The document provides installation instructions for the BOTTICELLI SMART BT A 850-1250 garage door opener. It can be used for sectional garage doors up to 3 meters high, as well as overhead doors equipped with a towing arm. The opener features an irreversible gearmotor that keeps the door locked in the closed position. Diagrams show how to mount the opener for standard and high ceilings. Dimensions for the rail assembly and installation positions are also provided.

Uploaded by

Citac Knjiga
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
3K views20 pages

Botticelli Smart BT A - Instruction Manual

The document provides installation instructions for the BOTTICELLI SMART BT A 850-1250 garage door opener. It can be used for sectional garage doors up to 3 meters high, as well as overhead doors equipped with a towing arm. The opener features an irreversible gearmotor that keeps the door locked in the closed position. Diagrams show how to mount the opener for standard and high ceilings. Dimensions for the rail assembly and installation positions are also provided.

Uploaded by

Citac Knjiga
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 20

D813948 03A00_04 14-05-19

BOTTICELLI SMART BT A
850-1250

INSTALLATION AND USER’S MANUAL AUTOMATION FOR OVERHEAD AND SECTIONAL GARAGE DOORS

Caution! Read “Warnings” inside carefully!


D813948 03A00_04
GENERAL OUTLINE
The BOTTICELLI SMART BT A 850-1250 system is suitable for motorising sectional doors (fig. 1), protruding fully retracting spring-operated
over-head doors (fig. 2) and counterweight overhead doors provided with an appropriate towing arm (fig. 3). The overhead door must not be
higher than 3 metres. Its easy installation allows fast fitting without needing the door to be modified. The irreversible gearmotor keeps the
door locked in the closing position.

1 2 3

BRTS
Not supplied

2 BOTTICELLI SMART BT A 850-1250


KIT COMPOSITION
D813948 03A00_04

M8 M8
4,8x22
M8x30
M8x16 3,9x13
M8X60 S10
M8x60

M8X40 S10 6,3x60

EQUIPMENT

*
PH1/PH2

Ø5 Ø10 13/17
13 Ferro Muro
Iron Wall
Fer Mural
PH1/PH2

Eisen Mauer
Hierro Pared
Ijzer Muur

* For installations that require the operator to operate at heights greater than 2 meters above the floor level, it is mandatory to use equipment with higher safety levels
such as scaffolding or rolling towers. For activities outside Italy, check the specific local legislation in advance.

BOTTICELLI SMART BT A 850-1250 - 3


D813948 03A00_04
Motor installation on STANDARD ceiling
A

108÷116 mm

Balance the sectional door!

*Not supplied

200 mm

Motor installation on HIGHER ceiling (with extension)


>116 mm

Balance the sectional door!

*Not supplied

200 mm

It is suggested that the operator be set so that the front branch of the lever
is as horizontal as possible (see figure), considering in any case that the
installer must verify that the regulation concerning impacts must be
complied with.

145°~

4 BOTTICELLI SMART BT A 850-1250


D813948 03A00_04

B DIMENSIONS

3200 / 3800

66
,5
44.5

33.5

115
127 2290 / 2890* 50
115
215 2840 / 3440 331

3150 / 3750

127 2325 / 2925* 80

2905 / 3505 214


* usable travel

RAIL ASSEMBLY
C

Two piece rail,

Chain
New

BOTTICELLI SMART BT A BOTTICELLI SMART BT A


850-1250 850

Single rail,

Belt

New Old

1 2 3
y
OK

y
z
y z
4 5 17 mm
6
OK
z

m
m
18
z 4
PH1
8
BOTTICELLI SMART BT A 850-1250 - 5
D813948 03A00_04
FIXING OF THE CEILING “RAIL SUPPORT BRACKET
D

48 mm
D1 V2
Ø10
F1

V1 V2

13 mm
F1

Ø10 mm
V1 D1 V2
Ø10 mm

8 8
13
60 8 16

ASSEMBLY OF TRACK HOLDING BRACKET ONTO THE WALL


E1

Ø10 mm

Ø10 mm
6,3

Ø10 mm

PH2

60
PH2

CEILING RAIL FIXING WITH BRACKETS


E2

* *
Ø10 mm Ø10 mm

* *
* *

* *
* Not supplied.

= =
13 mm

max
Ø10 mm

5,5 mm
13
PH2

6 BOTTICELLI SMART BT A 850-1250


D813948 03A00_04

ASSEMBLY OF TRACK ONTO THE TRACK HOLDING BRACKET


F

3
1

D1
V1 V3
V3
4
V2

V1 V2 V3 D1
D1 2 6
8
8

8
40 30
13
60
8

HEAD ASSEMBLY TO RAIL


G

2
3
1
4,8

V1
V1
25
3,5

V2
PH1 V2
PH2
PH2

25

PARTICULAR INSTALLATIONS WITH ROTATED HEAD


H
For 90° head installations, mount the head to the rail before mounting the rail to the ceiling.

V1

2
Ø5

1
3 V2
PH1
4,8
3,9

V1
Ø 5 mm

V2
PH2
PH2

13 25

BOTTICELLI SMART BT A 850-1250 - 7


D813948 03A00_04
START UP WITH COVER CLOSED
HI
* supplied with the rail
OK
3

1 *
2
* *

PH2
4,2
13

4
KO
>30 s
......

KO
>30 s
......

