0% found this document useful (0 votes)
83 views18 pages

Covna Electric Wafer Butterfly Valve Catalog

Uploaded by

hafiz ashidqi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
0% found this document useful (0 votes)
83 views18 pages

Covna Electric Wafer Butterfly Valve Catalog

Uploaded by

hafiz ashidqi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
You are on page 1/ 18
COVNA® — VALVE — Electric Soft sealing Butterfly Valve Introduction ‘According tothe sealing performance, pneumatic butertly valve can be cvided into metal seal and soft seal ype. Advantages pneumatic butterfly valve over other type valves may inlude:compact structure, miniature siz, long servise life, good sealing performance, easy maintenance, quick detachable and installation. Electric Actuator Feedback: the Active Contact Sigal, Passive Contact Sigal, Resistance, 420A, Input & Output Signa: DC 4-20mA, DC 0-10V, DC 1-5 “The Field, Remote Control Switch Regulation and MODBUS, PROFIBUS Fie Bus ‘AC110-240V S80V 50/60H2; DC12V, DC24V, Special Voltage Canbbe Customized a '88, C1, Ductile on, WOB Sey con vron ere Water Flange Storie Stee! eines ‘Conta of Water. Ar, Gas, l,i, Steam Midi Structure /A-yp0 ‘Qutine Size drawing UNIT: mm Etc Reece | Byres ew ew : ee ee ee) tt Hi 96 = 104127153 180206270 320368428 4820S, : v2 125° 145-160 180210 240295985 410470 525885. i Mo 6 &® 8 8 mm wm wm tT BO 22 as 250 2m) SOs foo Ha hak ton ok Hn aso ee tn NE 82 86 02 89 02 7 me ee am Installation Instruction, 1. When removing the valve from storage, @ careful check should be made to ensure that the va has not been damaged during the storage period. 2. Valve open or clase positon is indicated on the notch plate fr levar operated valves or an the top ofthe gear operator for gear operator operated valves, 3.. Center valve, span body with bots, but donot tighten. Slowly open disc to ensure that it clears ‘adjacent pipe ID and leave at full open position. 4. Forflange welding center valve with disc 10 open between flanges, span bolts, align this assembly In pipe and tack weld flanges to pipe. After tack wolding, remove valve and finish welding, 5. Valve should be checked foridentifcation purpose and ensure that characteristic of valve matches to those spect for piping specications forthe line where thats to be mounted. Nameplate Instructions will give the necessary information. COVNA® — VALVE — Electric Soft sealing Butterfly Valve Introduction. According to the sealing performance, pneumatic butertly valve can be cvided into metal soft seal type. Advantages pneumatic butterfly valve over other type valves may include:compact structure, miniature size, long servise life, good sealing performance, easy maintenance, ‘Quick detachable and instalation. Electric Actuator FFeodback: the Actve Contact ional, Passive Contact Sional, Resistance, 4-20mA Input & Output Signal: DC 4-20mA, DC O-10V, DC 1.5 “The Feld, Remote Control Switch Regulation and MODBUS, PROFIBUS Feld Bus ‘AC110-240V 980V S0'60Hz; DC12V, DC24V, Special Votage Cane Customized p65; Explosion Proof Construption Ave Acailabe: EX dl BT NBR, EPDM, VITON, PTFE ET staiess sice! = b ed «= ons BE seers te tine Size drawing owen BM ose es ee er ee i+ BIN 2) es rea so os 7 mas 205 we ma awe wie BB wt we em me ano Erm 125 14s 100 100 210 402055517 i 445555 HSS IS | ee ee a Ey es tn Hom som om 4423 4023 anes aia som 4-026 4800 ra 5.2 56 7.2 89 1039 17 18 28 505 Baiada CCIE COR CONE CONRNA CORRA COUN CoN CORBA CORA Cot CORA Installation Instruction 41. When removing the valve from storage, a careful check should be made to ensure thatthe valve has not been damaged during the storage period, 2.. Valve open or close position is indicated on the notch plate for lever operated valves or onthe top ‘ofthe gear operator for gear operator operated valves. 3. Center valve, span body wit bolts, but donot tighten. Slowly open disc to ensure that it clears adjacent pipe ID and leave at fll open postion. 4, For lange welding center valve with disc 10 open between flanges, span bolts, align this assembly In pipe and tack weld flanges to pipe. After tack welding, remove valve and finish welding. 