NEW CIRCUIT
PROTECTIONRANGE
TRUSTED PROTECTION
FOR YOUR RESIDENTIAL AND
COMMERCIAL INSTALLATIONS
GLOBAL SPECIALIST IN ELECTRICAL AND
DIGITAL BUILDING INFRASTRUCTURES
NEW
RCBO, RCCB AND MCB RANGE
PROTECTION YOU CAN RELY ON
Designed to meet
the requirements
of modern installations
in residential and commercial
applications, The new range
from Legrand provides
effective protection against
short circuits, overloads and
residual current faults. The
range, comprises of thermal
magnetic circuit breakers
and residual
current devices.
It ensures safety, ruggedness
and a high build quality
for your installations.
DX3 RCBOs TX3 RCCBs
• In = from 6 to 45A • In = from 16 to 80A
• Compact 1P + N, 2P • 2P and 4P
• Type AC and A • Type AC and A
• Sensitivity: 30mA • Sensitivity: 30, 100, 300 mA
• Compliant with AS/NZS 61 009-1 • Compliant with AS/NZS 61 008-1
1
Rugged reliability
10,000 operations with load
Electrical endurance
TX3 MCB
• In = 2 to 63A
• 1P to 3P
• C curves
• Breaking capacity: 6 000 A and 6KA at 230/400V a.c.
• Compliant with AS/NZS 60 898-1 - AS/NZS 60947-2
NEW CIRCUIT PROTECTION RANGE 2
WWW.LEGRAND.COM.AU
TX³ RCCB AND MCB
SAFETY ON ALL LEVELS
The new TX³ range
ensures safe installation
and operation
for maximum protection
of people and property.
For ease of installation,
wiring and maintenance,
the new TX³ range has
a number of features
which help save time
at each stage
of a project.
WIRE GUIDE FLAP RISING CAGE CLAMP BISTABLE CLAMP
Avoids connection errors TERMINALS For easy positioning or removal
for an increased safety level, of the product on the DIN rail.
The shape of the screws and
by preventing insertion of the Compatible with flat-blade or pozidriv
terminals ensures a high quality,
wire behind the terminal. screwdrivers. Several additional
durable connection of the wires
functions of the DX3 range, such
and limits contact impedance,
as isolating switches or single
temperature rise and heat loss.
pole + neutral RCBOs, are also
equipped with this clamp.
3
ERGONOMIC LABEL HOLDER THE EXTRA SPACE CLAMP INCREASED SAFETY
For custom labels. These holders Ensures more comfort during IP 2x terminals - no direct contact
provide effective, durable installation and allows independent with live parts, even with the
protection for the labels which MCB or RCCB faceplate open. Clamping screw for
are used to identify circuits clearly removal with supply flat-blade or Pozidriv screwdriver.
for the purposes of rapid intervention busbar in place Reinforced terminals allowing
in the event of an error. (without removing the tightening torques higher than those
other devices on the recommended by the standard.
same row).
RELIABLE CONNECTIONS
Prong and fork type comb busbars
guarantee connection quality by
eliminating the risk of short circuits
and ensuring a reliable connection
via the top or bottom of the device.
Limitation class 3
Circuit breakers with class 3
limitation provide excellent short
circuit protection. They limit the
short circuit energy released in
cables and hence help to extend
Bottom terminals are compatible with the service life of an installation.
fork or prong type comb busbars.
NEW CIRCUIT PROTECTION RANGE 4
WWW.LEGRAND.COM.AU
Compact RCBO and DX3 RCBO RCCBs
residual current circuit breakers from 6A to 40A residual current circuit breakers from 16A to 80A - AC and A types
602786 411002 411510 411709
Confirm to AS/NZS 61009-1 Conform to AS/NZS 61008-1
Not compatible with fork type busbars Compatible with prong type and fork type supply busbars
• Breaking capacity: 6000A • AC type ?: detect AC component faults
• A type M: detect AC and DC component faults • A type M: detect AC and DC component faults
Pack Cat.Nos Compact RCBO 1P+N - 6KA Pack Cat.Nos TX3 RCCB 2 pole - 230 V a.c.
A type M AC type ?
Sensitivity (mA) In (A) Number of modules Sensitivity (mA) In (A) Number of modules
1 602780 30 6 1
1 411502 10 16 2
1 411509 30 25 2
1 602782 30 10 1 1 411510 30 40 2
1 411511 30 63 2
1 602783 30 16 1 1 411512 30 80 2
1 602784 30 20 1 1 411519 100 25 2
1 411520 100 40 2
1 602785 30 25 1 1 411521 100 63 2
1 602786 30 32 1 1 411522 100 80 2
1 411529 300 25 2
1 411530 300 40 2
DX3 RCBO 1P+N - 10KA 1 411531 300 63 2
1 411532 300 80 2
Conform to AS/NZS 61009-1
Compatible with prong type and fork type supply busbars A type M
• Breaking capacity: 10KA 1 411552 10 16 2
• AC type ?: detect AC component faults 1 411559 30 25 2
• A type M: detect AC and DC component faults 1 411560 30 40 2
1 411561 30 63 2
DX3 RCBO Single pole + neutral - 230 V a.c. 1 411562 30 80 2
1 411564 100 25 2
Neutral on right-hand side 1 411565 100 40 2
1 411566 100 63 2
AC type ? 1 411567 100 80 2
Sensitivity (mA) In (A) Number of modules 1 411574 300 25 2
1 410999 30 6 2 1 411575 300 40 2
1 411000 30 10 2 1 411576 300 63 2
1 411577 300 80 2
1 411002 30 16 2
1 411003 30 20 2 TX3 RCCB 4 pole 400 V a.c.
