Specification Sheet LED LINEAR
Specification Sheet LED LINEAR
D ES C R IPTION
Type
Catalog #
SWLED is a versatile LED surface or wall mount luminaire which can
be used in a broad range of commercial and industrial applications.
This series provides customers with a high quality luminaire utilizing Project
the latest LED, solid state lighting and electronic driver technology for
optimal performance and maximized energy efficiency. Offered with Date
Comments
three different lens distributions and three different lens options which
provides uniform light distribution that is an ideal choice for general
purpose lighting where connected control is desired or required such as Prepared by
stairwells or other spaces seeking maximum energy savings.
Construction minimum 80 CRI. TM21 rating up offer three different lens versions
Housing consists of die formed to L91 > 60,000 hours. Electronic - LC (clear), LN (Semi-Frost with
cold rolled steel with decorative drivers are available for 120-277V narrow distribution) and LW (full
white opaque injection molded end applications. A 0-10V dimming frost with wide distribution). This
plates. Reflector/channel wireway driver is standard. lenses provide different lighting
cover secured by fasteners for distribution allowing customers
easy wireway access. Channel E me rg e n cy Ba ttery Pack Option to choice between smooth even
back has numerous KO’s for easy Optional 120V-277V integral illumination. Lens is securely held
installation. emergency battery pack is in place by removable injection
available in 7-watts or 14-watts molded white end caps that can be
Controls to meet critical life-safety lighting easily removed for installation and
Metalux LED luminaires come requirements. The 90-minute maintenance.
standard with 0-10V dimming batteries provide constant power
drivers 10% standard, 1% optional. to the LED system, ensuring Installation SWLED
Combine with energy saving code-compliance. A test switch/ Fixture may be surface (wall or
products like occupancy sensors, indicator button can be tested ceiling) and suspended mounted. LED
daylighting controls and lighting safely from the ground using a See accessories below for ordering
relay panels to maximize energy laser pointer, while the patented EZ information.
savings. Key prevents accidental discharge
Surface and Wall LED
Options compatible with Eaton’s of the battery during construction. Compliance
Connected Lighting Systems: Emergency/generator transfer Indoor luminaires are cULus
options available – see ordering listed for up to 40ºC ambient
• WaveLinx sensor information for details. environments, RoHS compliant,
• LumaWatt Pro sensor and LED modules comply with
• SVPD sensor F in ish IESNA LM-79 and LM-80 standards.
• Fifth Light DALI driver Highly reflective post painted Suitable for use in clothes closets
finish (PAF) standard offering recommended for use in stairwells
Other options include step- customers the optimal finish when installed in accordance
dimming and 3rd party drivers. and handling. Additionally, each with the NEC 410.16 spacing
Refer to the Connected Lighting housing is treated in a multistage requirements. Can be used for
options page and ordering iron phosphate pretreatment, State of California Title 24 high
information for more details. ensuring maximum bonding and efficacy luminaire. DesignLights
rust inhibitor. Consortium® Qualified and
El e c t r i c a l
classified for both DLC Standard
Long-Life LED system coupled with Sh ie ld in g and DLC Premium, refer to www.
electrical driver to deliver optimal Specially designed LED lens blends designlights.org for details.
