0% found this document useful (0 votes)
369 views1 page

3a Bulk Water Meter GRE Connection Installation in Chamber Drawing PEW STD AMI 004 Rev3

The document provides details on the general arrangement of meter chambers within block paving areas including meter chamber dimensions and clearances. It specifies the dimensions for different meter sizes and configurations including the total length, width, and clearances required.

Uploaded by

Soly Seven
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
369 views1 page

3a Bulk Water Meter GRE Connection Installation in Chamber Drawing PEW STD AMI 004 Rev3

The document provides details on the general arrangement of meter chambers within block paving areas including meter chamber dimensions and clearances. It specifies the dimensions for different meter sizes and configurations including the total length, width, and clearances required.

Uploaded by

Soly Seven
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

NOTES:

GENERAL ARRANGEMENT OF METER CHAMBERS WITHIN BLOCKPAVING AREAS Refer Bulk Water Meter Installation in Chamber-GRE Connection-Guidelines-Rev3-01.03.2022

METER CHAMBER DIMENSION


CLEARANCE CLEARANCE AT
SPIGOT BETuVEEN BOTH SIDES OF
WATER INLET CHAMBER
METER STRAINE OUTLET FLANGE SOCKET ABD METER IN CHAMBER
VARIES METER VALVE TOTAL LENGTH METER WIDTH TOTAL WIDTH COVER
(L) R (L) VALVE (L) ADAPTOR (L) CHAMBER WIDTH FROM DIMENSION
100 100 SIZE (LI DIMENSION
100 200 VARIES 200 100
F WALLS (L) CHAMBER
G WALLS
CONCRETE/BRICK CEMENT SCREED OVER EXTERIOR BLOCK WORK SURFACES (INLET SIDE+ (INLETSIDE+
A B C D E (200+200) H I (Minimum) (Minimum)
SUPPORT FOR BOTH

200 100 100


150X150X100MM OUTLETSIDE OUTLETSIDE B+C+D+E+F+G)
IP68 PVC JB VALVES
50 178 200 300 178 - 250+250(500) 1356 400 110 510 1400X700 900X600
2 NO.S 25mmØ CPVC CONDUIT
FOR COMMUNICATION
80 203 200 350 203 - 250+300(550) 1506 400 140 540 1600X700 900X600

HDPE BOX 200X200X200 RECESSED 100 229 250 350 229 260+260(520) 150+150(300) 1878 400 165 565 2000X700 900X600
IN INTERLOCK PAVED AREA
150 267 300 500 267 270+270(540) 150+150(300) 2174 400 220 620 2200X700 1100X600
TO LV/ELECTRICAL ROOM THRUST BLOCK FOR ELBOW
900

90° ELBOW SMART


WATER METER NON RETURN VALVE 200 292 350 SOD 292 260+260(520) 150+150(300) 2254 400 280 680 240DX700 1100X600
GRE ELBOW 90° TO
DOUBLE FLANGED
G F A RISE OUTLET PIPE


BOTH SIDES F G 300 300 330 SOD SOD 330 260+260(520) 200+200(400) 2580 400 375 775 2600X800 1100X600
300 (DOUBLE FLANGED)
A *

VARIES
ALLUNITSAREIN MM
M
TO CONSUMER
STORAGE TANK

B B
FLOW OF WATER

CONSUMER SIDE VALVE


SPIGOT FLANG (FOR MAINTENANCE PURPOSE)

l
ADAPTOR

THRUST BLOCK G F B C D E F G

200
FOR ELBOW CLASS 20/10/S SOLID CONCRETE BLOCKWORK WALLS
VARIES

WALL
GRE SPOOL
DOUBLE FLANGED Note: Size of the pipeline connected after the meter should be the same size

