GE CARESCAPE R860 Ventilator Overview

The document discusses the GE CARESCAPE R860 ventilator, including that it can ventilate patients from adult to neonatal sizes, has standard and optional ventilation modes, and optional advanced applications like measuring lung volumes and pressures. It also covers the ventilator's graphical user interface and marketing approach.

Uploaded by

Hai Anh Phung
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
459 views35 pages

GE CARESCAPE R860 Ventilator Overview

The document discusses the GE CARESCAPE R860 ventilator, including that it can ventilate patients from adult to neonatal sizes, has standard and optional ventilation modes, and optional advanced applications like measuring lung volumes and pressures. It also covers the ventilator's graphical user interface and marketing approach.

Uploaded by

Hai Anh Phung
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 35

Internal use only

GE CARESCAPE R860
Product presentation (extended)
Product Management Respiratory Care
Lübeck, June 2015, Stefan Mixa
Internal use only

GE CARESCAPE R860
Agenda

 Device overview
 Ventilation modes
 Advanced applications
 Graphical User Interface
 Marketing approach

2 | 35 GE CARESCAPE R860 Product presentation (extended) | June 2015 | Stefan Mixa


Internal use only

GE CARESCAPE R860
Device overview

3 | 35 GE CARESCAPE R860 Product presentation (extended) | June 2015 | Stefan Mixa


Internal use only

GE CARESCAPE R860
Device overview

 One device for all patient types


 Adult Adult to Neonatal
 Pediatric
 Neonatal

 One device for


 Invasive and &
 Non-invasive ventilation

 New philosophy of graphical user interface


 Past
 Present
 Future

4 | 35 GE CARESCAPE R860 Product presentation (extended) | June 2015 | Stefan Mixa


Internal use only

GE CARESCAPE R860
Agenda

 Device overview
 Ventilation modes
 Ventilation applications
 Graphical User Interface
 Marketing approach

5 | 35 GE CARESCAPE R860 Product presentation (extended) | June 2015 | Stefan Mixa


Internal use only

GE CARESCAPE R860
Ventilation modes

Standard:

 VC: AC, SIMV, PRVC [Pressure Regulated Volume Control]

 PC: AC, SIMV

 SPN: CPAP/PS, SBT [Spontaneous Breathing Trial]

Optional:

 VC: SIMV PRVC

 PC: APRV

 SPN: CPAP/VS, BiLevel, BiLevel VG

 NIV: adult and pediatric = PS, neonatal = nCPAP

6 | 35 GE CARESCAPE R860 Product presentation (extended) | June 2015 | Stefan Mixa


Internal use only

GE CARESCAPE R860
SBT (Spontaneous Breathing Trial) (Standard)

 The SBT is used to assess a patient’s ability to get weaned off the ventilator
 This feature will place the patient in CPAP/PS mode for a set amount of time to
check his ability for spontaneous breathing on his own
 The SBT displays the minute ventilation, respiratory rate and end-tidal CO2 for
the time of the trial
 If the minute volume, respiratory rate or apnea alarm limits are exceeded during
the SBT, the trial will end and ventilator will return to the predefined mode and
settings
 The SBT split screen displays the MVexp, RR, and EtCO2 for the trial

7 | 35 GE CARESCAPE R860 Product presentation (extended) | June 2015 | Stefan Mixa


Internal use only

GE CARESCAPE R860
BiLevel (optional)

 Mixed mode which allows spontaneous BiLevel waveforms


breathing in pressure controlled ventilation
 The ventilator synchronizes spontaneous
breathing with changes in pressure level
 The ventilator switches between two
pressure levels at set times
 If a spontaneous breath is detected within a
window of 4 seconds, the breath is delivered
by an increase to PHigh
 If the spontaneous breath is detected outside
the window, a pressure supported breath is
delivered

8 | 35 GE CARESCAPE R860 Product presentation (extended) | June 2015 | Stefan Mixa


Internal use only

GE CARESCAPE R860
BiLevel VG (optional)

 BiLevel VG combines the “open valve”


technology of BiLevel with the benefits of
volume guarantee
 It ensures that the set tidal volume is
delivered during the high pressure level
 The volume guarantee automatically sets
the inspiratory pressure to the lowest
possible level to provide the set tidal
volume.

