0% found this document useful (0 votes)
41 views19 pages

(INR18650-20S) Cell - (Tentative)

This document provides specifications for a lithium-ion rechargeable cell model INR18650-20S. It outlines nominal specifications including capacity, voltage, charge/discharge rates and temperature performance. It also describes mechanical, electrical and storage characteristics, and safety requirements for the cell.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
41 views19 pages

(INR18650-20S) Cell - (Tentative)

This document provides specifications for a lithium-ion rechargeable cell model INR18650-20S. It outlines nominal specifications including capacity, voltage, charge/discharge rates and temperature performance. It also describes mechanical, electrical and storage characteristics, and safety requirements for the cell.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 19

-SAMSUNG SDI Confidential Proprietary –

Spec. No. INR18650-20S Version No. 1.0

Specification of Product
1. Customer :

2. Product : Lithium-ion Rechargeable Cell

3. SDI Model : INR18650-20S

4. Approved by

Division

Signature

Date / / / / / /

5. Date of Application (YY/MM/DD) :

6. Supplier : SAMSUNG SDI Co., Ltd.


Cell Business Division

Issued Checked Approved


-SAMSUNG SDI Confidential Proprietary –

Spec. No. INR18650-20S Version No. 1.0

Revision history

Revision Changes
Date(‘yr-m-d) Page Item Description
No. / Author
v1.0 ‘14-11-27 First Edition In-Young Jang

- 1/18 -
-SAMSUNG SDI Confidential Proprietary –

Spec. No. INR18650-20S Version No. 1.0

1.0. Scope

This product specification has been prepared to specify the rechargeable lithium-ion cell
('cell') to be supplied to the customer by Samsung SDI Co., Ltd.

2.0. Description and model name

2.1 Description lithium-ion rechargeable cell


2.2 Model name INR18650-20S

3.0. Nominal specifications


Item Specification
Min. 2,000mAh
- Charge: 0.5C (1.0A), 4.20V, 0.05C(100mA) cut-off
3.1 Standard discharge capacity
- Discharge: 0.2C (400mA), 2.5V cut-off
* 1C = 2000mA
Min. 1,950mAh
3.2 Rated discharge capacity - Charge: 4A, 4.20V, CCCV 100mA cut-off
- Discharge: 10A , 2.5V cut-off
3.2 Nominal voltage 3.6V
3.3 Standard charge CCCV, 1.0A, 4.2V, 100mA cut-off
3.4 Rated charge CCCV, 4A, 4.2V, 100mA cut-off
Standard charge : 160min / 100mA cut-off
3.5 Charging time
Rapid charge: 60min (at 25℃) / 100mA cut-off
3.6 Max. continuous discharge
30A(at 25℃), 60% at 250 cycle
(Continuous)
3.7 Discharge cut-off voltage
2.5V
End of discharge
3.8 Cell weight 48.0g max
Height : Max. 65.00 mm
3.9 Cell dimension
Diameter : Max. 18.43 mm
Charge : 0 to 50℃
3.10 Operating temperature (recommended recharge release < 45℃)
(surface temperature) Discharge: -20 to 80℃
(recommended re-discharge release < 60℃)
1.5 year -30~25℃(1*)
3.11 Storage temperature
3 months -30~45℃(1*)
(Recovery 90% after storage)
1 month -30~60℃(1*)
Note (1): If the cell is kept as ex-factory status,
the capacity recovery rate is more than 90% of 10A discharge capacity
100% is 1,950mAh at 25℃ with SOC 100% after formation.

- 2/18 -
-SAMSUNG SDI Confidential Proprietary –

Spec. No. INR18650-20S Version No. 1.0

4.0 Outline dimensions

See the attachment (Fig. 1)

Max. 18.43mm

Max. 65.00mm

Unit : mm
With tube

Fig.1. Outline dimensions of INR110500-20S

- 3/18 -
-SAMSUNG SDI Confidential Proprietary –

Spec. No. INR18650-20S Version No. 1.0

5.0. Appearance

There shall be no such defects as scratch, rust, discoloration, leakage which


may adversely affect commercial value of the cell.