5, Valve should be checked for identification purpose and ensure that characteristics of valve matches {those specified for piping specications, forthe line where thats to be mounted. Nameplate instructions will give the necessary information COVNA® — VALVE — Main Functions and Key Features 1, Body: body material is hard aluminum alloy, which is treated by hard anodic oxdization and coated by Polyester powder, so that it has great corrosion resistance and protection class is IP67. 2, Motor: fully enclosed cage type motor is small in size and inertia, large in torque. Insulation class is F grade which can prevent motor over-heating; 3. Manual Override: small handle is reliable, energy-saving. It can be used for manual operation when electricity is off; In automatic operation, it can be fixed inside the clip for easy operation; 4. Indicator: indicator is assembled on center axis, valve position can be observed; Outside mirror design facilitates position observation and prevents water drops accumulation; 5. Enclosure: high sealing performance, standard protection class is IP67; 6. Limit Switches: mechanical and electronic position limit switches.Mechanica stop Iscrew can be adjustable; Electronic limit switches can be controlled by cam.Position can be set easily and accurately by simply adjusting the cam without any influence by handle; 7. Self Lock: accurate turbo-worm structure can output large torque with high efficiency and little noise (Max. 50 decibel). Service life is quite long. Its self lock function can stop reverse rotation. Drive part is stable and reliable without additional lubrication; 8. Captive Bolt: bolts won't fall off when cover is disassembled; 9. Application: bottom connection complies with 1S05211/DIN3337 Standard. Star square hole is easy for square valve stem linear or 45° rotation application; Both vertical and horizontal assemble are available; 10. Diagram: control diagram complies with single phase or three phase wiring standard, reasonable wiring diagram and connection terminal can meet requirement of other optional functions. COVNA’® — VALVE — Outline Size Dimension COVNA-05 178 0 copmnae © Orxi2 AY 4 29. nn seh Oisxis AY 18 COVNA® — VALVE — Outline Size Dimension COVNA-30/60 OD covna.z50 170 30x30» le 148 8-M10 TOL COVNA® — VALVE — Specification Performance Characteristics Of Electric Actuator Resfortnianoe Model 0s 10 16 30 60 125 250 400 Angle of Rotation | 0-80" 0-90" 0-90" 0~90° 0-90" 0-90" 0-90" 0-90" Torque Output | soNm | 100Nm | t60Nm | 300Nm | 600Nm | 1250Nm | 2500Nm | o00NM 90° cycleTime | aS ‘sse08e08 xene: | ioe || moa || ons Working Current) o2aa | o3sa | 0402 | o4sa | o60d | 00a | 185A | 278 acz20v t cvs, Drive Motor | sow | 7sw | sow — roow | asow | 2iow | zesw | scow Voltage Options | aczanv, acttov, ac2ev Control Circuit | 8: ON/OFF Type with Passive Contact Signal Feedback Torque Output | 60Nm | 110m | 170Nm | sa0Nm | 680Nm | 130m | 2500Nm 90° Cycle Time as ns "WS 9s 358 328 2s | StartingCurrent | o74a | 14a | 14a | ea | 70a | 38a | 434 oe _Meting Curent) oaen | oata | o4an | 10a | o70n | 120 14a scveta rive Motor | gsw | sow | sow | sow | sow | aow | sow Voltage Options | perv, oc2av,0cr0v, Dcz20v Control Circuit | F:DC24V/ DC12V Direct ON/OFF Type Torque Output | 70Nm 100Nen 200Nm_ ‘300Nm_ 600Nm | 1300Nm | 2500Nm 90°cycleTime 20s aS 28 ee) 505 Starting Current | 0.204 | 028A 0.308 055A 0.45, 0.604 077A Working Current| 0164 | o25a | 27a | ost | O4aA | O65A | 075A ACBEOV, Drive Motor sw row | zw oir | aaow sow | 103W Voltage Options | AC3B0V Control Circuit Protection Class ‘Ambient Temp. Installation Angle Electrical Connection G: AC380V Three-Phase Power Supply with Passive Signal Feedback (Default) H: AC380V Three-Phase Power Supply with Resistance Potentiometer Signal Feedback 165 =20°C-+00%C Any 61/2 Water proof Cable Connectors, letrc Power Wie, Signal Wire (Optional) "Note: Can'tconnect ane actuator parallel with other ones, nother words, can't se the same controler contact points to control