BiLevel - VG waveforms

9 | 35 GE CARESCAPE R860 Product presentation (extended) | June 2015 | Stefan Mixa


Internal use only

GE CARESCAPE R860
NIV (optional)

 NIV option is designed with two modes:


- NIV for adult and pediatric
- nCPAP for neonatal
 NIV is only available in pressure support mode such as
CPAP/PS
 Integrated unique leak recognition algorithm
 Use with nasal or face masks
 nCPAP (optional) is only available with neonatal mode
 nCPAP is delivered without the use of neonatal flow sensor

10 | 35 GE CARESCAPE R860 Product presentation (extended) | June 2015 | Stefan Mixa


Internal use only

GE CARESCAPE R860
Neonatal ventilation mode (optional)

 Ventilation mode for intubated neonatal patients weighing


down to 0.25 kg
 Ventilation by using a proximal flow sensor at the patient
wye
 Sensor allows flows
- as low as 0.2 L/min and
- as high as 30 L/min
 Automatic patient detection (APD) in standby
 Precise volume regulation during mechanical, assisted or
spontaneous modes
 Neonatal nCPAP is available
 No high frequency ventilation available

11 | 35 GE CARESCAPE R860 Product presentation (extended) | June 2015 | Stefan Mixa


Internal use only

GE CARESCAPE R860
Agenda

 Device overview
 Ventilation modes
 Advanced applications
 Graphical User Interface
 Marketing approach

12 | 35 GE CARESCAPE R860 Product presentation (extended) | June 2015 | Stefan Mixa


Internal use only

GE CARESCAPE R860
Advanced applications (optional)

 SpiroDynamics*
(Tracheal pressure measurement)
 FRC INview*
(Measurement of Functional Residual Capacity)
 PEEP INview*
(See how the PEEP value affects the FRC value)
 Lung INview*
(Measures the volume between dynostatic curves at the set
PEEP levels of the PEEP INview procedure)
 Metabolics*
(Calorimetry measurements)

* All advanced applications are already available in GE Engström Carestation

13 | 35 GE CARESCAPE R860 Product presentation (extended) | June 2015 | Stefan Mixa


Internal use only

GE CARESCAPE R860
SpiroDynamics (optional)

 Measurement of tracheal pressure and intrinsic PEEP (Tracheal pressure


measured via intratracheal pressure sensor)
 Similar to Spirometry by creating a PV loop that is analyzed by the user
 Freezes current loops and provides numeric display of X and Y axis as cursor
moves across loops
 Pressure and volume values displayed at cursor position
 Not available in neonatal mode

14 | 35 GE CARESCAPE R860 Product presentation (extended) | June 2015 | Stefan Mixa


Internal use only

GE CARESCAPE R860
SpiroDynamics (optional)

 The Sensor is inserted into the endotracheal tube


proximal to the Y- piece
 After a breath, a dynostatic curve is calculated from the
loop providing an estimate of the alveolar pressure and
volume

15 | 35 GE CARESCAPE R860 Product presentation (extended) | June 2015 | Stefan Mixa


Internal use only

GE CARESCAPE R860
FRC INview (optional)

 Enables to measure Functional Residual Capacity


on mechanically ventilated patients
 Calculation based on the nitrogen washout method
using a step change ( ∆ +10% abs. FiO2)
in the oxygen/air concentration

 An FRC procedure takes 2 measurements


 When FRC procedure is started, the system
captures a baseline of N2 concentration and
then changes the set O2 to the set FRC O2
 After a few breaths, a curve begins to plot
on the graph
 Provides the user with data for determining the
optimal PEEP setting for the patient
 Not available in neonatal mode

16 | 35 GE CARESCAPE R860 Product presentation (extended) | June 2015 | Stefan Mixa


Internal use only

GE CARESCAPE R860
PEEP INview (optional)

