0% found this document useful (0 votes)
82 views5 pages

Mu PT 2018 Rod

This document calculates the measurement uncertainty for determining the compressive strength of concrete, mortar, and grout samples. It summarizes test parameters like applied load, sample dimensions, and calculated compressive strength. It then analyzes sources of uncertainty like instrument precision and variability in measurements. The combined standard uncertainty is 0.8739 N/mm^2 and the expanded uncertainty with a coverage factor of 2 is 1.7 N/mm^2. This provides an estimated range of values that could be expected for the true compressive strength.

Uploaded by

ammy
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
82 views5 pages

Mu PT 2018 Rod

This document calculates the measurement uncertainty for determining the compressive strength of concrete, mortar, and grout samples. It summarizes test parameters like applied load, sample dimensions, and calculated compressive strength. It then analyzes sources of uncertainty like instrument precision and variability in measurements. The combined standard uncertainty is 0.8739 N/mm^2 and the expanded uncertainty with a coverage factor of 2 is 1.7 N/mm^2. This provides an estimated range of values that could be expected for the true compressive strength.

Uploaded by

ammy
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 5

SOIL INSTRUMENTS (M) SDN BHD

CALCULATION OF MEASUREMENT UNCERTAINTY Report No: MU/EOS/MTS/18/006


TEST NAME : Admixture for Concrete, Mortar and Grout

Date Updated 10/9/2018


Report Ref: SIM/MTS/PT/CS/0001/28d Updated by Nurul Azira

compressive Symbol Formula Value


strength 42.99
Test Parameters Symbol Trial 1 Trial 2 Trial 3 Test Data St.Dev σ σ = F*1000/(LW)
Load Applied (kN) F 935 994 992 974 33.50 CF dσ/dF = 1000/(LW) 0.044
Sensitivity
Length (mm) L 150 150 150 150.00 0.000 CL dσ/dL = -1000F/(L2W) -0.287
Coefficient
Width (mm) W 152 150 151 151.00 1.000 CW dσ/dW = -1000F/(LW2) -0.285
Compressive Strength(N/mm²) σ 43.0

Distribution Type of Sensitivity


Component of Uncertainty Source symbol Range/st.dev Divisor/Dist. Std. Uncty UiCi (UiCi)2 DoF νi (UiCi)4/νi %contribution
Type evaluation Coefficient

Applied Load (kN)-observation machine UA(F) normal A 33.50 1.732 19.3420 0.044 0.8539 0.7292 2 0.26588778912 95.49
Applied Load (kN) - calibration cal. Cert machine Ucal(F) normal B 3.9 2.0000 1.9500 0.0442 0.0861 0.0074 60 9.156181E-07 0.97
Applied Load(kN) - resolution cal. Cert machine Ures(F) rectangular B 0.1 1.7321 0.0577 0.0442 0.0025 0.0000 infinity 0 0.00
Length (mm) - repeatability vernier UA(L) normal A 0.000 1.7321 0.0000 -0.2866 0.0000 0.0000 2 0 -
Length(mm) - calibration vernier Ucal(L) normal B 0.01 2.0000 0.0050 -0.2866 -0.0014 0.0000 60 7.0263878E-14 0.00
Length(mm) - resolution vernier Ures(L) rectangular B 0.01 1.7321 0.0058 -0.2866 -0.0017 0.0000 infinity 0 0.00
Width (mm) - repeatability vernier UA(W) normal A 1.000 1.7321 0.5774 -0.2847 -0.1644 0.0270 2 0.00036491195 3.54
Width (mm)-calibration vernier Ucal(W) normal B' 0.01 2.0000 0.0050 -0.2847 -0.0014 0.0000 60 6.8420991E-14 0.00
Width(mm)-resolution vernier Ures(W) rectangular B 0.01 1.7321 0.0058 -0.2847 -0.0016 0.0000 infinity 0 0.00
Unit
Unit N/mm2 or MPa SUM 0.7637 (N/mm2)2
Note: 1N/mm² = 1MPa Combined Uncertainty 0.8739 N/mm2
Effective DoF. & K 2.19
Equipment ID No (Compressive Machine): SIM/HQ/E/0195 Uncertainty based on SAMM & ILAC , K= 2.01
k 2
Equipment ID No (Caliper): SIM/HQ/E/0288 Expanded Uncertainty (±) 1.7 N/mm2

