— VALVE — Electric Soft sealing Butterfly Valve
Introduction
‘According tothe sealing performance, pneumatic butertly valve can be cvided into metal seal and
soft seal ype. Advantages pneumatic butterfly valve over other type valves may inlude:compact
structure, miniature siz, long servise life, good sealing performance, easy maintenance,
quick detachable and installation.
Electric Actuator
Feedback: the Active Contact Sigal, Passive Contact Sigal, Resistance, 420A,
Input & Output Signa: DC 4-20mA, DC 0-10V, DC 1-5
“The Field, Remote Control Switch Regulation and MODBUS, PROFIBUS Fie Bus
‘AC110-240V S80V 50/60H2; DC12V, DC24V, Special Voltage Canbbe Customized
a
'88, C1, Ductile on, WOB
Sey con vron ere
Water Flange Storie Stee!
eines ‘Conta of Water. Ar, Gas,
l,i, Steam
Midi Structure /A-yp0
‘Qutine Size drawing UNIT: mm
Etc Reece |
Byres ew ew :
ee ee ee) tt
Hi 96 = 104127153 180206270 320368428 4820S, :
v2 125° 145-160 180210 240295985 410470 525885. i
Mo 6 &® 8 8 mm wm wm tT
BO 22 as 250 2m) SOs
foo Ha hak ton ok Hn aso ee tn NE
82 86 02 89 02 7 me ee am
Installation Instruction,
1. When removing the valve from storage, @ careful check should be made to ensure that the va
has not been damaged during the storage period.
2. Valve open or clase positon is indicated on the notch plate fr levar operated valves or an the top
ofthe gear operator for gear operator operated valves,
3.. Center valve, span body with bots, but donot tighten. Slowly open disc to ensure that it clears
‘adjacent pipe ID and leave at full open position.
4. Forflange welding center valve with disc 10 open between flanges, span bolts, align this assembly
In pipe and tack weld flanges to pipe. After tack wolding, remove valve and finish welding,
5. Valve should be checked foridentifcation purpose and ensure that characteristic of valve matches
to those spect for piping specications forthe line where thats to be mounted. Nameplate
Instructions will give the necessary information.COVNA®
— VALVE — Electric Soft sealing Butterfly Valve
Introduction.
According to the sealing performance, pneumatic butertly valve can be cvided into metal
soft seal type. Advantages pneumatic butterfly valve over other type valves may include:compact
structure, miniature size, long servise life, good sealing performance, easy maintenance,
‘Quick detachable and instalation.
Electric Actuator
FFeodback: the Actve Contact ional, Passive Contact Sional, Resistance, 4-20mA
Input & Output Signal: DC 4-20mA, DC O-10V, DC 1.5
“The Feld, Remote Control Switch Regulation and MODBUS, PROFIBUS Feld Bus
‘AC110-240V 980V S0'60Hz; DC12V, DC24V, Special Votage Cane Customized
p65; Explosion Proof Construption Ave Acailabe: EX dl BT
NBR, EPDM, VITON, PTFE
ET staiess sice!
=
b
ed «= ons
BE seers te
tine Size drawing owen
BM ose es ee er ee i+
BIN 2) es rea so os 7 mas 205 we ma awe wie
BB wt we em me ano
Erm 125 14s 100 100 210 402055517 i
445555 HSS IS
| ee ee a
Ey es tn Hom som om 4423 4023 anes aia som 4-026 4800
ra 5.2 56 7.2 89 1039 17 18 28 505
Baiada CCIE COR CONE CONRNA CORRA COUN CoN CORBA CORA Cot CORA
Installation Instruction
41. When removing the valve from storage, a careful check should be made to ensure thatthe valve
has not been damaged during the storage period,
2.. Valve open or close position is indicated on the notch plate for lever operated valves or onthe top
‘ofthe gear operator for gear operator operated valves.
3. Center valve, span body wit bolts, but donot tighten. Slowly open disc to ensure that it clears
adjacent pipe ID and leave at fll open postion.
