ERV-2020-LGUK ERVB 05 20v1
ERV-2020-LGUK ERVB 05 20v1
LG HVAC
SOLUTIONS
ENERGY RECOVERY
VENTILATION (ERV)
NECESSITY OF ERV
Outdoor lemp
Energy Recovery Ventilation (ERV) Indoor lemp
(winter)
22 C
o
-5oC
16 C
o
24%
Comfort air + Energy Saving Natural Ventilation
Compare to natural ventilation
Energy Saving
Heat exchanger collects wasted
energy while ventilating.
-5oC
HIGH EFFICIENCY
High Efficiency Heat Exchanger CO2 Auto Operation
Efficiency and comfort is ensured through the high-efficiency energy LG ERV reduces energy loss with auto fan speed control following
recovery central core which recovers energy from the indoor air and CO2 level
Fine CO2 level
transfers it to the fresh incoming air without mixing the air stream. High occupancy Low occupancy CO2 level
(high CO2 level) (low CO2 level) Fan speed
Air Filter
Exchanger Air
Supply Air
Low
4% Energy Saving
(Annually)
9 o’clock 10 11 12 13 14 15 16 17
* This function is operated with ‘Night Time Free Cooling’ on remote controller. (with MULTI V only)
** Energy saving ratio can be differed by weather condition.
※ Test Condition - Office (49,000ft2) / Occupancy : 30 / Area : London, UK
- ERV (1000 CMH) + MULTI V 4 (12HP) Unit Combination
- Other conditions are subject to BREEAM.
Supply Month Jan. Feb. Mar. Apr. May. Jun. Jul. Aug. Sep. Oct. Nov. Dec.
Air
Heat recovery mode Bypass mode
Outdoor Air Indoor Air Outdoor
Air Indoor Outdoor Indoor Outdoor
Inside is getting
higher in the night
2% Energy Saving
(Annually)
Office time
starts
because of business Operation
machines. time
Demand Cooling only Demand Cooling & Ventilation
* This function is operated with ‘Night Time Free Cooling’ on remote controller. (with MULTI V only)
** Energy saving ratio can be differed by weather condition. * This function is operated with ‘Night Time Free Cooling’ on remote controller. (with MULTI V only)
※ Test Condition ** Energy saving ratio can be differed by weather condition.
- Office (49,000ft2) / Occupancy : 30 / Area : London, UK ※ Test Condition - Office (49,000ft2) / Occupancy : 30 / Area : London, UK
- ERV (1000 CMH) + MULTI V 4 (12HP) Unit Combination - ERV (1000 CMH) + MULTI V 4 (12HP) Unit Combination
- Other conditions are subject to BREEAM. - Other conditions are subject to BREEAM.
2 /3
https://www.lg.com/uk/business/air-conditioning-systems LG Air Conditioning and Energy Solutions UK 2020
INDOOR _ VENTILATION SOLUTIONS _ KEY FEATURES
Easy
• Navigation buttons, easy to use.
• Easy installation setting
Monitoring CO2
CO2 1215 ppm
comfort level
20.5°
* The remote controller screen image may change. CO2 • Indoor CO2 level
* Applicable to only Standard III, Premium remote
CO2
1215 ppm SEVERE • Alarm for filter change / Remained time to change filters
controller.
Group Control
1 wired remote controller up to 16 ERV (including air conditioner).
CO2 Concentration Control It is convenient for large common spaces such as lobby areas.
Using CO2 sensor, LG ERV controls exhaust air flow automatically to keep
indoor air fresh under settled CO2 concentration.
Several units combination
16 units group control is available with 1 remote controller.
CO2 Sensor
RS3 Remote Good looking interior
(AHCS 100H0)
(Internal type : Default) Controller
CO2
(ppm)
1,000
LG ERV
Inside ERV
Heat exchanger
Corrosion protection
coating
+ Finish insulator
Bacteria-resistant
EAEA
(Exhaust
(Exhaust
air outlet)
air outlet)
Exhausting operation causes
negative indoor air pressure,
Ceiling Fixing Bolt and cannot fully ventilate.