Prepared By: Checked By:


SOIL INSTRUMENTS (M) SDN BHD
CALCULATION OF MEASUREMENT UNCERTAINTY Report No : MU/EOS/MTS/18/004b

Test name: Compressive and Flexural Strength of Prismatic Test Specimens from Cement Mortar Date Updated : 10/9/2018
Updated by : Nurul Azira

Report Ref: SIM/MTS/ILC/CFS/CM/0001/28d - 0003/28d

Max Load Compressive


Sample I.D Weight (kg) Depth Width (kN) Strength (MPa) Quantity Symbol Equation Value
ILC/C 0004-1-1 0.57 41 40 87.6 54.8 Compressive Strength σ σ=F/(DW) 53.1
ILC/C 0004-1-2 0.57 41 40 83.9 52.4
ILC/C 0004-2-1 0.57 40 40 86.8 54.3 Sensitivity Coeff. (Load) CF dσ/dF=1000/(DW) 0.625
ILC/C 0004-2-2 0.57 40 40 85.6 53.5
ILC/C 0004-3-1 0.57 41 40 84.9 53.1
ILC/C 0004-3-2 0.57 41 40 86.7 54.2
ILC/C 0005-1-1 0.58 40 40 87.5 54.7
ILC/C 0005-1-2 0.58 40 40 86.9 54.3
ILC/C 0005-2-1 0.59 40 40 81.8 51.1
ILC/C 0005-2-2 0.59 40 40 80.5 50.3
ILC/C 0005-3-1 0.59 40 40 81.4 50.9
ILC/C 0005-3-2 0.59 40 40 81.9 51.2
ILC/C 0006-1-1 0.57 41 40 87.6 54.8
ILC/C 0006-1-2 0.57 41 40 83.1 51.9
ILC/C 0006-2-1 0.57 41 40 86.6 54.1
ILC/C 0006-2-2 0.57 41 40 85.5 53.4
ILC/C 0006-3-1 0.58 40 40 85.6 53.5
ILC/C 0006-3-2 0.58 40 40 85.2 53.3
Average 86 53.1
Standard Deviation 2.3 1.4

Uncertainty Calculation for: Compressive Strength

Component Symbol Unit Evaluation Dist. Range/st dev. Divisor/factor std. Ui Ci (UiCi)2 νi (CiUi)4/νi % contribution
Repeatability: Load (F) UA(F) kN A normal 2.3 4.24 0.55 0.625 0.1161 5 0.00269447297165 28.190
Calibration: Compression Machine Ucal(F) kN B normal 1.74 2 0.87 0.625 0.295664 60 0.00145695396423 71.807
Resolution: Machine Ures(F) kN B rectangular 0.01 1.73 0.01 0.625 0.000013 infinity 0 0.003
Unit
SUM 0.4117
UC 0.64 MPa
Eff Dof 40.84
SAMM req., k = 2
Equipment ID No (Compressive Machine): SIM/HQ/E/0326a k 2
UE (±) 1.3 MPa

Prepared By:
Checked By:
SOIL INSTRUMENTS (M) SDN BHD Report No : MU/EOS/MTS/18/005
CALCULATION OF MEASUREMENT UNCERTAINTY
Date Updated : 10/9/2018
Test name: Determination of Cement Fineness By Air Permeability Updated by : Nurul Azira
(Blaine Method)