4, For lange welding center valve with disc 10 open between flanges, span bolts, align this assembly
In pipe and tack weld flanges to pipe. After tack welding, remove valve and finish welding.
5, Valve should be checked for identification purpose and ensure that characteristics of valve matches
{those specified for piping specications, forthe line where thats to be mounted. Nameplate
instructions will give the necessary informationCOVNA®
— VALVE —
Main Functions and Key Features
1, Body: body material is hard aluminum alloy, which is treated by hard anodic oxdization
and coated by Polyester powder, so that it has great corrosion resistance and protection
class is IP67.
2, Motor: fully enclosed cage type motor is small in size and inertia, large in torque.
Insulation class is F grade which can prevent motor over-heating;
3. Manual Override: small handle is reliable, energy-saving. It can be used for manual
operation when electricity is off; In automatic operation, it can be fixed inside the clip
for easy operation;
4. Indicator: indicator is assembled on center axis, valve position can be observed;
Outside mirror design facilitates position observation and prevents water drops
accumulation;
5. Enclosure: high sealing performance, standard protection class is IP67;
6. Limit Switches: mechanical and electronic position limit switches.Mechanica stop
Iscrew can be adjustable; Electronic limit switches can be controlled by cam.Position
can be set easily and accurately by simply adjusting the cam without any influence
by handle;
7. Self Lock: accurate turbo-worm structure can output large torque with high efficiency
and little noise (Max. 50 decibel). Service life is quite long. Its self lock function can
stop reverse rotation. Drive part is stable and reliable without additional lubrication;
8. Captive Bolt: bolts won't fall off when cover is disassembled;
9. Application: bottom connection complies with 1S05211/DIN3337 Standard. Star
square hole is easy for square valve stem linear or 45° rotation application; Both
vertical and horizontal assemble are available;
10. Diagram: control diagram complies with single phase or three phase wiring standard,
reasonable wiring diagram and connection terminal can meet requirement of other
optional functions.COVNA’®
— VALVE — Outline Size Dimension
COVNA-05
178
0
copmnae ©
Orxi2 AY 4
29. nn
seh
Oisxis AY
18COVNA®
— VALVE — Outline Size Dimension
COVNA-30/60
OD covna.z50
170 30x30» le
148 8-M10
TOLCOVNA®
— VALVE — Specification
Performance Characteristics Of Electric Actuator
Resfortnianoe Model 0s 10 16 30 60 125 250 400
Angle of Rotation | 0-80" 0-90" 0-90" 0~90° 0-90" 0-90" 0-90" 0-90"
Torque Output | soNm | 100Nm | t60Nm | 300Nm | 600Nm | 1250Nm | 2500Nm | o00NM
90° cycleTime | aS ‘sse08e08 xene: | ioe || moa || ons
Working Current) o2aa | o3sa | 0402 | o4sa | o60d | 00a | 185A | 278
acz20v t
cvs, Drive Motor | sow | 7sw | sow — roow | asow | 2iow | zesw | scow
Voltage Options | aczanv, acttov, ac2ev
Control Circuit | 8: ON/OFF Type with Passive Contact Signal Feedback
Torque Output | 60Nm | 110m | 170Nm | sa0Nm | 680Nm | 130m | 2500Nm
90° Cycle Time as ns "WS 9s 358 328 2s |
StartingCurrent | o74a | 14a | 14a | ea | 70a | 38a | 434
oe _Meting Curent) oaen | oata | o4an | 10a | o70n | 120 14a
scveta rive Motor | gsw | sow | sow | sow | sow | aow | sow
Voltage Options | perv, oc2av,0cr0v, Dcz20v
Control Circuit | F:DC24V/ DC12V Direct ON/OFF Type
Torque Output | 70Nm 100Nen 200Nm_ ‘300Nm_ 600Nm | 1300Nm | 2500Nm
90°cycleTime 20s aS 28 ee) 505
Starting Current | 0.204 | 028A 0.308 055A 0.45, 0.604 077A
Working Current| 0164 | o25a | 27a | ost | O4aA | O65A | 075A
ACBEOV, Drive Motor sw row | zw oir | aaow sow | 103W
Voltage Options | AC3B0V
Control Circuit
Protection Class
‘Ambient Temp.
