Scheduled Oil Sampling Analysis Report

The document is a scheduled oil sampling report for a Caterpillar C18 engine (Unit W086-001) at a jobsite in Samarinda, Indonesia. It provides the results of oil analysis tests for 4 recent samples, including wear metal concentrations, additive levels, viscosity, particle counts, and other parameters. The oil in the most recent sample from November 9, 2019 showed normal wear metal levels and additive concentrations within acceptable ranges.

Uploaded by

omar soliman
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
104 views2 pages

Scheduled Oil Sampling Analysis Report

The document is a scheduled oil sampling report for a Caterpillar C18 engine (Unit W086-001) at a jobsite in Samarinda, Indonesia. It provides the results of oil analysis tests for 4 recent samples, including wear metal concentrations, additive levels, viscosity, particle counts, and other parameters. The oil in the most recent sample from November 9, 2019 showed normal wear metal levels and additive concentrations within acceptable ranges.

Uploaded by

omar soliman
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

PT.

Trakindo Utama S•O•S Fluids Analysis Laboratory


Scheduled Oil Sampling Report
Jl. Jendral Sudirman No.848, Balikpapan 76114, Indonesia
Tel. +62 542 762810, Call Center 1500 228

Customer Information Unit Information


RESOURCE EQUIPMENT INDONESIA PT. Category : Oil Equip Make : Caterpillar Received Date : 11/9/2019 8:20:00AM
ATTN: Resource Equipment Indonesia / Feronika (N) Lab No : B19K091413 Equip Model : C18 Lab Process Date : 11/09/2019 8:20AM
GD.SAMPOERNA STRATEGIC SQ SOUTH TOWER
Unit Number : W086-001 Sample Site/Location : PT KPUC SEPARI Sample Note :
LEVEL 18 JL. JEND.SUDIRMAN KAV.45-46
SEMANGGI,SETIABUDI, Indonesia 12930 Equip Serial : WRH01906 Jobsite : 324217A - SAMARINDA Reported Date : 11/9/2019 5:08:05PM
Compartment : Engine Job No :
Sample Point : Label No : B32 Evaluation Code B Monitor Compartment.
Phone 02129930772
Interpreted by : Trakindo HO EMS / Rini Prehati EM ext. 1074 (A)
Element Reading (mg/kg = ppm) - ASTM D-5185
Lab No. Sample Process Eval CMU SMU HOO Oil Added Fluid Filter Oil Type Oil Grade
Wear Metal Contaminant Additives
Date Date Chg Chg
Cr Pb Fe Cu Al Sn Ni B K Na Si Ca P Zn Mg Mo

B19K091413 06/Nov/19 09/Nov/19 B 13979 213 0 Y CASTROL SAE 15W-40 1 0 17 2 3 0 0 0 2 3 2 3147 857 978 154 0

B19J283109 24/Oct/19 28/Oct/19 B 13779 99 0 Y UNKNOWN SAE 15W-40 0 1 9 1 1 0 0 0 1 3 2 3256 939 1007 162 0

B19J112521 10/Oct/19 11/Oct/19 C 13578 261 0 Y CASTROL SAE 15W-40 2 0 23 3 2 1 0 0 1 3 3 2706 833 875 142 1

B19I182328 16/Sep/19 18/Sep/19 A 13398 81 0 N CASTROL SAE 15W-40 1 1 8 1 1 0 1 1 1 6 2 2965 1006 1015 156 0

Element Reading (mg/kg = ppm) Oil Condition (JOAP) ASTM E2412 Physical / Chemical Test Particle Count (Counts / ml) - ASTM D 4464

Lab No Ba * Ti * Ag * V* ST OXI NIT SUL FP (P/N) DF (%) V100 V40 VI TBN TAN W (P/N) W(%) PQ Visual PC 04 PC 06 PC 14 ISO 04 ISO 06 ISO 14
(cSt) (cSt) (idx)
B19K091413 42 28 11 32 N 11.6 5.7 N 0.0 -

