Metalux

D ES C R IPTION
Type
Catalog #
SWLED is a versatile LED surface or wall mount luminaire which can
be used in a broad range of commercial and industrial applications.
This series provides customers with a high quality luminaire utilizing Project
the latest LED, solid state lighting and electronic driver technology for
optimal performance and maximized energy efficiency. Offered with Date
Comments
three different lens distributions and three different lens options which
provides uniform light distribution that is an ideal choice for general
purpose lighting where connected control is desired or required such as Prepared by
stairwells or other spaces seeking maximum energy savings.

S PEC IFIC A TION FEA T U R E S

Construction minimum 80 CRI. TM21 rating up offer three different lens versions
Housing consists of die formed to L91 > 60,000 hours. Electronic - LC (clear), LN (Semi-Frost with
cold rolled steel with decorative drivers are available for 120-277V narrow distribution) and LW (full
white opaque injection molded end applications. A 0-10V dimming frost with wide distribution). This
plates. Reflector/channel wireway driver is standard. lenses provide different lighting
cover secured by fasteners for distribution allowing customers
easy wireway access. Channel E me rg e n cy Ba ttery Pack Option to choice between smooth even
back has numerous KO’s for easy Optional 120V-277V integral illumination. Lens is securely held
installation. emergency battery pack is in place by removable injection
available in 7-watts or 14-watts molded white end caps that can be
Controls to meet critical life-safety lighting easily removed for installation and
Metalux LED luminaires come requirements. The 90-minute maintenance.
standard with 0-10V dimming batteries provide constant power
drivers 10% standard, 1% optional. to the LED system, ensuring Installation SWLED
Combine with energy saving code-compliance. A test switch/ Fixture may be surface (wall or
products like occupancy sensors, indicator button can be tested ceiling) and suspended mounted. LED
daylighting controls and lighting safely from the ground using a See accessories below for ordering
relay panels to maximize energy laser pointer, while the patented EZ information.
savings. Key prevents accidental discharge
Surface and Wall LED
Options compatible with Eaton’s of the battery during construction. Compliance
Connected Lighting Systems: Emergency/generator transfer Indoor luminaires are cULus
options available – see ordering listed for up to 40ºC ambient
• WaveLinx sensor information for details. environments, RoHS compliant,
• LumaWatt Pro sensor and LED modules comply with
• SVPD sensor F in ish IESNA LM-79 and LM-80 standards.
• Fifth Light DALI driver Highly reflective post painted Suitable for use in clothes closets
finish (PAF) standard offering recommended for use in stairwells
Other options include step- customers the optimal finish when installed in accordance
dimming and 3rd party drivers. and handling. Additionally, each with the NEC 410.16 spacing
Refer to the Connected Lighting housing is treated in a multistage requirements. Can be used for
options page and ordering iron phosphate pretreatment, State of California Title 24 high
information for more details. ensuring maximum bonding and efficacy luminaire. DesignLights
rust inhibitor. Consortium® Qualified and
El e c t r i c a l
classified for both DLC Standard
Long-Life LED system coupled with Sh ie ld in g and DLC Premium, refer to www.
electrical driver to deliver optimal Specially designed LED lens blends designlights.org for details.
performance. LED’s available and linear optics allows us to
in 3500K, 4000K or 5000K with

Connected Lighting Powered by

Wireless System

N JOUR
IG N
ES A
L
D

PLATINUM
2 0 1 6

4-11/16" 4-11/16"
[120mm] [120mm]

California Title 24
Non-Residential
Compliant

4-1/2" [114mm] 4-1/32" [102mm]

WITH SVPD SENSORS WITH LUMAWATT PRO


OR WAVELINX SENSORS

Safe and convenient means of


disconnecting power

ADF142352
May 7, 2018 10:33 AM
S W LE D

MOUNT ING D A TA

2' 21-3/16" [538mm]


Lensed

4-11/16"
[120mm]

28" [711mm]

4'
45-3/16" [1148mm]
Lensed

4-11/16"
[120mm]

52" [1320mm]

