This document provides specifications for the BeneVision N22/N19 patient monitor. It includes details on the physical dimensions, display, ECG, respiration, pulse oximetry, non-invasive blood pressure, temperature measurement and other parameters that can be monitored. The monitor has a large multi-parameter display and can monitor both adult and pediatric patients.

Uploaded by

Goutham Revuru
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
495 views4 pages

BeneVision N19 N22 Specifications

This document provides specifications for the BeneVision N22/N19 patient monitor. It includes details on the physical dimensions, display, ECG, respiration, pulse oximetry, non-invasive blood pressure, temperature measurement and other parameters that can be monitored. The monitor has a large multi-parameter display and can monitor both adult and pediatric patients.

Uploaded by

Goutham Revuru
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

BeneVision N22/N19

Patient monitor

Physical Specifications QT Analysis


Weight Including main unit with a battery, screen with Patient Adult/Pediatric/Neonate.
handle & navigation knob, iView module, and Wi- Parameters QT, QTc, ∆QTc
Fi module. QTc Formula Bazett, Fridericia, Framingham, or Hodges
N22: 11.5 kg (25.4 lbs) Range
N19: 10.3 kg (22.7 lbs) QT/QTc: 200 to 800 ms
Size Including main unit, screen with handle. QT-HR: Adult: 15 to 150 bpm
N22: 641 x 383 x 115 mm (portrait) Pediatric/Neonate: 15 to 180 bpm
566 x 458 x 115 mm (landscape) QT Accuracy ± 30 ms
N19: 584 x 348 x 115 mm (portrait) Resolution QT 4 ms; QTc 1 ms
509 x 423 x 115 mm (landscape) Respiration
Main unit: 268 x 268 x 68 mm Range 0 to 200 bpm
Display Resolution 1 rpm
Type Medical-grade color TFT LCD, capacitive touch Apnea Alarm Time 10, 15, 20, 25, 30, 35, 40 sec
screen, support multi-touch operation. Accuracy
Rotatable screen (Landscape and portrait) 0 - 120 rpm: ± 1 rpm
Resolution 1680 x 1050 pixels 121 - 200 rpm: ± 2 rpm
Screen Lead I, II, or auto (default: lead II)
N22: 22-inch, 178° viewing angle Pulse Oximetry
N19: 19-inch, 170° viewing angle Meet standards of ISO 80601-2-61.
Waveforms Up to 16 waveforms (portrait) Module Mindray, Masimo, Nellcor
Up to 13 waveforms (landscape) Range 0 to 100 %
ECG Resolution 1%
Meet standards of IEC 60601-2-27 and IEC 60601-2-25. Accuracy
Lead Sets Automatic 3/5/6/12 - lead recognition Mindray/Nellcor: ± 2 % (70 to 100%, Adult/Pediatric:)
3-lead: I, II, III ± 3 % (70 to 100%, Neonate)
5-lead: I, II, III, aVR, aVL, aVF, V Unspecified (0 to 69%)
6-lead: I, II, III, aVR, aVL, aVF, Va, Vb Masimo: ± 2 % (70 to 100%, Adult/Pediatric, non-motion)
12-lead: I, II, III, aVR, aVL, aVF, V1 to V6 ± 3 % (70 to 100%, Neonate, non-motion)
Sweep Speed 6.25 mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s ± 3 % (70 to 100%, motion)
Gain Selection x 0.125, x 0.25, x 0.5, x 1, x 2, x 4, auto Unspecified (0 to 69%)
Waveform format Standard, Cabrera Perfusion indicator (PI) Yes, for Mindray/Masimo SpO2
Input Signal Range ± 8 mV (p-p) Pitch Tone Yes
Electrode Offset Potential Tolerance ± 500 mV Dual-SpO2 Yes, SpO2, SpO2b, ∆SpO2
Bandwidth Pulse Rate Range
Diagnostic Mode: 0.05 to 150 Hz Mindray/Nellcor: 20 to 300 bpm
Monitor Mode: 0.5 to 40 Hz Masimo: 25 to 240 bpm
Surgical Mode: 1 to 20 Hz Pulse Rate Accuracy
ST Mode: 0.05 to 40 Hz Mindray: ± 3 bpm (20 - 300 bpm)
High Freq Cut-off (for 12-lead ECG analysis): Nellcor: ± 3 bpm (20 - 250 bpm)
350 Hz, 150 Hz, 35 Hz, 20 Hz selectable Masimo: ± 3 bpm (non-motion)
CMRR ± 5 bpm (motion)
Diagnostic: > 90 dB PR Refresh Rate 1 sec
Monitor, Surgical, ST mode:
> 105 dB (with notch filter on) Temperature
Pace detection Meet standard of ISO 80601-2-56.