6.0. Standard test conditions

6.1 Environmental conditions


Unless otherwise specified, all tests stated in this specification are conducted at
temperature 25±5℃ and humidity 65±20%.

6.2 Measuring equipments


(1) Amp-meter and volt-meter
The amp-meter and volt-meter should have an accuracy of the grade 0.5mA and
mV or higher.
(2) Slide caliper
The slide caliper should have 0.01 mm scale.
(3) Impedance meter
The impedance meter with AC 1 kHz should be used.

7.0. Characteristics

7.1 Standard charge


This "Standard charge" means charging the cell CCCV with charge current 0.5CmA
(1,000mA), constant voltage 4.2V and 100mA cut-off in CV mode at 25℃ for capacity.
.
7.2 Rated charge
Rated charge means charging the cell CCCV with charge current 4A and 100mA cut-off
at 25℃

7.3 Standard discharge capacity


The standard discharge capacity is the initial discharge capacity of the cell, which is
measured with discharge current of 400mA(0.2C) with 2.5V cut-off at 25℃ within 1hour
after the standard charge.

Standard discharge capacity ≥ 2,000mAh

7.4 Rated discharge capacity


The rated discharge is the discharge capacity of the cell, which is measured with
discharge current of 10A with 2.5V cut-off at 25℃ within 1hour after the rated charge.

Standard rated discharge capacity ≥ 1,950mAh

- 4/18 -
-SAMSUNG SDI Confidential Proprietary –

Spec. No. INR18650-20S Version No. 1.0

7.5 Initial internal impedance


Initial internal impedance measured at AC 1kHz after standard charge

Initial internal impedance ≤ 15mΩ

7.6 Temperature dependence of discharge capacity


Capacity comparison at each temperature, measured with discharge
constant current 10A and 2.5V cut-off after the standard charge is as follows.

Discharge temperature
-20℃ -10℃ 0℃ 25℃ 60℃
60% 75% 80% 100% 100%

Note: If charge temperature and discharge temperature is not the same,


the interval for temperature change is 3 hours.
Percentage index of the discharge at 25℃ at 10A (=1,950mAh) is 100%.

7.7 Temperature dependence of charge capacity


Capacity comparison at each temperature, measured with discharge constant current
10A and 2.5V cut-off after the standard charge is as follows.

Charge temperature Discharge temperature


0℃ 5℃ 25℃ 50℃
25℃
Relative capacity 80% 90% 100% 95%

Note: If charge temperature and discharge temperature is not the same,


the interval for temperature change is 3 hours.
Percentage index of the discharge at 25℃ at 10A (=1,950mAh) is 100%.

7.8 Discharge rate capabilities


Discharge capacity is measured with the various currents in under table and 2.5V
cut-off after the standard charge.

Discharge condition
Current 0.4A 5A 10A 15A 20A
Relative Capacity 100% 97% 100% 97% 95%

Note: Percentage index of the discharge at 25℃ at 10A (=1,950mAh) is 100%.

- 5/18 -
-SAMSUNG SDI Confidential Proprietary –

Spec. No. INR18650-20S Version No. 1.0

7.9 Cycle life


With rated charge and maximum continuous discharge.
Capacity after 250cycles,

Capacity ≥ 1,200mAh (60% of the standard capacity at 25℃)

7.10 Storage characteristics


Rated discharge capacity after storage for 1 month at 60℃ from the standard charged
state is ≥ 90% of the rated discharge capacity (=1,950mAh) at 25℃

7.11 Status of the cell as of ex-factory


The cell should be shipped in 3.60V ~ 3.80V Charging voltage range.

8.0. Mechanical Characteristics

8.1 Drop test


Test method: Fully rated charged Cells drop onto the concrete floor from 1.0m height
at a random direction 3 times. The cells or batteries are dropped so as to
obtain impacts in random orientations. After the test, the sample shall be
put on rest for a minimum of one hour and then a visual inspection shall
be performed.

Criteria: No fire, no explosion.