(M10~12) OAOA
(Fresh
(Fresh
air outlet)
air outlet)
Nut
150~250
Min.600
Inspection
150~250
Min.600
Inspection
partpart
Washer, Spring Lock Exhausting and Supplying 450(600)
450(600)
Fast Ventilation Mode Simultaneously
Washer, Plain Air supply
Air supply grillegrille
(user-supplied)
(user-supplied)
Nut Maintenance
Maintenance
tal heat
space
space
Exchanger
tal heat Exchanger
Air Filter
Air Filter
Exhaust
Fan DuctDuct normal
normal diameter
diameter
Supply ØC(user-supplied)
ØC(user-supplied) Ceiling
Ceiling Fixing
Fixing BoltBolt
(user-supplied)
(user-supplied)
Ceiling Fixing Bolt
Fan
(M10~12)
Nut
Duct
Washer, Spring Lock Air supply
Air supply grillegrille
Air return
Air return grillegrille
External
Washer, PlainStatic Pressure Control
EAEA
(Exhaust
(Exhaust Inspection
Inspection partpart
The high static pressure fan can control the air volume depending on the air outlet)
air outlet)
OAOA 450(600)
450(600)
Nut (Fresh
(Fresh air outlet)
air outlet)
RARASASA
length of the duct. It is also easy to control the pressure level by using the DuctDuct slope:
slope: MoreMore
thanthan 1/30(toward
1/30(toward
Obtaining of right
the wall)
the wall)
distance (Return
(Return air) air)(Supply
(Supply
air) air)
Obtaining of right distance
remote controller for a more flexible duct installation and easier testing. (preventing
(preventing penetration
penetration of rain
of rain water)
water)
Taping
Connection of Duct
Air
Volume Duct
H Duct
M
L
H
M
L
Taping Taping
Duct External Static Pressure (mmAq)
30 30
Heat Insulating Material
Easy Cleaning and Filter Change Aluminium
Filter can be conveniently changed and cleaned.
Main Body
Duct to OA 4 /5
https://www.lg.com/uk/business/air-conditioning-systems LG Air Conditioning and Energy Solutions UK 2020
Duct Connection Flange
INDOOR _ VENTILATION SOLUTIONS _ SPECIFICATION
ERV
LZ-H025GBA4 / LZ-H035GBA5
LZ-H050GBA5
Accessories
Chassis LZ-H025GBA4 LZ-H035GBA5 LZ-H050GBA5
Drain Pump -
Cassette Cover -
Refrigerant Leakage Detector -
EEV Kit -
Independent Power Module -
Robot Cleaner -
Pre Filter (washable) -
Ion Generator -
CO2 Sensor ○
Ventilation Kit -
IR Receiver -
Zone Controller -
PDRYCB000 (1 point contact)
Dry Contact (with additional accessory)
PDRYCB500 (Modbus)
External Input (1 point) -
Wi-Fi -
Accessories
Chassis LZ-H080GBA5 LZ-H100GBA5 LZ-H150GBA5 LZ-H200GBA5
Drain Pump -
Cassette Cover -
Refrigerant Leakage Detector -
EEV Kit -
Independent Power Module -
Robot Cleaner -
Pre Filter (washable) -
Ion Generator -
CO2 Sensor ○
Ventilation Kit -
IR Receiver -
Zone Controller -
PDRYCB000 (1 point contact)
Dry Contact (with additional accessory)
PDRYCB500 (Modbus)
External Input (1 point) -
Wi-Fi -
Cooling Heating
Exhaust Supply
Air Air
Outdoor Return
Air Air
Outdoor
Note : 1. Cooling Capacity Test condition - Indoor temperature : 27°C DB, 19°C WB / Outdoor temperature : 35°C DB
2. Heating Capacity Test condition - Indoor temperature : 20°C DB / Outdoor temperature : 7°C DB, 6°C WB
3. Humidifying capacity is based on the following conditions - Indoor temperature : 20°C DB, 15°C WB / Outdoor temperature : 7°C DB, 6°C WB
4. Cooling and heating capacities are based on the following conditions. : Fan is based on High and Super-high.
5. The operating sound measured at the point 1.5 m below the center of the unit is converted to that measured at an anechoic chamber.
6. The specifications, designs and information here are subject to change without notice.
Accessories
Chassis LZ-H050GXH4 LZ-H080GXH4 LZ-H100GXH4 LZ-H050GXN4 LZ-H080GXN4 LZ-H100GXN4
Drain Pump -
Cassette Cover -
Refrigerant Leakage Detector PRLDNVS0
EEV Kit -
Independent Power Module -
Robot Cleaner -
Pre Filter (washable) -
Ion Generator -
CO2 Sensor AHCS100H0
Ventilation Kit -
IR Receiver -
Zone Controller -
PDRYCB000 (1 point contact)
Dry Contact (with additional accessory)
PDRYCB500 (Modbus)
External Input (1 point) ○
Wi-Fi -
8 /9