Draft Survey Certificate for Coal Shipment
Draft Survey Certificate for Coal Shipment
IBIS
I'fSTINC SUIi.VTY
il{ST'TC'I{}N
S
$
5a*arirde. Ka!in:antan Iimur
+52 812 5415 15t3
+6: 8;1 5876 !ll$
bo;rreoinspekriF-efi ai1.l$in
This is to ceftify that we have performed the inspection of draft survey on board of Barge nominated as Below :
This draft survey was done with the Chief Officer of the sald tug boat in attendance. From the figures ol:tained by means of the
barge's draft checked at the time initial and final draft surveys it was conclude that the total weight of cargo loaded ot1 board
the above barge. proved to be :
7_307,961 MT
Signed for and on behalf of lssued by PT. lndo Borneo lnspeksi services
PT. lndo At Banjarbaru, South Kalimantan
Date January 73,2022
Certf. No. o07lsu Prlr Brs -B JB / v 2022
Ops. Coordinator
Thisreportresfectsourtindingattimeandplaceofinspectionanddoesnotrefertoanyothermatter. Thisreport
that it does not relieve partles from their contractual ollligations. All inspection covered in this teport have lleen l
and in accordance with practice and standard generally accepted in trade. Our responsibiiity is iimited to the
S
$
*6? B1:5455 15!$
t0? Sr'i 5876 51 9
borrie*inspeksi('qnr;il.rom
Quantity : 7.307,961- MT
THIS lS TO CERTIFY, that upon request of the Principals, we have proceeded to the barge concerned for the purpose of conducting draught
readingatinitial andfinal stagetoestablishthequantityoftheconsigmentloadedthrough calculationoftherespectivedisplacementof light
and loaded barge based on figured obtained through draught reading.
Ops. Coordinator
This report resfects our tinding at time and place of inspection and does not refer to any other matter. This report is issued without prejudice ard on tile understanding
lhat it does not aelieve pa.ties from their coolractual obligations. All inspection covered in this report have been carried out to the best of our knowledge and ability
and in accordance with practice and standard generally accepted in trade. Our responsibility is limited to the ex€rcise of reasonallle care and due dilligence.
il.5!lta{ l.lalffrCirt Biiiarailie ll |tir E4 !l i4 RW 11 l_Jt i&'.,!J'dr.dp, {i.terr.,Edn (r llsfil. 1il (€l. [!illqglintlii!
{rl- 5!1,..jhil f€r Slk}fniri ii{.fl bar!. 5u1!Jtcr, sel.ltafl ro, :d,a;.u;.tr \Jl/ {-,Lnjqdr- :dnlo et! Ub ' d!:.' lawr 11;h lier ,afil,rr llfl$
"alitrr
is{. .6;9,, U,rU,Ot lrlr ,!iii(l ljxlrt I :ptp .{;.i')ll '5i9 l8jir !6):l-545i kg
'ili 11J :,t!:i 15!1 +6i 8?i -.difi 1891
.61 ljl 5871 5ll3 ''..8't8r 5:,' '6)95)/cZ(. Ela +-ql 11,5"c16 !]lq
Vtrant
,.til iri'i il l: i: lii
iil.rli r
LP-t361-tON
I'iit'i,: rti il ii-i
LP-.l36B.TDI.I
CERTIFICATE OF LI.154.IDN
IBIS
Jl.
lamarir:ia, {alrrnantan'[imur
S *g;*i:345515i9
TISTING SU}IVIY ",6J *i1 ,l87ii 1:l3rl
INSPLClI{)N $ h,:rnecitlpr:!1if)tmali.{rf n
Barge I Tug Boat : BG. FITRIA 3O05 / TB. ZINNIA
Quantity ; 7.307,961 MT
TO WHOM lT l\4AY CONCERN : This is to certjly thatwe have performed the inspection and analysis of coal shipment nominated below.
Geoeral Analysis and Total Moisture sample were taken during barge Ioading, number of lncrement calculated in accordance with ASTM formula depending on total cargo to
be sailpled. Since no prec;sron can be assigned for the above method of sampling. PT. lndo Borneo lnspeksi Services w;ll not held responsible for any descripancies in the
resampling and or analysis of result obtained. Sanlple Preparation, Testing and Analysis were performed at P L lndo Borneo lnspeksi Seryices in Banjarbaru in accordance
with ASTM Standard IMethods.
ANALYSIS RESULT:
{5/ g
RIKI SOMARA
Lab- Manager
Thrsreportresfecbourfrndrngattrmeandplaceofinspectionandd@snotrefertoanyothermater Thrsrepodlsissuedwithoutprejudiceandontheunderstanding
that it does not relieve padies from their mntractual obligations. All inspection covered in thjs repon have b*n
and ln accordance with pract ce and shndard generally accepted rn trade Our responsibllty is iimrted to the