11/18/en

19/ 20
FLUE GAS ANALYSIS

Portable Measuring Instruments


PRESSURE
TEMPERATURE
HUMIDITY/MOISTURE
TIGHTNESS TEST
Catalogue

19/ 20
Portable Measuring
Instruments

Technology for environmental protection


Measuring. Controlling. Monitoring.

AFRISO-EURO-INDEX GmbH
Lindenstraße 20
74363 Güglingen
Germany
Phone +49 7135 102-0
Fax +49 7135 102-147
[email protected]
www.afriso.com
Professional measuring systems for
building technology and industrial applications
Suitable measuring systems for any application. AFRISO offers solutions for official
measurements, adjustment, servicing, maintenance and repair work.
The pictograms indicate ideal suitability of the system for your specific application.

HVAC companies, customer service, service technicians

Chimney sweeps

Energy consultants, experts, environmental experts, facility management

Architects, real-estate brokers

Industry: Production processes, servicing

All stock items have part numbers printed in blue.

The catalogue has been presented by:

If you have questions: Please feel free to get in touch with us!
Extensions +49 7135 102-

Technical consulting: -166

Hotline sales: -134


(information on prices/delivery periods)

Service and repairs: -211

Further information on contact persons can be found


at: www.afriso.com/contact
CATALOGUE PORTABLE MEASURING INSTRUMENTS

Portable service instruments


for domestic and industrial technology

From page
AFRISO service instruments
4

From page
Selection guide and overview
8

Flue gas analysis


From page Flue gas analyser BLUELYZER ST, EUROLYZER STx, MULTILYZER STx, dust measuring instrument 1
11 STM 225, infrared/UV gas analyser MCA 5000, portable gas treatment system TMA 65/75

Pressure measurement / From page Pressure measuring instruments S2600 and S4600 ST, leak test sets DPK 60 series, 2
tightness test 29 gas detectors GSP 1 and GSP 3 Flex

Temperature and From page Temperature measuring instruments TM 6, TM 7, TMD 7 und TMD 9, infrared temperature measuring
instruments TM 8-IR,
3
humidity/moisture measurement 45 moisture measuring instrument MFM 22, humidity/air temperature measuring instruments FT series

CAPBs ® sensor module From page Base handle BG 10, sensor modules for: Pressure PS 10-61, P 70 and FP 10, temperature TK 10-50, humidity/­
temperature RH 80, air ­quality AQ 20, gas leak detection GS 10 and CO 30, flow rate measurement FlowTemp®ST,
4
systems/measuring units 55 kits for tightness test, determination of amount of gas leakage, water, heating system check, 4 Pa test

Flow measurement
From page Air velocity and air mass flow meter BlueAir-STx,
measuring instruments for hydraulic balancing HMG 01 and HMG 10,
5
77 flow rate measuring instrument Flowtemp

Inspection and testing equipment


From page Pressure gauge RF 50 PPS for oil burner pumps, test and refill set PNG, vessel filler for
expansion vessels, testers PGA and PGW for pressure tests, universal
6
91 digital pressure gauge DIM 20, level sensor tester GPR 4, anode tester AT1

Flue gas probes, modular probe system, probe plug-ins, condensate filter cartridges, temperature probe,
Accessories and options for the From page clamping cones, probes for air velocity/moisture measuring instruments, connection kits, transport systems, 7
BlueLine series and CAPBs ® 101 printers, soot pumps, memory cards, power supply units, charging cables, accessories for leak test sets,
evaluation software EuroSoft mobile and Eurosoft live app, maintenance contracts, warranty extensions

Appendix
From page AFRISO support centres and service points, service offerings, training, specialised company search,
downloads, information material, information on EN 50379, AFRISO at a glance, General Terms of
8
119 ­Delivery, production sites

Page
Notes on the catalogue
135

3
AFRISO development centre:
SYSTRONIK at the Illmensee site

The perfect instrument for all applications


Measuring and testing – reliably and professionally

Combustion systems must operate optimally. Oil, gas, pellets or log


wood fired systems – AFRISO measuring systems ensure success-
ful measurements. We support you in helping your customers
achieve their goals: the right amount of heat at the right time, low
energy consumption and low emissions.
Our instruments yield high-precision, reproducible measurement
results. You can always rely on us. Our products are future proof
and we have an impeccable reputation as a major innovation leader.
Integration of the maximum number of measuring cells in minimum
space, ergonomic design, smart and effective solutions such as
wireless data transmission via QR codes, data evaluation and pro-
cessing by means of apps for smartphones and tablet PCs or the
latest interface technology Bluetooth® Smart: AFRISO keeps setting
the standards.