Installation Angle
Electrical Connection
G: AC380V Three-Phase Power Supply with Passive Signal Feedback (Default)
H: AC380V Three-Phase Power Supply with Resistance Potentiometer Signal Feedback
165
=20°C-+00%C
Any
61/2 Water proof Cable Connectors, letrc Power Wie, Signal Wire
(Optional)
"Note: Can'tconnect ane actuator parallel with other ones, nother words, can't se the same controler contact points to control two and above actuators,
‘otherwise t wllcost out of contre, motor overheating, product damage and shorter service if®
COVINA’ Specification
— VALVE —
ON/OFF Type Performance characteristics
{COVA HX Series the on-off actuator has only two actions (Jor 90} when performing valve operations, which means thatthe valve can only be fully open
‘or fut dosed. Can not conto the amplitude ofthe valve switch, and cannot control the medium flow. The on-of vahe is generally used to switch of the
‘wo positions, There ae two postions of ull open and full losed, The functions to open or close to conduct and ato the working medium inside,
‘Tere isno special requirement forthe flow characteristics, but forthe switching speed, Te leakage requirement higher than that of the regulating valve.
Voltage Options ACI TOV, ACZ20V, ACSBOV, DZAV, ACAV
Insulation Resistance 100MA/500V
Withstand Voltage | 1500V; 1min
'A-ON/OFF Type with Light indicator Signal Feedback
B: ON/OFF Type with Passive Contact Signal Feedback
‘C-ON/OFF Type with Resistance Ptentiometer Signal Feedback
ON/OFF Type with Resistance Potentiometer and Neutral Postion Signal Feedback
Regulation Type with Servo Control Modile
F:DC24V/ DC12V Direct ON/OFF Type
‘6:AC380V Three-Phase Power Supply with Passive Signal Feedback
H:AC3BQW Three Phase Power Supply with Resistance Potentiometer Signal Feedback
Control Cireuit
Optional Function Over Torque Protectors, Dehumisify Heater, Stainless Steel Coupling & Yoke
Regulation type Performance characteristics
CCOVNA HK Series the regulation type electric actuator has the function ofa switch ype integrated structure, and relatively increase thentllgent control
‘module, 502s to accurately control the valve (any angle between 0°90}, adjust the medium flow, and control by input or output The signal 4-20mA or
0-204/1'5vcan conto the opening of the valve; the performance reflects the contol accuracy the control accuracy is generally within 18 ofthe eros,
and the opening and flow an be adjusted very acaurately,
Voltage Options | ACTIOV, ACZ20V, ACSBOV, DC24V, ACZAV
Input Signal | 4-20mADG 1-SvDC 0-10VOC
Output Signal | 4 2omaDe1-SVDC_0-10VDC
Tolerance 205%
Return Difference | <0.3%
DeadZone | O.1%10 1.6%
Damping Characteristics | 0
Mechanical
RepeatatiltyError | OF
"Note: can'tconnect ane actuator gaalel with other ones, nother words, can't use the same cortro-lr contact points to contre two and above actuators,
‘otherwise illest out of conto, motor overheating, preduct damage and shorter sevice if,COVNA®
— VALVE —
Wiring Diagram
‘A; ONIOFF Type
Light indicator Signal Feedback
Function:Finish open or close operations by
the circuit, and the actuator outputs a signal of
active position (full opening, full closing)
C: ON/OFF Type with
Resistance Potentiometer Signal Feedback
Function:Control the open angle of valves by
circuit, and the actuator outputs the resistance
signal corresponding to the position of switch
Structure: with 5000 or 10009. potentiometer
Caution:
© Fullclose Signal
© Full open signal
B: ON/OFF Type with
Passive Contact Signal Feedback
Function: Finish open or close operations by
the circuit, and the actuator outputs a set signal
of passive position (full opening, full closing)
Structure: with two neutral positions switches
© FullClose Signal
© Full Open Signet
and Neutral Position Signal Feedback
Function: control the open angle of valves by
circuit, and the actuator outputs the resistance
signal corresponding to the position of open
position, at the same time, outputting a set signal
of passive position
Structure: both potentiometer style and neutral