100
DOUBLE FLANGED
BURIED
10MM NEOPRENE
MEMBRANS 2 GATE VALVE SUMP PIT of the meter until it reaches to the Consumer Tank.
GATE VALVE 300x300x150mm
LAYERS SLIP AND
DOUBLE FLANGED STRAINER
MASTIC SEALANT CLASS 20/10/S SOLID CONCRETE
AS SPECIFIED BLOCKWORK SUPPORT WITH
GRP LADDER CEMENT MORTAR 1:3
SOCKET
GATE VALVE
DOUBLE FLANGED STRAINER SPIGOT FLANGE ADAPTOR
GRE SPIGOT
SOCKET ELECTRO
FLANG ADAPTOR GATE VALVE
MAGNETIC WATER
METER DOUBLE FLANGED
GRE 'T' TWO SIDE MAIN LINE
SPIGOT ONE SIDE
FLANGED
VALVE AND FLOW METER ARRANGEMENT
PLAN
M.S.CHEQURED PLATE COVER

CEMENT MORTAR(1:3) BEDDING


TO BLOCKPAVING
LIFTING HOOKS TO BE SEALED 10 THK.CEMENT MORTAR (1:3) SEATING
WITH CEMENT MORTAR (1:3) FOR MANHOLE COVER METER SIZE, METER CAPACITY AND STORAGE TANK REQUIREMENTS
AFTER PLACING

HDPE BOX 200x200x200 Pipe Size to be


Metll!r Capacity/
Connected Storage Tank Requirement
BLOCKPAVING LEVEL CLASS 30/20/S PRECAST CONCRETE Meter Quantity of Water Storage Tank
Between the for Labor Accommodation
COVER SLAB Size the Meter can Requirement for Standard
Meteir and and other High
(mm) Deliver in 24 Hours Reside ntia I Premises
Storage Tank. Consumption Premises
(Imperial Gallons)
(mm)

Equivalent to 24 Hours EquiYalentto 48 Hours


50 40,000 50
Ø12 @ 200 BOTH WAY TOP&BOTTOM Consumption Coosumption
PVC CONDUIT
50mm THK.CEMENT MORTAR (1:3) SEATING
25MM CPVC CONDUIT FOR PRECAST CONCRETE COVER SLAB CONSUMER SIDE VALVE Equivalent to 24 Hours Equlvalentto 48 Hours
TO LV ROOM FOR METER NON RETURN VALVE (FOR MAINTENANCE PURPOSE) 80 10 □ ,oao 80
WATER PROOFING MEMBRANE 150X150X100MM Consumption Coosumption
COMMUNICATION 15mm THICK PLASTERING
AND PROTECTION BOARD IP68 PVC JB
AS SPECIFIED FINISHED SMOOTH
VARIES

CLASS 20/10/S SOLID Equivalent to 24 Hours EquiYalentto 48 Hours


100 1s□ ,o □ o 100
CONCRETE BLOCKWORK WALLS STRAINER Consumption Coosumption
TO CONSUMER
SEE NOTE NO.11 WATER METER POINTING INSIDE STORAGE TANK
BOTH SIDES *
300 300 Equivalent to 24 Hours EquiYalentto 48 Hours
150 350,000 150
Consumption Coosumption

THRUST BLOCK FOR ELBOW


VARIES

FLOW OF Equivalent to 24 Hours EquiYalentto 48 Hours


GRE ELBOW 90° TO RISE 200 750,000 200
WATER
300

OUTLET PIPE Consumption Coosumption


DOUBLE FLANGED
PROTECTIVE SCREED
200

GRE SPIGOT Equivalent to 24 Hours Equivalent to 48 Hours


FLANG ADAPTOR 300 1,500,000 300
50

CLASS 20/20/S CONCRETE BLINDING Consumption Coosumption


75

CONCRETE SUPPORT BELOW WATER PROOFING MEMBRANE


GAP BETWEEN BLOCKWORK
AND PIPE TO BE STRAINER WITH
RUBBER PACKING CLASS 30/20/S RC BOTTOM SLAB
SEALED AS SPECIFIED
2 LAYERS SLIP MEMBRANE BETWEEN CONCRETE/BRICK SUPPORT
Ø12 @ 200 SUPPORT AND CHAMBER FLOOR FOR BOTH VALVES WITH
BOTH WAY
TOP & BOTTOM RUBBER PACKING