KO
5s

>30 s
......
KO

......
OK
fast

WARNING!! Check that the force of impact measured at the points provided for by standard EN 12445 is lower than the value laid down by standard EN 12453.
Warning!! While the autoset function is running, the obstacle detection function is not active. Consequently, the installer must monitor the automated system’s
movements and keep people and property out of range of the automated system.

8 BOTTICELLI SMART BT A 850-1250


D813948 03A00_04

(MAX 24V 1A)


L
H

NO
NC

NO
NC
NC

24 VSafe+

AUX 3
24V +
24V -
SAFE 2
SAFE 1
STOP
COM
IC 2
IC 1
73 72 71 60 62 61 52 51 50 27 26
70 21 20

JP7 Optional board connector,

Courtesy lamp,

Fuse,

1,25 AT Palmtop programmer connector,

Display plus programming keys,


JP2

SAFE1 SAFE2
DE
(1PHOT / 1 PHOT OP/ 1 PHOT CL) (1PHOT / 1 PHOT OP/ 1 PHOT CL)

50 51 70 72 50 51 70 73

FA
24V-
24V+

24V-
24V+
SAFE1= 0,2,4

SAFE2= 0,2,4
TEST OFF

UL
T
1 TX1 RX1 1 1 TX1 RX1 1
2 2 2 2
3 3
4 4
5 5

(1 PHOT / 1 PHOT OP/ 1 PHOT CL) (1 PHOT / 1 PHOT OP/ 1 PHOT CL)

50 51 52 70 72 50 51 52 70 73
24V-
24V+
24Vsafe+

24V-
24V+
24Vsafe+

SAFE2= 1,3,5
SAFE1= 1,3,5
TEST ON

1 TX1 1 1 TX1 1
2 RX1 2 2 RX1 2
3 3
4 4
5 5

(1 BAR / 1 BAR OP/ 1 BAR CL) (1 BAR / 1 BAR OP/ 1 BAR CL)

50 51
DE 70 72 50 51 70 73

FA
SAFE2= 6,9,12
24V-
24V+

24V-
24V+
SAFE1= 6,9,12

UL
TEST OFF

51 6
72 5
4
70 3
T
BAR
51 6
73 5
4
70 3 BAR
50 2 50 2
51 1 51 1

(1 BAR / 1 BAR OP/ 1 BAR CL) (1 BAR / 1 BAR OP/ 1 BAR CL)

50 51 52 70 72 50 51 52 70 73
SAFE1= 7,10,13

SAFE2= 7,10,13
24V-
24V+
24Vsafe+
24V-
24V+
24Vsafe+
TEST ON

52 6 52 6
72 5 73 5
4 BAR 4 BAR
70 3 70 3
50 2 50 2
51 1 51 1
(BAR 8K2/ BAR 8K2 OP/ BAR 8K2 CL)
SAFE1= 8,11,14,16

70 72
TEST ON

8,2Kohm 5%

SAFETY EDGE SAFETY EDGE


72
70

BOTTICELLI SMART BT A 850-1250 - 9


ENGLISH
Terminal Definition Description

tor supply
Mo- Power
JP2 TRANSF SEC Board power supply:
24V~ Transformer secondary winding

JP7 MOT + ENCODER Connection motor and encoder

20 AUX 0 - 24V POWERED


CONTACT (N.O.) FLASHING LIGHT output .
21 The contact remains closed during the movement of the leaves.
(MAX. 1A)
Aux

AUX 3 - FREE AUX 3 configurable output - Default setting MONOSTABLE RADIO CHANNEL
26 Output MONOSTABLE RADIO CHANNEL/ SCA GATE OPEN LIGHT/ COURTESY LIGHT command/ ZONE LIGHT command/ STAIR
CONTACT (N.O.) LIGHT/ GATE OPEN ALARM/ FLASHING LIGHT/ SOLENOID LATCH/ MAGNETIC LOCK/MAINTENANCE/ FLASHING LIGHT AND MAIN-
27 (MAX. 24V 1A) TENANCE / GATE CLOSED STATUS / BISTABLE RADIO CHANNEL / TIMED RADIO CHANNEL / GATE OPEN STATUS
Accessories

50 24V-
Accessories power supply output.
supply
power

51 24V+
52 24 Vsafe+ Tested safety device power supply output (photocell transmitter).
Output active only during operating cycle.
60 Common IC 1 and IC 2 inputs common
Commands

Configurable command input 1 (N.O.) - Default START E.


