Electrical Specs
Input
Input range 85-132 VAC or 170-264 VAC automati-
cally selected. 220-300 VDC
Frequency 47-63 Hz
Inrush current 38 A max, cold start @ 25°C
Efficiency 75% typical at full load
EMI filter Meets FCC Class B conducted
CISPR 22 Class B conducted
EN55022 Class B conducted
VDE 0878 PT3 Class B conducted
Safety ground leakage
current 0.5 mA @ 50/60 Hz, 264 VAC input
5810 Van Allen Way Astec House, Waterfront Business Park Units 2111-2116, Level 21
Carlsbad, CA 92008 Merry Hill, Dudley Tower1, Metroplaza
Telephone: 760-930-4600 West Midlands, DY5 1LX, UK 223, Hing Fong Road
Facsimile: 760-930-0698 Telephone: 44 (1384) 842-211 Fwai Fong, New Territories
Facsimile: 44 (1384) 843-355 Hong Kong
Telephone: 852-2437-9662
Facsimile: 852-2402-4426
LPQ150 Series
Ordering Information
Model Output Minimum Maximum Load with Maximum Load with Peak Regulation2 Ripple
Number Voltage Load Convection Cooling 30 CFM Forced Air Load1 P/P (PARD)3
LPQ152 5V 2A 15 A 22 A 30 A ±2% 50 mV
12 V .1 A 6A 8A 10 A ±3% 120 mV
-12 V .1 A 2A 2.5 A 3A ±3% 120 mV
±5-25 V 0A 2.5 A 3A 3A ±3% 240 mV, max.
LPQ153 5V 2A 15 A 22 A 30 A ±2% 50 mV
15 V .1 A 4.8 A 6.4 A 8A ±3% 150 mV
-15 V .1 A 1.6 A 2A 2.4 A ±3% 150 mV
±5-25 V 0A 2.5 A 3A 3A ±3% 240 mV, max.
LPQ154 5V 2A 15 A 22 A 30 A ±2% 50 mV
12 V .1 A 6A 8A 10 A ±3% 120 mV
-12 V .1 A 2A 2.5 A 3A ±3% 120 mV
24 V .5 A 3.5 A 4.5 A 5A +10 / -5% 240 mV
1. Peak current lasting <30 seconds with a maximum 10% duty cycle.
2. At 25°C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings.
3. Peak-to-peak with 20 MHz bandwidth and 10 µF in parallel with a 0.1 µF capacitor at rated line voltage and load ranges.
4. 4th output adjustable 5-25 V factory set at 5 V.
5. Minimum loads are required.
Note: -C suffix added to the model number indicates cover option.