0% found this document useful (0 votes)
61 views

FG 095050

Uploaded by

Muhammad Novan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
0% found this document useful (0 votes)
61 views

FG 095050

Uploaded by

Muhammad Novan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
You are on page 1/ 5
Instructions-Parts List Fire Alarm autoshutdown Part Number: FG-095050 Foal RD “This manual containe important warnings and infarmation. READ AND KEEP FOR REFERENCE. Description: FG-095050 is used to control and monitor all type of Fire suppression system, It is equipped with auto shut- down relay the features as following: 1. Very easy installation (No special tool, no special programming and no timing code needed and No tampering problem) 2. Bolts, nuts and screw set included 3. Economic price 4. Compact design (Dimension: 140mm x 70mm x SOmm) S. Light weight (56.7 grams) Characteristics - Voltage: 12VDC, 24VDC & 48VDC “Factory setting FG-095050, Fire alarm Paces Catalog No. 303-01, Instructions-Parts List Dimensions and cover explaination Enclosure Cover Yellow LED - Indicates Cylinder Pressure low Red LED — - Indicates Fire Alarm Yellow LED - indicates engine shutdown Green LED - Indicates power is applied to the panel NO -Normaly open NC. -Normaly Close 24V - Allowable for 12VDC, 24VDC & 48VDC HP. -High pressure Ov - Negative / Grounding LP -Low pressure - Negative / Grounding 2.75°(70mm) ee O78" (om) Page2 30" (100mm) oe" (20m) FoAMeDARD 75mm) i i 2 a 5 coal 88.04 Instructions-Parts List Field Connections 53,7» Yellow LED « Red LED « Yellow LED « Green LED + 56 Wiring Diagram 1. Incoming Power: 12VDC, 24VDC & 48VDC 2. Positive Pressure switch 1200kpa 3. Grounding timer 4. Positive Pressure switch 300kpa 5. Negative / grounding Pressure switch 1200kpa 6. Negative / grounding Pressure switch 300kpa Z\WARNING Power supply must be off while making any connections. Pages FOAMGDARD Catalog No, 803-01 Instructions-Parts List Problem and trouble shooting FOAMGDARD’ Condition Possible Cause Corrective Action Panel does not operate. Power LED light is off No power to panel ‘Turn on electric power, Check fuse, check electric wire and all connections Buzzer alarm and/or Fire alarm LED is on cylinder tank was empty Refill cylinder tank Reset/ test button switch was actived Push button again High pressure switch is connected (under pressurized tank) Check Tank pressure, Check wiring from short circuit, Replace pressure switch Cylider pressure low LED is on Low pressure switch is connected (under pressurized tank) (Check Tank pressure, Check wiring from short circuit, Replace pressure switch Engine shutdown LED is On [Delay shutdown button switch was actived Push Delay shutdown button again Delay timer is working. Push Reset/ test button Catalog No, 903-01 Instructions-Parts List FOAMSDARD Foamguard Standard Warranty Foamguard warrants all equipment manufactured by Foamguard and bearing its name to be free from defects in material and workmanship on the date of sale by an authorized Foamguard distributor to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Foamguard, Foamguard will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Foamguard to be defective. This warranty applies only when the equip- ment is installed, operated and maintained in accordance with Foamguard’s written recommendations. This warranty does not cover, and Foamguard shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper. maintenance, negligence, accident, tampering, or substitution of non-Foamguard component parts. Nor shall Foamguard be liable for malfunction, damage or wear caused by the incompatibility of Foamguard equipment with structures, accessories, equipment or materials not supplied by Foamguard, or the improper design, manufacture, installation, operation or maintenance of structures, accessories, equip- ment or materials not supplied by Foamguard. This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Foamguard distributor for verification of the claimed defect. If the claimed defect is verified, Foamguard will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation. THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE. Foamguard’s sole obligation and buyer's sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale. Foamguard makes no warranty, and disclaims all implied warranties of merchantability and fitness for a particular purpose in connection with accessories, equipment, materials or components sold but not manufactured by Foamguard. These items sold, but not manufactured by Foamguard (such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Foamguard will provide purchaser with reasonable assistance in making any claim for breach of these warranties. In no event will Foamguard be liable for indirect, incidental, special or consequential damages resulting from Foamguard supplying equipment hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due toa breach of contract, breach of warranty, the negligence of Mul- tilube, or otherwise. Foamguard Information For the latest information about Foamguard products, visit www.foamguard-firesuppression.com TO PLACE AN ORDER, contact your Foamguard distributor or call to identify the nearest distributor. Pate Catalog No, 803-01

You might also like