61 IC 1 START E / START I / OPEN / CLOSE / PED / TIMER / TIMER PED
Refer to the “Command input configuration” table.
Configurable command input 2 (N.O.) - Default PED.
62 IC 2 START E / START I / OPEN / CLOSE / PED / TIMER / TIMER PED
Refer to the “Command input configuration” table.
70 Common STOP, SAFE 1 and SAFE 2 inputs common
The command stops movement. (N.C.)
Safety devices

71 STOP If not used, leave jumper inserted.


Configurable safety input 1 (N.C.) - Default BAR.
72 SAFE 1 PHOT / PHOT TEST / PHOT OP / PHOT OP TEST / PHOT CL / PHOT CL TEST / BAR / BAR TEST / BAR 8K2 / BAR OP / BAR OP TEST / BAR
8K2 OP/ BAR CL / BAR CL TEST / BAR 8K2 CL /STOP 8K2
Refer to the “Safety input configuration” table.
Configurable safety input 2 (N.C.) - Default PHOT.
73 SAFE 2 PHOT / PHOT TEST / PHOT OP / PHOT OP TEST / PHOT CL / PHOT CL TEST / BAR / BAR TEST / BAR OP / BAR OP TEST / BAR CL / BAR CL TEST
Refer to the “Safety input configuration” table.

10 BOTTICELLI SMART BT A 850-1250


D813948 03A00_04
START-UP
M

OK
3

1 *
2
* *

PH2
4,2
13

4
*supplied with the rail
auto . . . . . . . . . . . . . . . . . .
5s

fast
KO

fast

WARNING!! Check that the force of impact measured at the points provided for by standard EN 12445 is lower than the value laid
down by standard EN 12453.
Warning!! While the autoset function is running, the obstacle detection function is not active. Consequently, the installer must monitor
the automated system’s movements and keep people and property out of range of the automated system.

12 BOTTICELLI SMART BT A 850-1250


D813948 03A00_04

MANUAL TRANSMITTER PROGRAMMING


H
N
<10 s <10 s
2s
o o o o o 1CH=0

<10 s <10 s
2s o o o o o

REMOTE TRANSMITTER PROGRAMMING


O
H

transmitter already memorized transmitter to be memorized

1 2 3 4 5 6 7
10 s 10 s

TRANSMITTERS CANCELLATION
H
P
5s
prg

Cancellation in progress Cancellation completed

BOTTICELLI SMART BT A 850-1250 - 13


D813948 03A00_04
ACCESSENGLISH
MENUS Fig. 2

x2 *** Password entry.


Request with Protection Level
*** 0--- 10-- 150- 1520 ok
logic set to 1, 2, 3, 4

See PARAMETERS MENU Scroll up


Scroll down
Confirm/Switch on display

Exit Menù
See LOGIC MENU

See RADIO MENU

Add. 1ch hidden butt release desired button • Opening command


• ≥ 2 sec Manual transmitter programming as start
Add. 2ch hidden butt release desired button

Add. 3ch hidden butt release desired button


• Closure command
• ≥ 2 sec Manual transmitter programming as 2nd radio chan-
Add. 4ch hidden butt
nel
release desired button

erase 64
• ≥ 5 sec Cancellation of remote controls
ok If cancelled
erase 1 ( 0001 ) KO If not present
dis If clone, it is disabled
• Access menu
• ≥ 5 sec menu autoset

Diagnostics DESCRIPTION NOTES


code
STRE START E external start input activated
STRI START I internal start input activated
OPEN OPEN input activated
CLS CLOSE input activated
PED PED pedestrian input activated
TIME TIMER input activated
language STOP STOP input activated
PHOT PHOT photocell input activated
PHOP PHOT OP opening photocell input activated
PHCL PHOT CL closing photocell input activated
BAR BAR safety edge input activated
BARc Activation of edge input in BARC closure
BARo Activation of edge input in BARO opening
SWC SWC motor closing limit switch input activated
SWO SWO motor opening limit switch input activated
The board is standing by to perform a complete opening-
closing cycle uninterrupted by intermediate stops in
SET order to acquire the torque required for movement.
WARNING! Obstacle detection not active
autoset ER01 Photocell test failed Check photocell connection and/or logic settings
ER02 Safety edge test failed Check safety edge connection and/or logic settings
Check photocell connection and/or parameter/
ER03 Opening photocell test failed logic setting
Check photocell connection and/or parameter/
ER04 Closing photocell test failed logic setting
Check safety edge connection and/or parameter/
er06 8k2 safety edge test failed logic settings
- Check connections to motor
ER1x* Board hardware test error - Hardware problems with board (contact techni-
cal assistance)
ER3x* Reverse due to obstacle - Amperostop Check for obstacles in path
Control unit
software version ER4x* Thermal cutout Allow automated device to cool
stat vers OK bft . . . Try switching the board off and back on again.
ER70-ER71 Internal system supervision control error. If the problem persists, contact the technical as-
+/- ER74-ER75 sistance department.
- + No total manoeuvres(in hundreds) Pressing OK the detected settings are confirmed. The
n. cycles OK 0000 Consistency error of the control unit’s parameters (Logics board will keep on working with the detected settings.
+/-
ER72 and Parameters) The board settings must be checked (Parame-
ters and Logics)
- +
No radio controldevices memorised Pressing OK, the board will keep on working with
n. remotes OK 00 ER73 D-track parameter error D-track as a default.
+/- An autoset is required
- + Autoset not correctly performed due to intervention of
List of last 30 errors
01 external commands. Repeat the procedure
err OK 01.33