positions switch style
Can't connect one actuator parallel with other ones, in other words, can't use the same control
-ler contact points to control two and above actuators, otherwise it will cost out of control, motor
overheating, product damage and shorter service life.COVNA®
— VALVE —
Wiring Diagram
E: Regulation Type with Servo Control Module
Function: Modulating, input & output
DC4-20mA, 1-5VDC, 0-10VDC
Structure: With servo control module and
10009 potentiometer
G: AC380V Three-Phase
Power Supply with Passive Signal Feedback
Function: The external circuit make positive and
negative conversion of DC power to open or close, |
and the actuator outputs a set signal of passive
position (full opening, full closing)
Notes:
Please kindly note ifthe switch position is correct when
the three phase electric actuators being adjusted, its
opposite direction, then make 2 of powerlines exchange
each other
Caution:
F: DC24V/ DC12V Direct ON-OFF Type
Function: The external circuit make positive
and negative conversion of DC power to open
or close, and the actuator outputs a set signal
of passive position (full opening, full closing}
H: AC380V Three-Phase Power Supply
with Resistance Potentiometer Signal Feedback
Function: The external circuit make positive and.
negative conversion of DC power to open or close,
and the actuator outputs a set signal of passive
position (full opening, full closing)
Notes:
Please kindly noe i he switch positon is correct when
the three phase electric actuators being adjusted, ifi’s
‘opposite direction, then make 2 of powerlines exchange
each other
Can't connect one actuator parallel with other ones, in other words, can't use the same control
er contact points to control two and above actuators, otherwise it will cost out of control, motor
overheating, product damage and shorter service life.COVNA®
— VALVE — Operation
C ( #
4
5 9
Construction
1 | shot 4 | Rubbercap 7 | Electro Cover
2 | Position indicator 5 | Output shat 8 | TeminalBox
3 | net Wire Lock 6 | GearBox Cover 9 | Manual Overide
The actuator are fully debugged before they go out, if they don't meet your demands because
of the valve body, the coupling in actual installation. Please resume debugging according to
following steps: 3
@ Assembly the actuator to the valve (refer to Installation)
© Discharge the electric cover of actuator and debug as following steps according to the actual state
of valve:
© Adjustment of limit position switch (refer to Commissioning);
@ Adjustment of neural position switch (refer to Commissioning)
@ Adjustment of regulation type actuator (only for E style, refer to Commissioning of regulation type actuator};
@ Adjustment of mechanical limited location block (refer to Commissioning).
© The manual test run
) Take off the rubber cap of manual handle hole; inset the hand shank into hole and rotate it clockwise decreased
valve opening,
® Check whether the limit switch is running or not when the valve is full closing position (sensitive switch making
crack sound when itis running), then turn the adjusting screw a half turn to check ifthe screw could touch the
‘mechanical limited location block
@® Tum hand shank anticlockwise to increase valve opening, check the situation of limit switch and mechanical
limit location block the same method, make trial tum to see whether they are allright.
@ The electric test run
@ Take off terminal box, wiring correctly according to wiring diagram
® Separately turn on the power on clockwise and anticlockwise and see whether the actuator and the valve
are working correctly.) The direction of shut point (clockwise) show close, the direction of open point
(anticlockwise) show open,
10COVNA*®
— VALVE — Installation
1. Installation environment
+ The product can be installed indoor and outdoor.
« product is non-explosion-proof production, and the installation must be avoided being in flammable or explosive
environment etc.
+ The actuator should be in protection box in the environment of long-term with the splash of rain, material and
direct sunlight.