4 www.afriso.com
SGERÄT
ES

E
Y
MA

AN
E
IN G E R M

D
eLi
Blu ne
A line of professional measuring systems
Proven and unparalleled

Y
MA

AN
E
IN G E R M

D
Benefit from a comprehensive range of measuring instruments for
all applications – from basic devices for simple tasks all the way to HTML. PDF. QR code. ZIV interface.
all-in-one analysis computers.
Maximum flexibility
Tested measuring instruments according to the in processing of the
­applicable standards and directives
H2-compensated CO measuring cells for official
measurement results
­measurements
All measurement logs of the BlueLine flue gas analysers can
Maximum ease of use due to state-of the-art techno- be archived as HTML files without any additional software and
logy such as TFT colour display, SD memory card and opened with any Web browser. It is also possible to convert
operation via touch pad or display them to QR codes so that
they can be scanned
Easy and fast communication with PCs, tablets, smart- by smartphones and
phones and printers via QR codes or interfaces such as tablets and trans-
Bluetooth® Smart, infrared and USB ferred to manage-
ment software. With
Android and iOS apps for graphical visualisation of the ZIV interface
­measurement results EuroSoftZIV
Automatic device check with sensor test during program (Windows), the
start for precise measurement results measurement data
can be transferred
 agnets at the back of the instruments allow for hands-
M directly to the
free operation German chimney
sweep management
Robust protective housing or sleeve against dirt, impact programs. In addi-
and shock tion, the AFRISO
Comprehensive range of accessories to adapt the "EuroSoft mobile"
­instruments exactly to your requirements app offers numerous
functions for modern
data communication.

www.afriso.com 5
Innovative. Future proof. Simply powerful.

From a simple measuring instrument


to an all-rounder.
You already own an AFRISO BlueLine measuring instrument* via Bluetooth® Smart to all measuring instruments of the AFRISO
and want to use it for the majority of your daily measuring tasks, BlueLine series*. Measurement data can be transmitted directly
for example, tightness test, gas leak detection, flow rate meas- to the AFRISO measuring instruments or, by means of a free
urement or 4 Pa test? No problem with your AFRISO measur- app, to your smartphone or tablet. The measurement logs can
ing instrument. In conjunction with the new AFRISO CAPBs® for be further transmitted from the measuring instrument as a QR
pressure, temperature, gas leak detection, humidity and further code or, with the free iOS or Android app, as an Excel (CSV) file.
applications, the most important tasks of heating system techni-
cians and chimney sweeps can be performed easily and with high
accuracy. The compact CAPBs® can be connected wirelessly

live

See chapter 4 for detailed information


on the available CAPBs®.

6 www.afriso.com
The CAPBs® excel with an unprecedented diversity of meas- device for audible signals is integrated into the handle. The unit
uring possibilities with a single system. Numerous sensor and the measuring instrument or the mobile device are paired
modules CAPBs® sens can be easily plugged into the modu- once; after that a wireless connection is available for immedi-
lar base handle BG 10. The ergonomic handle itself is made ate transmission via Bluetooth® Smart. The AFRISO measuring
of high-quality plastic. It contains the power supply (battery, instrument or the free app for smartphone and tablet provide
optionally rechargeable), a tripod socket, a multi-purpose key numerous pre-installed measurement menus for the CAPBs®.
and a multi-colour LED. The multi-purpose key features custo- They include, for example, tightness test and load test, pressure
misable function assignments. For example, it can be used for loss measurement, gas leak detection, heating system check,
zero calibration regardless of the measuring site. In addition, a flow rate measurement, etc.