Drop test shall be performed with the IEC62133 standard

8.2 Vibration test


Test method: As to the UN transportation regulation (UN38.3), for each axis (X and
Y axis with cylindrical cells) 7Hz→200Hz→7Hz for 15min, repetition
12 times totally 3hours, the acceleration 1g during 7 to 18Hz and 8g
(amplitude 1.6mm) up to 200Hz.

Criteria: No leakage, with less than 10mV of OCV drop


Vibration test shall be performed with the UN38.3 standard

9.0. Safety

9.1 Overcharge test


Test method: Cell is to be discharged at a constant current of 0.4A to 2.5V. The cell is
then to be charged with a 20 V and 20A. Charging duration is to be 7 h.

Criteria: No fire, and no explosion.


Overcharge test shall be performed with the UL1642 standard

- 6/18 -
-SAMSUNG SDI Confidential Proprietary –

Spec. No. INR18650-20S Version No. 1.0

9.2 External short-circuit test


Test method: Fully rated charged cell is to be short-circuited by connecting the positive
and negative terminals of the battery with a circuit load having a
resistance load of 80 ±20 mW. The battery is to discharge until a fire or
explosion is obtained, or until it has reached a completely discharged
state of less than 0.2 V and the battery case temperature has returned to
±10°C of ambient temperature. The return to near ambient of the battery
(cell) casing in an indication of ultimate results.

Criteria: No fire, and no explosion


External short-circuit test shall be performed with the UL1642 standard

9.3 Forced discharge test


Test method: A discharged cell is subjected to a reverse charge at 1.0C (2.0A)
for 90 min.

Criteria: No fire, and no explosion.


Forced discharge test shall be performed with the IEC62133 standard

9.4 Heating test


Test method: To heat up the standard charged cell at heating rate 5℃ per minute up to
130℃ and keep the cell in oven for 1 hour.

Criteria: No fire, and no explosion.

10.0. Warranty

Samsung SDI will be responsible for replacing the cell against defects or poor workmanship
for 15months from the date of shipping. Any other problem caused by malfunction of the
equipment or mix-use of the cell is not under this warranty.

The warranty set forth in proper using and handling conditions described above and
excludes in the case of a defect which is not related to manufacturing of the cell.

11.0. Others

11.1 Storage for a long time


If the cell is kept for a long time (3 months or more), It is strongly recommended
that the cell is preserved at dry and low-temperature.

11.2 Others
Any matters that specifications do not have, should be conferred with between the
both parties.

- 7/18 -
-SAMSUNG SDI Confidential Proprietary –

Spec. No. INR18650-20S Version No. 1.0

12.0. Packing

See the Fig.2, Package Drawing

Fig 2. Package Drawing

- 8/18 -
-SAMSUNG SDI Confidential Proprietary –

Spec. No. INR18650-20S Version No. 1.0

Proper use and handling of lithium ion cells


See before using lithium-ion cell
Supplied by
Samsung SDI Co., Ltd.

1.0. General

This document has been prepared to describe the appropriate cautions and
prohibitions, which the customer should take or employ when the customer uses
and handles the lithium ion cell to be manufactured and supplied by Samsung SDI Co.,
Ltd., in order to obtain optimal performance and safety.

2.0. Charging

2.1 Charging current


Charging current shall be less than maximum charge current specified in the product
specification.

2.2 Charging voltage


Charging shall be done by voltage less than that specified in the product specification.

2.3 Charging time


Continuous charging under specified voltage does not cause any loss of performance
characteristics. However, the charge timer is recommended to be installed from a safety
consideration, which shuts off further charging at time specified in the product
specification.

2.4 Charging temperature


The cell shall be charged within a range of specified temperatures in the specification.

2.5 Reverse charging


The cell shall be connected, confirming that its poles are correctly aligned.
Inverse charging shall be strictly prohibited. If the cell is connected improperly, it may be
damaged.

3.0. Discharging

3.1 Discharging
3.1.1 The cell shall be discharged continuously at less than maximum discharge current
specified in the product specification. In case of the higher discharge current
should be set, it shall be discussed together with SDI.