two and above actuators, ‘otherwise t wllcost out of contre, motor overheating, product damage and shorter service if ® COVINA’ Specification — VALVE — ON/OFF Type Performance characteristics {COVA HX Series the on-off actuator has only two actions (Jor 90} when performing valve operations, which means thatthe valve can only be fully open ‘or fut dosed. Can not conto the amplitude ofthe valve switch, and cannot control the medium flow. The on-of vahe is generally used to switch of the ‘wo positions, There ae two postions of ull open and full losed, The functions to open or close to conduct and ato the working medium inside, ‘Tere isno special requirement forthe flow characteristics, but forthe switching speed, Te leakage requirement higher than that of the regulating valve. Voltage Options ACI TOV, ACZ20V, ACSBOV, DZAV, ACAV Insulation Resistance 100MA/500V Withstand Voltage | 1500V; 1min 'A-ON/OFF Type with Light indicator Signal Feedback B: ON/OFF Type with Passive Contact Signal Feedback ‘C-ON/OFF Type with Resistance Ptentiometer Signal Feedback ON/OFF Type with Resistance Potentiometer and Neutral Postion Signal Feedback Regulation Type with Servo Control Modile F:DC24V/ DC12V Direct ON/OFF Type ‘6:AC380V Three-Phase Power Supply with Passive Signal Feedback H:AC3BQW Three Phase Power Supply with Resistance Potentiometer Signal Feedback Control Cireuit Optional Function Over Torque Protectors, Dehumisify Heater, Stainless Steel Coupling & Yoke Regulation type Performance characteristics CCOVNA HK Series the regulation type electric actuator has the function ofa switch ype integrated structure, and relatively increase thentllgent control ‘module, 502s to accurately control the valve (any angle between 0°90}, adjust the medium flow, and control by input or output The signal 4-20mA or 0-204/1'5vcan conto the opening of the valve; the performance reflects the contol accuracy the control accuracy is generally within 18 ofthe eros, and the opening and flow an be adjusted very acaurately, Voltage Options | ACTIOV, ACZ20V, ACSBOV, DC24V, ACZAV Input Signal | 4-20mADG 1-SvDC 0-10VOC Output Signal | 4 2omaDe1-SVDC_0-10VDC Tolerance 205% Return Difference | <0.3% DeadZone | O.1%10 1.6% Damping Characteristics | 0 Mechanical RepeatatiltyError | OF "Note: can'tconnect ane actuator gaalel with other ones, nother words, can't use the same cortro-lr contact points to contre two and above actuators, ‘otherwise illest out of conto, motor overheating, preduct damage and shorter sevice if, COVNA® — VALVE — Wiring Diagram ‘A; ONIOFF Type Light indicator Signal Feedback Function:Finish open or close operations by the circuit, and the actuator outputs a signal of active position (full opening, full closing) C: ON/OFF Type with Resistance Potentiometer Signal Feedback Function:Control the open angle of valves by circuit, and the actuator outputs the resistance signal corresponding to the position of switch Structure: with 5000 or 10009. potentiometer Caution: © Fullclose Signal © Full open signal B: ON/OFF Type with Passive Contact Signal Feedback Function: Finish open or close operations by the circuit, and the actuator outputs a set signal of passive position (full opening, full closing) Structure: with two neutral positions switches © FullClose Signal © Full Open Signet and Neutral Position Signal Feedback Function: control the open angle of valves by circuit, and the actuator outputs the resistance signal corresponding to the position of open position, at the same time, outputting a set signal of passive position Structure: both potentiometer style and neutral positions switch style Can't connect one actuator parallel with other ones, in other words, can't use the same control -ler contact points to control two and above actuators, otherwise it will cost out of control, motor overheating, product damage and shorter service life. COVNA® — VALVE — Wiring Diagram E: Regulation Type with Servo Control Module Function: Modulating, input & output DC4-20mA, 1-5VDC, 0-10VDC Structure: With servo control module and 10009 potentiometer G: AC380V Three-Phase Power Supply with Passive Signal Feedback Function: The external circuit make positive and negative conversion of DC power to open or close, | and the actuator outputs a set signal of passive position (full opening, full closing) Notes: Please kindly note ifthe switch position is correct when the three phase electric actuators being adjusted, its opposite direction, then make 2 of powerlines exchange each other Caution: F: DC24V/ DC12V Direct ON-OFF Type Function: The external circuit make positive and negative conversion of DC power to open or close, and the actuator outputs a set signal of passive position (full opening, full closing} H: AC380V Three-Phase Power Supply with Resistance Potentiometer Signal Feedback Function: The external circuit make positive and. negative conversion of DC power to open or close, and the actuator outputs a set signal of passive position (full opening, full closing) Notes: Please kindly noe i he switch positon is correct when the three phase electric actuators being adjusted, ifi’s ‘opposite direction, then make 2 of powerlines exchange each other Can't connect one actuator parallel with other ones, in other words, can't use the same control er contact points to control two and above actuators, otherwise it will cost out of control, motor overheating, product damage and shorter service life. COVNA® — VALVE — Operation C ( # 4 5 9 Construction 1 | shot 4 | Rubbercap 7 | Electro Cover 2 | Position indicator 5 | Output shat 8 | TeminalBox 3 | net Wire Lock 6 | GearBox Cover 9 | Manual Overide The actuator are fully debugged before they go out, if they don't meet your demands because of the valve body, the coupling in actual installation. Please resume debugging according to following steps: 3 @ Assembly the actuator to the valve (refer to Installation) © Discharge the electric cover of actuator and debug as following steps according to the actual state of valve: © Adjustment of limit position switch (refer to Commissioning); @ Adjustment of neural position switch (refer to Commissioning) @ Adjustment of regulation type actuator (only for E style, refer to Commissioning of regulation type actuator}; @ Adjustment of mechanical limited location block (refer to Commissioning). © The manual test run ) Take off the rubber cap of manual handle hole; inset the hand shank into hole and rotate it clockwise decreased valve opening, ® Check whether the limit switch is running or not when the valve is full closing position (sensitive switch making crack sound when itis running), then turn the adjusting screw a half turn to check ifthe screw could touch the ‘mechanical limited location block @® Tum hand shank anticlockwise to increase valve opening, check the situation of limit switch and mechanical limit location block the same method, make trial tum to see whether they are allright. @ The electric test run @ Take off terminal box, wiring correctly according to wiring diagram ® Separately turn on the power on clockwise and anticlockwise and see whether the actuator and the valve are working correctly.) The direction of shut point (clockwise) show close, the direction of open point (anticlockwise) show open, 10 COVNA*® — VALVE — Installation 1. Installation environment + The product can be installed indoor and outdoor. « product is non-explosion-proof production, and the installation must be avoided being in flammable or explosive environment etc. + The actuator should be in protection box in the environment of long-term with the splash of rain, material and direct sunlight. « Please reserve space for controller, manual operation, + The surrounding environment temperature should be In -30°C~+60°C 2. Temperature of working medium ‘+ When matching with the vaive, the actuator body's temperature will a bit rise if medium temperature happen heat transfer. « Ifthe temperature of medium is high, the bracket has the function of reducing heat conduction. Coupings «+ Please select the standard bracket if temperature of working medium below 60°C. «* Please select the standard bracket when