02.01 02 Travel less than the minimum required travel, about 50 cm.
The installation is too "resilient/oscillating". Tighten it by
........ 03 adding a mechanical stop to the closure limit-switch (kit
code I100025 10005) before performing a further autoset.
30.15
+/-
* X = 0,1,…,9,A,B,C,D,E,F

password 0--- 10-- 150- 1520 prg

20 BOTTICELLI SMART BT A 850-1250


D813948 03A00_04

ENGLISH

TABLE “A” - PARAMETERS MENU - (PARA )

Parameter min. max. Default Personal Definition Description

Automatic closing
TCA 0 180 40 Waiting time before automatic closing.
time [s]
Lighting time of the Lighting time of the courtesy light [s] Activation time of the courtesy light on the board
t.light 30 300 90 courtesy light [s]

output 1 240 10 Activation time of


time the timed output [s] Activation length of timed radio channel output in seconds

Slow-down distance for motor(s) during opening, given as a percentage of total travel.
OP.DIST. Slow-down distance WARNING: Once the parameter has been edited, a complete uninterrupted opening-
7 99 7
SLOUD during opening [%] closing cycle is required.
WARNING: when the display reads “SET”, obstacle detection is not active.
Slow-down distance for motor(s) during closing, given as a percentage of total travel.
CL.DIST. Slow-down distance WARNING: Once the parameter has been edited, a complete uninterrupted opening-
7 99 7 during closing [%] closing cycle is required.
SLOUD
WARNING: when the display reads “SET”, obstacle detection is not active.

PARTIAL 1 99 20 Partial opening [%] Partial opening distance as a percentage of total opening following activation of PED pedestrian
OPENING command.
Force exerted by leaf/leaves during opening. This is the percentage of force delivered, beyond
the force stored during the autoset cycle (and subsequently updated), before an obstacle alarm
is generated.
Leaf force during
OP.FORCE 1   99 75 opening [%] The parameter is set automatically by the autoset function.
WARNING: It affects impact force directly: make sure that current safety requirements
are met with the set value (*). Install anti-crush safety devices where necessary (**).

Force exerted by leaf/leaves during closing. This is the percentage of force delivered, beyond the
force stored during the autoset cycle (and subsequently updated), before an obstacle alarm is
generated.
Leaf force during
CLS.FORCE 1  99   75 closing [%] The parameter is set automatically by the autoset function.
WARNING: It affects impact force directly: make sure that current safety requirements
are met with the set value (*). Install anti-crush safety devices where necessary (**).

Percentage of maximum speed that can be reached by motor(s) during opening. WARNING: Once
OP SPEED 25 99   99 Opening speed [%} the parameter has been edited, a complete uninterrupted opening-closing cycle is required.
WARNING: when the display reads "SET", obstacle detection is not active.
Percentage of maximum speed that can be reached by motor(s) during closing. WARNING: Once
CL SPEED  25  99 45 Closing speed [%] the parameter has been edited, a complete uninterrupted opening-closing cycle is required.
WARNING: when the display reads "SET", obstacle detection is not active.
Programming num-
ber of operations
Mainte- 0 250 0 for maintenance Allows you to set a number of operations after which the need for maintenance will be reported
nance on the AUX output configured as Maintenance or Flashing Light and Maintenance .
threshold
[in hundreds]

(*) In the European Union, apply standard EN 12453 for force limitations, and standard EN 12445 for measuring method.
(**) Impact forces can be reduced by using deformable edges.

TABLE “B” - LOGIC MENU - (logic)


Cross
out
Logic Definition Default Optional extras
setting
used
Automatic 0 Logic not enabled
TCA 0
Closing Time 1 Switches automatic closing on

step-by-step mov.
Inputs configured as Start E, Start I, Ped oper- 3 STEP 4 STEP
0 ate with 4-step logic.
CLOSED OPENS
OPENS
STEP-BY-STEP Step-by-step 0 DURING CLOSING STOPS
MOVEMNT movement
OPEN CLOSES CLOSES
Inputs configured as Start E, Start I, Ped oper-
1 ate with 3-step logic. Pulse during closing DURING OPENING STOP + TCA STOP + TCA
reverses movement.
AFTER STOP OPENS OPENS

Movement on 0 Logic not active


sw mov 0
endstop 1 Activates the movement reversing when it stops on the endstop
0 The flashing light comes on at the same time as the motor(s) start.
PRE-ALARM Pre-alarm 0
1 The flashing light comes on approx. 3 seconds before the motor(s) start.
Block pulses 0 Pulse from inputs configured as Start E, Start I, Ped has effect during opening.
IBL OPEN 0
during opening 1 Pulse from inputs configured as Start E, Start I, Ped has no effect during opening.

BOTTICELLI SMART BT A 850-1250 - 21


D813948 03A00_04
ENGLISH

Cross
out
Logic Definition Default Optional extras
setting
used
0 Input configured as Phot (photocell).
Configuration 1 Input configured as Phot test (tested photocell).
of safety input
SAFE 1 6
SAFE 1.
72 2 Input configured as Phot op (photocell active during opening only).