3.2 Discharging temperature


3.2.1 The cell shall be discharged within a range of temperatures specified in
the product specification.

- 9/18 -
-SAMSUNG SDI Confidential Proprietary –

Spec. No. INR18650-20S Version No. 1.0

3.2.2 Otherwise, it may cause loss of performance characteristics.

3.3 Over-discharging
3.3.1 The system should equip with a device to prevent further discharging
exceeding discharging cut-off voltage specified in the product specification.
3.3.2 Over-discharging may cause loss of performance characteristics of battery.
3.3.3 Over-discharging may occur by self-discharge if the battery is left for
a very long time without any use.
3.3.4 The charger should equip with a device to detect voltage of cell block and to
determine recharging procedures.

4.0. Storage

4.1 Storage conditions


4.1.1 The cell should be stored within a range of temperatures specified
in the product specification.
4.1.2 Otherwise, it may cause loss of performance characteristics, leakage and/or rust.

4.2 Long-term storage


4.2.1 The cell should be used within a short period after charging because
long-term storage may cause loss of capacity by self-discharging.
4.2.2. If long-term storage is necessary, the cell should be stored at lower
voltage within a range specified in the product specification, because
storage with higher voltage may cause more loss of performance characteristics.

5.0. Cycle life

5.1 Cycle life performance


5.1.1 The cell can be charged/discharged repeatedly up to times specified in
the product specification with a certain level of capacity specified in the
product specification.
5.1.2 Cycle life may be determined by conditions of charging, discharging,
operating temperature and/or storage.

6.0. Design of system

6.1 Connection between the cell and the battery


6.1.1 The cell should not be soldered directly with other cells. Namely, the cell
should be welded with leads on its terminal and then be soldered with
wire or leads to solder.
6.1.2 Otherwise, it may cause damage of component, such as separator and
insulator, by heat generation.

- 10/18 -
-SAMSUNG SDI Confidential Proprietary –

Spec. No. INR18650-20S Version No. 1.0

6.2 Positioning the battery in the system


6.2.1 The battery should be positioned as possible as far from heat sources
and high temperature components.
6.2.2 Otherwise, it may cause loss of characteristics.
6.2.3 The recommended spacing between the cells is more than 1mm.

6.3 Mechanical shock protection of the battery


6.3.1 The battery should be equipped with appropriate shock absorbers in the pack
in order to minimize shock, which can damage the cells.
6.3.2 Otherwise, it may cause shape distortion, leakage, heat generation
and/or rupture and/or open circuit.

6.4 Short-circuit protection of the cell


6.4.1 The cell equips with an insulating sleeve to protect short-circuit which
may occur during transportation, battery assembly and /or system operation.
6.4.2 If the cell sleeve is damaged by some cause such as outside impact,
it may cause short-circuit with some wiring inside the battery.

6.5 Connection between the battery and charger/system


6.5.1 The battery should be designed to be connected only to the specified
charger and system.
6.5.2 A reverse connection of the battery, even in the specified system,
should be avoided by employing special battery design such as
a special terminals.

6.6 Pack design


6.6.1 The current consumption of the battery pack should be under 10uA
at sleep mode.
6.6.2 Cell voltage monitoring system.
The system (charger or pack) should be equipped with a device to monitor each
voltage of cell block to avoid cell imbalance which can cause damage to the cells.
6.6.3 The battery pack or system should have warning system such as over temperature,
over voltage, over current, and so on.

7.0. Battery pack assembly

7.1 Prohibition of usage of damaged cell


7.1.1 The cell should be inspected visually before battery assembly.
7.1.2 The cell should not be used if sleeve-damage, can-distorsion and/or
electrolyte-smell is detected.

7.2 Terminals handling


7.2.1 Excessive force on the negative terminal should be avoided when
external strip terminal is welled.

7.3 Transportation
7.3.1 If the cell is necessary to be transported to such as the battery manufacturer,
careful precautions should be taken to avoid damage of cell.

- 11/18 -
-SAMSUNG SDI Confidential Proprietary –

Spec. No. INR18650-20S Version No. 1.0

8.0. Others

8.1 Disassembly
8.1.1 The cell should not be dismantled from the battery pack.
8.1.2 Internal short-circuit caused by disassembly may lead to heat generation
and/or venting.
8.1.3 When the electrolyte is coming in contact with the skin or eyes,
flush immediately with fresh water and seek medical advice.