Report Ref: SIM/MTS/ILC/CF/BM/0001

Quantity Unit Trial 1 Trial 2 Trial 3 Average St. Dev


Mass of cell+filter paper+disk (m1) g 68.83 68.83 68.83 68.83
mass of sample+cell+filter paper+disk (m2) g 71.85 71.88 71.86 71.86
Mass of sample (m3) g 2.79 2.79 2.79 2.79
ρ of sample g/cm3 2.99 2.99 2.99 2.99
ρ0 of ref. cement g/cm3 3.15 3.15 3.15 3.15
t s 70 68 67 68.33 1.53
t0 s 93 93 93 93
Specific Surface S cm2/g 3490 3439 3414 3448

Quantity Symbol Equation Value


Specific Surface S (ρ0*√t*S0)/(ρ*√t0) 3447.72
Sens. Coeff t Ct 1/2*(ρ0*S0)/(ρ*√t*√t0) 25.23

Note: S0= 3818cm2/g

Uncertainty Calculation for: Specific Surface

Ci (UiCi)2 (CiUi)4/νi % cont.


Component Symbol Unit Evaluation Dist. Range/st dev. Divisor/factor std. Ui νi
Repeated Observation: Time UA(t) s A normal 1.53 1.732050807569 0.881917104 25.23 495.028910749 2 122526.811 75.67
Calibration: Stopwatch Ucal(t) s B normal 1 2 0.5 25.23 159.116435598 60 421.967335 24.32
Resolution: Stopwatch Ures(t) s B rectangular 0.01 1.732050807569 0.005773503 25.23 0.02121552475 infinity 0 0.00

Unit
SUM 654.1666
UC 25.5767 cm2/g
Eff DoF 3.48
Based on SAMM & ILAC, k = 2
Equipment ID No (Stopwatch): SIM/HQ/E/0361 k 2
UE (±) 51.2 cm2/g

Prepared By:
Checked By:
SOIL INSTRUMENTS (M) SDN BHD Report No : MU/EOS/MTS/18/008
CALCULATION OF MEASUREMENT UNCERTAINTY
Date Updated : 10/9/2018
Test name: Determination of Residue by Oven Drying Updated by : Nurul Azira
(Liquid Admixture)

Report Ref: SIM/MTS/PT/ADM/ROD/0001-0003

Quantity Trial 1 Trial 2 Trial 3 Average St. Dev Quantity Symbol Equation Value
m2, mass of stoppered bottle with sand (g) 56.185 60.215 59.315 58.6 2.115 Residue by Oven Drying %m (m4-m2)/(m1-m2)*100 19.8
m1, mass of stoppered bottle with sand & sample (g) 60.365 64.245 62.74 62.5 1.956 Sens. Coeff m1 Cm1 100(m4-m2)/(m1-m2)2 -5.10
m3, mass of sample (m2-m1) (g) 4.18 4.03 3.425 3.9 Sens. Coeff. m2 Cm2 100(m4-m1)/(m1-m2)2 20.69
m4, mass of stoppered bottle with sand & dry residue (g) 57.005 60.995 60.015 59.3 2.07928673668 Sens. Coeff. m4 Cm4 100/(m1-m2) -25.78
m5 = m4 - m2 (g) 0.82 0.78 0.7 0.8
Residue by Oven Drying (m 5/m3)*100% 19.6 19.4 20.4 19.8 0.565