3 Input configured as Phot op test (tested photocell active during opening only).

4 Input configured as Phot cl (photocell active during closing only).

5 Input configured as Phot cl test (tested photocell active during closing only).

6 Input configured as Bar, safety edge.

7 Input configured as Bar, tested safety edge.

8 Input configured as Bar 8k2. (Inactive on SAFE 2).

9 Input configured as Bar OP, safety edge with inversion active only while opening. If while closing, the movement stops.
Configuration Input configured as Bar OP TEST, safety edge tested with inversion active only while opening. If while closing, the
of safety input 10
SAFE 2 4 movement stops.
SAFE 2.
73 Input configured as Bar OP 8k2, safety edge with inversion active only while opening. If while closing, the movement
11 stops. (Inactive on SAFE 2).
12 Input configured as Bar CL, safety edge with inversion active only while closing. If while opening, the movement stops.
Input configured as Bar CL TEST, safety edge tested with inversion active only while closing. If while opening, the
13 movement stops.
Input configured as Bar CL 8k2, safety edge with inversion active only while closing. If while opening, the movement
14 stops. (Inactive on SAFE 2).
15 Not used

16 Input configured as STAR 8k2. (Inactive on SAFE 2).

0 Input configured as Start E.


Configuration of 1 Input configured as Start I.
command input
IC 1 0
IC 1.
61 2 Input configured as Open.

3 Input configured as Close.

4 Input configured as Ped.


Configuration of
command input
IC 2 4 5 Input configured as Timer.
IC 2.
62
6 Input configured as Timer Pedestrian.

Configuration 0 Radio control configured as START E.


of the 1st radio
1ch 0 1 Radio control configured as Start I.
channel com-
mand 2 Radio control configured as Open.
Configuration 3 Radio control configured as Close
of the 2nd
2ch radio channel 12 4 Radio control configured as Ped
command 5 Radio control configured as STOP
Configuration 6 Not used
of the 3rd radio
3 ch channel com- 9 7 Not used
mand 8 Not used
9 Radio control configured as AUX3 **
Configuration
of the 4th radio 10 Radio control configured as EXPO1 **
4 ch channel com- 4
11 Radio control configured as EXPO2 **
mand
12 Radio control configured as COURTESY LIGHT
0 Output configured as monostable Radio Channel.
1 Output configured as SCA (gate open light).
2 Output configured as Courtesy Light command.
3 Not used
4 Not used
5 Not used
6 Not used
7 Not used
Configuration of
AUX 3 AUX 3 output. 0 8 Not used
26-37
9 Output configured as Maintenance
10 Not used
11 Not used
12 Not used
13 Output configured as closed Gate Status
14 Output configured as Bistable Radio Channel
15 Output configured as timed Radio Channel
16 Output configured as open Gate Status

22 BOTTICELLI SMART BT A 850-1250


D813948 03A00_04

ENGLISH

Cross
out
Logic Definition Default Optional extras
setting
used
Receiver is configured for operation in rolling-code mode.
0 Fixed-Code Clones are not accepted.
FIXED CODE Fixed code 0
Receiver is configured for operation in fixed-code mode.
1 Fixed-Code Clones are accepted.
A - The password is not required to access the programming menus
B - Enables wireless memorizing of transmitters.
Operations in this mode are carried out near the control panel and do not require access:
- Press in sequence the hidden key and normal key (T1-T2-T3-T4) of a transmitter that has already been memori-
zed in standard mode via the radio menu.
- Press within 10 sec. the hidden key and normal key (T1-T2-T3-T4) of a transmitter to be memorized.
The receiver exits programming mode after 10 sec.: you can use this time to enter other new transmitters by
0 repeating the previous step.
C - Enables wireless automatic addition of clones.
Enables clones generated with the universal programmer and programmed Replays to be added to the recei-
ver’s memory.
D - Enables wireless automatic addition of replays.
Enables programmed Replays to be added to the receiver’s memory.
E - The board’s parameters can be edited via the U-link network
A - You are prompted to enter the password to access the programming menus
1 The default password is 1234.
No change in behaviour of functions B - C - D - E from 0 logic setting
Protection Setting the 0
A - You are prompted to enter the password to access the programming menus
level protection level The default password is 1234.
2 B - Wireless memorizing of transmitters is disabled.
C - Wireless automatic addition of clones is disabled. No change in behaviour of functions D - E from 0 logic
setting
A - You are prompted to enter the password to access the programming menus
The default password is 1234.
3 B - Wireless memorizing of transmitters is disabled.
D - Wireless automatic addition of Replays is disabled.
No change in behaviour of functions C - E from 0 logic setting
A - You are prompted to enter the password to access the programming menus
The default password is 1234.
B - Wireless memorizing of transmitters is disabled.
C - Wireless automatic addition of clones is disabled.
4 D - Wireless automatic addition of Replays is disabled.
E - The option of editing the board’s parameters via the U-link network is disabled.
Transmitters are memorized only using the relevant Radio menu.
IMPORTANT: This high level of security stops unwanted clones from gaining access and also stops radio interfe-
rence, if any.
Serial mode 0 Standard SLAVE: board receives and communicates commands/diagnostics/etc.
(Identifies how
board is con-
SERIAL MODE 0
figured in a BFT
network 1 Standard MASTER: board sends activation commands (START, OPEN, CLOSE, PED, STOP) to other boards.
connection).
Identifies board address from 0 to 119 in a local BFT network connection.
ADDRESS Address 0 [ ___ ] (see U-LINK OPTIONAL MODULES section)
Reversing During closure, after an obstacle is detected, the movement gets reversed for 2 seconds.
0 During opening, after an obstacle is detected, the manoeuvre gets interrupted and the automation is blocked.
op.revers.obst obstacle when 0
opening 1 Both while closing as well as opening, after an obstacle is detected, the movement gets reversed for 2 seconds.
0 Standard operation with sectional doors (General Notes Ref. Fig. 1 and 2)
brts BRTS 0
1 Operation with tip-up doors, fitted with BRTS accessory (General Notes Ref. Fig. 3)
0 Input configured as Start E command.
1 Input configured as Start I command.
2 Input configured as Open command.
3 Input configured as Close command.
4 Input configured as Ped command.
5 Input configured as Timer command.
6 Input configured as Timer Pedestrian command.
7 Input configured as Phot (photocell) safety.
8 Input configured as Phot op safety (photocell active during opening only).
Configuration
of EXPI1 input 9 Input configured as Phot cl safety (photocell active during closing only).
on input-output 10 Input configured as Bar safety (safety edge).
EXPI1 2
expansion
board. Input configured as safety Bar OP, safety edge with inversion active only while opening, if while closing the mo-
11
1-2 vement stops.
Input configured as safety Bar CL, safety edge with inversion active only while closing, if while opening the mo-
12 vement stops.
13 Input configured as Phot test safety, tested photocell.
14 Input configured as Phot op test safety, tested photocell active only while opening.
15 Input configured as Phot cl test safety, tested photocell active only while closing.
16 Input configured as Bar safety, tested safety edge.
Input configured as safety Bar OP test, safety edge with inversion active only while opening, if while closing the
17 movement stops.
Input configured as safety Bar CL test, safety edge with inversion active only while closing, if while opening the
18 movement stops.