Amplitude: ± 2 mV to ± 700 mV Method Thermal resistance
Width: 0.1 to 2 ms Channels Up to 8 channels
Rise time: 10 to 100 μs (without overshoot) Units of Measure Selectable °C or °F
Defibrillator Protection Withstand 5000VAC (360J) defibrillation Range 0 to 50 °C / 32 to 122 °F
Defib. Recovery Time ≤ 5 seconds Resolution 0.1 °C, 0.1°F
ESU recovery time ≤ 10 s Accuracy ± 0.1 °C or ± 0.2 °F (without probe)
Provides Glasgow resting 12-lead ECG algorithm. Refresh Rate 1 sec
Provides Mindray Multi(4)-lead ECG monitoring analysis algorithm. Genius TM 2 Tympanic Thermometer
(* These ECG specifications are from MPM Platinum module.) Measurement Range 33 to 42 °C / 91.4 to 107.6 °F
Heart Rate Calibrated Accuracy ± 0.1 °C (environment temperature 25 °C,
Measurement Range target temperature 36.7 to 38.9 °C)
Adult: 15 to 300 bpm ± 0.2 °C (environment temperature 16 °C,
Pediatric/Neonate: 15 to 350 bpm target temperature 33 to 42 °C)
Accuracy ± 1 bpm or ± 1%, whichever is greater. Resolution 0.1 °C, 0.1°F
Resolution 1 bpm Response Time < 2 sec
Arrhythmia Analysis
Patient Adult/Pediatric/Neonate. Non-Invasive Blood Pressure
Monitored Arrhythmias Asystole, VFib/VTac, VTac, Vent. Brady, Extreme Meet standards of ISO 80601-2-30.
Tachy, Extreme Brady, Vrhythm, PVCs/min, Method Oscillometry
Pauses/min, Couplet, Bigeminy, Trigeminy, R on T, Modes Manual, Auto, STAT, Sequence
Run PVCs, PVC, Tachy, Brady, Missed Beats, PNP, Units of Measure mmHg, kPa (user-selectable)
PNC, Multif. PVC, Nonsus. VTac, Pause, Irr. Resolution 1 mmHg
Rhythm, AFib. Systolic range
ST Segment Analysis Adult: 25 to 290 mmHg
Patient Adult/Pediatric. Pediatric: 25 to 240 mmHg
Range - 2.0 to + 2.0 mV (RTI) Neonate: 25 to 140 mmHg
Accuracy ± 0.02 mV or ± 10%, whichever is greater Diastolic range
(- 0.8 to + 0.8 mV) Adult: 10 to 250 mmHg
Resolution 0.01 mV Pediatric: 10 to 200 mmHg
Neonate: 10 to 115 mmHg CO2 Accuracy
Mean range 0 to 40 mmHg: ± 2mmHg
Adult: 15 to 260 mmHg 41 to 76 mmHg: ± 5% of reading
Pediatric: 15 to 215 mmHg 77 to 99 mmHg: ± 10% of reading
Neonate: 15 to 125 mmHg 100 to 150 mmHg: ± (3 mmHg+8% of reading)
Accuracy O2 Accuracy
Max Mean Error: ± 5 mmHg 0 to 25 %: ±1 %
Max Standard Deviation: 8 mmHg 25.1 to 80 %: ±2 %
Cuff Deflation Technique Step bleed 80.1 to 100 %±3 %
Initial Cuff Inflation Resolution
Adult: 80 to 280 mmHg (default: 160 mmHg) etCO2: 1 mmHg
Pediatric: 80 to 210 mmHg (default: 140 mmHg) O2 (optional) : 1%
Neonate: 60 to 140 mmHg (default: 90 mmHg) Sample Flow Rate
Over Pressure Protection Adult/Pediatric: 120 ml/min (with or without O2 monitoring)
Adult/ Pediatric: 297 ± 3 mmHg Neonate: 70 ml/min or 90 ml/min, selectable
Neonate: 147 ± 3 mmHg 90 ml/min (with O2 monitoring)
Max Measurement time Sample Flow Rate Tolerance
Adult/Pediatric: 180 sec ±15 ml/min or ±15 %, whichever is greater.