8.2 Short-circuiting
8.2.1 Short-circuit results in very high current which leads to heat generation.
8.2.2 An appropriate circuitry should be employed to protect accidental
short-circuiting.

8.3 Incineration
8.3.1 Incinerating and disposing of the cell in fire are strictly prohibited,
because it may cause rupture and explosion.

8.4 Immersion
8.4.1 Soaking the cell in water is strictly prohibited, because it may cause
corrosion and leakage of components to be damaged to functions

8.5 Mixing use


8.5.1 Different types of cell, or same types but different cell manufacturer's shall not be
used, which may lead to cell imbalance, cell rupture or damage to system due to
the different characteristics of cell.

8.6 Battery exchange


8.6.1 Although the cell contains no environmentally hazardous component,
such as lead or cadmium, the battery shall be disposed according to
the local regulations when it is disposed.
8.6.2 The cell should be disposed with a discharged state to avoid heat generation
by an inadvertent short-circuit.

8.7 Caution
The Battery used in this device may present a risk of fire or chemical burn if
mistreated.
Do not disassemble, expose to heat above 100℃ or incinerate it.
Replace battery with those of Samsung SDI only.
Use of another battery may cause a risk of fire or explosion.
Dispose of used battery promptly.
Keep battery away from children.
Do not disassemble and do not dispose of battery in fire.

8.8 Warning – Attached

- 12/18 -
-SAMSUNG SDI Confidential Proprietary –

Spec. No. INR18650-20S Version No. 1.0

▣ Pack Design Guideline (For electrical design)

Item Portable IT Power-Tool Medical E-Bike E-Scooter EV/LEV ESS/UPS

4.00V
□ Standard charging voltage (4.20V cell) 4.20V 4.20V 4.10V 4.10V 4.10V 4.10V
(4.05V)
4.00V
□ Standard charging voltage (4.35V cell) 4.35V 4.35V 4.20V 4.20V 4.20V 4.20V
(4.05V)

□ Charging method CC-CV CC-CV CC-CV CC-CV CC-CV CC-CV CC-CV

0.025C
□ Full-charging cut-off current* 0.05C 0.05C 0.025C 0.025C 0.025C 0.025C
(Continous)
4.00V
□ Voltage of Re-charging (4.20V cell) 4.10V 4.10V 4.05V 4.05V 4.05V 4.05V
(4.05V)
4.00V
□ Voltage of Re-charging (4.35V cell) 4.25V 4.25V 4.10V 4.10V 4.10V 4.10V
(4.05V)
□ Min. voltage of
3.00V 2.50V 3.00V 3.00V 3.00V 3.00V 3.00V
LCO terminate discharging
LMO □ Min. voltage of
2.50V 2.00V 2.50V 2.50V 2.50V 2.50V 2.50V
over-discharging protection
□ Min. voltage of
2.50V 2.50V 2.50V 2.50V 2.50V 2.50V 2.50V
NCA terminate discharging
NCM □ Min. voltage of
2.30V 2.00V 2.50V 2.50V 2.50V 2.50V 2.50V
over-discharging protection
□ BMS Shut Down Voltage** 2.00V 2.00V 2.00V 2.00V 2.00V 2.00V 2.00V

□ Max. consumption current of BMS


10㎂/Cell 10㎂/Cell 10㎂/Cell 10㎂/Cell 10㎂/Cell 10㎂/Cell 10㎂/Cell
after shut down
□ Do not charge*** ↓ 1.00V ↓ 1.00V ↓ 1.00V ↓ 1.00V ↓ 1.00V ↓ 1.00V ↓ 1.00V

□ Pre-charging voltage range**** 1.0V ~ 3.0V 1.0V ~ 3.0V 1.0V ~ 3.0V 1.0V ~ 3.0V 1.0V ~ 3.0V 1.0V ~ 3.0V 1.0V ~ 3.0V

□ Current range of Pre-charging 0.1C ~ 0.5C 0.1C ~ 0.5C 0.1C ~ 0.5C 0.1C ~ 0.5C 0.1C ~ 0.5C 0.1C ~ 0.5C 0.1C ~ 0.5C

Remark:
* Current of cell which full-charging shall be terminated.
** Voltage condition of BMS which shall be shut down.
*** Under 1.0V voltage, do not charge the cell.
**** Voltage range of cell which shall be charged by Pre-charging.

