CENTRIFUGAL PUMP DATA SHEET
1 Note APPLICABLE TO: PROPOSAL APPLICABLE NTL/INTNTL STANDARD: API-610 Rev
2 FOR EXXON CORPORATION UNIT
3 SITE BEAUMONT TEXAS SERVICE Gasoline
4 NO. REQ 2 PUMP SIZE 8LPN21 TYPE BB1 No. STAGES 1
5
6 MANUFACTURER MODEL LPN SERIAL NO. 22HE0253
6 LIQUID CHARACTERISTICS
7 Units Maximum Minimum Note SERVICE : CONTINUOUS
8 LIQUID TYPE OR NAME : Gasoline Max & min values refer • IF INTERMITTENT NO. OF STARTS :
9 VAPOR PRESSURE : psia 3 only to the property PUMPS OPERATE IN:
10 RELATIVE DENSITY : SG 0.78 listed CORROSION DUE TO : (6.12.1.9)
11 SPECIFIC HEAT : Btu/(lbm-°F) EROSION DUE TO : (6.12.1.9)
12 VISCOSITY : SSU 32.5 H2S CONCENTRATION (ppm) : (6.12.1.12)
13 OPERATING CONDITIONS (6.1.2) CHLORIDE CONCENTRATION (ppm) :
14 Units Maximum Rated Normal Minimum PARTICULATE SIZE (DIA IN MICRONS)
15 NPSHa Datum: C.L. Impeller PARTICULATE CONCENTRATION (PPM)
16 PUMPING TEMPERATURE : °F 60
17 FLOW : gpm 4900
18 DISCHARGE PRESSURE : (6.3.2) psia
19 SUCTION PRESSURE : psia 15.5
20 DIFFERENTIAL PRESSURE : psi
21 DIFFERENTIAL HEAD : ft 370
22 NPSHA : ft 17
23 HYDRAULIC POWER : HP 268.00
24 SITE AND UTILITY DATA
25 LOCATION: COOLING WATER :
26 OUTDOOR UNHEATED INLET RETURN DESIGN
27 MOUNTED AT : GRADE TROPICALISATION REQD TEMP °F MAX
28 ELECTRIC AREA CLASSIFICATION: 6.1.22DIVISION 2 PRESS. psig MIN
29 GROUP Class I / Group C Class I / Group D TEMP CLASS T3 SOURCE
30 SITE DATA : COOLING WATER CHLORIDE CONCENTRATION: ppm
31 ELEVATION (MSL) : 3300 ft BAROMETER : 26.811 in Hg INSTRUMENT AIR : MAX psig MIN psig
32 RANGE OF AMBIENT TEMPS:MIN / MAX 0 / 104 °F STEAM
33 RELATIVE HUMIDITY: MIN / MAX 0 / 100 % DRIVERS HEATING
34 UNUSUAL CONDITIONS: TEMP °F Max
35 Min
36 UTILITY CONDITIONS : PRESS. psig Max
37 ELECTRICITY : DRIVERS HEATING CONTROL SHUTDOWN Min
38 VOLTAGE 2300
39 PHASE 3
40 HERTZ 60
41 PERFORMANCE DRIVER (7.1.5)
42 PROPOSAL CURVE NO. 8 LPN 21-E-P001 RPM 1750 Driver Type MOTOR
43 As Tested Curve No. GEAR NO
44 IMPELLER DIA.: RATED 20.02 MAX. 21.3 MIN. 16.97 in. VARIABLE SPEED REQUIRED NO
45 RATED POWER 334 HP EFFICIENCY 80.2 (%) SOURCE OF VARIABLE SPEED Other
46 RATED CURVE BEP FLOW (at rated impeller dia) 4900 gpm OTHER
47 MIN FLOW : THERMAL gpm STABLE gpm MANUFACTURER Siemens
48 PREFERRED OPERATING REGION (6.1.11) 3430 to 5880 gpm NAMEPLATE POWER 400 HP
49 ALLOWABLE OPERATING REGION 1879.85 to 6860 gpm Nominal RPM
50 MAX HEAD @ RATED IMPELLER 435.96 ft RATED LOAD RPM 1786
51 MAX POWER @ RATED IMPELLER (6.8.9) 397 HP FRAME OR MODEL 5011
52 NPSH3 AT RATED FLOW : 12.70 ft ORIENTATION HORIZONTAL
53 CL PUMP TO U/S BASEPLATE 3.33 ft LUBE OIL
54 NPSH MARGIN AT RATED FLOW : 4.30 ft BEARING TYPE: SLEEVE
55 SPECIFIC SPEED (6.1.9) gpm,rpm,ft 1345 RADIAL /
56 SUCTION SPECIFIC SPEED LIMIT 10670 THRUST /
57 SUCTION SPECIFIC SPEED gpm,rpm,ft STARTING METHOD