Neonate: 90 sec Warm-up Time 90 sec (maximum), 20 sec (typically)
Assisting Venous Puncture Yes Measured with a neonatal watertrap and 2.5-meter neonatal sampling line,
Pulse Rate Range 30 to 300 bpm or an adult watertrap and a 2.5-meter adult sampling line:
Pulse Rate Accuracy ± 3 bpm or ± 3 %, whichever is greater Rise Time
IBP etCO2: ≤ 250 ms @ 70 ml/min (Neonate watertrap)
Meet standard of IEC 60601-2-34. ≤ 250 ms @ 90 ml/min (Neonate watertrap)
Number Up to 8 channels ≤ 300 ms @ 120 ml/min (Adult watertrap)
Measurement Range -50 to 360 mmHg O2 (optional) : ≤ 800 ms @ 90 ml/min (Neonate watertrap)
Resolution 1 mmHg ≤ 750 ms @ 120 ml/min (Adult watertrap)
Accuracy ± 1 mmHg or ±2 %, whichever is greater Sampling Delay Time
(excluding sensor error) etCO2: ≤ 5.0 sec @ 70 ml/min (Neonate watertrap)
Sensitivity 5 μV/V/mmHg ≤ 4.5 sec @ 90 ml/min (Neonate watertrap)
Impedance Range 300 to 3000 Ω ≤ 5.0 sec @ 120 ml/min (Adult watertrap)
PPV Range 0 to 50 % O2 (optional) : ≤ 4.5 sec @ 90 ml/min (Neonate watertrap)
PAWP Yes ≤ 5.0 sec @ 120 ml/min (Adult watertrap)
ICP measurement Support awRR Range 0 to 150 rpm
Support waveforms overlapping. awRR Accuracy
Pulse Rate Range 25 to 350 bpm 0 to 60 rpm: ± 1 rpm
Pulse Rate Accuracy ±1 bpm or ±1 %, whichever is greater 61 to 150 rpm: ± 2 rpm
Cardiac Output Apnea Time 10, 15, 20, 25, 30, 35, 40 sec
Method Thermodilution Provide VCO2, VO2, MVCO2, MVO2, EE, RQ parameters, when monitoring with
Measurement Range 0.1 - 20 L/min RM module.
Resolution 0.1 L/min Oridion Microstream CO2
Accuracy ±0.1 L/min or ±5%, whichever is greater Measurement Range 0 to 99 mmHg
TB Range 23 to 43 °C / 73.4 to 109.4 °F Resolution 1 mmHg
TB, TI Accuracy ± 0.1 °C (without sensor) Accuracy
TB, TI Resolution 0.1 °C 0 to 38 mmHg: ±2 mmHg
PiCCO 39 to 99 mmHg: ±5 % + 0.08 % of the reading – 38 mmHg
Parameters Measurement Range Coefficient of Variation Sample Flow Rate 50 -7.5+15 ml/min
CCO 0.25 to 25.0 L/min ≤ 2% Start-up Time 30 sec (typical)
C.O. 0.25 to 25.0 L/min ≤ 2% Response Time 2.9 s (typical)
GEDV 40 to 4800 ml ≤ 3% awRR Range 0 to 150 rpm
SV 1 to 250 ml ≤ 2% awRR Accuracy
EVLW 10 to 5000 ml ≤ 6% 0 to 70 rpm: ±1 rpm
ITBV 50 to 6000 ml ≤ 3% 71 to 120 rpm: ±2 rpm
(Coefficient of variation is measured using synthetic and/or database wave 121 to 150 rpm: ±3 rpm
forms (laboratory testing.) Coefficient of variation= SD/mean error.) Apnea time 10, 15, 20, 25, 30, 35, 40 sec
TB Range 23 to 43 °C / 73.4 to 109.4 °F Capnostat Mainstream CO2