If a customer’s battery pack cannot meet the requirements above,


SDI cannot take responsibility for a quality issue about a battery cell.

- 13/18 -
-SAMSUNG SDI Confidential Proprietary –

Spec. No. INR18650-20S Version No. 1.0

▣ Pack Design Guideline (For mechanical design)

Item Portable IT Power-Tool Medical E-Bike E-Scooter EV/LEV ESS/UPS

□ Need partitions(separator) between


BMS and a Cell ◎ ◎ ◎ ◎ ◎ ◎ ◎

□ Need to check if the pack is designed


to be able to avoid thermal runaway ◎ ◎ ◎
(1KWh↑)
□ Need to analyze the battery pack's
thermal distribution and its effect ◎ ◎ ◎
on the pack's life cycle
□ Need to use a non-flammable
(VO level) case ◎ ◎ ◎ ◎ ◎ ◎ ◎

□ Need to apply improved material


(Steel) to the case ◎ ◎

□ Need to analyze the battery pack's


structure, system, installation status ◎ ◎
and use environment

If a customer’s battery pack cannot meet the requirements above,


SDI cannot take responsibility for a quality issue about a battery cell.

- 14/18 -
-SAMSUNG SDI Confidential Proprietary –

Spec. No. INR18650-20S Version No. 1.0

Handling precaution and prohibitions of lithium Ion rechargeable cells and


batteries
Inaccurate handling of lithium ion and lithium ion polymer rechargeable battery may cause leakage, heat,
smoke, an explosion, or fire.
This could cause deterioration of performance or failure. Please be sure to follow instructions carefully.

1.1 Storage
Store the battery at low temperature (below 25℃ is recommended), low humidity, no dust and no
corrosive gas atmosphere.

1.2 Safety precaution and prohibitions


To assure product safety, describe the following precautions in the instruction manual of the
application.

[ Danger! ]
■ Electrical misusage
Use stipulated charger.
Use or charge the battery only in the stipulated application.
Don't charge the battery by an electric outlet directly or a cigarette lighter charger.
Don't charge the battery reversely.

■ Environmental misusage
Don't leave the battery near the fire or a heated source.
Don't throw the battery into the fire.
Don't leave, charge or use the battery in a car or similar place where inside of temperature may be
over 60℃.
Don't immerse, throw, wet the battery in water / sea water.

■ others
Don't fold the battery cased with laminated film such as pouch and polymer.
Don't store the battery in a pocket or a bag together with metallic objects such as keys, necklaces,
hairpins, coins, or screws.
Don't short circuit (+) and (-) terminals with metallic object intentionally.
Don't pierce the battery with a sharp object such as a needle, screw drivers.
Don't heat partial area of the battery with heated objects such as soldering iron.
Don't hit with heavy objects such as a hammer, weight.

- 15/18 -
-SAMSUNG SDI Confidential Proprietary –

Spec. No. INR18650-20S Version No. 1.0

Don't step on the battery and throw or drop the battery on the hard floor to avoid mechanical shock.
Don't disassemble the battery or modify the battery design including electric circuit.
Don't solder on the battery directly.
Don't use seriously scared or deformed battery.
Don't put the battery into a microwave oven, dryer or high-pressure container.
Don't use or assemble the battery with other makers' batteries, different types and/or models of
batteries such as dry batteries, nickel-metal hydride batteries, or nickel-cadmium batteries.
Don't use or assemble old and new batteries together.