The following measuring instruments can be immediately


used with the CAPBs®:
* BLUELYZER ST, EUROLYZER STx, MULTILYZER STe/STx
pressure measuring instrument series S4600 ST and temperature
measuring instrument TMD 9

www.afriso.com 7
The BlueLine measuring instrument series at a glance

Analyzer Series
BLUELYZER ST EUROLYZER STx MULTILYZER STx STM 225
MCA 5000 S2600
O2 • • • •**
CO (up to 6,000 ppm) • •**
CO (up to 10,000 ppm) • • •**
CO2 (calculated) • • • •**
NO •*** •*** •**
NO2 •*** •**
NOX •*** •***
Parameters/measured values

CO (40,000 ppm) •*** •**


SO2 •*** •**
Particulate matter •
Methane
Propane (liquefied gas)
Butane
Lambda • • •
Eta efficiency / eta coefficient • • •
Flue gas loss qA • • •
Temperature • • • •
Pressure • • • •*** •
Dew point • • •
Humidity in %
Volume flow •*** •***
Measurements of filters, ventilation systems, ducts •
Measurements of production facilities, tanks •
Burner servicing (gas, oil, solid fuel systems) • • • • • •
CO ambient measurement • • • •
Servicing of water heaters • • •
Servicing of CHP systems • •
Flue gas measurement • • • •
Pressure measurement • • • • •
Measurement of inlet, flow, static and nozzle pressure • • •
Pressure / vacuum measurement • • • •
Typical applications areas

Differential pressure measurement • • •


Vacuum measurement •
Temperature measurement (flue gas, air, external wall) • • •
Temperature measurement (water)
Temperature measurement (moving objects)
Surface temperature measurement • • •
Differential temperature measurement • • •
Draft / chimney draft measurement • • • •
Ventilation loss measurement
Flue gas loss measurement • • •
Heating system check
4 Pa test
Gas leak detection
Gas concentration measurement
Flow rate measurement (water)
Humidity measurement (material/moisture/climatic conditions in rooms)

Air velocity •*** •***


BlmSchV • •
Approvals

EN 50379-2 • • •
EN 15378
KÜO • •
* See product description on the catalogue page or in the Page 14 Page 16 Page 18 Page 20 Page 22 Page 31
operating instructions.
** Depends on product version.
*** Optional

8 www.afriso.com
Series TM 7/
TMD 9 TM6 TM8-IR MFM 22 FT Series BlueAir-STx GSP Series CAPBs®
S4600 ST TMD 7



• •

• • • • •*** • •*** •
• •

• • •*** •
•*** • •
• • •
• • •
• •

• • • • •

• •
• •
• •
• •
• •
• • • • • •*** •
• • • • •

• • • • •
•** • •
• •



• •
• •

• • •*** •
•*** • •

• • •

Page 32 Page 48 Page 49 Page 50 Page 50 Page 51 Page 53 Page 78 Page 42 Page 55

www.afriso.com 9
EUROLYZER STx

MULTILYZER STx

BLUELYZER ST

Dust measuring
instrument
FLUE GAS ANALYSIS

Portable measuring instruments


BlueLine series for flue gas analysis,
adjustment work and servicing

FLUE GAS MEASUREMENT

Overview flue gas analysers 12


1
Flue gas analyserBLUELYZER ST 14

Flue gas analyserEUROLYZER STx 16

Flue gas analyserMULTILYZER STe 18

DUST MEASUREMENT

Dust measuring instrumentSTM 225 20

INFRARED GAS ANALYSIS

Infrared/UV gas analyserMCA 5000 22

Portable gas treatment systemTMA 65/75 24

11
Flue gas analysis Flue gas measurement

State-of-the-art technology at work for you


All-in-one flue gas analysers for heating systems

Innovative

Many devices with Bluetooth® Smart interface on board:


Power-saving data transmission to PCs, Bluetooth®
printers, to the app EuroSoft mobile and for pairing with
CAPBs® and other measuring instruments.

Universal

All-in-one: Flue gas analysis, (differential) pressure


measurement, (differential) temperature measurement
and, depending on the device, CO room air monitoring,
dust measurement, Pitot measurement (air velocity).

1 Multitasking

Measure, navigate, charge and


evaluate measurement results at
the same time.

Environmentally friendly

Lead-free ECO sensor (O2) with long service life and


optimised calibration phase, short response time,
resistant to biogenous fuels (not BLUELYZER ST).

Proven

Infrared and bluetooth smart interface


for printer.

Ergonomic

Light-weight handheld measuring instruments,


ergonomic design with robust protective sleeve and
integrated magnets.

Flexible

USB interface for charging.