ENERGY A ND PER FOR M AN C E DAT A B Y C AT AL O G N U M B E R

Lumen Nominal lm/W with Approx. lm/W with


Lens Type Type Length Catalog Logic Lumens Wattage LW Lens LC/LN lens
Full Frost (LW) Standard 2 ft. 2SWLED-8SL-LW-UNV-L840-CD1-U 914 9.0 102 120
Full Frost (LW) Standard 2 ft. 2SWLED-16SL-LW-UNV-L840-CD1-U 1597 15.9 100 118
Full Frost (LW) Standard 2 ft. 2SWLED-20SL-LW-UNV-L840-CD1-U 1987 20.6 96 115
Full Frost (LW) High 2 ft. 2SWLED-24HL-LW-UNV-L840-CD1-U 2475 24.0 103 133
Full Frost (LW) High 2 ft. 2SWLED-28HL-LW-UNV-L840-CD1-U 2813 27.9 101 130

Full Frost (LW) Standard 4 ft. 4SWLED-16SL-LW-UNV-L840-CD1-U 1626 14.3 114 148
Full Frost (LW) Standard 4 ft. 4SWLED-20SL-LW-UNV-L840-CD1-U 1983 17.6 113 146
Full Frost (LW) Standard 4 ft. 4SWLED-28SL-LW-UNV-L840-CD1-U 2841 24.8 115 148
Full Frost (LW) Standard 4 ft. 4SWLED-32SL-LW-UNV-L840-CD1-U 3217 28.6 112 145
Full Frost (LW) Standard 4 ft. 4SWLED-36SL-LW-UNV-L840-CD1-U 3573 32.8 109 141
Full Frost (LW) Standard 4 ft. 4SWLED-40SL-LW-UNV-L840-CD1-U 4015 37.9 106 137
Full Frost (LW) High 4 ft. 4SWLED-44HL-LW-UNV-L840-CD1-U 4436 39.7 112 145
Full Frost (LW) High 4 ft. 4SWLED-48HL-LW-UNV-L840-CD1-U 4899 44.6 110 143
Full Frost (LW) High 4 ft. 4SWLED-52HL-LW-UNV-L840-CD1-U 5175 47.7 108 140
Full Frost (LW) High 4 ft. 4SWLED-56HL-LW-UNV-L840-CD1-U 5623 52.9 106 137
Full Frost (LW) High 4 ft. 4SWLED-60HL-LW-UNV-L840-CD1-U 5977 53.7 111 144
Full Frost (LW) High 4 ft. 4SWLED-64HL-LW-UNV-L840-CD1-U 6369 58.2 109 141
Full Frost (LW) High 4 ft. 4SWLED-67HL-LW-UNV-L840-CD1-U 6708 61.9 108 140
Full Frost (LW) High 4 ft. 4SWLED-72HL-LW-UNV-L840-CD1-U 7201 67.7 106 137
Full Frost (LW) High 4 ft. 4SWLED-78HL-LW-UNV-L840-CD1-U 7832 75.4 104 135
Full Frost (LW) High 4 ft. 4SWLED-80HL-LW-UNV-L840-CD1-U 8060 78.4 103 133

CCT TA B LE

Approximate Color Temperature Multiplier


5000K 1.03
4000K 1.00
3500K 0.98

Eaton
1121 Highway 74 South
Peachtree City, GA 30269 Specifications and
P: 770-486-4800 dimensions subject to
ADF142352
www.eaton.com/lighting change without notice. May 7, 2018 10:33 AM
S W LE D

