0% found this document useful (0 votes)
2K views26 pages

PK300DC PK350DC English User Manual - Id200 - Standard Version

This document provides installation instructions for a swing gate opener model PK300DC/PK350DC. It includes: 1. A list of included parts such as the main engine, manual release bar, remote control, and mounting hardware. 2. Technical specifications for the gate opener including power requirements, speed, weight and size limits. 3. A diagram illustrating typical installation locations for the main components. 4. Step-by-step instructions for preparing the gate and mounting the main engine and brackets to ensure proper installation.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
2K views26 pages

PK300DC PK350DC English User Manual - Id200 - Standard Version

This document provides installation instructions for a swing gate opener model PK300DC/PK350DC. It includes: 1. A list of included parts such as the main engine, manual release bar, remote control, and mounting hardware. 2. Technical specifications for the gate opener including power requirements, speed, weight and size limits. 3. A diagram illustrating typical installation locations for the main components. 4. Step-by-step instructions for preparing the gate and mounting the main engine and brackets to ensure proper installation.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 26

PK300DC/PK350DC

Swing Gate Opener


User Manual
Dear users,
Thank you for choosing this product. Please read the manual carefully before assembling and using it.
Please do not leave out the manual if you send this product to a third party.

1. Safety Instruction

Please ensure that the using power voltage matches with the supply voltage of gate opener

(AC110V or AC220V); kids are forbidden to touch the control devices or the remote-control unit.

The remote-control unit is controlled by a single button mode or three button mode (please refer to

the instructions of the remote control in accordance with the actual gate opener type). The indicator

light on the remote-control unit will flicker when the button on it is pressed. Main engine and gate

can be unlocked by disengagement wrench and the gate can move with manual operation after

disengagement.

Please ensure that no one is around the main engine or gate when the switch is operated and it is

usually demanded to examine the stability of installation. Please temporarily stop using if the main

engine needs repairing or regulation.

The installation and maintenance of the products must be carried out by professionals.

1
2. Packing List (standard)
No. Picture Name Quantity

1 Main engine 2

2 Manual release bar 1

A A
B B
3 C C Remote control 2
D D

4 Control box 1

5 Wall bracket 4

6 Front mounting bracket 2

7 Connecting bracket 2

8 Mounting screw (short) 2

9 Mounting screw (length) 2

10 Screw M8×25 4

11 Nut M8 8

2
No. Picture Name Quantity

12 Limit stopper 1

2. Packing list (optional)


No. Picture Name Quantity

1 Infrared sensor 1

1 2 3
4 5 6

2 7 8
0
9

Wireless keypad 1

3 Alarm lamp 1

4 Electronic lock 1

5 Storage battery 2

3. Technical parameters
Model PK300DC PK350DC
Power supply 220V/50Hz;110V/60Hz 220V/50Hz;110V/60Hz
Motor power 80W 80W
Gate moving speed 18~22 second per 90 (approx) 18~22 second per 90 (approx)
Max.single-leaf weight 300Kg 300Kg
Max.single-leaf length 2.5M 3.0M
Max.piston stroke: 34cm 54cm
Max.force 1500N 1500N
Remote control distance ≥30m ≥30m
Remote control mode Single button mode Single button mode
Storage battery (optional) 24V or 12 VDC 24V or 12 VDC
Noise ≤58dB ≤58dB
Working duty S2, 30min S2, 30min
Recording of up remote controls 25 25
Frequency 433.92 MHz 433.92 MHz

3
Working temperature -20°C - +70°C -20°C - +70°C
Package weight 17Kg 19Kg

4. Installation
PK300DC/PK350DC swing gate opener is applicable to single leaf gate weight less than 300kg, and
length of the single leaf swing gate should be less than 2.5m/3m. The drive mode adopts the worm
and worm gear to combine the screw rod transmission. This gate opener must be installed inside
the enclosure or yard for protection.