temperature of working medium above 60°C. 3. Installed on the valve body (Figure 3) ‘* Manually operate the actuator to drive the valve, confirm it does not have abnormal situation. Turn the valve in ful closed position. «Assemble the bracket tothe valve body. += Setone end of coupings on valve spindle. + Tum the electric actuator to full closing position, and insert output-input shaft into the square holes of couplings. + Setthe screw between the electric actuator and bracket « Tum actuator by hand shank, confirm that it moves translation, no eccentric, «Figure 3 no skew and no overrun, 4. Cable installation + Install wire tubes as shown in Figure 4. «The outside diameter of wire tubes should be 29-211 * Take measures to proof water. + To prevent actuator from flowing into wire tubes water, the actuation position should higher than wire tubes postion. «When installing wire, the outside diameter of wire should be 9-211 « As figure 5, in case the water flow into actuator interior from line locking, all wire that are not allowed to be used + The signal wire should be shielded wire in principle, don't paral it to — Figure 4 Special tips + Caution: can't connect one actuator parallel with one another, in other words, can't use the same controller contact point to control more than one actuator, otherwise it will use out of control, motor overheating, product damage, shorter service life « Ifthe actuator is installed outdoor, we suagest equipping other protective cover to proof water, stabilize mechanical property, make allonger service life. 6. Power voltage: 220VAC S0Hz/60Hz 7. Guard line options for witch of cutting-off winding —1- "nn Bracket Valve Body to” 1 the Coaxalty ofA and 820.2 Cable Wire Lock Nut Cable Joint Tem Guard Line | Motor Power WiF 05 3A 10 1016 BA 25, 30 30160 7A 40,90 125/250/400 104, 100, 120, 140 Figure 5 1 COVNA*® — VALVE — Installation Assembly Drawing Bracket @ Z type bracket and couplings (match with 05) @ S type bracket and couplings (match with 10/16) 22, 35 18 “J @ M type bracket and couplings (match with 10/16) 12 COVNA® — VALVE — Commissioning 1. Adjustment of limit position switch (Figure 6) ‘Axis of Rotation Peisot Rotation / Sensitive Switch (© Tum the valve to full opening position by hand. @ Loosen the screw of travel block and turn the block to Full Opening drive the travel switch, then fine-tuning sensitive switch Full Closing Until hearing "click", after that, set screw. (@ The way of adjustment ull opening position is the same Travel Block as above, (Figure 6) 2. Adjustment of middle position switch (Figure 7) @ Use hand shank to drive the vaive to the position it need. @ Loosen the screw of travel block and turn the travel blOCK 2 position Axis of Rotation to drive sensitive switch, then set screw. Middle Position | Senstive Sunch © These two neutral position switches’ position could be Qoen| adjusted according to need. Coss tees : . . avelBlod 3. Adjustment of potentiometer (Figure 8) (@ Use hand shank to drive actuator to neutral position, and turn (Figure 7) the pointer point to 50% scale line. © Use multimeter to test resistance of first and third port of potentiometer (resistance between the first port and third port in potentiometer), and mark R (potentiometer defauitis 1&0 +15% if no special request). © Separate potentiometer gear from the opening gear by suitable external force on potentiometer fixing plate © Putone probe of multimeter to one potentiometer terminal, the other probe to another terminal, then rotate potentiometer gear and see number in multimeter. When the resistance value is equivalent to R/2 #20, stop rotating, after that, mesh these two gears. 