PH OTOM ETR IC S

2SWLED-24HL- Candlepower 4SWLED-40SL- Candlepower


90˚
LW-UNV-L840- Angle Along II 45° Across ⊥ 90˚
LW-UNV-L840- Angle Along II 45° Across ⊥
80˚ CD1-U 0 649 649 649 80˚ CD1-U 0 1096 1096 1096
163
Electronic Driver 5 649 648 645 276
Electronic Driver 5 1101 1094 1088
70˚ 70˚
10 641 640 637 10 1086 1080 1074
60˚ Linear LED 4000K 15 627 629 629 60˚ Linear LED 4000K 15 1059 1056 1055
326 553
Spacing criterion: 20 607 611 614 Spacing criterion: 20 1023 1025 1027
50˚ 25 581 587 596 50˚ 25 978 986 991
489
(II) 1.25 x mounting 30 549 560 574 829
(II) 1.25 x mounting 30 924 941 952
height, (⊥) 1.32 x 35 514 530 548 height, (⊥) 1.29 x 35 864 888 908
40˚ mounting height 40 475 497 522 40˚ mounting height 40 796 831 858
652 1105
45 432 462 491 45 723 769 805
0˚ 10˚ 20˚ 30˚ Lumens: 2475 0˚ 10˚ 20˚ 30˚ Lumens: 4015
50 385 423 459 50 647 703 749
Input Watts: 24W 55 333 383 425 Input Watts: 37.9W 55 565 634 690
60 280 342 392 60 479 563 628
Efficacy: 103.1 lm/W 223 301 357
Efficacy: 105.9 lm/W 389 491 567
65 65
Test Report: 70 168 261 325 Test Report: 70 298 422 507
2SWLED-24HL-LW- 75 114 224 293 4SWLED-40SL-LW- 75 206 355 448
80 66 189 261 80 124 295 393
UNV-L840-CD1-U. UNV-L840-CD1-U.
85 27 158 229 85 57 238 341
IES 90 0 129 199 IES 90 1 193 294
Coefficients of Utilization Coefficients of Utilization
Effective floor cavity reflectance 20% Effective floor cavity reflectance 20%
rc 80% 70% 50% 30% 10% 0% rc 80% 70% 50% 30% 10% 0%
rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0 rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
RCR RCR
0 117 117 117 117 113 113 113 113 105 105 105 99 99 99 93 93 93 90 0 117 117 117 117 113 113 113 113 106 106 106 100 100 100 94 94 94 91
1 104 98 93 88 100 95 90 86 89 85 81 83 80 77 78 75 73 70 1 104 99 94 89 101 96 91 87 90 86 82 84 81 78 79 76 74 71
2 94 84 77 70 90 82 75 69 76 70 65 71 67 62 67 63 59 57 2 94 85 77 71 91 82 75 69 77 71 66 72 68 63 68 64 61 58
3 85 73 65 57 81 71 63 56 66 60 54 62 56 52 58 54 49 47 3 85 74 65 58 82 72 63 57 67 60 55 63 57 53 60 55 51 48
4 77 65 55 48 74 63 54 47 59 51 45 55 49 44 52 46 42 39 4 78 65 56 49 75 63 55 48 59 52 46 56 50 45 53 47 43 40
5 71 57 48 41 68 56 47 40 52 45 39 49 43 38 46 41 36 34 5 71 58 49 42 69 56 47 41 53 45 40 50 43 38 47 42 37 35
6 65 52 42 36 63 50 41 35 47 39 34 44 38 33 42 36 32 29 6 66 52 43 36 63 51 42 35 48 40 34 45 39 33 43 37 32 30
7 61 47 38 31 58 45 37 31 43 35 30 40 34 29 38 32 28 26 7 61 47 38 32 59 46 37 31 43 36 30 41 34 29 39 33 29 26
8 56 42 34 28 54 41 33 27 39 32 26 37 30 26 35 29 25 23 8 57 43 34 28 55 42 33 28 40 32 27 38 31 26 36 30 26 23
9 53 39 30 25 51 38 30 24 36 29 24 34 28 23 32 27 22 20 9 53 39 31 25 51 38 30 25 36 29 24 35 28 24 33 27 23 21
10 49 36 28 22 47 35 27 22 33 26 21 32 25 21 30 24 20 18 10 50 36 28 23 48 35 28 22 34 27 22 32 26 21 31 25 21 19