« Please reserve space for controller, manual operation,
+ The surrounding environment temperature should be In -30°C~+60°C
2. Temperature of working medium
‘+ When matching with the vaive, the actuator body's temperature will a
bit rise if medium temperature happen heat transfer.
« Ifthe temperature of medium is high, the bracket has the
function of reducing heat conduction. Coupings
«+ Please select the standard bracket if temperature of working
medium below 60°C.
«* Please select the standard bracket when temperature of working
medium above 60°C.
3. Installed on the valve body (Figure 3)
‘* Manually operate the actuator to drive the valve, confirm it does not
have abnormal situation. Turn the valve in ful closed position.
«Assemble the bracket tothe valve body.
+= Setone end of coupings on valve spindle.
+ Tum the electric actuator to full closing position, and insert output-input
shaft into the square holes of couplings.
+ Setthe screw between the electric actuator and bracket
« Tum actuator by hand shank, confirm that it moves translation, no eccentric, «Figure 3
no skew and no overrun,
4. Cable installation
+ Install wire tubes as shown in Figure 4.
«The outside diameter of wire tubes should be 29-211
* Take measures to proof water.
+ To prevent actuator from flowing into wire tubes water, the
actuation position should higher than wire tubes postion.
«When installing wire, the outside diameter of wire should be 9-211
« As figure 5, in case the water flow into actuator interior from line locking,
all wire that are not allowed to be used
+ The signal wire should be shielded wire in principle, don't paral it to
— Figure 4
Special tips
+ Caution: can't connect one actuator parallel with one another, in other words, can't use the same controller contact
point to control more than one actuator, otherwise it will use out of control, motor overheating, product damage,
shorter service life
« Ifthe actuator is installed outdoor, we suagest equipping other
protective cover to proof water, stabilize mechanical property, make
allonger service life.
6. Power voltage: 220VAC S0Hz/60Hz
7. Guard line options for witch of cutting-off winding
—1- "nn
Bracket
Valve Body
to”
1 the Coaxalty ofA and 820.2
Cable Wire
Lock Nut
Cable Joint
Tem Guard Line | Motor Power WiF
05 3A 10
1016 BA 25, 30
30160 7A 40,90
125/250/400 104, 100, 120, 140 Figure 5
1COVNA*®
— VALVE —
Installation
Assembly Drawing
Bracket
@ Z type bracket and couplings (match with 05)
@ S type bracket and couplings (match with 10/16)
22,
35
18 “J
@ M type bracket and couplings (match with 10/16)
12COVNA®
— VALVE — Commissioning
1. Adjustment of limit position switch (Figure 6)
‘Axis of Rotation
Peisot Rotation
/ Sensitive Switch
(© Tum the valve to full opening position by hand.
@ Loosen the screw of travel block and turn the block to Full Opening
drive the travel switch, then fine-tuning sensitive switch Full Closing
Until hearing "click", after that, set screw.
(@ The way of adjustment ull opening position is the same
Travel Block
as above, (Figure 6)
2. Adjustment of middle position switch (Figure 7)
@ Use hand shank to drive the vaive to the position it need.
@ Loosen the screw of travel block and turn the travel blOCK 2 position Axis of Rotation
to drive sensitive switch, then set screw. Middle Position | Senstive Sunch
© These two neutral position switches’ position could be Qoen|
adjusted according to need. Coss tees
: . . avelBlod
3. Adjustment of potentiometer (Figure 8)
(@ Use hand shank to drive actuator to neutral position, and turn
(Figure 7)
the pointer point to 50% scale line.
© Use multimeter to test resistance of first and third port of
potentiometer (resistance between the first port and third port in potentiometer), and mark R (potentiometer
defauitis 1&0 +15% if no special request).
© Separate potentiometer gear from the opening gear by suitable external force on potentiometer fixing plate
© Putone probe of multimeter to one potentiometer terminal, the other probe to another terminal, then rotate
potentiometer gear and see number in multimeter. When the resistance value is equivalent to R/2 #20, stop
rotating, after that, mesh these two gears.