performance. LED’s available and linear optics allows us to
in 3500K, 4000K or 5000K with
Wireless System
N JOUR
IG N
ES A
L
D
PLATINUM
2 0 1 6
4-11/16" 4-11/16"
[120mm] [120mm]
California Title 24
Non-Residential
Compliant
ADF142352
May 7, 2018 10:33 AM
S W LE D
MOUNT ING D A TA
4-11/16"
[120mm]
28" [711mm]
4'
45-3/16" [1148mm]
Lensed
4-11/16"
[120mm]
52" [1320mm]
Full Frost (LW) Standard 4 ft. 4SWLED-16SL-LW-UNV-L840-CD1-U 1626 14.3 114 148
Full Frost (LW) Standard 4 ft. 4SWLED-20SL-LW-UNV-L840-CD1-U 1983 17.6 113 146
Full Frost (LW) Standard 4 ft. 4SWLED-28SL-LW-UNV-L840-CD1-U 2841 24.8 115 148
Full Frost (LW) Standard 4 ft. 4SWLED-32SL-LW-UNV-L840-CD1-U 3217 28.6 112 145
Full Frost (LW) Standard 4 ft. 4SWLED-36SL-LW-UNV-L840-CD1-U 3573 32.8 109 141
Full Frost (LW) Standard 4 ft. 4SWLED-40SL-LW-UNV-L840-CD1-U 4015 37.9 106 137
Full Frost (LW) High 4 ft. 4SWLED-44HL-LW-UNV-L840-CD1-U 4436 39.7 112 145
Full Frost (LW) High 4 ft. 4SWLED-48HL-LW-UNV-L840-CD1-U 4899 44.6 110 143
Full Frost (LW) High 4 ft. 4SWLED-52HL-LW-UNV-L840-CD1-U 5175 47.7 108 140
Full Frost (LW) High 4 ft. 4SWLED-56HL-LW-UNV-L840-CD1-U 5623 52.9 106 137
Full Frost (LW) High 4 ft. 4SWLED-60HL-LW-UNV-L840-CD1-U 5977 53.7 111 144
Full Frost (LW) High 4 ft. 4SWLED-64HL-LW-UNV-L840-CD1-U 6369 58.2 109 141
Full Frost (LW) High 4 ft. 4SWLED-67HL-LW-UNV-L840-CD1-U 6708 61.9 108 140
Full Frost (LW) High 4 ft. 4SWLED-72HL-LW-UNV-L840-CD1-U 7201 67.7 106 137
Full Frost (LW) High 4 ft. 4SWLED-78HL-LW-UNV-L840-CD1-U 7832 75.4 104 135
Full Frost (LW) High 4 ft. 4SWLED-80HL-LW-UNV-L840-CD1-U 8060 78.4 103 133
CCT TA B LE
Eaton
1121 Highway 74 South
Peachtree City, GA 30269 Specifications and
P: 770-486-4800 dimensions subject to
ADF142352
www.eaton.com/lighting change without notice. May 7, 2018 10:33 AM
S W LE D
PH OTOM ETR IC S
Zonal Lumen Summary Luminance Data Zonal Lumen Summary Luminance Data
Average Average Average Average Average Average
Zone Lumens % Fixture Angle 0-Deg 45-Deg 90-Deg Zone Lumens % Fixture Angle 0-Deg 45-Deg 90-Deg
in Deg cd/sm cd/sm cd/sm in Deg cd/sm cd/sm cd/sm
0-30 510 20.6 0-30 854 21.3
45 8170 7066 7174 45 7080 6000 5883
0-40 842 34.0 0-40 1408 35.1
55 7555 6530 6835 55 6720 5549 5551
0-60 1540 62.2 65 6561 6010 6614 0-60 2562 63.8 65 6126 5069 5250
0-90 2220 89.7 75 4987 5606 6626 0-90 3649 90.9 75 5027 4637 5068
0-180 2475 100.0 85 2452 5480 6916 0-180 4015 100.0 85 3313 4416 5156
SH IP P ING D A T A
Catalog No. Wt.
2SWLED 6 lbs.
4SWLED 12 lbs.