58 MAX. ALLOW. SOUND PRESS. LEVEL REQD (6.1.14) 85 (dBA) SEE DRIVER DATA SHEET
59 EST MAX SOUND PRESS. LEVEL (dBA)
60 MAX. SOUND POWER LEVEL REQ'D (6.1.14)
61 EST MAX SOUND POWER LEVEL
DATA SHEET No. Gasoline Replacement Pump Rev: 0 SHEET 2 of 7
CENTRIFUGAL PUMP DATA SHEET
1 Note CONSTRUCTION Rev
2 API PUMP TYPE: BB1 [Based on API 610 definitions] CASING MOUNTING: CENTERLINE
3 CASING TYPE: (6.3.10) MULTIPLE VOLUTE
4 NOZZLE CONNECTIONS: (6.5.5) OH3 BACKPULLOUT LIFTING DEVICE REQD. (9.1.2.6)
5 Size Facing Rating Position CASE PRESSURE RATING:
6 SUCTION 14" RF 300 SIDE MAWP : (6.3.6) 290.1 psig @ 60.0 °F
7 DISCHARGE 8" RF 300 SIDE HYDROTEST : psig @ amb °F
8 PRESSURE CASING AUX. CONNECTIONS: (6.4.3.2)
9 No. Size Type Facing Rating Posn. HYDROTEST OH PUMP AS ASSEMBLY
10 BALANCE/LEAK OFF SUCT'N PRESS. REGIONS DESIGNED FOR MAWP
11 DRAIN 1 0.75" SWF RF 300 ROTATION: (VIEWED FROM COUPLING END) CCW
12 VENT 1 0.75" SWF RF 300 • IMPELLERS INDIVIDUALLY SECURED :
13 PRESSURE GAGE • BOLT OH 3/4/5 PUMP TO PAD / FOUNDATION :
14 TEMP GAGE • PROVIDE SOLEPLATE FOR OH 3/4/5 PUMPS
15 WARM-UP LINE ROTOR:
16 SHAFT FLEXIBILITY INDEX (SFI) (9.1.1.3)
17 Drain Valve Supplied By SUPPLIER First Critical Speed Wet (Multi stage pumps only)
18 DRAINS MANIFOLDED YES COMPONENT BALANCE TO ISO 1940 G1.0 YES
19 VENT Valve Supplied By SUPPLIER SHRINK FIT -LIMITED MOVEMENT IMPELLERS (9.2.2.3)
20 VENTS MANIFOLDED YES
21 THREADED CONS FOR PIPELINE SERVICE & < 50°C (6.4.3.2) NO COUPLING:(7.2.3) (7.2.13.f)
22 SPECIAL FITTINGS FOR TRANSITIONING (6.4.3.3) NO MANUFACTURER REXNORD
23 CYLINDRICAL THREADS REQUIRED (6.4.3.8) MODEL
24 GUSSET SUPPORT REQUIRED YES RATING (POWER/100 RPM)
25 MACHINED AND STUDDED CONNECTIONS (6.4.3.12) NO SPACER LENGTH 10 in.
26 VS 6 DRAIN N/A SERVICE FACTOR 1.5
27 DRAIN TO SKID EDGE YES RIGID NO
28 COUPLING WITH HYDRAULIC FIT (7.2.10) NO
29 MATERIAL (6.12.1.1) COUPLING BALANCED TO ISO 1940-1 G6.3 (7.2.3)
30 APPENDIX H CLASS S-6 COUPLING WITH PROPRIETARY CLAMPING DEVICE (7.2.11)
31 MIN DESIGN METAL TEMP (6.12.4.1) °F YES
32 REDUCED-HARDNESS MATERIALS REQ'D (6.12.1.12.1) NO COUPLING IN COMPLIANCE WITH (7.2.4) API 610 compliant
33 Applicable Hardness Standard (6.12.1.12.3) NA COUPLING GUARD STANDARD PER (7.2.13.a)
34 BARREL : Window on Coupling Guard
35 CASE : A216 GR. WCB
36 DIFFUSERS BASEPLATE
37 IMPELLER : A487 CA6NM API BASEPLATE NUMBER :
38 IMPELLER WEAR RING : A426 CPCA15 250-300 BHN BASEPLATE CONSTRUCTION (7.3.14) FULL TOP DECKING
39 CASE WEAR RING : A426 CPCA15 350-400 BHN BASEPLATE DRAINAGE (7.3.1) Entire Baseplate Drain Rim
40 SHAFT: A434 4140 Gr.BC MOUNTING : GROUTED
41 Bowl (if VS-type) NON-GROUT CONSTRUCTION : (7.3.13) NOT REQUIRED
42 Inspection Class Level 1 VERTICAL LEVELING SCREWS : REQUIRED
43 BEARINGS AND LUBRICATION (6.10.1.1) LONGITUDINAL DRIVER POSITIONING SCREWS : REQUIRED