 The PEEP INview procedure can


be used to see how a change in
the PEEP value affects the FRC
value  helps the clinician to
determine the optimal PEEP
 A series of FRC measurements
are taken at varying PEEP levels
 PEEP levels can increase or
decrease
 Best PEEP when the FRC
difference is the biggest
 Only available with FRC INview
 Not available in neonatal mode

17 | 35 GE CARESCAPE R860 Product presentation (extended) | June 2015 | Stefan Mixa


Internal use only

GE CARESCAPE R860
Lung INview (optional)

3000
 Available when SpiroDynamics and FRC INview
are used together

FRC volume axis


Lung INview

 Integrate SpiroDynamics and FRC INview within


the PEEP INview procedure
 complete Lung INview display
 Measures the amount of volume between the PEEP axis 30

dynostatic curves at the set PEEP levels PEEP curve for 5 measurements

 When FRC measurement is taken, data is also PEEP curve minus the difference between
SpiroDynamic dynostatic curve (= Lung INview)
taken from the SpiroDynamics loop to obtain
information on absolute volume
 Comparing the volumes from several dynostatic
curves results in a difference that can be
estimated as recruited volume
 Not available in neonatal mode

18 | 35 GE CARESCAPE R860 Product presentation (extended) | June 2015 | Stefan Mixa


Internal use only

GE CARESCAPE R860
Metabolics

 The GE gas module measures


inhaled and exhaled gases
 physician can use to assess
the nutritional status of the patient
 Measured parameters:
 Avg ACO2 - VCO2 CV
 Avg VO2 - VO2 CV
 Avg RQ - Avg EE
 Avg EE/m2 - Avg EE/kg
 BSA
 Weight

 Evidence- based nutritional


assessment like the Metabolics
can improve the patient
outcomes, reduce infection and
shortens the length of stay

19 | 35 GE CARESCAPE R860 Product presentation (extended) | June 2015 | Stefan Mixa


Internal use only

GE CARESCAPE R860
GE gas module (optional)

 The GE gas module measures


and monitors inhaled and exhaled
gases (by sidestream method)
 Modules measure CO2, O2 and
spirometry inputs
 Et and Fi values updated breath
by breath
 Gas modules is needed for the
Spirometry and Metabolics
measurement

20 | 35 GE CARESCAPE R860 Product presentation (extended) | June 2015 | Stefan Mixa


Internal use only

GE CARESCAPE R860
Airway Resistance Compensation (ARC)

 Level of compensation: 25% to 100%


 Provides pressure support level base on tube
size and inspiratory flow
 Can support all pressure- controlled, CPAP and
pressure- supported breaths for patients with a
PBW ≥ 10.0 kg / endotracheal/ tracheostomy
tubes ID ≥ 5.0 mm.
 Only pediatrics and adults, can not support
neonates

21 | 35 GE CARESCAPE R860 Product presentation (extended) | June 2015 | Stefan Mixa


Internal use only

GE CARESCAPE R860
Leak compensation

 It compensates the leaks in the breathing circuit to maintain PEEP


and prevent auto- triggering
 Automatically adjust ventilation delivery and monitoring for breathing
circuit and patient airway leaks to maintain the desired tidal volume
 Available in invasive and noninvasive ventilation for the modes
VC, PC- VG, SIMV- VC
 The system limits volume control leak compensation to 25% of the
set tidal volume for adult patients and 100% for 100ml
 Monitored parameter:
- %LEAK [%]

22 | 35 GE CARESCAPE R860 Product presentation (extended) | June 2015 | Stefan Mixa


Internal use only

GE CARESCAPE R860
Agenda

 Device overview
 Ventilation modes
 Advanced applications
 Graphical User Interface
 Marketing approach

23 | 35 GE CARESCAPE R860 Product presentation (extended) | June 2015 | Stefan Mixa


Internal use only

GE CARESCAPE R860
Overview

 New touch screen motions:


 Swipe
 Slide
 Double- tap
 Touch and hold

 Traditional hard keys for direct access:

1. Alarm silence key


2. ↑O2- Key (Push to deliver 100% O2 for 2 minutes)
3. Screen capture icon
4. Key off
5. Home button
6. Trim knob: “Touch, turn, accept”

24 | 35 GE CARESCAPE R860 Product presentation (extended) | June 2015 | Stefan Mixa


Internal use only

GE CARESCAPE R860
Menu- free navigation

 3 workspaces available:  Intuitively organized and easily


1) Past (Historical trends) accessible to relevant clinical content
2) Present (Patient status) and therapy controls
3) Future (Clinical decision support)

 “Swipe left to right to navigate from past to present to future.”