12 www.afriso.com
Flue gas measurement Flue gas analysis

Intuitive

Intuitive operation via touch pad for scrolling, large TFT


colour display, well-structured step by step measurement
programs.

Reliable

Fully automatic device check during program start.

Smart

Optional data logger function (1-999 seconds, interval freely selectable)


for long-term measurement or diagnostics. Data is stored in XML format for
flexible further processing with standard software applications such as
MS Excel.

1
Perseverant
EuroSoft
mobile app Powerful lithium-ion battery for up to
12 hours of operation.

Mobile

Measurement logs as QR codes for smart-


phones, tablets or management software.

Compatible

Suitable for all AFRISO flue gas probes


and type K temperature probes.

Independent

MicroSD card for system-independent storage


of measurement logs (HTML format) and fast
software updates by user.

No hassle

5 / 7 years full warranty (sensors covered)


in connection with a service contract.

www.afriso.com 13
Flue gas analysis Flue gas measurement

FLUE GAS ANALYSER

BLUELYZER ST

The world's smallest, fully-featured HVAC all-rounder


with TFT colour display

Flue gas analysis, pressure measurement (draft) and


(differential) temperature measurement with a single
instrument

CO ambient measurement with two freely adjustable


alarm thresholds
1
Fully-fledged temperature measurement program,
Picture shows original size

differential temperatures (e.g. flow/return) can also be


determined

Hold function: Display shows the measured value for


a given period of time while the measurement keeps
running in the background

Measurement programs and measured values can be


freely edited

Display reverse function: TFT display can be rotated by


180° for easy reading and excellent working conditions
at the point of measurement

Zoom mode for entire display, "Single-value display"

EuroSoft Memory function with up to 100 measurement logs


mobile app
CAPBs® enabled

Application Ideal for HVAC professionals for accurate adjustments or inspec-


tions, on par level with official flue gas analysers. BLUELYZER ST is
suitable for flue gas analysis, pressure measurement and (differen-
tial) temperature measurement. It is the universal, handheld meas-
uring instrument of choice for measuring small and medium-sized
oil and gas fired heating systems according to the 1st German
Federal Immission Act (BImSchV) and for CO concentration checks
at gas fired systems.

14 www.afriso.com
Flue gas measurement Flue gas analysis

Top Bottom
1 8

3 4 5 6

1 Gas inlet 5 Infrared printer interface


2 Pressure measurement (draft) 6 Signal unit (speaker)
3 
Temperature connection, e.g. for ambient air temperature 7 MicroSD card slot
or combustion air temperature 8 USB connection for power supply unit/charger
4 Temperature connection, e.g. for flue gas temperature

Technical Measuring ranges (measured values) Dimensions


specifications W x H x D 66 x 143 x 37 mm
Flue gas temperature/differential
temperature Display
0/1,000 °C TFT colour display 2.8"
W x H: 45 x 60 mm
Air temperature/combustion
air temperature Connections 1
-20/+200 °C Draft/pressure: Ø 7 mm
Gas: Ø 8 mm
Draft/pressure
Temperature: Type K
40 hPa
Supply voltage
O2
Via lithium-ion battery (3.6 V/1,800 mAh)
0/21 % by volume
or power supply unit (mini USB)
CO
Hours of operation (Eco mode)
0/6,000 ppm (max.)
12 hours
Indication (calculated values)
Data memory
CO2, CO undiluted (air-free), lambda, dew point,
microSD card, max. 16 GB
eta efficiency, flue gas loss qA,
CO mg/m3 (natural gas), CO mg/kWh (fuel oil) Interfaces
Infrared, Bluetooth® Smart, QR code generator,
Operating temperature range
microSD card slot
Ambient: 5/40 °C
Storage: -20/+50 °C Approvals
EN 50379-2 for O2/CO2, TA, TG, pressure
Weight (housing)
EN 50379-3 for CO
Approx. 275 g
VDI 4206 (sheet 1)

i
Calibration report, protective sleeve with

5 x Teflon membrane, condensate filter

Please enquire for other


240 mm with draft, without KFP 2P
magnets for device, power supply unit
NTE 5 mini USB-A, charging cable