Eaton
1121 Highway 74 South
Peachtree City, GA 30269 Specifications and
P: 770-486-4800 dimensions subject to
ADF142352
www.eaton.com/lighting change without notice. May 7, 2018 10:33 AM
S W LE D
NOTES: (1) Nominal lumen output see table for performance values. (2) 2 ft. model. (3) Only available in 4 ft. models. (4) With integral test switch/indicator/laser test. For approximate delivered lumens multiply the
lumens per watt of the desired fixture by the wattage of the emergency battery pack (100 lm/W x 7=700 lumens). IES-format photometry for luminaire under emergency operation available. (5) For mounting
heights up to 30 ft. (6) For mounting heights up to 12 ft. (7) Integral EL battery pack is rated for 35°C. (8) 347V option – 60HL and above uses two drivers. (9) DesignLights Consortium® Qualified and classified for
both DLC Standard and DLC Premium, refer to www.designlights.org for details. (10) For wall mount applications. (11) Used to bypass local control during outage. Must be used in conjunction with UL 1008
device (provided by others). GTR2 and ETR2 options include 2 relays on fixtures with dimming drivers. ETRD option only requires one relay when used on a dimming fixture. Must specify voltage as 120V or
277V when ordering these devices. (12) SR driver compatible with LWI option only. (13) Must be used in conjunction with a LumaWatt Pro control system. For complete LumaWatt Pro wireless solutions, visit
www.eaton.com/lumawattpro (14) Integral sensor works with CD and HCD driver and is factory prewired to the driver for stand-alone control. (15) LWT compatible with CD and HCD drivers only. (16) LWT sensor is
external to luminaire, cable factory wired. (17) SW compatible with CD and HCD drivers only. (18) SW option must be used in conjunction with an Eaton control system. For complete Eaton wireless system
solutions, visit www.eaton.com/lightingsystems. (19) 347V listing in DLC is for standard 347V ONLY driver. No DLC listing for UNC.
Specifications & dimensions subject to change without notice. Consult your Eaton Representative for availability and ordering information.
Eaton
1121 Highway 74 South
Peachtree City, GA 30269 Specifications and
P: 770-486-4800 dimensions subject to
ADF142352
www.eaton.com/lighting change without notice. May 7, 2018 10:33 AM
S W LE D
The SWLED with Integrated Sensor technology provides automatic energy savings without sacrificing performance. Traditionally, these
types of energy savings required coordination between the luminaire and a lighting control system. The SWLED delivers superior
lighting with integrated occupancy and daylighting controls.
Capture the benefits of traditional lighting controls, without complicated coverage planning or special wiring. Ideal for
new construction or retrofit, the SWLED delivers automatic ON to an energy saving light level, ensuring lighting
is turned OFF when the space is unoccupied.
The integral daylight sensor reduces the need for special daylight zone planning. Each luminaire will
automatically adjust the light level based on reflected light beneath the sensor in a closed loop method.
Occupied daylight light levels and unoccupied light levels can be adjusted using the integrated sensor
programming remote (Catalog Number: ISHH-01). The integrated sensor personal remote (Catalog
Number: ISHH-02) provides code compliant manual raise, lower, ON, OFF control.
The SWLED with Integrated Sensor is easy to install with no special wiring and ensures energy savings out-of-the-box
with default control settings.
How i t w o r k s :
• As the user enters the space controlled by the integral sensor, the lighting turns ON to the default daylight level.
• Lighting will remain at that the daylight level until the space is unoccupied. This will start the occupancy timeout period (default 20 minutes).
• If the space remains unoccupied for half of the timeout period, the lighting will automatically reduce to the Energy Saver light level. This adjustable
light level is typically half of the occupied daylight level.
• At the end of the timeout period the lighting will go to the unoccupied light level. This adjustable light level uses the OFF default setting.
100
Energy Savings
Opportunities
(DO) (DO)
Light Level
(DU)
0 Timeout Value Unoccupied Level
Unoccupied Occupied Unoccupied Occupied
Target light level default: 500 lux at 8 ft.
C over ag e P a t t e r n s n e x t p a g e
Eaton
1121 Highway 74 South
Peachtree City, GA 30269 Specifications and
P: 770-486-4800 dimensions subject to
ADF142352
www.eaton.com/lighting change without notice. May 7, 2018 10:33 AM