Zonal Lumen Summary Luminance Data Zonal Lumen Summary Luminance Data
Average Average Average Average Average Average
Zone Lumens % Fixture Angle 0-Deg 45-Deg 90-Deg Zone Lumens % Fixture Angle 0-Deg 45-Deg 90-Deg
in Deg cd/sm cd/sm cd/sm in Deg cd/sm cd/sm cd/sm
0-30 510 20.6 0-30 854 21.3
45 8170 7066 7174 45 7080 6000 5883
0-40 842 34.0 0-40 1408 35.1
55 7555 6530 6835 55 6720 5549 5551
0-60 1540 62.2 65 6561 6010 6614 0-60 2562 63.8 65 6126 5069 5250
0-90 2220 89.7 75 4987 5606 6626 0-90 3649 90.9 75 5027 4637 5068
0-180 2475 100.0 85 2452 5480 6916 0-180 4015 100.0 85 3313 4416 5156

SH IP P ING D A T A
Catalog No. Wt.
2SWLED 6 lbs.
4SWLED 12 lbs.

Eaton
1121 Highway 74 South
Peachtree City, GA 30269 Specifications and
P: 770-486-4800 dimensions subject to
ADF142352
www.eaton.com/lighting change without notice. May 7, 2018 10:33 AM
S W LE D

ORDER ING INFOR M A TION

SAMPLE NUMBER: 4SWLED-40SL-LW-UNV-L840-CD1-SVPD2-U

Length LED Lumens (1) Voltage Driver Type Packaging


2=2 ft. Length 8SL=900 (2) UNV=Universal Voltage CD=0-10V Dimming Driver
U=Unit Pack
4=4 ft. Length 16SL=1600 120-277 HCD=0-10V Dimming Driver Integrated Sensing Systems
20SL=2000 347V=347 Volt (8) (1% - 100% Dimming) SWPD1=WaveLinx Wireless Integrated Sensor (17), (18), (A)
Series (9) 24HL=2400 UNC=347V/480V (19) SD=Step-dim Driver LWIPD1=LumaWatt Pro Wireless Integrated Sensor (12), (B)
SWLED=LED Surface 28HL=2800 5LTD=Fifth Light (DALI) Driver LWTPD1=LumaWatt Pro Wireless Tile-mount Sensor (15), (16), (B)
and Wall 28SL=2800 (3) Emergency (3), (7) SR=Sensor Ready SVPD1=0-10V Stand-alone, Integrated occupancy and
32SL=3200 EL7W=7-watt, 120V-277V emergency (1% - 100% Dimming) (12) daylight dimming sensor, 500 sq. ft. coverage (D)
36SL=3600 battery pack installed (4) SVPD2=Integrated occupancy and daylight dimming
40SL=4000 EL14W=14-watt 120V-277V emergency Number of Drivers sensor, 900 sq. ft. coverage (6), (10), (14)
44HL=4400 battery pack installed (4) 1=1 Driver SVPD3=Integrated occupancy and daylight dimming
48HL=4800 GTR2=Bodine Generator Transfer Relay (11) 2=2 Drivers (8) sensor, 1200 sq. ft. coverage (5), (14)
52HL=5200 ETR2=Iota Emergency Transfer Relay (11)
56HL=5600 ETRD=Iota Emergency Transfer Relay with
60HL=6000 dimming control (11)
64HL=6400
67HL=6700 CCT
72HL=7200 L835=3500K
78HL=7800 L840=4000K
80HL=8000 L850=5000K ACCESSORIES
Optic (Order Separately)
LC=Clear Lens SCF=Fixed Stem Set (Specify Length)
LN=Semi-Frost Lens - Narrow SCS=Swivel Stem Set (Specify Length)
LW=Full Frost Lens - Wide SCA=Adjustable 48" Stem Set
A1B/Spacer-U=Spacer 1-1/2" to 2-1/2" from ceiling
(Use 2 Per Fixture)
ISHH-01=Programming Remote for Integrated Sensor
ISHH-02=Personal Control Remote for Integrated Sensor