B19J283109 23 28 10 29 N 10.8 7.2 N 1.0 -

B19J112521 39 46 12 42 P 8.7 3.3 N 0.0 -

B19I182328 9 20 8 23 N 12.5 8.7 N 0.0 -

Lab No. Tendency (5' Tendency (5' Tendency (5' Stability (10' Stability (10' Stability (10' Milipore Sludge
aeration) Seq 1 aeration) Seq 2 aeration) Seq 3 aeration) Seq 1 aeration) Seq 2 aeration) Seq 3 Test

B19K091413

B19J283109

B19J112521

B19I182328

Glossaries
Elements Ag=Silver P=Positive (0.5 - 0.8%) Visual
(ASTM D 5185) Note: Results = 0 < LoD (Limit of Detection) T=Trace (Cloudy but < 0.5%) LQ = Low Quantity
Si=Silicon (LoD=0.26) ppm=Parts Per Million E=Excessive (> 0.8%) MQ = Medium Quantity
AI=Aluminum (LoD=0.12) Particle Count Physical / Chemical HQ = High Quantity
Cr=Chromium (LoD=0.12) (ASTM D7647 & ASTM D7596) PQ=Particle Quantifier (Idx=Index) Met = Metallic
Fe=Iron (LoD=0.11) PC04=Particle Count at 4 micron TBN (mg KOH /g)=Total Base Number - ASTM D 4739 Non Met = Non Metallic
Pb=Lead (LoD=0.82) PC06=Particle Count at 6 micron TAN (mg KOH /g) =Total Acid Number - ASTM D664 F = Fine
Cu=Copper (LoD=0.01) PC14=Particle Count at 14 micron V100=Viscosity 100 °C - ASTM D445 C = Coarse
Sn=Tin (LoD=0.25) ISO4=ISO Code 4 V40=Viscosity 40 °C - ASTM D445 Granul = Granular
Ni=Nickel (LoD=0.38) SO6=ISO Code 6 cSt=Centistokes
Mg=Magnesium (LoD=0.01) ISO14=ISO Code 14 VI=Viscosity Index
Ca=Calcium (LoD=0.05) Oil Condition W(%)=Water Percentage
K=Potassium (LoD=0.64) ST=Soot FP Criteria Approved by
Na=Sodium (LoD=0.42) OXI=Oxidation FP=Flash Point (ASTM D 3828 - Method A)
P=Phosphorus (LoD=0.74) NIT=Nitration P=Positive
B=Boron (LoD=0.40) SUL=Sulfation N=Negative
Mo=Molybdenum (LoD=0.20) Water Criteria DF(%)=Dilution Fuel - ASTM D 3524
Zn=Zinc (LoD=0.17) W=Water - ASTM D6304 / ASTM D4377
Ti=Titanium % =Percentage
V=Vanadium N=Negative
Ba=Barium Mukhlisin
Manager S•O•S Laboratory

* Not Include Acreditation Scope


B19K091413 Page 1 of 2
PT. Trakindo Utama S•O•S Fluids Analysis Laboratory
Jl. Jendral Sudirman No.848, Balikpapan 76114, Indonesia
Tel. +62 542 762810, Call Center 1500 228

Customer Information Unit Information


RESOURCE EQUIPMENT INDONESIA PT. Category : Oil Equip Make : Caterpillar Received Date: : 11/9/2019 8:20:00AM
ATTN: Resource Equipment Indonesia / Feronika (N) Lab No : B19K091413 Equip Model : C18 Lab Process Date : 11/09/2019 8:20AM
GD.SAMPOERNA STRATEGIC SQ SOUTH TOWER Unit Number : W086-001 Sample Site/Location : PT KPUC SEPARI Sample Note :
LEVEL 18 JL. JEND.SUDIRMAN KAV.45-46 Equip Serial : WRH01906 Jobsite : 324217A - SAMARINDA Reported Date: : 11/9/2019 5:08:05PM
SEMANGGI,SETIABUDI, Indonesia 12930 Compartment : Engine Job No :
Sample Point : Label No : B32
Evaluation Code B Monitor Compartment.
Phone 02129930772 Interpreted by : Trakindo HO EMS / Rini Prehati EM ext. 1074 (A)