BOTTICELLI SMART BT A 850-1250 - 23


D813948 03A00_04
ENGLISH

Cross
out
Logic Definition Default Optional extras
setting
used
0 Input configured as Start E command.
1 Input configured as Start I command.
Configuration of
EXPI2 input 2 Input configured as Open command.
on input-output
EXPI2 3 3 Input configured as Close command.
expansion
board. 4 Input configured as Ped command.
1-3
5 Input configured as Timer command.
6 Input configured as Timer Pedestrian command.
0 Output configured as monostable Radio Channel.
1 Output configured as SCA (gate open light).
2 Output configured as Courtesy Light command.
Configuration of
EXPO2 output 3 Not used
on input-output
EXPO1 13 4 Not used
expansion
board 5 Not used
4-5
6 Not used
7 Not used
8 Not used
9 Output configured as Maintenance.
10 Not used
Configuration of 11 Not used
EXPO2 output
on input-output 12 Not used
EXPO2 16
expansion 13 Output configured as Gate Status
board
6-7 14 Output configured as Bistable Radio Channel
15 Output configured as timed Radio Channel
16 Output configured as open gate Status

(**) Active only if the output is configured as Monostable Radio Channel, Courtesy Light, Zone Light, Stair Light, Bistable Radio Channel or Timed Radio Channel.