[ Warning! ]
Stop charging the battery if charging isn't completed within the specified time.
Stop using the battery if the battery becomes abnormally hot, order, discoloration, deformation, or
abnormal conditions is detected during use, charge, or storage.
Keep away from fire immediately when leakage or foul odors are detected. If liquid leaks onto your
skin or cloths, wash well with fresh water immediately.
If liquid leaking from the battery gets into your eyes, don't rub your eyes and wash them with clean
water and go to see a doctor immediately.
If the terminals of the battery become dirty, wipe with a dry cloth before using the battery.
The battery can be used within the following temperature ranges. Don't exceed these ranges.
The operating temperature is based on the cell surface temperature in hottest position in pack.
Charge temperature ranges : 0℃ ~ 50℃
Discharge Temperature ranges : -20℃ ~ 75℃
Store the battery at temperature below 60℃
Cover terminals with proper insulating tape before disposal.

[ Caution! ]
■ Electrical misusage
Battery must be charged with constant current-constant voltage (CC/CV).
Charge current must be controlled by specified value in cell specification.
Cut-off voltage of charging must be less than 4.2V
Charger must stop charging battery by detecting either charging time or current specified in cell’s
specification.
Discharge current must be controlled by specified value in cell’s specification.
Cut-off voltage of full discharging and recharging must be over 2.5V.

- 16/18 -
-SAMSUNG SDI Confidential Proprietary –

Spec. No. INR18650-20S Version No. 1.0

■ others
Keep the battery away from babies and children to avoid any accidents such as swallow.
If younger children use the battery, their guardians should explain the proper handling method and
precaution before using.
Before using the battery, be sure to read the user's manual and precaution of it's handling.
Before using charger, be sure to read the user's manual of the charger.
Before installing and removing the battery from application, be sure to read user's manual of the
application.
Replace the battery when using time of battery becomes much shorter than usual.
Cover terminals with insulating tape before proper disposal.
If the battery is needed to be stored for an long period, battery should be removed from the
application and stored in a place where humidity and temperature are low.
While the battery is charged, used and stored, keep it away from object materials with static electric
chargers.

Safety handling procedure for the transporter


■ Quarantine
Packages that are crushed, punctured or torn open to reveal contents should not be
transported. Such packages should be isolated until the shipper has been consulted,
provided instructions and, if appropriate, arranged to have the product inspected and
repacked.

■ Spilled product
In the event that damage to packaging results in the release of cells or batteries,
the spilled products should be promptly collected and segregated and the shipper
should contact for instructions.

Design of positioning the battery pack in application and charger


To prevent the deterioration of the battery performance caused by heat, battery shall be positioned
away from the area where heat is generated in the application and the charger.

- 17/18 -
-SAMSUNG SDI Confidential Proprietary –

Spec. No. INR18650-20S Version No. 1.0

Design of the battery pack


Be sure adopting proper safe device such as PTC specified type or model in Cell Specification. If you
intend to adopt different safety device which is not specified in Cell Specification, please contact
Samsung SDI to investigate any potential safety problem.
Be sure designing 2nd protective devices such as PCM at the same time to protect cell just in case one
protective device is fault.
Please contact following offices when you need any help including safety concerns.

Samsung SDI emergency contact information

■ Samsung SDI Headquarter.


150-20, Gongse-ro, Giheung-gu, Yongin-si, Gyunggi-do, Korea
Tel: +82-31-8006-3100, Fax : +82-31-210-7887

■ Samsung SDI Cheonan Factory.


467, Beonyeong-ro, Seobuk-gu, Cheonan-si, Chungcheongnam-Do, Korea
Tel: +82-41-560-3114, Fax : +82-41-550-3399

■ Samsung SDI America Subsidiary


3655 North First St. San Jose CA 95134
Tel: +1-408-544-4541, Fax : +1-949-260-2221

■ Samsung SDI Taiwan Branch


9F-1, 399 Ruey Kuang Road, Neihu, Taipei, Taiwan
Tel: +886-2-2656-8300, Fax : +886-2-2656-8329

■ Samsung SDI Malaysia factory.


Lot 635 & 660, Kawasan Perindustrian, Tuanku Jaafar, 71450
Sungai Gadut, Negeri Sembilan Darul Khusus, Malaysia
Tel: (+60)6-677-6160, 6153

- 18/18 -