NOTES: (1) Nominal lumen output see table for performance values. (2) 2 ft. model. (3) Only available in 4 ft. models. (4) With integral test switch/indicator/laser test. For approximate delivered lumens multiply the
lumens per watt of the desired fixture by the wattage of the emergency battery pack (100 lm/W x 7=700 lumens). IES-format photometry for luminaire under emergency operation available. (5) For mounting
heights up to 30 ft. (6) For mounting heights up to 12 ft. (7) Integral EL battery pack is rated for 35°C. (8) 347V option – 60HL and above uses two drivers. (9) DesignLights Consortium® Qualified and classified for
both DLC Standard and DLC Premium, refer to www.designlights.org for details. (10) For wall mount applications. (11) Used to bypass local control during outage. Must be used in conjunction with UL 1008
device (provided by others). GTR2 and ETR2 options include 2 relays on fixtures with dimming drivers. ETRD option only requires one relay when used on a dimming fixture. Must specify voltage as 120V or
277V when ordering these devices. (12) SR driver compatible with LWI option only. (13) Must be used in conjunction with a LumaWatt Pro control system. For complete LumaWatt Pro wireless solutions, visit
www.eaton.com/lumawattpro (14) Integral sensor works with CD and HCD driver and is factory prewired to the driver for stand-alone control. (15) LWT compatible with CD and HCD drivers only. (16) LWT sensor is
external to luminaire, cable factory wired. (17) SW compatible with CD and HCD drivers only. (18) SW option must be used in conjunction with an Eaton control system. For complete Eaton wireless system
solutions, visit www.eaton.com/lightingsystems. (19) 347V listing in DLC is for standard 347V ONLY driver. No DLC listing for UNC.
Specifications & dimensions subject to change without notice. Consult your Eaton Representative for availability and ordering information.

Integrated Sensing and Control System Options


NOTES: Integrated options must be used in conjunction with the associated system and may not be compatible with other options or accessories. Please refer to the following: (A) Consult WaveLinx system pages for
additional details and compatibility. (B) Consult LumaWatt Pro system pages for additional details and compatibility. (D) Consult SVPD series system pages for additional details and compatibility. (E) Consult Fifth Light
system pages for additional details and compatibility.

Eaton
1121 Highway 74 South
Peachtree City, GA 30269 Specifications and
P: 770-486-4800 dimensions subject to
ADF142352
www.eaton.com/lighting change without notice. May 7, 2018 10:33 AM
S W LE D

INTEGR A TED S ENS OR

The SWLED with Integrated Sensor technology provides automatic energy savings without sacrificing performance. Traditionally, these
types of energy savings required coordination between the luminaire and a lighting control system. The SWLED delivers superior
lighting with integrated occupancy and daylighting controls.
Capture the benefits of traditional lighting controls, without complicated coverage planning or special wiring. Ideal for
new construction or retrofit, the SWLED delivers automatic ON to an energy saving light level, ensuring lighting
is turned OFF when the space is unoccupied.
The integral daylight sensor reduces the need for special daylight zone planning. Each luminaire will
automatically adjust the light level based on reflected light beneath the sensor in a closed loop method.
Occupied daylight light levels and unoccupied light levels can be adjusted using the integrated sensor
programming remote (Catalog Number: ISHH-01). The integrated sensor personal remote (Catalog
Number: ISHH-02) provides code compliant manual raise, lower, ON, OFF control.
The SWLED with Integrated Sensor is easy to install with no special wiring and ensures energy savings out-of-the-box
with default control settings.

How i t w o r k s :
• As the user enters the space controlled by the integral sensor, the lighting turns ON to the default daylight level.
• Lighting will remain at that the daylight level until the space is unoccupied. This will start the occupancy timeout period (default 20 minutes).
• If the space remains unoccupied for half of the timeout period, the lighting will automatically reduce to the Energy Saver light level. This adjustable
light level is typically half of the occupied daylight level.
• At the end of the timeout period the lighting will go to the unoccupied light level. This adjustable light level uses the OFF default setting.

100
Energy Savings
Opportunities

(DO) (DO)
Light Level

Daylight Level Daylight Level

(DU)
0 Timeout Value Unoccupied Level
Unoccupied Occupied Unoccupied Occupied
Target light level default: 500 lux at 8 ft.

C over ag e P a t t e r n s n e x t p a g e

Eaton
1121 Highway 74 South
Peachtree City, GA 30269 Specifications and
P: 770-486-4800 dimensions subject to
ADF142352
www.eaton.com/lighting change without notice. May 7, 2018 10:33 AM