4. Adjustment of mechanical limit location block (Figure 9) @ Use hand shank to drive valve to full opening position and operate the switch (sensitive switch makes crack ‘sound when itis running). © Loosen the nut and tur the adjusting screw to touch the mechanical limit location block, then turn the adjust -ing screw a half tum back, set nut. ‘© Adjusting the full opening position by the same way as above. Potentiometer Extension Spring Potentiomater Gear ‘Sot Nut Aonaseories Sha Potentiomotor Fixing Plate Adjusting Serew Opening Gear, Mechanical Limit Location Block Potentiomater (Figure 8) (Figure 9) 13 COVNA® — VALVE — Commissioning of Regulation Type Actuator 1. Function of electrical limit and mechanical limi @ Electrical stroke limit function: ‘When the actuator reaches at fully openedifully closed or the middle position, the built-in electrical limit switch will cutoff the circuit to protect the actuator, ® Mechanical limit function of output shaft: When electrical stroke limit function fails, output shaft Will be locked by mechanical limit to protect the valve from damage. Figure 10 shows the position relationship between electrical limit and mechanical limit. 2. Adjustment of actuator (Figure 10) @® Adjust the over-travel limit stopper to zero position and full position, and ensure electrical limit position angle is 90” @® Adjust mechanical position limitation base on electrical limit position angle. 3. Connection of actuator with servo control module meter installation and connection (Figure 11) Potent @ Finish potentiometer installation and connection according to "Commission in previous chapter. @® Use multimeter to check resistance of potentiometer in middle opening position, and ensure ithas homogeneous continuous variable from 0-100% opening. Electrical Limit White con Electrical Limit (Fully Opened) (FullyCiosod) Red j= av (Rotating Termiina) Meohaniea Limit Black ‘Mechanical Lim (Fully Oponea) (FulyClosed) (Figuret0) (Figure 11) Electrical wiring of the servo control module (Figure 12) Positioner Junction Facet | he Internal Positioner | Slclens BeeasgseEea Saas pan a t+ +4 rt 4-20mA 4-20mA AC 220V Re | RE cov ostov a ElectricActuator 100% (Figure 12) 14 COVNA® — VALVE — Commissioning of Regulation Type Actuator 1] OPEN | Ouiputcontrlopen® , une [2 [SHUT [Ouiputconiar enue Module Operating Interface Siz MANU _| Manual control satus AUTO | Autovcnirl statue ‘le e|: ‘Operating by clockse, he input signlis corresponding a ase 5 | ORTA | todmAsutposion (usualy we calibrate tt be uit openin) 20mA-zer0 poston (usualy we stitio be fl lsing ale e|. pe a) uur Lael hie) sro ‘Operating by anticlockwise, theinpat signals coresponding 6 | RvSA | toama-t poston (usualy we sete be ful open), eo °,° 2omAcroro poston (usvaby we ealiae to bel losing) a “rvaat) “open ‘stop “shut _PRTA) Input opening signalto make the actuator open to maximum J 7 | OPEN | opening doareo 8 | STOP | Inputstopping signal to make the actuator stop running Input shutting signal io make te acluator shut minimum 9 | SHUT | closing degree “Aulomatc or manual mode toggle Key, parameter change and 10] AIM | togale kay Values increase bull, tus for switching display original won | ‘| & | setdogresofopening uhenits'n automate mods, opening We BEC Acton whenita mati mode ‘Values deoroase button, i's use fr witching dlapay tothe 12| ¥ | temperature of vale positioner shell when in automate mace 4. Zero Calibration After wiring between valve positioner and actuator like Figure 12, the rotation angle has to be calibrated in the first match between positioner and actuator, after that the positioner could work correctly, the demarcation has no effect on input and output of valve positioner. Method one: simple automatic calibration (this method request the actuator has electric limit position stopper and mechanical limit position stopper). In the automatic mode, press both A/M and buttons at the ‘same time, then release these two buttons at the same time, the actuator will start automatic calibration ‘and confirm the zero position (full closing) first. The valve runs to the small angle direction and reaches, at minimal opening position which is judged as zero position (valve position 0.0). After that the actuator runs to maximum opening direction and reaches at maximum opening position which is judged as full position (valve position 100.0). After judgment, the actuator returns to automatic calibration and saves results by itself. Method two: calibrate your need (this method request button idle time less than 8 seconds in the progress of calibration). In the automatic mode, press A/M button into uO parameter, pass u1, u2, u3, ud and into us, revise u5=003.1, finally press A/M button. D Enter u6, press & or ¥ button to make actuator to run to "open" or "shut" direction, meanwhile, the screen shows the situation of actual valve opening degree is increasing or decreasing. If the opening arrival at Zero position that it's your expected position (you can see it if actuator is already assembled valve body, and the valve is set in full closing position in general), press A/M button to confirm it, enter U7 parameter. ® Inu? parameter, press 4 or ¥ to run to your expected full position in the same way, and press A/M to Confirm full position (you can see it If actuator is already assembled valve body, and the valve is setin full opening position in general), then back to uS. ® Revise u-00.5 and back to measurement and control status. 15 COVNA® — VALVE — Operation Flow Chart Actuator runs to opening direction Display setting signal | Press A( Measurement and Press a of pening degree onirolstatus —_Press AM Manual status Display actual valve Dispayhetemperatre | 7) Shing dope ef vv postionr shall 1 press J Bepsomaie fers secone =n Roviso S000 5 press AM Press both AIM ans ¥ to make achuator start automatic calibration Methodtwo Method one fU5=0003:1 ‘enter zer0 and full position calibration PressAM ur (Calibrate full postion) Press Nilo back oS ‘Actuator runs to closing direction Poleatiometer in Measurement and Press WM _| ys=000.5 according button tobelow operational steps U0-U7 parameter are changed by and ¥ NOTE: Each parameters of regulation type actuator have already been calibrated before A. _(22ving factory. Do not altorit unless it must. If really do, please read it carefully before commissioning. 16 COVNA® — VALVE — Troubleshooting 5. Error message and solution Error Code Meaning - For example, the signal of zero postion is ealbrate to be Am, butthe given current <3.0mA. ‘The actuator wil start signal interupt handler and show E-01 in screen 03 Signal feedback lines of valve positioner and actuator are inversely connected > Switch lines are inversely connect “The actuator has large oscillation because of input signal or feedback signal unstable, 100 hi es 3rg@ oscillation because of input signal or feedback signal unstable, to high precision, ete £06 “The actuatorisnt able to open direction E07 The actuatorisnt able to run to shut direction 08 ‘The Internal temperature of positioners higher then 80°C Maintenance ® No extra oil required because the molybdenum grease we put are with long service life and high with- stand voltage. ® Please take periodical inspection to the actuator if you don't use it frequently. Troubleshooting Faultphenomenon | Possible reason Solution Lacking of power supply Connect the actuator to power supply Electric wire broken, wiring terminals loose | Repairthe wig, ighton wiring terminals ‘Supply voltage is wrong or below level Check the voltage is correct or wrong Motor does not start ‘Overheat protector activated (ambient Reduce ambient temperature, manually temperature is to high, the valves stuck) _| openvclose the vaive to see fits working Limit switch eistunction Replace the limit switch ‘Capacitance dossrit start or runing ‘Replace the capacitance Indicator ightis broken Replace the indicator light Opening & closing Indicatorlightdoesrit | Limit switch istuncion Replace the limit switch light ‘Adjusting of block disfunction Readjustment ‘Signal source has interference signal Check input signal Opening degree chang. ‘Voltage divider generated interference Replace the potentiometer ing constantly Voltage divider gear or opening gearlaose | Tightening up the screws of gear 17 eee anes COVNA Headquarter: Building C, Longchang Micro-Chuangyuan, No. 26 Hantang Street, Dongcheng District, Dongguan City, China, 523000 E-mail: [email protected] Tel: 86-769-22456666 22763199 Fax: 86-769-22825120 www.covnavalve.com www.covnaactuator.com

You might also like