25 | 35 GE CARESCAPE R860 Product presentation (extended) | June 2015 | Stefan Mixa


Internal use only

GE CARESCAPE R860
3 workspaces: Past, Present, Future

Past Present Future


 Event- centric historical  Breath- by- breath views  Providing tools for
data available  Essential parameters weaning, lung protection
 Multiple waveforms and nutrition accessment

26 | 35 GE CARESCAPE R860 Product presentation (extended) | June 2015 | Stefan Mixa


Internal use only

GE CARESCAPE R860
Standby display
Patient type:
Alarm configuration
adult, pediatric, neonatal

Menu

System check
Select patient type
Bar graph
(Paw measurement)
Information
about patient

Start ventilation
Current mode

FiO2 Pmax
Tidal volume PEEP
Respiratory rate Flow
27 | 35 GE CARESCAPE R860 Product presentation (extended) | June 2015 | Stefan Mixa
Internal use only

GE CARESCAPE R860
Graphical User Interface

 Easily manage alarms


– Green flashlight on top
– Alarm history

 Take snapshots
– Record waveforms, alarms, measured
and set values
– Max. stored snapshots: 10 most recent
– Waveform data (15 or 30 seconds)
– Ability to cursor across waveforms for
specific measured values

28 | 35 GE CARESCAPE R860 Product presentation (extended) | June 2015 | Stefan Mixa


Internal use only

GE CARESCAPE R860
Agenda

 Device overview
 Ventilation modes
 Advanced applications
 Graphical User Interface
 Marketing approach

29 | 35 GE CARESCAPE R860 Product presentation (extended) | June 2015 | Stefan Mixa


Internal use only

GE CARESCAPE R860
Marketing approach

 Key slogans:
 “The logical path to Lung Protection”
 “A touch of brilliance”

 “It’s nice to see a familiar interface”


 “Choose your view, you’re the director”
 “Travel through time with a single touch”
 “Gentler breaths for easy breathing”
 “Connecting intelligence and care”

30 | 35 GE CARESCAPE R860 Product presentation (extended) | June 2015 | Stefan Mixa


Internal use only

GE CARESCAPE R860
Marketing approach

 Related product series:


 CARESCAPE Central Station
 CARESCAPE Monitor B450
 CARESCAPE Monitor B650
 CARESCAPE Monitor B850

CARESCAPE Monitor B450 CARESCAPE Monitor B650 CARESCAPE Monitor B850

31 | 35 GE CARESCAPE R860 Product presentation (extended) | June 2015 | Stefan Mixa


Internal use only

GE CARESCAPE R860
Marketing approach

Related product series:


 The GE anesthesia devices feature
the CARESCAPE Monitors
 CARESCAPE -inspired user experience

32 | 35 GE CARESCAPE R860 Product presentation (extended) | June 2015 | Stefan Mixa


Internal use only

GE CARESCAPE R860
Pricing

Performance

Evita V500

CARESCAPE R860

Evita V300

Savina 300

Savina (color)

Price

33 | 35 GE CARESCAPE R860 Product presentation (extended) | June 2015 | Stefan Mixa


Internal use only

GE CARESCAPE R860
Additional information

 Material on the GE webpage


 Overview and videos

 Material on the Dräger Intranet SalesView


 USP comparison
 Product overview
 Competitor Matrix (incl. CARESCAPE R860)

 Material on Dräger GoBench


 GoBench GE CARESCAPE R860

(Please click on picture)

We would appreciate it if you could send any feedback and additional information (i.e. on pricing) to [email protected]

34 | 35 GE CARESCAPE R860 Product presentation (extended) | June 2015 | Stefan Mixa


Internal use only

Thank
Vielen you
Dankfor
für Ihre
your attention.
Aufmerksamkeit.

You might also like