44 BEARING (TYPE / NUMBER): (6.11.4) SUPPLIED WITH : GROUT AND VENT HOLES YES
45 RADIAL BALL / 2315 DRAIN CONNECTION YES
46 THRUST BALL / 7315 MOUNTING PADS SIZED FOR BASEPLATE LEVELING (7.3.5)
47 REVIEW AND APPROVE THRUST BEARING SIZE : (9.2.5.2.4) MOUNTING PADS TO BE MACHINED (7.3.6) YES
48 PROVIDE SPACER PLATE UNDER ALL EQUIPMENT FEET
49 LUBRICATION : (6.10.2.2) (6.11.3) (9.6.1) FLOOD OTHER
50 PRESSURE LUBE SYSTEM TO ISO 10438- (9.2.6.5)
50 P-4849 ISO 10438 DATA SHEETS ATTACHED
51 Pressurized Lube Oil System mtd on pump baseplate REMARKS :
52 Location of Pressurized Lube Oil System mounted on baseplate :
53
54 INTERCONNECTING PIPING PROVIDED BY
55
56 OIL VISC. ISO GRADE VG 46
57 CONSTANT LEVEL OILER : REQUIRED
DATA SHEET No. Gasoline Replacement Pump Rev: ´0 SHEET 3 of 7
CENTRIFUGAL PUMP DATA SHEET
1 Note INSTRUMENTATION SEAL SUPPORT SYSTEM MOUNTING Rev
2 SEE ATTACHED API-670 DATA SHEET NO SEAL SUPPORT SYSTEM MOUNTED ON PUMP BASEPLATE
3 ACCELEROMETER (7.4.2.1) (7.5.1.4) YES
4 Number of Accelerometers 2 IDENTIFY LOCATION ON BASEPLATE
5 Mounting Location of Accelerometers
6 INTERCONNECTING PIPING BY Supplier
7 PROVISION FOR MTG ONLY (6.10.2.10)
8 Number of Accelerometers MECHANICAL SEAL (6.8.1)
9 Mounting Location of Accelerometers SEE ATTACHED ISO 21049/API 682 DATA SHEET NO
10 ADDITIONAL CENTRAL FLUSH PORT (6.8.9)
11 FLAT SURFACE REQUIRED (6.10.2.11) YES HEATING JACKET REQ'D. (6.8.11)
12 Number of Accelerometers 2
13 Mounting Location of Accelerometers
SSU 32.5 HEATING AND COOLING (6.1.17)
14 COOLING REQ'D NO
15 VIBRATION PROBES (7.4.2.2) COOLING WATER PIPING PLAN
16 PROVISIONS FOR VIB. PROBES NO COOLING WATER PIPING
17 NUMBER PER RADIAL BEARING P-4849 FITTINGS
18 NUMBER PER AXIAL BEARING COOLING WATER PIPING MATERIALS
COOLING WATER REQUIREMENTS:
19 MONITORS AND CABLES SUPPLIED BY (7.4.2.4) BEARING HOUSING gpm
20 HEAT EXCHANGER gpm
21 TEMPERATURE (7.4.2.3) TOTAL COOLING WATER gpm
22 PROVISIONS FOR TEMP PROBES YES HEATING MEDIUM
23 RADIAL BEARING TEMP. YES OTHER
24 NUMBER PER RADIAL BEARING 1 HEATING PIPING
25 THRUST BEARING TEMP. YES
26 NUMBER PER THRUST BEARING ACTIVE SIDE 1 PIPING & APPURTENANCES
27 NUMBER PER THRUST BEARING INACTIVE SIDE MANIFOLD PIPING FOR PURCHASER CONNECTION (7.5.1.6)
28 TEMP. GAUGES (WITH THERMOWELLS) (9.1.3.6) YES VENT YES
29 PRESSURE GAUGE TYPE DRAIN YES
30 Remarks COOLING WATER
31 TAG ALL ORIFICES (7.5.2.4) YES
32 SOCKET WELD CONN ON SEAL GLAND (7.5.2.8) NO
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
DATA SHEET No. Gasoline Replacement Pump Rev: ´0 SHEET 4 of 7
CENTRIFUGAL PUMP DATA SHEET
1 Note SURFACE PREPARATION AND PAINT TEST Rev
2 MANUFACTURER'S STANDARD YES SHOP INSPECTION (8.1.1)
3 OTHER (SEE BELOW) NO PERFORMANCE CURVE
4 SPECIFICATION NO. PER SUPPLIER STANDARD & DATA APPROVAL PRIOR TO SHIPMENT. NO
5 TEST WITH SUBSTITUTE SEAL (8.3.3.2.b) YES
6 PUMP: MATERIAL CERTIFICATION REQUIRED CASING YES
7 PUMP SURFACE PREPARATION SP-6 (6.12.1.8) IMPELLER YES
8 PRIMER SHAFT YES
9 FINISH COAT OTHER NO
10 CASTING REPAIR WELD PROCEDURE APPR REQD NO
BASEPLATE: (6.12.2.5) (6.12.3.1)
11 BASEPLATE SURFACE PREPARATION INSPECTION REQUIRED FOR CONNECTION WELDS (6.12.3.4.d)
12 PRIMER: (6.12.3.4.e) MAG PARTICLE
13 FINISH COAT RADIOGRAPHY
14 DETAILS OF LIFTING DEVICES LIQUID PENETRANT
15 ULTRASONIC
16 SHIPMENT: (8.4.1) INSPECTION REQUIRED FOR CASTINGS
17 EXPORT BOXING REQUIRED NO MAG PARTICLE
18 OUTDOOR STORAGE MORE THAN 6 MONTHS NO RADIOGRAPHY
LIQUID PENETRANT
19 SPARE ROTOR ASSEMBLY PACKAGED FOR: ULTRASONIC
20 ROTOR STORAGE ORIENTATION (9.2.8.2) HORIZONTAL HARDNESS TEST REQUIRED (8.2.2.7)
21 SHIPPING & STORAGE CONTAINER FOR VERT STORAGE (9.2.8.3) ADDNL SUBSURFACE EXAMINATION (6.12.1.5) (8.2.1.3)
22 FOR
23 N2 PURGE (9.2.8.4) METHOD
24 SPARE PARTS PMI TESTING REQUIRED (8.2.2.8)
25 START-UP NO COMPONENTS TO BE TESTED
26 NORMAL MAINTENANCE NO
27 WEIGHTS lb RESIDUAL UNBALANCE TEST (J.4.1.2)
28 ITEM No PUMP DRIVER GEAR BASE TOTAL NOTIFICATION OF SUCCESSFUL SHOP
29 P-4849 TBD TBD TBD TBD PERFORMANCE TEST (8.1.1.c) (8.3.3.5)
30 BASEPLATE TEST (7.3.21)
31 HYDROSTATIC NON-WIT
32 HYDROSTATIC TEST OF BOWLS & COLUMN (9.3.13.2)
33 OTHER PURCHASER REQUIREMENTS PERFORMANCE TEST NON-WIT
34 COORDINATION MEETING REQUIRED (10.1.3) YES TEST IN COMPLIANCE WITH (8.3.3.2)
35 MAXIMUM DISCHARGE PRESSURE TO INCLUDE TEST DATA POINTS TO (8.3.3.3)
36 MAX RELATIVE DENSITY TEST TOLERANCES TO (8.3.3.4)
37 OPERATION TO TRIP SPEED NPSH (8.3.4.3.1) (8.3.4.3.4) NON-WIT
38 MAX DIA. IMPELLERS AND/OR NO OF STAGES NO NPSH-1ST STG ONLY (8.3.4.3.2)
39 CONNECTION DESIGN APPROVAL (9.2.1.4) NPSH TESTING TO HI 1.6 OR ISO 9906 (8.3.4.3.3)
40 TORSIONAL ANALYSIS / REPORT (6.9.2.10) NO TEST NPSHA LIMITED TO 110% SITE NPSHA (8.3.3.6)
41 PROGRESS REPORTS NO RETEST ON SEAL LEAKAGE (8.3.3.2.d)
42 OUTLINE OF PROC FOR OPTIONAL TESTS (10.2.5) RETEST REQUIRED AFTER FINAL HEAD ADJ (8.3.3.7.b)
43 ADDITIONNAL DATA REQUIRING 20 YEARS RETENTION (8.2.1.1) COMPLETE UNIT TEST (8.3.4.4.1)
44 SOUND LEVEL TEST (8.3.4.5)
45 LATERAL ANALYSIS REQUIRED (9.1.3.4) (9.2.4.1.3) NO CLEANLINESS PRIOR TO FINAL ASSEMBLY (8.2.2.6)
46 MODAL ANALYSIS REQUIRED (9.3.9.2) NO LOCATION OF CLEANLINESS INSPECTION
47 DYNAMIC BALANCE ROTOR (6.9.4.4) NO NOZZLE LOAD TEST
48 INSTALLATION LIST IN PROPOSAL (10.2.3.l) NO CHECK FOR CO-PLANAR MOUNTING PAD SURFACES
49 P-4849
VFD STEADY STATE DAMPED RESPONSE ANALYSIS (6.9.2.3) MECHANICAL RUN TEST UNTIL OIL TEMP STABLE
50 4 HR. MECH RUN AFTER OIL TEMP STABLE (8.3.4.2.1)
51 TRANSIENT TORSIONAL RESPONSE (6.9.2.4) 4 HR. MECH RUN TEST (8.3.4.2.2)
52 BEARING LIFE CALCULATIONS REQUIRED (6.10.1.6)
IGNITION HAZARD ASSMT TO EN 13463-1 (7.2.13.e) BRG HSG RESONANCE TEST (8.3.4.7)
53 CASING RETIREMENT THICKNESS DRAWING (10.3.2.3) STRUCTURAL RESONANCE TEST (9.3.9.2)
54 FLANGES RQD IN PLACE OF SKT WELD UNIONS (7.5.2.8) REMOVE / INSPECT HYDRODYNAMIC BEARINGS AFTER TEST
55 INCLUDE PLOTTED VIBRATION SPECTRA (6.9.3.3) NO (9.2.7.5)
56 CONNECTION BOLTING (7.5.1.7) SS AUXILIARY EQUIPMENT TEST (8.3.4.6)
57 CADMIUM PLATED BOLTS PROHIBITED EQUIPMENT TO BE INCLUDED IN AUXILLIARY TESTS
58 VENDOR TO KEEP REPAIR AND HT RCDS (8.2.1.1.c)
59 VENDOR SUBMIT TEST PROCEDURES (8.3.1.1) LOCATION OF AUXILIARY EQUIPENT TEST
60 SUBMIT INSPECTION CHECK LIST (8.1.5)
61 IMPACT TEST (6.12.4.3) PER EN 13445
62 PER ASME SECTION VIII
REMOVE CASING AFTER TEST
DATA SHEET No. Gasoline Replacement Pump Rev: ´0 SHEET 5 of 7
VERTICAL PUMP SUPPLEMENTAL DATA SHEET
1 Note VERTICAL TYPE (FIG 1.1) Rev
2 REMARKS
3
4
5
6 VERTICAL PUMPS VERTICAL PUMPS (CONT'D)
7 PUMP THRUST: (+) UP (-) DOWN LINE SHAFT:
8 STATIC THRUST lbf lbf LINE SHAFT DIAMETER in.
9 AT MIN FLOW lbf lbf TUBE DIAMETER in.
10 AT RATED FLOW lbf lbf LINE SHAFT COUPLING:
11 AT MAX FLOW lbf lbf LINESHAFT CONNECTION
12 MAX THRUST lbf lbf
13 SOLEPLATE REQUIRED • SUCTION STRAINER TYPE
14 SOLEPLATE Length x Width ft X ft • LEVEL CONTROL
15 SOLEPLATE THICKNESS in. IMPELLER COLLETS ACCEPTABLE
16 MOUNTING FLANGE REQUIRED HARDENED SLEEVES UNDER BEARINGS (9.3.10.5)
17 COLUMN PIPE: RESONANCE TEST
18 DIAMETER in. STRUCTURAL ANALYSIS (9.3.5)
19 LENGTH ft
20 NUMBER DRIVER ALIGNMENT SCREWS
21 SPACING ft SUCTION CAN
22 GUIDE BUSHINGS: SUCTION CAN THICKNESS in.
23 NUMBER LENGTH ft
24 LINE SHAFT BEARING SPACING in. DIAMETER in.
25 GUIDE BUSHING LUBE: SEPARTATE MOUNTING PLATE (9.3.8.3.1)
26 PROVIDE SEPARATE SOLEPLATE (9.3.8.3.3)
27 DRAIN PIPED TO SURFACE (9.3.13.5)
28 BOWL HEAD CALCULATION REQUIRED
29 MATERIALS (additional)
30 SUCTION CAN / BARREL: LINESHAFT SLEEVES :
31 DISCHARGE HEAD : • BEARING RETAINER :
32 BOWL SHAFT : SHAFT ENCLOSING TUBE :
33 LINESHAFT : DISCHARGE COLUMN :
34 LINESHAFT HARDFACING : PRESSURE RATING: MAWP HYDRO
35 BELLMOUTH : HEAD
36 BOWL BEARING : COLUMN PIPE
37 LINESHAFT BEARING : BOWL
38 SUMP ARRANGEMENT
39 SUMP DIMENSIONS :
40 GRADE ELEVATION 1 ft
41 LOW LIQUID LEVEL 2 ft 1 2 3
42 C.L. OF DISCHARGE 3 ft
43 SUMP DEPTH l1 ft
l3
44 PUMP LENGTH l2 ft
45 GRADE TO DISCH. l3 ft
46 GRADE TO LOW LIQUID LVL l4 ft
l4
47 GRADE TO 1ST STG IMPL'R. l5 ft
l5
l2
48 SUBMERGENCE REQ'D l6 ft
l1
49 SUMP DIAMETER d ft
l6
50
51
52
53 d
54
55
56
57
DATA SHEET No. Gasoline Replacement Pump Rev: ´0 SHEET 6 of 7
CENTRIFUGAL PUMP DATA SHEET
1 Note PRESSURE VESSEL DESIGN CODE REFERENCES Rev
2 THESE REFERENCES MUST BE LISTED BY THE MANUFACTURER
3 CASTING FACTORS USED IN DESIGN ( TABLE 4)
4 SOURCE OF MATERIAL PROPERTIES
5
6 WELDING AND REPAIRS
7 THESE REFERENCES MUST BE LISTED BY THE PURCHASER. (DEFAULT TO TABLE 11 IF NO PURCHASER PREFERENCE IS STATED)
8 ALTERNATE WELDING CODES AND STANDARDS NO
9 WELDING REQUIREMENT (APPLICABLE CODE OR STANDARD) DEFAULT PER TABLE 10
10 WELDER/OPERATOR QUALIFICATION
11 WELDING PROCEDURE QUALIFICATION EXXON CORPORATION
12 NON-PRESSURE RETAINING STRUCTURAL WELDING SUCH AS BASEPLATES OR SUPPORTS
13 MAGNETIC PARTICLE OR LIQUID
SSU PENETRANT EXAMINATION OF PLATE EDGES
14 POSTWELD HEAT TREATMENT
15 POSTWELD HEAT TREATMENT OF CASING FABRICATION WELDS
16
17 MATERIAL INSPECTION
18 THESE REFERENCES MUST BE LISTED BY THE PURCHASER DEFAULT TO TABLE 14 NO
ALTERNATIVE MATERIAL INSPECTIONS AND ACCEPTANCE CRITERIA (SEE TABLE 14) (8.2.2.5)
19 TYPE OF INSPECTION METHOD FOR FABRICATIONS FOR CASTINGS
20 RADIOGRAPHY
21 ULTRASONIC INSPECTION
22 MAGNETIC PARTICLE INSPECTION
23 LIQUID PENETRANT INSPECTION
24 VISUAL INSPECTION (all surfaces)
25
26 REMARKS :
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
DATA SHEET No. Gasoline Replacement Pump Rev: ´0 SHEET 6 of 7
NOTES
1 Note Rev
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
Gasoline Replacement Pump Rev: ´0 SHEET 7 of 7