4.1 Installation drawing

① ② 1

4
7
2

5
8
0
3

6
9







A
B
C
D

Figure 1
①Control box; ②Gate opener; ③Gate; ④Alarm lamp (optional);
⑤Infrared sensor (optional); ⑥Stopper; ⑦Remote control; ⑧Wireless keypad (optional);

4.2 Size of main engine and accessories


4.2.1 Size of main engine

4
620Min

970Max

104
190
PK300DC

820Min

1370Ma x
104
190

PK350DC

Figure 2

5
4.2.2 Size of mounting plate

8.5

17.5
70
40
2 ×φ8 . 5

43
Front mounting bracket Wall bracket

Figure 3
4.3 Installation steps
4.3.1 Preparation before main engine installation
a) Before installing the door opener, please confirm the correct installation of the door to ensure that
the door can be easily manually operated, and the door safety stopper can effectively prevent the
door to continue moving.
b) Install the electric lock, the distance between the door bottom and ground should be 40-50mm. If
not install the electric lock, the distance between door bottom and ground should be ≥20mm;
c) The main engine recommended mounting height is about 300 ~ 800mm from the ground, and
make sure there are reliable fixed points for mounting brackets.

Cable
In order to ensure the normal operation of the door opener and protect the cable from damage,
please use PVC pipe laying motor, power cable, and control cables, and separate two PVC pipes to
lay (motor and power cable) and (control cable), respectively.

Mounting brackets
In order to install the PK300DC / PK350DC main engines firmly, recommend to use the expansion
screws to fix the mounting brackets.

4.3.2 Accessory
a) Before installing the main engine, install the wall bracket on the wall, then fix the connecting
bracket, and install the front mounting bracket on the door.
Note: Please detect by gradienter before fixing, to ensure that the front mounting bracket
and the connecting bracket in the same level.

6
Hexagon screw

Expansion screw Hexagon screw

Nut Nut

Figure 4
b) The connecting bracket and the wall bracket can be connected according to different conditions,

as shown in figure 5.

Figure 5
c) Users shall prepare power cables for the control box and main engines, according to different
installation environment, the power cable of the control box is not less than 3 cores, and the power

cable of the control box with 2 cores. If you need to install electric locks, infrared sensor, alarm lamp,

external button switch and other external equipment, please increase corresponding the embedded

wire, and the sectional area of electric lock cable core shall not be lower than 1.5mm², others shall

not be lower than 0.5mm². The length is determined by the user of according to the situation in the

installation site.

Note: The pipe outlet should be facing down to avoid rain water entering the pipe along the cable.

d) Before the installation, please unlock the main engine. Method: Remove the cover, insert the

manual release bar, rotate the bar until the release, as shown in Figure 6, then turn the telescopic

arm to make it easily stretch.

7
Left engine Right engine

Figure 6

4.3.3 Main engine installation


As shown in Figure 7, the tail of the main engine and the connecting bracket are fixed together
through the installation of screws, and then manually adjust the telescopic arm to the appropriate
length, and finally fix the telescopic arm connector and the front mounting bracket with the
installation screws. Pull the door after the completion of the installation to ensure the entire process
flexible without jamming.

Mounting screw (length)

Mounting screw (short)


Nut

Nut

Figure 7
8
Installation direction: door open facing inward (PK300DC)
Note: Limit stopper must be installed
B

L=620+5
L

K<620+340

Figure 8

100 110 120 130 140 150 160 170 180 190 200
B
100
110
120
130
140 Max 120°
150
160 Max 110°
170
180 Max 100°
190
200
Max 90°

mm

A
Figure 9
Note: Value B must be close to or equal to the value A to obtain the best mechanical
advantage.
9
Installation direction: door open facing outward (PK300DC)

Note: Safety stopper must be


installed, is provied by installer

L=620+5
K<620+340

K
B

A L
Note: Limit stopper must be installed

Figure 10

100 110 120 130 140 150 160 170 180 190 200
B
100
110
120
130
140
150 Max 90°
160
170 Max 100°
180
190 Max 110°
200
Max 120°
mm

A
Figure 11
Note: Value B must be close to or equal to the value A to obtain the best mechanical
advantage.
Installation direction: door open facing inward (PK350DC)
10
Note: Limit stopper must be installed
B

