 6 - Input configured as Bar (safety edge) non tested (*) .
Enables connection of devices not equipped with supplementary test contacts. The command reverses movement for 2 sec.. If not used, leave jumper inserted.
SAFE logic= 7 - Input configured as Bar (tested safety edge.
Switches safety edge testing on at start of operation. The command reverses movement for 2 sec.
SAFE logic= 8 - Input configured as Bar 8k2. Input for resistive edge 8K2.
The command reverses movement for 2 sec.
SAFE logic=9 Input configured as Bar op, safety edge with active inversion only while opening, if activated while closing, the automation stops (STOP) .
Allows connecting devices not fitted with supplementary test contact. The operation while opening causes the movement to be reversed for 2 seconds, the operation while closing causes the
automation to stop. If not used, leave jumper inserted.
SAFE logic=10 Input configured as Bar op test, safety edge checked with active inversion only while opening, if activated while closing, the automation stops (STOP) .
Activates testing safety edges when starting operation. The operation while opening causes the movement to be reversed for 2 seconds, the operation while closing causes the automation to stop.
SAFE logic=11 Input configured as Bar 8k2 op, 8k2 safety edge with active inversion only while opening, if activated while closing, the automation stops (STOP)
The operation while opening causes the movement to be reversed for 2 seconds, the operation while closing causes the automation to stop.
SAFE logic=12 Input configured as Bar cl, safety edge with active inversion only while closing, if activated while opening, the automation stops (STOP).
Allows connecting devices not fitted with supplementary test contact. The operation while closing causes the movement to be reversed for 2 seconds, the operation while opening
causes the automation to stop. If not used, leave jumper inserted.
SAFE logic=13 Input configured as Bar cl test, safety edge checked with active inversion only while closing, if activated while opening, the automation stops (STOP).
Activates testing safety edges when starting operation. The operation while closing causes the movement to be reversed for 2 seconds, the operation while opening causes the automation to stop.
SAFE logic=14 Input configured as Bar 8k2 cl, safety edge with active inversion only while closing, if activated while opening, the automation stops (STOP) .
The operation while closing causes the movement to be reversed for 2 seconds, the operation while opening causes the automation to stop.
Logica SAFE= 15 - Non utilisé
Logica SAFE=16 - Input configured as STOP 8k2. The command interrupts the maneuver and blocks the automation.
(*) If “D” type devices are installed (as defined by EN12453), connect in unverified mode, foresee mandatory maintenance at least every six months.
TECHNICAL SPECIFICATIONS
ELECTRICAL DATA
Power supply 220-230V 50/60Hz
BOTTICELLI SMART BT A 850: 200W
Max. power absorbed from mains
BOTTICELLI SMART BT A 1250: 250W
Fuses see figure L-S
24V~ (180mA max)
Supply to accessories
24Vsafe (180mA max)
Blinker connection 24V~ max 25W
Courtesy light BFT model courtesy LED lamp 24V 2W
Operating temperature -20°C / +60°C
MECHANICAL DATA
BOTTICELLI SMART BT A 850: 850N
Pulling and pushing force
BOTTICELLI SMART BT A 1250: 1250N
BOTTICELLI SMART BT A 850 : 13m2
Leaf max.
BOTTICELLI SMART BT A 250 : 16m2
TRACK L.=2900 working stroke=2300 mm
Working stroke
TRACK L.=3500 working stroke=2900 mm
Belt track= 240
BOTTICELLI SMART BT mm/s
A 850 Chain track= 210
Maximum speed mm/s
BOTTICELLI SMART BT Chain track= 190
A 1250 mm/s
Manoeuvres in 24 hours@ BOTTICELLI SMART BT A 850: 50
MAX+60°C BOTTICELLI SMART BT A 1250: 100
Manoeuvres in 1 hour@ MAX+50°C 10
Typical instal- 100 consecutive ma-
BOTTICELLI SMART BT A 850: mq 6,7
lation of sec- noeuvres
tional doors
BOTTICELLI SMART BT A 1250: mq 15,7 50 consecutive ma-
at 20°C noeuvres
Impact reaction integrated torque limiter on control panel
Limit switch Electronic with ENCODER
Lubrication permanent grease
Degree of protection IP20
Motor head weight 5 kg
Noise level <70dB(A)
Dimensions see fig.B
Preliminary checks
• Check that the door is balanced.
• Check that the door slides smoothly along its entire travel.
• If the door has not been newly installed, check the wear condition of all its
components.
• Repair or replace faulty or worn parts.
• The automation reliability and safety are directly influenced by the state of
the door structure.
• Before fitting the motor, remove any superfluous ropes or chains and disable
any unnecessary appliances.
K
CLIC
FUSE REPLACEMENT
S
1 2
PH2
T ACCESSORIES
SET/S ST BT BAT
SM1 S
External release device Automatic bolt release device for spring-operated
with retracting handle for over-head doors. Fitted to the control arm, it Kit battery charger.
automatically releases the side door bolts.
External release device to be applied to the cre- sectional doors measuring
mone bolt already fitted to the overhead max 50mm.
door.