1 411004 30 25 2 Neutral on right-hand side
1 411005 30 32 2
AC type ?
1 411006 30 40 2
Sensitivity (mA) In (A) Number of modules
A type M 1 411707 30 25 2
1 411047 30 6 2 1 411708 30 40 2
1 411709 30 63 2
1 411048 30 10 2 1 411710 30 80 2
1 411050 30 16 2 1 411717 100 25 2
1 411051 30 20 2 1 411718 100 40 2
1 411719 100 63 2
1 411052 30 25 2 1 411720 100 80 2
1 411053 30 32 2 1 411727 300 25 2
1 411054 30 40 2 1 411728 300 40 2
1 411729 300 63 2
1 411730 300 80 2
A type M
1 411764 30 25 2
1 411765 30 40 2
1 411766 30 63 2
1 411767 30 80 2
1 411774 100 25 2
1 411775 100 40 2
1 411776 100 63 2
1 411777 100 80 2
1 411784 300 25 2
1 411785 300 40 2
1 411786 300 63 2
1 411787 300 80 2
5
MCBs 6000 Supply busbars, entry terminals
thermal magnetic MCBs from 2A to 63A - C curve distribution
404914
404926
403434 403532 403551 404944 404905
Pack Cat.Nos Prong type supply busbars
Conform to AS/NZS 60898-1
Compatible with prong type and fork type supply busbars Universal single pole + neutral
Breaking capacity: Reversible: blue for neutral, black for live
6000 - AS/NZS 60898-1 - 230/400 V a.c. Length Max. number of
6 kA - AS/NZS 60947-2 - 230/400 V a.c. devices connected
20 404926 1 row 13
10 404937 Meter 57
Pack Cat.Nos TX3 MCB Single pole 230/400 V a.c.
Double pole
50 4049381 1 row 6
C curve Nominal rating In (A) Number of modules 10 404939 Meter 28
10 403427 2 1
Double pole balanced on 3 phases
10 403430 6 1 3 1 row 6
4049401
10 403432 10 1 10 404941 Meter 28
10 403433 13 1
10 403434 16 1
10 403435 20 1
Triple pole
10 403436 25 1 40 4049421 1 row 4
10 403437 32 1 10 404943 Meter 19
10 403438 40 1
10 403439 50 1
Four pole
10 403440 63 1 30 404944 1 row 3
TX3 MCB 2 pole 230/400 V a.c. 10 404945 Meter 14
C curve Nominal rating In (A) Number of modules
Fork type supply busbars
5 403521 2 2
5 403524 6 2 Single pole
Length Max. number of
5 403526 10 2 devices connected
5 403527 13 2 20 404911 1 row 12
5 403528 16 2 10 404912 Meter 57
5 403529 20 2 Double pole
5 403530 25 2 10 404914 Meter 28
5 403531 32 2
5 403532 40 2
5 403533 50 2 Triple pole
5 403534 63 2 5 404917 1 row 4
10 404918 Meter 19
TX3 MCB 3 pole 400 V a.c.
C curve Nominal rating In (A) Number of modules
Four pole
1 403538 2 3 10 404920 Meter 14
1 403541 6 3
1 403543 10 3
1 403544 13 3
1 403545 16 3 Protection
1 403546 20 3 Protection of prongs
1 403547 25 3 20 404988 12 modules
1 403548 32 3 Can be cut to length
1 403549 40 3 Protection of supply busbar ends
1 403550 50 3 40 404989 For single pole/single pole + neutral
1 403551 63 3
20 404990 For double pole length 1 m and triple pole
20 404991 For four pole
Entry terminals
20 404905 For universal single pole + neutral
or single pole supply busbars
Cross section: 4 to 25mm2 - IP 2X
20 404906 For all supply busbars
Cross section: 6 to 35mm2
1: Filled with end protection
NEW CIRCUIT PROTECTION RANGE 6
WWW.LEGRAND.COM.AU
HPM Legrand Australia
Building 4, Nexus Industry Park
43-47 Lyn Parade, Prestons NSW 2170
Tel.: 1300 369 777
www.legrand.com.au
www.hpm.com.au
HPML0465 - Nov 2015