4. Adjustment of mechanical limit location block (Figure 9)
@ Use hand shank to drive valve to full opening position and operate the switch (sensitive switch makes crack
‘sound when itis running).
© Loosen the nut and tur the adjusting screw to touch the mechanical limit location block, then turn the adjust
-ing screw a half tum back, set nut.
‘© Adjusting the full opening position by the same way as above.
Potentiometer Extension Spring
Potentiomater Gear ‘Sot Nut
Aonaseories Sha Potentiomotor Fixing Plate
Adjusting Serew
Opening Gear,
Mechanical Limit Location Block
Potentiomater
(Figure 8) (Figure 9)
13COVNA®
— VALVE — Commissioning of Regulation Type Actuator
1. Function of electrical limit and mechanical limi
@ Electrical stroke limit function:
‘When the actuator reaches at fully openedifully closed or the middle position, the built-in electrical limit
switch will cutoff the circuit to protect the actuator,
® Mechanical limit function of output shaft:
When electrical stroke limit function fails, output shaft Will be locked by mechanical limit to protect the
valve from damage.
Figure 10 shows the position relationship between electrical limit and mechanical limit.
2. Adjustment of actuator (Figure 10)
@® Adjust the over-travel limit stopper to zero position and full position, and ensure electrical limit position
angle is 90”
@® Adjust mechanical position limitation base on electrical limit position angle.
3. Connection of actuator with servo control module
meter installation and connection (Figure 11)
Potent
@ Finish potentiometer installation and connection according to "Commission in previous chapter.
@® Use multimeter to check resistance of potentiometer in middle opening position, and ensure ithas
homogeneous continuous variable from 0-100% opening.
Electrical Limit White con
Electrical Limit
(Fully Opened)
(FullyCiosod)
Red
j= av (Rotating Termiina)
Meohaniea Limit Black
‘Mechanical Lim
(Fully Oponea)
(FulyClosed)
(Figuret0) (Figure 11)
Electrical wiring of the servo control module (Figure 12)
Positioner Junction Facet | he Internal Positioner |
Slclens BeeasgseEea
Saas pan a
t+ +4 rt
4-20mA 4-20mA AC 220V Re | RE
cov ostov a
ElectricActuator 100%
(Figure 12)
14COVNA®
— VALVE — Commissioning of Regulation Type Actuator
1] OPEN | Ouiputcontrlopen®
, une [2 [SHUT [Ouiputconiar enue
Module Operating Interface Siz
MANU _| Manual control satus
AUTO | Autovcnirl statue
‘le e|: ‘Operating by clockse, he input signlis corresponding
a ase 5 | ORTA | todmAsutposion (usualy we calibrate tt be uit openin)
20mA-zer0 poston (usualy we stitio be fl lsing
ale e|. pe a)
uur Lael hie) sro
‘Operating by anticlockwise, theinpat signals coresponding
6 | RvSA | toama-t poston (usualy we sete be ful open),
eo °,° 2omAcroro poston (usvaby we ealiae to bel losing)
a
“rvaat) “open ‘stop “shut
_PRTA)
Input opening signalto make the actuator open to maximum
J 7 | OPEN | opening doareo
8 | STOP | Inputstopping signal to make the actuator stop running
Input shutting signal io make te acluator shut minimum
9 | SHUT | closing degree
“Aulomatc or manual mode toggle Key, parameter change and
10] AIM | togale kay
Values increase bull, tus for switching display original
won | ‘| & | setdogresofopening uhenits'n automate mods, opening
We BEC Acton whenita mati mode
‘Values deoroase button, i's use fr witching dlapay tothe
12| ¥ | temperature of vale positioner shell when in automate
mace
4. Zero Calibration
After wiring between valve positioner and actuator like Figure 12, the rotation angle has to be calibrated
in the first match between positioner and actuator, after that the positioner could work correctly, the
demarcation has no effect on input and output of valve positioner.