A
K

L=820+10
L

K<820+540

Figure 12

100 120 140 160 180 200 220 240 260 280 300
B
100
120
140 Max 120°
160
180 Max 110°
200
220 Max 100°
240
260 Max 90°
280
300

mm

A
Figure 13
Note: Value B must be close to or equal to the value A to obtain the best mechanical
advantage.
Installation direction: door open facing outward (PK350DC)
11
Note: It is recommended to install
with a safety stopper
(should be prepared by the users
themselves)

K
L=820+10
B K<820+540

A L

Note: Limit stopper must be installed


Figure 14

100 120 140 160 180 200 220 240 260 280 300
B
100
120
140
Max 90°
160
180
Max 100°
200
220
Max 110°
240
260
Max 120°
280
300

mm

A
Figure 15
Note: Value B must be close to or equal to the value A to obtain the best mechanical
advantage.
4.3.4 Size of control box

12
275
210 127.5

Figure 16

Warnings
·To ensure safety, when door open facing outward, the safety block must be installed at the OPEN
limit position to prevent the door opening angle from exceeding the machine range; the safety
stopper must be installed at the CLOSE limit position, to make two doors stopping at the CLOSE
limit position accurately (as shown in figure 10, 14). When door open facing inward, the safety
stopper must be installed at the CLOSE limit position (as shown in figure 8, 12).
·Before installing the main engine, make sure that the main engine and components are in good
mechanical performance and that the door can be operated manually.
·One control unit can control driving one main engine or two main engines.
·Earth leakage circuit breaker must be installed where the gate movement can be seen, and the
minimum mounting height of control box is 1.5m to protect it from being touched.
·After installation, please check whether the mechanical property is good or not, whether gate
movement after manual unlocking is flexible or not, and whether the infrared sensor (optional) is
installed correctly and effectively.

13
4.3.5 Control board wiring

Figure 17

1.Antenna
2. Antenna's shield
3. Start input (NO)
It completely opens the gate
4. Pedestrian start in. (NO)
It opens just motor 2
5. Common

14
6. Photocell input (NC)
During pause: Reloads pause
During closing: Reverses motors direction
7. Photo stop input (NC)
During pause: Reloads pause.
During closing: Reverses motors direction.
During opening: stops the motors and waits till contact returns close.
8. Analog opening edge input (8K2 ohm)
Waiting an opening command: inhibits opening
During opening: reverses motor direction for 1 second.
If not used left unconnected.
9. Analog closing edge input (8K2 ohm)
Waiting a closing command: inhibits closing.
During closing: reverses motor direction for 1 second.
If not used left unconnected.
10. Common
11. Stop input (NC)
It always stops motors and blocks control unit activity.
12. Common
13-14. Power supply output
12Vdc 250mA
15-16. Electric lock output
17-18. Flashing light output
12/24V 1A
19-20. Output motor 1
8A
21-22. Output motor 2
8A
TR1. Slowing down speed trimmer
TR2. Obstacle detection sensibility trimmer.
TS1-TS3. Buttons up/down
TS2. Enter button
DSP. Display
FS3-FS4. Transformer input 12-20Vac / 100-200VA
F2. Battery fuse 10A Fast
FS1-FS2. Backup battery input 12/24Vdc
J1. Back up battery voltage selector 12/24V

15
Inputs status
When the control unit is in standby. User can read inputs status on display:
_ _: No input active.
5t: Stop input active.
P5: Photo stop input active.
Pc: Photocells input active.
EO: Analogic edge opening input active.
EC: Analogic edge closing input active.
5B: Start input active.
5p: Pedestrian input active.
op: Open input active.
CL: close input active.

During pause, the display show the seconds countdown to closing.

Trimmers setting
Slow down speed trimmer regulates the slowdown speed. Do not set speed to low(less than 10
cm/sec on the wing edge) to avoid that gate stops in too cold conditions.

Obstacle sensibility trimmer fine tunes the obstacle detection level learned by the control unit
during working times programming .This fine regulation must be do after working times learning.
Normally the trimmer goes in the center, in this position should be possible to respect rules in most
of installations. If it’s need to resolve problems related to norms or to environmental situations (ex.
Strong wind) is it possible to regulate this trimmer increasing or decreasing sensibility.