TB, TI Accuracy ± 0.1 °C (without sensor) Measurement Range 0 to 150 mmHg
TB, TI Resolution 0.1 °C Resolution 1 mmHg
pArt/pCVP Range -50 to 300 mmHg Accuracy
pArt/pCVP Accuracy ± 1 mmHg or ± 2 %, whichever is greater 0 to 40 mmHg: ± 2mmHg
ScvO2 41 to 70 mmHg: ± 5% of reading
Range 0 to 99 % 71 to 100 mmHg: ± 8% of reading
Accuracy ± 3% (50 to 80 %) 101 to 150 mmHg: ± 10% of reading
ICG Rise time < 60 msec
Method Thoracic electrical bioimpediance (TEB) awRR Range 0 to 150 rpm
HR Range 40 to 200 bpm (ICG), accuracy ±2 bpm awRR Accuracy ±1 rpm
C.O. Range 1.0 to 15 L/min Provide VCO2, MVCO2, FeCO2, SlopeCO2, Vtalv, MValv, Vdaw, Vdaw/Vt, Vdalv,
SV Range 5 to 250 ml Vdalv/Vt, Vdphy, Vd/Vt, when monitoring with RM module.
Provides Monitoring Parameters ACI, VI, PEP, LVET, TFI, TFC, HR, C.O., C.I., SV,
SVI, SVR, SVRI, PVR, PVRI, LCW, LCWI, LVSW, LVSWI, STR, VEPT Anesthesia Gases
Continuous Cardiac Output Interface Meet standard of ISO 80601-2-55.
Measured Parameter Consistent with CCO-related parameters Sampling Rate
outputted by Vigilance II®, Vigileo™, or EV1000 Adult/pediatric: 200 ml/min
Vigilance II: CCO, CCI, C.O., C.I., SV, SVI, SVR, SVRI, RVEF, EDV, Neonate: 120 ml/min
EDVI, ESV, ESVI, TB, SaO2, VO2, O2EI, DO2, ScvO2, Sampling Rate Tolerance ±10 ml/min or ±10%, whichever is greater.
SvO2, SQI Sampling Delay Time < 4 sec
Vigileo: CCO, CCI, SV, SVI, SVR, SVRI, ScvO2, SvO2 Refresh Rate 1 sec
EV1000: CCO, CCI, CO, CI, SV, SVI, SVV, SVR, SVRI, GEF, CFI, Warm-up Time 45 sec to warm-up status
GEDV, ITBV, ITBI, EVLW, EVWI, PVPI 10 min to ready-to-measure status
Artema Sidestream CO2 Measurement Range
Meet standard of ISO 80601-2-55. CO2: 0 to 30 %
Measurement Range N2O: 0 to 100 %
etCO2: 0 to 150 mmHg Des/Sev/Enf/Iso/Hal:
O2 (optional) : 0 to 100 % 0 to 30 %
O2: 0 to 100 % Flow Adult/Pediatric: ± 1.2 L/min or ± 10% of the
awRR: 2 to 100 rpm reading, whichever is greater.
Resolution Neonate: ± 0.5 L/min or ± 10%, whichever is
CO2: 0.1 % greater.
N2O: 1% Paw ± 3% of reading
Des/Sev/Enf/Iso/Hal: MVe/MVi ± 10% of reading
0.1 % TVe/TVi Adult/Pediatric: ±10% or ±15 ml, whichever is
O2: 1% greater.
awRR: 1 rpm Infant: ±10% or ±6 ml, whichever is greater.
Full Accuracy awRR: ±1 rpm (4 to 99 rpm)
Gases Range (%REL) Accuracy (%ABS) ±2 rpm (100 to 120 rpm)
CO2: 0 to 1 % ± 0.1 % Provide loops display.
1 to 5 % ± 0.2 % Monitoring parameters include PEEP, Pmean, PIP, Pplat, PEF, PIF, MVe, MVi, TVe,
5 to 7 % ± 0.3 % TVi, RR, I:E, FEV1.0, Compl, RSBI, NIF, WOB, RAW.