Method one: simple automatic calibration (this method request the actuator has electric limit position
stopper and mechanical limit position stopper). In the automatic mode, press both A/M and buttons at the
‘same time, then release these two buttons at the same time, the actuator will start automatic calibration
‘and confirm the zero position (full closing) first. The valve runs to the small angle direction and reaches,
at minimal opening position which is judged as zero position (valve position 0.0). After that the actuator
runs to maximum opening direction and reaches at maximum opening position which is judged as full
position (valve position 100.0). After judgment, the actuator returns to automatic calibration and saves
results by itself.
Method two: calibrate your need (this method request button idle time less than 8 seconds in the
progress of calibration). In the automatic mode, press A/M button into uO parameter, pass u1, u2, u3,
ud and into us, revise u5=003.1, finally press A/M button.
D Enter u6, press & or ¥ button to make actuator to run to "open" or "shut" direction, meanwhile, the
screen shows the situation of actual valve opening degree is increasing or decreasing. If the opening
arrival at Zero position that it's your expected position (you can see it if actuator is already assembled
valve body, and the valve is set in full closing position in general), press A/M button to confirm it, enter
U7 parameter.
® Inu? parameter, press 4 or ¥ to run to your expected full position in the same way, and press A/M to
Confirm full position (you can see it If actuator is already assembled valve body, and the valve is setin
full opening position in general), then back to uS.
® Revise u-00.5 and back to measurement and control status.
15COVNA®
— VALVE — Operation Flow Chart
Actuator runs to
opening direction
Display setting signal | Press A( Measurement and Press a
of pening degree onirolstatus —_Press AM
Manual status
Display actual valve
Dispayhetemperatre | 7) Shing dope
ef vv postionr shall 1 press
J Bepsomaie
fers secone
=n
Roviso S000 5 press AM
Press both AIM ans ¥
to make achuator start
automatic calibration Methodtwo Method one
fU5=0003:1
‘enter zer0 and full
position calibration
PressAM
ur
(Calibrate full postion)
Press Nilo back oS
‘Actuator runs to
closing direction
Poleatiometer in
Measurement and
Press WM _| ys=000.5 according button
tobelow operational
steps
U0-U7 parameter are
changed by and ¥
NOTE: Each parameters of regulation type actuator have already been calibrated before
A. _(22ving factory. Do not altorit unless it must. If really do, please read it carefully
before commissioning.
16COVNA®
— VALVE — Troubleshooting
5. Error message and solution
Error Code Meaning
- For example, the signal of zero postion is ealbrate to be Am, butthe given current <3.0mA.
‘The actuator wil start signal interupt handler and show E-01 in screen
03 Signal feedback lines of valve positioner and actuator are inversely connected
> Switch lines are inversely connect
“The actuator has large oscillation because of input signal or feedback signal unstable, 100 hi
es 3rg@ oscillation because of input signal or feedback signal unstable, to high
precision, ete
£06 “The actuatorisnt able to open direction
E07 The actuatorisnt able to run to shut direction
08 ‘The Internal temperature of positioners higher then 80°C
Maintenance
® No extra oil required because the molybdenum grease we put are with long service life and high with-
stand voltage.
® Please take periodical inspection to the actuator if you don't use it frequently.
Troubleshooting
Faultphenomenon | Possible reason Solution
Lacking of power supply Connect the actuator to power supply
Electric wire broken, wiring terminals loose | Repairthe wig, ighton wiring terminals
‘Supply voltage is wrong or below level Check the voltage is correct or wrong
Motor does not start
‘Overheat protector activated (ambient Reduce ambient temperature, manually
temperature is to high, the valves stuck) _| openvclose the vaive to see fits working
Limit switch eistunction Replace the limit switch
‘Capacitance dossrit start or runing ‘Replace the capacitance
Indicator ightis broken Replace the indicator light
Opening & closing
Indicatorlightdoesrit | Limit switch istuncion Replace the limit switch
light
‘Adjusting of block disfunction Readjustment
‘Signal source has interference signal Check input signal
Opening degree chang. ‘Voltage divider generated interference Replace the potentiometer
ing constantly
Voltage divider gear or opening gearlaose | Tightening up the screws of gear
17eee anes