1eec E4001
1eec E4001
TRUE NORTH
KEY PLAN
MANYAR SMELTER
MATCHLINE FOR CONTINUATION
DESALINATION PLANT
SEE MSD-DD-5490-ELE-DWG-4041 MATCHLINE FOR CONTINUATION SEE MSD-DD-5436-ELE-DWG-4011
A
A
L90-5435-SJ-201-M, EL. 13850
1 L90-5435-SJ-101-M, EL. 13350
PSA PSB PSC PSD PSE PSF 7RI.5 L90-5435-SP-201-M, EL. 12850
THIS DWG
4041
L90-5435-SP-101-S, EL. 12350
ON
(4) 900mm STR
110 110
NUATI
900mm DO
DW G-
295
PS2
7R11
NE FOR CONTI
ELE-
2
7R9
C
C
NOTES
7R7
D
1. ALL DIMENSIONS AND ELEVATIONS ARE IN MILLIMETER AND COORDINATED ARE IN METER UNLESS D
OTHERWISE NOTED.
7R6
800
5. ALL CABLE TRAY NUMBERS SEPARATED WITH A FORWARD SLASH ( / ) INDICATES A DIVIDED TRAY.
SEE MSD-DD-5466-ELE-DWG-4002
ALL DIVIDED TRAYS HAVE THE DIVIDER LOCATION IN THE CENTER LINE OF THE TRAY UNLESS
OTHER WISE NOTED.
1 7R5 6. ALL MEDIUM VOLTAGE CABLE TRAY WILL BE SHOWN AT THE SIDE RAIL TRAY WITH
"DANGER - HIGH VOLTAGE - KEEP AWAY" EVERY 15 METERS STRAIGHT SECTIONS.
E
4002
E
3 7. THE COVERS SHALL BE PROVIDED ON CABLE TRAY INSTALLED OUTDOORS AT THE TOP LAYER OF ALL
STACKED. COVERS ARE REQUIRED TO PROTECT FROM FALLING OBJECT AND CORROSIVE MATERIALS,
THIS DWG
DUSTY AREAS, DIRECT SOLAR RADIATION (SUNLIGHT) AND MECHANICAL DAMAGE DURING
7RA 7RB 7RC 7RD 7RE 7RF 7RG 7RH 7RI MAINTENANCE.
8. THE CONTRACTOR SHALL INSTALL EXPANSION SPLICE PLATES EVERY STRAIGHT RUN CABLE TRAY
OUTDOOR 50 METERS.
7R4 9. THE CONTRACTOR SHALL IDENTIFY TRAY NUMBER AT SIDE RAIL TRAY BY NOT EXCEEDING 15 METERS ON
STRAIGHT SECTIONS AND WITHIN 1.5 METERS OF ALL TRAY INTERSECTION AND NUMBERING CHANGE
LOCATIONS. TRAY NUMBER SHALL BE SHOWN ON THE ONE SIDE RAIL TRAY WHERE PERSONAL CAN
EASILY BE SEEN FROM GRADE LEVEL.
L90-5435-SJ-105-M, EL. 12850
L90-5435-SP-105-M, EL. 12350 10. HORIZONTAL TRAY SHALL BE SUPPORTED AT INTERVALS NOT EXCEEDING 3.0 METERS AND VERTICAL TRAYS
(2) 900mm STR SHALL BE SUPPORTED AT INTERVALS NOT EXCEEDING 2.5 METERS WHEN MEASURED ALONG
F
THE CENTERLINE OF STRAIGHT TRAY SECTION RUNS. STRAIGHT SECTIONS AND FITTINGS SHALL BE F
150
7R1
2000
H
H
7RJ 7RK
I
I
7RJ
FUTURE AREA
7RJ
2685
J 7065
2400 J
900mm HT
295 900mm 30° OVE
900mm STR
EL. 12350 900mm STR
EL. 12350
APPROVED FOR
900mm STR
900mm 30° IVE
900mm STR
900mm 90° IVE
900mm HT
L90-5435-SJ-106-M, EL. 11200
L90-5435-SP-106-M, EL. 10700
900mm HT
CONSTRUCTION
L90-5435-SJ-201-M, EL. 13850 L90-5435-SP-202-M, THE DISTRIBUTION AND USE OF THE NATIVE FORMAT CAD
L90-5435-SJ-101-M, EL. 13350 900mm STR 900mm DO FILE OF THIS DRAWING IS UNCONTROLLED. THE USER
900mm HT DO SHALL VERIFY TRACEABILITY OF THIS DRAWING TO THE
K L90-5435-SP-201-M, EL. 12850 L90-5435-SJ-104-M, EL. 12850
K
LATEST CONTROLLED VERSION.
L90-5435-SP-101-S, EL. 12350 L90-5435-SP-104-M, EL. 12350 L90-5435-SJ-102-M, EL. 9150
SECTION 3
L90-5435-SP-102-S/L90-5435-SP-102-M, EL. 8650
900mm DO SCALE: 1:100
900mm HT L90-5435-SP-104-S R
TPG
CABLE TRAY
ze 1 = 1
A0 1:125
0 PPL TPG WBA MAR,31,2023 ISSUED FOR CONSTRUCTION MSD-DD-5420-STR-STA-6970 THRU 6976 CABLE TRAY SUPPORT DETAIL SERIES DRAWING
21 AM
E NKT TPG WBA NOV,11,2022 ISSUED FOR OWNER APPROVAL (IFA) Originator Document No: REV. DRAWING NO. REV.
03/31/2023 08:
NO. DRAWN CHECKED APPROVED DATE DESCRIPTION DWG NO. REFERENCE DRAWINGS DWG NO. REFERENCE DRAWINGS 411870-1EEC-E4001 0 MSD-DD-5435-ELE-DWG-4001 0
pon55799
1 2 3 4 5 6 7 10 11 12 13 14 15 16