7 to 10 % ± 0.5 %
> 10 % Not specified rSO2
N2O: 0 to 20 % ±2% Patient Adult/Pediatric/Neonate.
20 to 100 % ±3% Method INVOS, NIRS (Near Infrared Spectroscopy)
Des: 0 to 1 % ± 0.15 % Number Up to 4 channels
1 to 5 % ± 0.2 % Measurement Range 15 to 95 %
5 to 10 % ± 0.4 % NMT
10 to 15 % ± 0.6 % Meet the standard of IEC 60601-2-10
15 to 18 % ±1% Sensor Type Acceleromyography sensor
> 18 % Not specified Stimulation Modes ST, TOF, PTC, DBS3.2, DBS3.3
Sev: 0 to 1 % ± 0.15 % Stimulation Current Range
1 to 5 % ± 0.2 % 0 to 60 mA
5 to 8 % ± 0.4 % Stimulation Current Accuracy
>8% Not specified ± 5% or ±2 mA, whichever is greater.
Enf/Iso/Hal: 0 to 1 % ± 0.15 % Stimulation Pulse Width 100,200 or 300μs,monophasic rectangle pulse
1 to 5 % ± 0.2 % Stimulation Pulse Width Accuracy
>5% Not specified ± 10 %
O2: 0 to 25 % ±1% Max. Output Voltage 300 V
25 to 80 % ±2% BISx/BISx4
80 to 100 % ±3% Meet standard of IEC 60601-2-26.
awRR: 2 to 60 rpm ± 1 rpm Method Bispectral Index
> 60 rpm Not specified Impedance Range 0 to 999 kΩ
Rise Time EEG Bandwidth 0.25 to 100 Hz
Sampling flow 120 ml/min, using the DRYLINE II TM watertrap and a BIS Range 0 to 100 (BIS, BIS L, BIS R)
neonatal 2.5m sampling line, SQI Range 0 to 100 % (SQI, SQI L, SQI R)
CO2/ N2O: ≤ 250 ms ASYM 0 to 100%
Iso/Hal/Sev/Des: ≤ 300 ms DSA Trend Yes
Enf: ≤ 350 ms EEG
O2: ≤ 600 ms Meet standard of IEC 60601-2-26.
Sampling flow 200ml/min, using DRYLINE II TM watertrap and an adult EEG Channels Up to 4 channels
2.5m sampling line: Montage Mode Biopolar mode, referential mode
CO2/ N2O: ≤ 250 ms Input Signal Range - 2 mVp-p to + 2mVp-p
Iso/Hal/Sev/Des: ≤ 300 ms Max. Input DC Offset ± 500 mV
Enf: ≤ 350 ms CMRR ≥ 100 dB @51 kΩ imbalance and 60 Hz
O2: ≤ 500 ms Noise Level ≤ 0.5 μV rms (1 Hz to 30 Hz)
Sampling Delay Time Differential Input Impedance
Sampling flow 120 ml/min, using the DRYLINE II TM watertrap and a > 15 MΩ @10 Hz
neonatal 2.5m sampling line, Electrode Impedance
CO2: ≤ 4 sec Range 0 to 90 kΩ
N2O: ≤ 4.2 sec Accurancy ± 1 kΩ or ± 10%, whichever is greater
O2: ≤ 4 sec Sampling Frequency 1024 Hz
Enf /Iso/Hal/Sev/Des: ≤ 4.4 sec Analog bandwidth 0.5 to 110 Hz
Sampling flow 200ml/min, using DRYLINE II TM watertrap and an adult Spectrum analysis SEF, MF, PPF, TF, Delta, Theta, Alpha, and Beda
2.5m sampling line: Trend DSA, CSA
CO2: ≤ 4.2 sec
N2O: ≤ 4.3 sec tcGas
O2: ≤ 4 sec Interfaces with TCM CombiM, TCM TOSCA or SenTec SDM monitor.