Uncertainty Calculation for: Residue by Oven Drying

Component Symbol Unit Evaluation Dist. Range/st dev. Divisor/factor std. Ui Ci (UiCi)2 νi (CiUi)4/νi % contribution
Repeated Observation: (%m) UA(%m) % A normal 0.565 1.732 0.3262 1.00 0.10642 2 0.00566278507 99.39
Calibration: Weighing Balance(m 1) Ucal(m1) g B normal 0.001 2 0.0005 -5.10 0.00001 60 7.0306265E-13 0.01
Resolution: weighing balance (m 1) Ures(m1) g B rectangular 0.001 1.732 0.0006 -5.10 0.00001 infinity 0 0.01
Calibration: Weighing Balance (m 2) Ucal(m2) g B normal 0.001 2 0.0005 20.69 0.00011 60 1.9078313E-10 0.10
Resolution: weighing balance (m 2) Ures(m2) g B rectangular 0.001 1.732 0.0006 20.69 0.00014 infinity 0 0.13
Calibration: Weighing Balance (m 4) Ucal(m4) g B normal 0.001 2 0.0005 -25.78 0.00017 60 4.604137E-10 0.16
Resolution: weighing balance (m 4) Ures(m4) g B rectangular 0.001 1.732 0.001 -25.78 0.00022 infinity 0 0.21
Unit
SUM 0.1071 (N/mm2)2
UC 0.3272 N/mm2
Based on SAMM, k = 2
Eff DoF 2.02
Equipment ID No (weighing balance): SIM/HQ/E/0262 k 2
UE (±) 0.7 %

Prepared By: Checked By:


SOIL INSTRUMENTS (M) SDN BHD
CALCULATION OF MEASUREMENT UNCERTAINTY Report No : MU/EOS/MTS/18/004a

Test name: Compressive and Flexural Strength of Prismatic Test Specimens from Cement Mortar Date Updated : 10/9/2018
Updated by : Nurul Azira

Report Ref: SIM/MTS/ILC/CFS/CM/0001/2d - 0003/2d

Max Load Compressive


Sample I.D Weight (kg) Depth Width (kN) Strength (MPa) Quantity Symbol Equation Value
ILC/C 0001-1-1 0.58 41 40 61.5 38.4 Compressive Strength σ σ=F/(DW) 36.1
ILC/C 0001-1-2 0.58 41 40 63.2 39.5
ILC/C 0001-2-1 0.58 41 40 64.4 40.3 Sensitivity Coeff. (Load) CF dσ/dF=1000/(DW) 0.625
ILC/C 0001-2-2 0.58 41 40 60.1 37.6
ILC/C 0001-3-1 0.57 41 40 63.0 39.4
ILC/C 0001-3-2 0.57 41 40 64.1 40.1
ILC/C 0002-1-1 0.57 41 40 56.1 35.1
ILC/C 0002-1-2 0.57 41 40 54.4 34.0
ILC/C 0002-2-1 0.57 41 40 53.3 33.3
ILC/C 0002-2-2 0.57 41 40 46.1 28.8
ILC/C 0002-3-1 0.57 41 40 53.5 33.4
ILC/C 0002-3-2 0.57 41 40 53.7 33.6
ILC/C 0003-1-1 0.57 41 40 57.5 35.9
ILC/C 0003-1-2 0.57 41 40 59.3 37.1
ILC/C 0003-2-1 0.58 41 40 62.6 39.1
ILC/C 0003-2-2 0.58 41 40 53.7 33.6
ILC/C 0003-3-1 0.57 41 40 57.5 35.9
ILC/C 0003-3-2 0.57 41 40 56.9 35.6
Average 61 36.1
Standard Deviation 4.9 3.1

Uncertainty Calculation for: Compressive Strength

Component Symbol Unit Evaluation Dist. Range/st dev. Divisor/factor std. Ui Ci (UiCi)2 νi (CiUi)4/νi % contribution
Repeatability: Load (F) UA(F) kN A normal 4.9 4.24 1.16 0.625 0.5213 5 0.05435886847348 63.810
Calibration: Compression Machine Ucal(F) kN B normal 1.74 2 0.87 0.625 0.295664 60 0.00145695396423 36.188
Resolution: Machine Ures(F) kN B rectangular 0.01 1.73 0.01 0.625 0.000013 infinity 0 0.002
Unit
SUM 0.8170
UC 0.90 MPa
Eff Dof 11.96
SAMM req., k = 2
Equipment ID No (Compressive Machine): SIM/HQ/E/0326a k 2
UE (±) 1.8 MPa

Prepared By:
Checked By: