0% found this document useful (0 votes)
68 views4 pages

BT Micropac en

The document describes a Programmable Automation Controller called sigma microPAC. It has a basic unit with digital and analog inputs and outputs that can be expanded with additional modules. It uses common programming languages and is suitable for controlling machines and small processes.

Uploaded by

Carlos
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
68 views4 pages

BT Micropac en

The document describes a Programmable Automation Controller called sigma microPAC. It has a basic unit with digital and analog inputs and outputs that can be expanded with additional modules. It uses common programming languages and is suitable for controlling machines and small processes.

Uploaded by

Carlos
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

BT-microPAC-eng:Broch Sigmapac ENG.qxp 21/05/2009 15.

10 Pagina 2

BT.04.01 S2/E

sigma microPAC®
Programmable Automation Controller
Compact, with on-board I/O
and expansion capability
sigma microPAC is a micro
Programmable Automation
Controller ideal for applications
where process variables such as
temperature, pressure, flow, level,
etc. have an essential role.
sigma microPAC adds powerful and
accurate process control with easy
and quick management of logic and
sequence control typical of PLCs.
The sigma microPAC consists of a
CPU with 8 digital inputs, 8 digital
outputs, up to 8 analogue inputs and
up to 4 analogue outputs. Up to two
expansion modules can be added to
the basic unit for up to 40 digital
inputs and 40 digital outputs.
Programming is compliant with
IEC/EN 611131-3 standards.
Six international programming
languages are available with a large
library of Ascon function blocks
dedicated to process and
logic/sequence control.
sigma microPAC is ideal for complete
machine control and small processes
such as climatic chambers, kilns,
autoclaves, boilers, etc....

ISO 9001 Certified


BT-microPAC-eng:Broch Sigmapac ENG.qxp 21/05/2009 15.10 Pagina 3

Technical data

Hardware Resources High level Analogue inputs


Basic Unit 6 configurable, scalable (std.) 0...10V, 0/1...5V, 0...1V - 0/4...20mA
Power supply 2 configurable, scalable (option) ±10V, ±5V, ±1V - 0/4...20mA
(24Vdc, 10.... 15W) Acquisition time standard inputs: 170 ms, optional inputs: 40 ms,
Resolution 16 bit
8 DI 24Vdc 8 DO, 24Vdc, 0.5A Accuracy 0.1% of span
Input impedance >100 kΩ (V); 300 Ω (mA)
6 AI, High level 2/4 AO, mA, V
Isolation 800 V between Power supply and logics

Logic Ethernet Universal Analogue inputs


2 AI Universal Modbus TCP ±50 mV, ±100 mV, ±300 mV,
or
RS232 / 485 + RS485
±1.25 V high impedance,
2 AI High Level 2 configurable, scalable (option) TC (J, K, L, N, R, S, T),
Modbus RTU
Master / Slave Pt100 (3 wire), Pt1000 and
potentiometer (0.1... 10kΩ)
1st Expansion Module Acquisition time 60 ms
8/16 DI 24Vdc 8/16 DO, 24Vdc, 0.5A Resolution 16 bit
or or Accuracy 0.1% of span
8 DI, 120 Vac 8 DO (relay: 2A, NA) Input inpedance 10 MΩ (V)
Cold junction compensation ≤1°C/20°C ambient temperature
2nd Expansion Module 800 V between Power supply and logics
8/16 DI 24Vdc 8/16 DO, 24Vdc, 0.5A Isolation 40 Vpp between the 2 channels
or or (differential inputs)
8 DI, 120 Vac 8 DO (relay: 2A, NA)
Analogue outputs
Notes: - The channels represented with are optional resources 2/4 configurable (option) ±10 V (±25 mA max.), 0/4... 20 mA
- One or two expansion modules can be fitted to the basic unit Update time 35 ms
with direct connection to the CPU. Resolution 13 bit
Additional expansion can be obtained by connecting, via the Accuracy 0.1% of span
RS485 port, external digital and analog sigma I/O Modbus Isolation 800 V between Power supply and logics
modules.
Digital inputs
CPU specifications
8, up to 40 (with the expansions) 24 Vdc (ON: 5...30V, OFF: 0...3V) or
Processor 32 bit ARM 8 + 8/16 max. (with the expansions) 8 at 24 Vdc + 8/16 max. at 120 Vac
Program memory 2 MB Flash Max. input frequency 80 Hz
Dynamic memory 16 MB RAM Type Sink
Retentive memory 64 kB redundant Protection Reverse polarity and overvoltage
Memory data retention 10 years (with replaceable battery) Isolation 800 V between Power supply and logics
Real Time Clock standard Status indicator 1 LED • (yellow) /channel
Timer resolution 1 ms maximum Compliance IEC/EN 61131-2 (type 2)
Computing speed 70 Mips Digital outputs
Minimum cycle time ≥5ms (typical 10ms)
8, up to 40 (with the expansions) 24Vdc, 0.5 A or
Acquisition time of inputs +
Minimum response time Type Source (PNP)
execution time of cycles
Protection Overvoltage and short circuit
Ethernet 10 Mb base T (programming,
Communications port (std.) Isolation 800V between Power supply and logics
configuration) Modbus TCP (supervision) 8 + 8/16 max. (with the expansions) 8 at 24 Vdc + 8/16 relays (2A, 240 Vac, NA)
Communications port
1RS485 Modbus RTU (Master/Slave) Status indicator 1 red LED • (red) /channel
1RS232/485 Modbus RTU (Master/Slave) for
(option; only 1 Modbus
Supervision, expansion Modbus I/Os or Modules 66
Master can be used)
generic ASCII for Modem connection
Front LED indications
for digital I/O, communications ports and 64 70
CPU diagnostic A B 110
46 40
General and environmental specifications
Power supply voltage 24 Vdc (-15...+25%) 152 76 45 21
Power consumption 10 W (+5 W with both the expansions)
Reverse polarity protection Standard 35 x 7.5 DIN rail
Isolation class II (50 Vrms), EN61010-1 DIN 46277-3
Vibration resistance 10...57Hz, 0.0375mm, 57...150Hz, 0.5g (3 axis)
Shock resistance 15g A - Basic unit (weight 460g)
Operating temperature 0…55°C; (humidity: 5... 95%) - Expansion module with 16 DI + 16 DO (weight: 400g)
Storage temperature -40…70°C B Expansion module with 8 DI + 8 DO (weight: 220 g)
CE compliance EN 61131-2 Terminal blocks(option) 22
Approvals CE, UL and cUL
Protection IP20 48
Dimensions / weight See drawing
2
BT-microPAC-eng:Broch Sigmapac ENG.qxp 21/05/2009 15.10 Pagina 4

Configuration diagram

Operator SCADA Station Remote Modbus I/Os


Panel

Remote Control
Ethernet RS485 (GSM modem)
10 base T Modbus RTU
Master
RS232 ASCII

sigma microPAC sigma microPAC sigma microPAC


Basic Unit Expansion module Expansion module
CPU + 28 I/O 32 digital I/O 16 digital I/O

Programming Advanced functions Expansion of HW resources


sigma microPAC offers the maximum flexibility Ascon libraries include a large number of The I/O resources of sigma microPAC can
the design of control strategies. function blocks, macroblocks, on-line be expanded by using dedicated expansion
● Environment: OpenPCS (Ascon Edition) multi- documentation, functional examples in a modules described in this bulletin, and/or any
tasking, standard IEC 61131-3 (EN 61131-3). complete IEC 61131 environment; allowing the other remote analogue or digital I/O with
● 6 programming languages: user to quickly customize their application. Modbus RTU protocol.
IL - Istruction List. The Ascon libraries include the following The remote I/O with Modbus RTU protocol
ST - Structured Text. function blocks: offered by Ascon are:
LD - Ladder Diagram. - Advanced P.I.D. single action and heat/cool - IO-MB/AI-08HL (8 AI, 0...10 V, 0/4...20 mA).
FBD - Function Block Diagram. with overshoot control. - IO-MB/AI-08TC (8 AI for TC and mV).
SFC - Sequential Function Chart. - Cascade, Ratio, and Override control. - IO-MB/AI-04RT (4 AI, for TCand mVR).
CFC - Continuous Function Chart. - Complete controller block ready to use. - IO-MB/AO-08HL (8 AO, 0...10 V, 0/4...20 mA).
● Diagnostics / Debug: integrated on-line.
- Auto-tuning. - IO-MB/DI-16LV (16 DI, 24 Vdc).
- Auto/Manual station with bumpless control. - IO-MB/DO-16TS (16 DO, 24 Vdc, 0.5 A).
- Programming of cycles, process - IO-MB/DM-08TS (8 channel modules;
sequences and production recipes. each channel can be configured as
Function blocks for GSM/GPRS modems are DI 24 Vdc or DO 24 Vdc, 0.5 A).
available for remote control.
Integration with Operator Panels / PCs /
and SCADA Systems
Integration is managed by the Ethernet
connection with Modbus TCP protocol
and/or with the RS232/485 connection over
Modbus RTU protocol.
Ascon offers a wide range of TFT touch screen
colour operator panels from 4.3” to 12.1”.

3
BT-microPAC-eng:Broch Sigmapac ENG.qxp 21/05/2009 15.10 Pagina 1

Ordering codes

Basic Unit (CPU with integrated I/O)


Line Version Hardware
ASCON spa
Model: MP - 01 / A B C D E F G Via Falzarego, 9/11
• • • • • • • 20021 Baranzate
Analogue inputs (Milano) Italy
Analogue outputs Tel. +39 02 333 371
8 DI 24Vdc + 8 DO 24Vdc 0.5A Fax +39 02 350 4243
Serial communications Modbus RTU www.ascon.it
Ethernet port Modbus TCP [email protected]
Connector types
Installation manual ASCON FRANCE
BP 76
77202 Marne Vallée -
Analogue inputs A Serial communications D Cedex 01
6 analogue inputs - High level (mA, V) 0 Not fitted 0 Tél. +33 (0) 1 64 30 62 62
6 analogue inputs - High level (mA, V) RS232/485 + RS485 Modbus RTU 1 Fax +33 (0) 1 64 30 84 98
1 www.ascon.fr
+ 2 analogue inputs - (mA, V bipolar)
[email protected]
6 analogue inputs - High level (mA, V) Other communications port E
2 AGENCE SUD-EST
+ 2 universal inputs (TC, RTD, mV, pot.) Ethernet port Modbus TCP 0
Tél. +33 (0) 4 74 27 82 81
Fax +33 (0) 4 74 27 81 71
Analogue outputs B Type of connector F
None 0 Terminal blocks, screw terminals V ASCON
2 analogue outputs - 0/4... 20 mA, ±10V 1 Terminal blocks, spring terminals M CORPORATION
4 analogue outputs - 0/4... 20 mA, ±10V 2 1884 East Fabyan Parkway
Batavia, Illinois 60510
Digital I/O C Installation manual G Tel. +1 630 482 2950
8 DI 24Vdc + 8 DO 24Vdc 0.5A 0 English (std.) 0 Fax +1 630 482 2956
www.asconcorp.com
[email protected]
WORLDWIDE NETWORK OF
DIRECT SALES CENTERS,
DISTRIBUTORS AND SYSTEM
INTEGRATORS
Europe
I/O Expansion modules Belgium, Croatia, Czech Rep.,
MP-D1/08-08/M0 Digital expansion module with 8 Inputs (24 Vdc) and 8 Outputs (24 Vdc, 0.5 A), Denmark, Esthonia, Finland, France,
terminal blocks with spring terminals and manuals in English language Germany, Great Britain, Greece,
Holland, Ireland, Norway, Poland,
MP-D2/08-08/M0 Digital expansion module with 8 Inputs (24 Vdc) and 8 Relay Outputs (2A, NO), Portugal, Romania, Russia, Slovakia,
terminal blocks with spring terminals and manuals in English language Slovenia, Spain, Sweden,
Switzerland, Turkey, Ukraine
MP-D4/08-08/M0 Digital expansion module with 8 Inputs (120 Vac) and 8 Relay Outputs (2A, NO),
terminal blocks with spring terminals and manuals in English language
Americas
Argentina, Brazil, Canada, Chile,
MP-D1/16-16/M0 Digital expansion module with 16 Inputs (24 Vdc) and 16 Outputs (24 Vdc, 0.5 A), Colombia, Ecuador, Paraguay,
terminal blocks with spring terminals and manuals in English language Peru, Urugay, Venezuela
Other locations
Note: /M0 terminal blocks with spring terminals;
Algeria, Australia, China, Egypt,
/V0 terminal blocks with screw terminals. Hong Kong, India, Indonesia, Iran,
Israel, Malaysia, Marocco, New
Zeland, Pakistan, Saudi Arabia,
Singapore, Taiwan, Thailand,
Tunisia, South Africa & South East
Africa, UAE

You might also like