Recommendation** Rekomendasi**
LOW OIL VISCOSITY PROBABLY FUEL HAS ENTERED THE OIL BUT STILL NOT DETECTED OR INCORRECT VISKOSITAS OIL ENCER, KEMUNGKINAN BAHAN BAKAR TERCAMPUR DALAM OLI TAPI MASIH BELUM
TYPE OF OIL MAY BE USED. OXI, SOOT LEVEL AND SULFATE LEVEL SLIGHTLY ABOVE NORMAL DETECTED. TERDETEKSI ATAU MUNGKIN TIPE OLI YANG DIGUNAKAN TIDAK TEPAT. OXI, LEVEL SOOT DAN LEVEL SULFATE
BAD QUALITY OF FUEL MAY BE USED, POSSIBLE CAME FROM AIR CLEANER BLOCKED BY DUST. OTHER SEDIKIT DIATAS NORMAL. KEMUNGKINAN MENGGUNAKAN FUEL YANG BERKUALITAS BURUK. KEMUNGKINAN
READINGS ARE ACCEPTABLE. CLEAN OR REPLACE AIR FILTER ELEMENT. ENSURE TO USE GOOD QUALITY AIR CLEANER TERTUTUP OLEH DEBU. ELEMEN LAINNYA NORMAL. BERSIHKAN ATAU GANTI AIR FILTER
OF FUEL. SUGGEST TO INSPECT THE FUEL INJECTION SYSTEM AND DETERMINE THE SOURCE OF THE ELEMENT. PASTIKAN UNTUK MENGGUNAKAN KUALITAS FUEL YANG BAIK. SEBAIKNYA INSPEKSI SISTEM
INTERNAL FUEL LEAK.TAKE OIL SAMPLES AT 250 HOUR INTERVALS TO MONITOR CONDITION. PENGINJEKSIAN FUEL DAN TEMUKAN SUMBER KEBOCORAN INTERNAL FUEL.AMBIL SAMPEL OLI PADA
INTERVAL 250 JAM UNTUK MEMONITOR KONDISI.
Wear Metal Contaminant
140 100

120
80

100

Al 60
80 K
Cr Na
Fe Si
Pb ST
60 40
PQ

40
20
20

0 0

12/12/2017 2/11/2018 11/6/2018 1/8/2019 2/8/2019 3/28/2019 5/28/2019 7/15/2019 9/16/2019 10/24/2019 12/12/2017 2/11/2018 11/6/2018 1/8/2019 2/8/2019 3/28/2019 5/28/2019 7/15/2019 9/16/2019 10/24/2019
1/6/2018 5/12/2018 12/18/2018 1/28/2019 3/5/2019 4/11/2019 6/21/2019 9/4/2019 10/10/2019 11/6/2019 1/6/2018 5/12/2018 12/18/2018 1/28/2019 3/5/2019 4/11/2019 6/21/2019 9/4/2019 10/10/2019 11/6/2019

Oil Condition Viscosity


50 18

16

40 14

12
30
NIT 10
OXI
V100
SUL
TBN 8
20
6

10 4

0 0
12/12/2017 2/11/2018 11/6/2018 1/8/2019 2/8/2019 3/28/2019 5/28/2019 7/15/2019 9/16/2019 10/24/2019 12/12/2017 2/11/2018 11/6/2018 1/8/2019 2/8/2019 3/28/2019 5/28/2019 7/15/2019 9/16/2019 10/24/2019
1/6/2018 5/12/2018 12/18/2018 1/28/2019 3/5/2019 4/11/2019 6/21/2019 9/4/2019 10/10/2019 11/6/2019 1/6/2018 5/12/2018 12/18/2018 1/28/2019 3/5/2019 4/11/2019 6/21/2019 9/4/2019 10/10/2019 11/6/2019

If you need further information & dicussion, please kindly advised to contact us prior 7 days after report released (Jika di perlukan informasi & diskusi lebih lanjut dengan sample ini, hubungi kami sebelum 7 hari setelah laporan di kirim)
This analysis is indicative and base on sample information received and quality of sample supplied. Any decision relating to component repair is entirely discretion of customer
(Analisa ini bersifat indikasi, berdasarkan informasi dari label & sample yg di kirimkan. Jika ada keputusan perbaikan component sepenuhnya kebijakan customer).
**The evaluation & Recommendation made by Equipment Management PT. Trakindo Utama
B19K091413 Page 2 of 2