Figure 18

Quick installation
To program quickly the working times, open both wings, then keep pushed up till you read AU on
the display. The control unit will do several tests an than it’ll learn working times. When the
procedure is finish the blinker goes off.

Auto Learning transmitters:


It’s possible to learn transmitters quickly without using the base menu. To insert a new transmitter
transmit3 times with the new remote, making at least 1 second pause between each transmission.
16
Than transmitter already in memory and then once with the new. When programmation is done, the
blinker flash once. Attention: function must be enabled, refer to “advance menu ”-auto learning
transmitters. The new code takes the same channel as the one used to insert it.

Board settings
Base Menu
Push enter 1 for at least 1 second to enter base menu.
OL is on the display, with up/down it’s possible to select other functions of this menu.
To exit this menu select EX or push up and down together.
After 2 minutes without actions, the control unit exits itself from this menu.

Figure 19

17
Base Menu description:
Operating logic OL:
Select OL and push enter, with up/down select wanted logic between following end push once
enter. Check tab operating logic for further information.
5T: Step by step logic.
At: Automatic closing with stop function.
CD: Automatic closing for condominium function.
To exit this menu select EX or push up/down together.

LC Learning/ removing transmitters code:


Select learning code function LC and push enter, than select one of following functions with
up/down.
C1: learn a transmitter on channel1.
C2: learn a transmitter on channel2.
Rt: Delete all transmitter in memory.
Once selected the channel transmit the code, on the display is show “OK” for a while if operation is
done.
To replace the channel of a code, just select desired channel and transmit once the same code.
To delete just one code, select RT and transmit the code to be removed, on the display is show
“OK” for a while if operation is done.
To delete all codes, select RT and push enter, then confirm with YS.
To exit this menu select EX or push up/down together.

LT learn working time:


Attention: before to start learning procedure, the gate must be open to do automatic procedure,
otherwise must be closed to do the manual procedure. Use “dead man ” function to put the gate in
the right position.
Is it possible to program working time automatically, please refer to “Quick installation”
Select LT in the base menu and push enter, after select the learning mode with up/down.
AU: automatic learning procedure.
MN: Manual learning procedure.
To exit this menu select EX or push up/down together.

AU: Automatic procedure for working times learning.


Attention: in this procedure all safety inputs are disabled.
The wings close themselves, in the meanwhile all the working times and values for obstacle
detection sensor are learned. If just motor 2 is connected, the control unit sets itself for “single wing
working”. If analogue edges are connected, they are automatically enabled.

5p Set pause times:


Use up/down to set the pause time between 0 and 99 seconds. Push enter to confirm. To exit
without modifications push together up and down.
Attention: setting pause time doesn’t enable auto closing, please refer to chapter “OL operating
logic” to enable this function.

18
DM Dead man mode:
Selecting this menu it’s possible to control each motor in dead man mode. Push up and down to
select one of following item:
O1 open motor1
C1 close motor1
Q1 open motor2
C2 close motor2
EX Exit

Keep pushed enter to start the selected motor in dead man mode.

Board settings:
Advanced Menu
Push enter button till on the display is shown TM. With up/down it’s possible to select all items
In this menu.
To exit this menu select EX or push up/down together.
After 2 minutes without actions, control unit exits itself from this menu.

19
Figure 20

Advanced menu
TM working times menu:
In this menu it’s possible to modify working times of control unit:
T1- Working time motor1
51- Start time slowdown motor1
T2- Working time motor2
52- Start time slowdown motor2
DO-Motors delay opening
DC- Motors delay closing
TL-Electric lock activation menu.
EX-Exits from advanced menu.
Once selected working times to be changed, use up/down to modify it from 0 to 99 seconds. Push
enter to confirm.
To exit without modifications select EH or push together up and down.

5G Single wing mode:


In this menu it’s possible to verify or set if gate works in single wing mode (motor2).Use up/down to
choose yes (YS), not (NT) or exit(EX). Push enter to confirm.