AUX output configuration


Aux logic= 0 - MONOSTABLE RADIO CHANNEL output.
Contact stays closed for 1s when radio channel is activated.
Aux logic= 1 - SCA GATE OPEN LIGHToutput.
Contact stays closed during opening and with leaf open, intermittent during closing, open with leaf closed.
Aux logic= 2 - COURTESY LIGHT command output.
Contact stays on for 90 seconds after the last operation.
Aux logic= 3 – Not used
Aux logic= 4 – Not used
Aux logic= 5 – Not used
Aux logic= 6 – Not used
Aux logic= 7 – Not used
Aux logic= 8 – Not used
Aux logic= 9 - MAINTENANCE output.
Contact stays closed once the value set for the Maintenance parameter is reached, to report that maintenance is required.
Aux logic= 10 – Not used
Aux Logic= 11 – Not used
Aux Logic= 12 – Not used
Aux logics= 13 - GATE STATUS output
Contact stays closed while gate is closed.
AUX logics= 14 - BISTABLE RADIO CHANNEL output
The contact changes status (open-closed) when the radio channel is activated
AUX logics= 15 - TIMED RADIO CHANNEL output
The contact remains closed for a programmable length of time when the radio channel is activated (output time)
If, during this time, the button is pressed again, counting starts all over again.
Command input configuration
IC logic= 0 - Input configured as Start E. Operation according to STEP-BY-STEP MOV. logic. External start for traffic light control.
IC logic= 1 - Input configured as Start I. Operation according to STEP-BY-STEP MOV. logic. Internal start for traffic light control.
IC logic= 2 - Input configured as Open.
The command causes the leaves to open. If the input stays closed, the leaves stay open until the contact is opened. When the contact is open, the automated device closes following
the TCA time, where activated.
IC logic= 3 - Input configured as Closed.
The command causes the leaves to close.
IC logic= 4 - Input configured as Ped.
The command causes the leaf to open to the pedestrian (partial) opening position. Operation according to STEP-BY-STEP. logic
IC logic= 5 - Input configured as Timer.
Operation same as open except closing is guaranteed even after a mains power outage.
IC logic= 6 - Input configured as Timer Ped.
The command causes the leaf to open to the pedestrian (partial) opening position. If the input stays closed, the leaf stays open until the contact is opened. If the input stays closed and a Start E,
Start I or Open command is activated, a complete opening-closing cycle is performed before returning to the pedestrian opening position. Closing is guaranteed even after a mains power outage.
Safety input configuration
SAFE logic= 0 - Input configured as Phot (photocell) non tested (*) .
Enables connection of devices not equipped with supplementary test contacts. When beam is broken, photocells are active during both opening and closing. When beam is broken
during closing, movement is reversed only once the photocell is cleared. If not used, leave jumper inserted.
SAFE logic= 1 - Input configured as Phot test (tested photocell).
Switches photocell testing on at start of operation. When beam is broken, photocells are active during both opening and closing. When beam is broken during closing, movement is
reversed only once the photocell is cleared.
SAFE logic= 2 - Input configured as Phot op (photocell active during opening only) non tested (*).
Enables connection of devices not equipped with supplementary test contacts. In the event beam is broken, photocell operation is disabled during closing. During opening, stops
motion for as long as the photocell beam stays broken. If not used, leave jumper inserted.
SAFE logic= 3 - Input configured as Phot op test (tested photocell active during opening only.
Switches photocell testing on at start of operation. In the event beam is broken, photocell operation is disabled during closing. During opening, stops motion for as long as the photocell beam stays broken.
SAFE logic= 4 - Input configured as Phot cl (photocell active during closing only) non tested (*) .
Enables connection of devices not equipped with supplementary test contacts. In the event beam is broken, photocell operation is disabled during opening. During closing, move-
ment is reversed immediately. If not used, leave jumper inserted.

24 BOTTICELLI SMART BT A 850-1250


D813948 03A00_04

ENGLISH

SAFE logic= 5 - Input configured as Phot cl test (tested photocell active during closing only.
Switches photocell testing on at start of operation. In the event beam is broken, photocell operation is disabled during opening. During closing, movement is reversed immediately.
SAFE logic= 6 - Input configured as Bar (safety edge) non tested (*) .
Enables connection of devices not equipped with supplementary test contacts. The command reverses movement for 2 sec.. If not used, leave jumper inserted.
SAFE logic= 7 - Input configured as Bar (tested safety edge.
Switches safety edge testing on at start of operation. The command reverses movement for 2 sec.
SAFE logic= 8 - Input configured as Bar 8k2. Input for resistive edge 8K2.
The command reverses movement for 2 sec.
SAFE logic=9 Input configured as Bar op, safety edge with active inversion only while opening, if activated while closing, the automation stops (STOP) .
Allows connecting devices not fitted with supplementary test contact. The operation while opening causes the movement to be reversed for 2 seconds, the operation while closing causes the
automation to stop. If not used, leave jumper inserted.
SAFE logic=10 Input configured as Bar op test, safety edge checked with active inversion only while opening, if activated while closing, the automation stops (STOP) .
Activates testing safety edges when starting operation. The operation while opening causes the movement to be reversed for 2 seconds, the operation while closing causes the automation to stop.
SAFE logic=11 Input configured as Bar 8k2 op, 8k2 safety edge with active inversion only while opening, if activated while closing, the automation stops (STOP)
The operation while opening causes the movement to be reversed for 2 seconds, the operation while closing causes the automation to stop.
SAFE logic=12 Input configured as Bar cl, safety edge with active inversion only while closing, if activated while opening, the automation stops (STOP).
Allows connecting devices not fitted with supplementary test contact. The operation while closing causes the movement to be reversed for 2 seconds, the operation while opening
causes the automation to stop. If not used, leave jumper inserted.
SAFE logic=13 Input configured as Bar cl test, safety edge checked with active inversion only while closing, if activated while opening, the automation stops (STOP).
Activates testing safety edges when starting operation. The operation while closing causes the movement to be reversed for 2 seconds, the operation while opening causes the automation to stop.
SAFE logic=14 Input configured as Bar 8k2 cl, safety edge with active inversion only while closing, if activated while opening, the automation stops (STOP) .
The operation while closing causes the movement to be reversed for 2 seconds, the operation while opening causes the automation to stop.
Logica SAFE= 15 - Non utilisé
Logica SAFE=16 - Input configured as STOP 8k2. The command interrupts the maneuver and blocks the automation.
(*) If “D” type devices are installed (as defined by EN12453), connect in unverified mode, foresee mandatory maintenance at least every six months.