Enf/Iso/Hal/Sev/Des: ≤ 4.5 sec Measurement Range
Apnea time 10,15,20,25,30,35,40 sec tcpCO2 5 to 200 mmHg
Provide MAC value (support calibrated by age). tcpO2 0 to 800 mmHg
Support two mixed gas identify and monitoring. SpO2 0 to 100 %
RM PR 25 to 240 bpm
Method Diff-Pressure flow Power 0 to 1000 mW
Measurement Range Accuracy
Flow Adult/Pediatric: ± (2 to 120) L/min tcpCO2 TOSCA Sensor 92, tc Sensor 54:
Neonate: ± (0.5 to 30) L/min Better than 1 mmHg (1 % or 10 % CO2)
Paw -20 to 120 cmH2O Better than 3 mmHg (33 % CO2)
MVe/MVi Adult/Pediatric: 2 to 60 L/min tc Sensor 84:
Infant: 0.5 to 15 L/min Better than 1 mmHg (1 % or 10 % CO2)
TVe/TVi Adult/Pediatric: 100 to 1500 ml Better than 5 mmHg (33 % CO2)
Infant: 20 to 500 ml tcpO2 tc Sensor 84:
awRR range 4 to 120 rpm Better than 1 mmHg (0 % O2)
Resolution Better than 3 mmHg (21 % O2)
Flow 0.1 L/min Better than 5 mmHg (50 % O2)
Paw 0.1 cmH2O Better than 25 mmHg (90 % O2)
MVe/MVi 0.01 L/min (MVe/MVi < 10 L/min) SpO2 ±3 % (70 to 100 %)
0.1 L/min (MVe/MVi ≥ 10 L/min) PR ±3 bpm
TVe/TVi 1 ml Power ±20 % of reading
awRR: 1 rpm
Accuracy iView
CPU Intel Pentium N4200 2.5GHz Output
Memory 8 GB Auxiliary Output
Hard-disk mSATA SSD 128GB Standard Meets the requirements of ANSI/AAMI/IEC
OS Windows 10 60601-1 for short-circuit protection and leakage
Recorder current
Type Thermal array ECG Analog Output
Speed 25 mm/sec, 50 mm/sec Bandwidth (- 3 dB; reference frequency: 10 Hz)
Trace Up to 3 (paper 50 mm width, 20 m length) Diagnostic Mode: 0.05 to 150 Hz
Supports two-slots recorder module. Monitor Mode: 0.5 to 40 Hz
Alarms Surgical Mode: 1 to 20 Hz
Audible indicator Yes, 3 different alarm tones, and prompt tone ST Mode: 0.05 to 40 Hz
Visible indicator Red/yellow/cyan LED, and alarm message QRS Delay ≤ 25 ms (in diagnostic mode, and non-paced)
Provide AlarmSight infographic alarm indicator. Sensitivity 1 V/mV, ± 5 %
Data Storage Pace Enhancement
Trends Data > 120 hrs @ 1min, 4 hrs @ 5 sec. Signal Amplitude: Voh ≥ 2.5 V
Events 1000 events, including parameter alarms, Pulse Width: 10 ms ± 5 %
arrhythmia events, technical alarms, and so on. Signal Rising and Falling Time:
NIBP 1000 sets ≤ 100 μs
Interpretation of resting 12-lead ECG results
20 sets IBP Analog Output
Full disclosure 48 hours for all parameters and waveforms Bandwidth (- 3 dB; reference frequency: 10 Hz)
(8G storage card) 0 to 40 Hz
48 hours at maximum. The specific storage time Max. Transmission Delay 30 ms
depends on the waveforms stored and the Sensitivity 1 V/100 mmHg, ± 5 %
number of stored waveforms. (2G storage card) Interfacing
OxyCRG 48 hrs Main Unit
ST review 120 hrs @1 min 1 AC Power Connector
Minitrend Yes 2 RJ45 Network Connector, 100 Base-TX, IEEE 802.3
Special Functions 6 USB 2.0 Connector
Clinical Assistive Application (CAA): 3 Nonstandard USB SMR Connector
HemoSightTM, ST GraphicTM, SepsisSightTM, BoA 1 VP Connector, VP1 for the secondary display
DashboardTM, EWS, GCS, 24hrs ECG Summary, 1 BNC Connector
Pace View 1 Equipotential Grounding Terminal
Support calculations (drug, hemodynamic, Oxygenation, Ventilation, Renal), Modular iView
and Titration table. 1 VP Connector, VP2