SECTION 'A-A'
CEMENT MORTAR(1:3) BEDDING M.S.CHEQURED PLATE COVER M.S.CHEQURED PLATE COVER
TO BLOCKPAVING
10 THK.CEMENT MORTAR (1:3) SEATING 10 THK.CEMENT MORTAR (1:3) SEATING
FOR MANHOLE COVER FOR MANHOLE COVER
LIFTING HOOKS TO BE SEALED
WITH CEMENT MORTAR (1:3) CHAMBER COVER FRAME TO BE BOLTED CHAMBER COVER FRAME TO BE BOLTED
AFTER PLACING TO THE PRECAST CONCRETE COVER SLAB TO THE PRECAST CONCRETE COVER SLAB

BLOCKPAVING LEVEL CLASS 30/20/S PRECAST CONCRETE BLOCKPAVING LEVEL CLASS 30/20/S PRECAST CONCRETE
COVER SLAB COVER SLAB

4`Y' 12`L' SHAPPED


TRIMMER BARS TOP & BOTTOM

RE.'/. DATE DR'N BY CH'D BY AP'D BY DESCRIPTION

WATER PROOFING MEMBRANE


AND PROTECTION BOARD
AS SPECIFIED
Ø12 @ 200
BOTH WAY
TOP&BOTTOM
50mm THK.CEMENT MORTAR (1:3)
SEATING FOR PRECAST CONCRETE COVER SLAB
Ø12 @ 200
BOTH WAY
TOP&BOTTOM Y16 @ 200
rill.., J~r-4 w.a
DUBAI ELECTRICITY & WATER AUTHORITY
Q
VARIES

VARIES

WATER PROOFING MEMBRANE


CLASS 20/10/S SOLID G.R.P LADDER AND PROTECTION BOARD P.O.BOX: 564, DUBAI - U.A.E., FAX :324 4922, TEL : 324 4444
15mm THICK PLASTERING FINISHED SMOOTH GOVERNMENT OF DUBAI
CONCRETE BLOCKWORK WALLS
SEE NOTE NO.11
AS SPECIFIED Y12 @ 200
r---
llPARIIIENT:
POINTING INSIDE 30/20/S REINFORCED CONCRETE WALL

..,,
DD ( J ~r--- - DOOR HINGES PROJECTS & ENGINEERING (WATER)
TEL 04-3220003, EMAIL: [email protected]
WATER STOPER
SUMP PIT 300x300x150mm
CONSTRUCTION JOINT
I `Y '12@150 c/c
ffiOJECf:
I BOTHWAYS TOP & BOTTOM
300 Slope 300 Slope
AMI (ADVANCED METERING INFRASTRUCTURE)
75 50 200

75 50 200

• • • • WATER METER INSTALLATION


300

300

PROTECTIVE SCREED

CLASS 20/20/S CONCRETE BLINDING CLASS 20/20/S CONCRETE BLINDING

GRP FITTING AS SPECIFIED WATER PROOFING MEMBRANE WATER PROOFING MEMBRANE


- 200MM DIA CIRCULAR CI
COVER FOR VALVE
~ STEEL CHAMBER COVER 1lllE:
AMI - WATER
CLASS 30/20/S RC BOTTOM SLAB
SECTION 'B-B' CLASS 30/20/S RC BOTTOM SLAB
BULK WATER METER INSTALLATION IN CHAMBER
Ø12 @ 200
BOTH WAY SECTION 'B-B' 2 LAYERS SLIP MEMBRANE
Ø12 @ 200
2 LAYERS SLIP MEMBRANE REINFORCEMENT DETAILS
TOP & BOTTOM BETWEEN SUPPORT AND CHAMBER FLOOR
BOTH WAY
TOP & BOTTOM STEEL DETAIL IN CASE OF RCC WALL BETWEEN SUPPORT AND CHAMBER FLOOR ( 50MM TO 300MM DIA. GRE CONNECTION)
PREPARED BY: :f~af,-,- CHECKED BY: .,A..5/m.'i~ SCALE: N.T.S

AMI 2" to 12" BULK WATER METER (GRE CONNECTION) INSTALLATION IN CHAMBER DESIGNED BY: :f.,,JJ,J,,.. APPROVED BY: :JJ"""',
DRAWING NO:
DATE: 27.04.2022
REV
PEW-STD-AMI-004 3