20
D2 Load defaults:
Choosing this menu and confirming with yes (YS), set the control unit at factory defaults.

RC release torque at work end:


Enabling this function, the motors reverse direction for a while to release the torque at end of
work .Use up/down to choose yes(YS),not (NT) or exit(EX). Push enter to confirm.

EO Enable opening analogue edge:


Enabling this function it’s enabled the edge active in opening period. Choose yes(YS) is enables the
edge.
EC Enable closing analogue edge:
Enabling this function it’s enabled the edge active in closing period. Choose yes(YS) is enables the
edge.
Ar Enable automatic transmitters learning:
Enabling this function it’s possible to insert new transmitters without accessing base menu. Refer to
“Automatic transmitters learning”.

C5 Enable kickback stroke:


In this menu you can enabled the stroke at start to unlock electric lock and the final stroke to lock it.

rM Radio mode:
In this menu it’s possible to modify how transmitters work with the control unit.
5T- Step by step mode: Each button (code) of the transmitter is entered separated by the others,
Codes learned on C1 work as “Start command”. Transmitters learned on C2 word as “Pedestrian
command”.
r1- Learning a code from a transmitter, it enables all the four buttons of transmitter wording with the
control unit. Sequence is: Button1=open command, Button2=close commend, Button3=Pedestrian
commend, Button 4=stop commend.
r2- Learning a code from a transmitter, it enables all the four buttons of transmitter wording with the
control unit. The sequence is as above, except buttons3 and 4 inverted.

21
Default settings (Factory presets)
Herr it follows list default settings. The same set after a D2 command of advanced menu.

Figure 20

22
5. Others
5.1 Maintenance
Check whether the gate operates normally every month.
For the sake of safety, each gate is suggested to be equipped with infrared protector, and regular
inspection is required.
Before installation and operation of the gate opener, please read all instructions carefully.
Our company has the right to change the instruction without prior notice.

23
5.2 Troubleshooting

Problems Possible Reasons Solutions


1.Switch on the power
1.The power is off. supply.
The gate cannot open
2.Fuse is burned. 2.Check the fuse, change the
or close normally, and
3.Control board power wiring fuse if burnt.
Display does not light.
with problem. 3.Re wiring according to
instructions.
1.If not connect photocell ,
please make sure that the 5
and 6, 5 and 7short circuit;
1.Photocell wiring with problem. if connect infrared sensor,
2.Photocell mounting with please make sure the wiring
problem. is correct and the photocell is
The gate can open but
3.Photocell is blocked by N.C.
cannot close.
objects. 2.Make sure that the
4.Sensitivity of obstacle is too photocell mounting position
high. can be mutually aligned.
3.Remove the obstacle.
4.Reduce the sensitivity of
obstacle.
1.Battery level of the remote 1.Change the remote control
Remote control control is low. battery.
doesn’t work. 2.Remote control learning is not 2.Re-conduct remote control
completed. learning.
Press OPEN, CLOSE
According to the actual
button, the gate is not
Gate moving is not smoothly. situation to adjust the motor
moving, motor has
or the gate.
noise.
Leakage switch Power supply line short circuit or
Check wiring.
tripped. motor line short circuit.
Remote control Connect external receiver
working distance is too Signal is blocked. antenna, 1.5 meters above
short. ground.
1.Check whether the
1.Motor output force is not
transformer power is normal,
The gate moves to the enough.
if not, change the
middle position to stop 2.Sensitivity of obstacle is too
transformer.
or reverse. high.
2.Adjust the TR2.
3.Gate meets obstacle.
3.Remove the obstacle.

24
Warranty
Warranty Ordinance
1. To repair against this warranty card and invoice during the warranty period.
2. Warranty period: 1 year after the date of invoice.
3. Without unauthorized dismantling, any product broken or damage due to quality problem, we’ll
offer the repair service for free or replace for free.
4. The malfunction and damaged caused by incorrect use or man fault is not covered by this
warranty.

Maintenance Record

Check Date Check Content Maintained by

2018V1

25

You might also like