Ec3551 TLRF

This document provides a summary of a continuous internal assessment test for a transmission lines and RF systems course. The test contains two parts: - Part A contains 10 multiple choice questions worth 2 marks each about topics like transmission line power delivery, standing wave ratio, and line parameters. - Part B contains two long-form questions worth 15 marks each about topics like waveform distortion, transmission line constants, input impedance calculation, and line termination problems. The test aims to assess student understanding of transmission line analysis and high frequency system design.

Uploaded by

Maadhesh
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (2 votes)
538 views

Ec3551 TLRF

This document provides a summary of a continuous internal assessment test for a transmission lines and RF systems course. The test contains two parts: - Part A contains 10 multiple choice questions worth 2 marks each about topics like transmission line power delivery, standing wave ratio, and line parameters. - Part B contains two long-form questions worth 15 marks each about topics like waveform distortion, transmission line constants, input impedance calculation, and line termination problems. The test aims to assess student understanding of transmission line analysis and high frequency system design.

Uploaded by

Maadhesh
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

CONTINUOUS INTERNAL ASSESSMENT – I

Branch: ECE Semester: V Date:08/09/2023(FN) Duration: 90 min


Subject code & Name EC3551-Transmission Lines & RF Systems Max. Marks: 50
Course Outcomes: RBT

CO1 Compute line parameters and various losses of transmission lines [AP]

Calculate the standing wave ratio and input impedance in high


CO2 [AP]
frequency transmission lines

Part – A (10 x 02 = 20 Marks) RBT CO Marks


Answer All Questions
1 When will a transmission line deliver maximum power to the load? U 1 2
2 A 50Ω line is terminated into an infinite line. If it is fed by a 10V.50Ω
AP 1 2
source .Find the reflected and power transmitted into infinite line.
3 Why we need loading in transmission lines? U 1 2

4 Calculate the load reflection coefficient of an open and short


AP 1 2
circuited line.
5 If a line is to have neither frequency nor delay distortion, how do you
relate attenuation constant and velocity of propagation to U 2
1
frequency?
6 What are the assumptions made for the analysis of performance of
U 1 2
the lines at high frequency?
7 For the line of Zero dissipation, what will be the values of attenuation
U 1 2
and propagation constant?
8 Compare the expressions for inductance L of open wire line and
U 2 2
coaxial Line?
9 Distinguish between the nodes and antinodes on a Transmission lines U 2 2

10 Write the expression of voltage and current equation of dissipation


U 2 2
less line?
Part – B (02 x 15 = 30 Marks) RBT CO Marks
Answer All Questions
11(a) Define wave form distortion on a transmission line. Determine the
condition for distortion less transmission line. How can a U 1 (15)
transmission line be made distortion less?
(OR)

11(b) What are the salient aspects of primary constants of two wire
transmission lines? Determine the voltages and current expression U 1 (15)
of two wire transmission lines?

12(a) A generator of 1V 1kHz supplies power to a 100km long line


terminated in Z0 and having the following constants.
R=10.4Ω/km, L=0.00367H/km, G=0.8 X10-6 mho/km,
AP 1 (15)
C=0.00835X10-6 F/km. Calculate Input impedance attenuation
,propagation constant wavelength and phase velocity. Also
Calculate received current, voltage and power.
(OR)

12(b)(i) The constants of transmission lines are R=6Ω/km, L=2.2mH/km,


G=0.25 X10-6 mho/km, C=0.005X10-6F/km. Determine the (8)
characteristics impedance and propagation constant at 1000Hz.

(ii) A 2 meter long transmission lines with characteristic impedance AP 1


of 60+j40Ω are operating at 106 rad/sec has attenuation
constants of 0.921 Np/m and phase shift constant of 0 rad/m. If
(7)
the lines are terminated by a load of 20+j50Ω, determine the
input impedance of this line.