Support wireless connection with BeneVision TM80 and BP10. 4 USB 2.0 Connector
Support nView remote display tool 1 RJ45 Network Connector, 100 Base-TX, IEEE 802.3
Multifunction Connector for Defib Sync and Analog Output
Wi-Fi Communications 1 on multi-parameter module
Protocol IEEE 802.11a/b/g/n Barcode Scanner Support 1D and 2D barcode
Modulation Mode DSSS and OFDM Keyboard & Mouse Support wire and wireless type
Operating Frequency Remote Control Support
IEEE 802.11b/g/n (2.4G): Network Printer Support
ETSI/FCC/KC: 2.4 to 2.483 GHz Battery
MIC: 2.4 to 2.495 GHz Type Rechargeable lithium-ion
IEEE 802.11a/n (5G): Number of Battery 1
ETSI: 5.15 to 5.35 GHz, 5.47 to 5.725 GHz Capacity 5600mAh, 113 VDC
FCC: 5.15 to 5.35 GHz, 5.725 to 5.82 GHz Run Time > 1 hrs
MIC: 5.15 to 5.35 GHz when powered by a new fully-charged battery at
KC: 5.15 to 5.35 GHz, 5.47 to 5.725 GHz, 25 ºC±5 ºC with 12-lead ECG , Resp, SpO2, 4-ch
5.725 to 5.82 GHz IBP, 2-ch Temp, CO2, C.O. and NIBP
Channel Spacing 5 MHz @ 2.4 GHz (802.11 b/g/n) measurements every 15 min, WiFi enabled, and
20 MHz @ 5 GHz (802.11 a/n) screen brightness set to default 5,
Wireless Baud Rate IEEE 802.11a: 6 to 54 Mbps Recharge Time 5 hrs to 90% when the monitor is off.
IEEE 802.11b: 1 to 11 Mbps Power Requirements
IEEE 802.11g: 6 to 54 Mbps AC Voltage 100 to 240 VAC (±10 %)
IEEE 802.11n: 6.5 to 72.2 Mbps Current 2.8 to1.6 A
Output Power < 20dBm (CE requirement: detection Frequency 50 Hz/60 Hz (±3 Hz)
mode- RMS) Environmental
< 30dBm (FCC requirement, detection Temperature Operating: 0 to 40 °C (32 to 104 °F)
mode- peak power) Storage: -20 to 60 °C (-4 to 140 °F )
Operating Mode Infrastructure Humidity Operating: 15 to 95 % (non condensing)
Data Security WPA-PSK, WPA2-PSK, WPA-Enterprise, Storage: 10 to 95 % (non condensing)
WPA2-Enterprise (EAP-FAST, EAP-TLS, EAP-TTLS, Barometric Operating: 427.5 to 805.5 mmHg (57.0 to 107.4
PEAP-GTC, PEAP-MSCHAPv2, PEAP-TLS, LEAP) kPa)
Encryption: TKIP and AES Storage: 120 to 805.5 mmHg (16.0 to 107.4 kPa)
MPAN Communications Safety
Modulation Mode GFSK Type of Protection Class I
Operating Frequency 2402 to 2480 MHz Degree of Protection MPM/IBP/C.O./NMT/EEG module: CF
Channel Spacing 2 MHz ScvO2/CO2/AG/BIS/rSO2 module: BF
Wireless Baud Rate 1 Mbps Protection Against Ingress of Fluids
Output Power ≤ 2.5 mW IPX1
Data Security Private protocol --------------------------------------------------------------
MPAN is used in device pairing for BeneVision TM80, BP10 NIBP module and Some of functions marked with an asterisk may not be available. Please
BeneVision N series patient monitor. contact your local Mindray sales representative for the most current
information.
| Healthcare with reach are registered trademarks or trademarks owned by Shenzhen Mindray Bio-medical Electronics Co., LTD
Mindray Building, Keji 12th Road South, © 2019 Shenzhen Mindray Bio-medical Electronics Co., Ltd. All rights reserved. Specifications subject to changes without prior notice.
High-tech Industrial Park, Nanshan, Shenzhen 518057, P.R. China P/N: ENG-BeneVision N22/N19 Datasheet-210285x4P-20190610
Tel: +86 755 8188 8998 Fax: +86 755 26582680
E-mail: [email protected] www.mindray.com