Radio channel control configuration


CH logic= 0 - Control configured as Start E. Operation according to STEP-BY-STEP MOV. logic. External start for traffic light control.
CH logic= 1 - Control configured as Start I. Operation according to STEP-BY-STEP MOV. logic. Internal start for traffic light control.
CH logic= 2 - Control configured as Open.
The command causes the leaves to open.
CH logic= 3 - Control configured as Closed.
The command causes the leaves to close.
CH logic= 4 - Control configured as Ped.
The command causes the leaf to open to the pedestrian (partial) opening position. Operation according to STEP-BY-STEP. logic
Logica CH= 5- Control configured as STOP.
The command performs a STOP
CH logic= 6 - Control configured as AUX0. (**)
The control activates the AUX0 output
CH logic= 7 - Not used
CH logic= 8 - Not used
CH logic= 9 - Control configured as AUX3. (**)
The control activates the AUX3 output
CH logic= 10 - Control configured as EXPO1. (**)
The control activates the EXPO1 output
CH logic= 11 - Control configured as EXPO2. (**)
The control activates the EXPO2 output
(**) Active only if the output is configured as Monostable Radio Channel, Courtesy Light, Zone Light, Stair Light, Bistable Radio Channel or Timed Radio Channel.

TABLE “C” – RADIO MENU (RADIO)


Logic Description
Add 1ch Key
add 1ch associates the desired key with the 1nd radio channel command.
Add 2ch Key
add 2ch associates the desired key with the 2nd radio channel command.
Add 3ch Key
add 3ch associates the desired key with the 3nd radio channel command.
Add 4ch Key
add 4ch associates the desired key with the 4nd radio channel command.
Erase List
erase 64 WARNING! Erases all memorized transmitters from the receiver’s memory.

Eliminates individual radio control


erase 1 Removes a radio control (if clone or replay is disabled) To select the radio control to be deleted, enter the position or press a button on the radio
control to be deleted (the position is displayed)
Read receiver code
Displays receiver code required for cloning transmitters.

BOTTICELLI SMART BT A 850-1250 - 25


D813948 03A00_04
ENGLISH

TECHNICAL SPECIFICATIONS
ELECTRICAL DATA
Power supply 220-230V 50/60Hz
BOTTICELLI SMART BT A 850: 200W
Max. power absorbed from mains
BOTTICELLI SMART BT A 1250: 250W
Fuses see figure L-S
24V~ (180mA max)
Supply to accessories
24Vsafe (180mA max)
Blinker connection 24V~ max 25W
Courtesy light BFT model courtesy LED lamp 24V 2W
Operating temperature -20°C / +60°C

MECHANICAL DATA
BOTTICELLI SMART BT A 850: 850N
Pulling and pushing force
BOTTICELLI SMART BT A 1250: 1250N
BOTTICELLI SMART BT A 850 : 13m2
Leaf max.
BOTTICELLI SMART BT A 250 : 16m2
TRACK L.=2900 working stroke=2300 mm
Working stroke
TRACK L.=3500 working stroke=2900 mm
Belt track= 240
BOTTICELLI SMART BT mm/s
A 850 Chain track= 210
Maximum speed mm/s
BOTTICELLI SMART BT Chain track= 190
A 1250 mm/s
Manoeuvres in 24 hours@ BOTTICELLI SMART BT A 850: 50
MAX+60°C BOTTICELLI SMART BT A 1250: 100
Manoeuvres in 1 hour@ MAX+50°C 10
Typical instal- 100 consecutive ma-
BOTTICELLI SMART BT A 850: mq 6,7
lation of sec- noeuvres
tional doors
BOTTICELLI SMART BT A 1250: mq 15,7 50 consecutive ma-
at 20°C noeuvres
Impact reaction integrated torque limiter on control panel
Limit switch Electronic with ENCODER
Lubrication permanent grease
Degree of protection IP20
Motor head weight 5 kg
Noise level <70dB(A)
Dimensions see fig.B

INCORPORATED RECEIVER DATA


Incorporated rolling-code
Frequency 433.92 MHz
radio receiver

Coding rolling-code algorithm

No. combinations 4 billion


Max no. radio controls to be
63
memorised
ACTUATOR INSTALLATION Fig.A
Arrange for the connections of accessories and safety and control devices to reach
the motor unit, keeping the mains voltage connections clearly separate from the
extra low safety voltage connections (24V).
Proceed to connection following the indications given in the wiring diagram.
The cables for connecting the accessories must be protected by a raceway

Preliminary checks
• Check that the door is balanced.
• Check that the door slides smoothly along its entire travel.
• If the door has not been newly installed, check the wear condition of all its
components.
• Repair or replace faulty or worn parts.
• The automation reliability and safety are directly influenced by the state of
the door structure.
• Before fitting the motor, remove any superfluous ropes or chains and disable
any unnecessary appliances.

50 BOTTICELLI SMART BT A 850-1250


D813948 03A00_04

USER’S MANUAL: MANUAL OPERATION


R

K
CLIC

FUSE REPLACEMENT
S

1 2

PH2

T ACCESSORIES
SET/S ST BT BAT
SM1 S
External release device Automatic bolt release device for spring-operated
with retracting handle for over-head doors. Fitted to the control arm, it Kit battery charger.
automatically releases the side door bolts.
External release device to be applied to the cre- sectional doors measuring
mone bolt already fitted to the overhead max 50mm.
door.

BOTTICELLI SMART BT A 850-1250 - 53