device versions.
Flue gas probe compact AKS-K
MicroSD card with USB 2.0 SD

See chapter 7 for options


and accessories.
cartridge KFP 2P, case
USB-A to mini USB

Ambient air probe


(Diff.) temperature

Bluetooth® Smart
5 x particle filter,
Draft/pressure

BLUELYZER ST
TFB-UL 50-1
card reader

Set
CO
O2

DG: H, PG: 4 Part no. Price €


BLUELYZER ST Set • • • • • • • • • P04438116

www.afriso.com 15
Flue gas analysis Flue gas measurement

FLUE GAS ANALYSER

EUROLYZER STx

All-in-one: Flue gas analysis, (differential) pressure meas-


urement, (differential) temperature measurement, Pitot
measurement

Ready for the future: Pairing with the AFRISO CAPBs®


measuring units

ECO sensor: Lead-free O2 sensor with long service life


and optimised calibration phase, short response time,
1 resistant to biogenous fuels

H2-compensated CO cell
(measuring range up to 10,000 ppm)

CO ambient measurement


Picture shows original size

NO cell can be retrofitted

qA mean value measurement as per


1st German Federal Immission Act BlmSchV

Measurement logs as QR code, database memory,


customer data management

CAPBs® enabled

5 years warranty on O2 measuring cell

7 years full warranty in connection with


a service contract

EuroSoft
mobile app

Application Universal application for measuring small and medium-sized oil,


gas and pellets fired heating systems according to the 1st German
Federal Immission Act (qA mean value measurement) and for CO
concentration safety checks at gas fired systems.
EUROLYZER STx is the analyser of choice for measurements of
bivalent, modulating CHP systems. Ideal for measurements at
heating systems with a high proportion of biofuels.

16 www.afriso.com
Flue gas measurement Flue gas analysis

Top Bottom
8

1
7

2 3 5 6
1 USB connection for power supply unit/charger 6 Pressure/differential pressure measurement (draft)

2 Infrared printer interface Temperature connection, e.g. for ambient air
7 
3 MicroSD card slot ­temperature or combustion air temperature
4 Sounder (speaker) 8 Temperature connection, e.g. for flue
5 Gas inlet gas temperature

Technical Measuring ranges (measured values) Weight (housing)


specifications Approx. 500 g
Flue gas temperature/differential
temperature Dimensions
0/1,000 °C W x H x D 65 x 215 x 45 mm
Air temperature/combustion Display
air temperature TFT colour display
-20/+200 °C W x H: 45 x 60 mm
Draft Connections 1
50 hPa Draft/pressure: Ø 7 mm
Gas: Ø 8 mm
Differential pressure
Temperature: Type K
150 hPa
Supply voltage
O2
Lithium-ion battery (3.6 V/2,300 mAh)
0/21 % by volume
or power supply unit (mini USB)
COH2
Hours of operation (Eco mode)
0/9,999 ppm (max.)
14 hours
NO
Data memory
0/2,000 ppm
microSD card (max. 16 GB)
Indication (calculated values)
Interfaces
CO2, CO undiluted (air-free), lambda, dew point,
Infrared, Bluetooth® Smart,
eta efficiency, flue gas losses qA,
QR code generator, microSD card slot
CO mg/m3 (natural gas), CO mg/kWh (fuel oil)
Approvals
Operating temperature range
As per BlmSchV, KÜO (TÜV ByRgG 190),
Ambient: 5/40 °C
EN 50379-2, EN 15378
Storage: -20/+50 °C

i
magnets for device, power supply unit NTE 5
Differential pressure, connection kit ASS-DP

USB-A, charging cable USB-A to mini USB,

microSD card with USB 2.0 SD card reader

Base handle AWS-B, 2.4 m, draft, for inter-


membrane, covers for measurement holes

Please enquire for other


Interchangeable probe AWS-S, 300 mm
Calibration report, protective sleeve with

device versions.
See chapter 7 for options
O2, COH2 (differential) temperature

and accessories.
Ambient air probe TFB-UL 50-1
5 x Infiltec fine filter, 5 x Teflon

changeable probes with KFP

Bluetooth® Smart
(10 pieces), case
Draft/pressure

EUROLYZER STx
Sets
NO

DG: H, PG: 4 Part no. Price €


EUROLYZER STx Set 1 • • • • • • • • • P04629210
EUROLYZER STx Set 2 • • • • • • • • • • P04630210

www.afriso.com 17
Flue gas analysis Flue gas measurement

FLUE GAS ANALYSER

MULTILYZER STx

All-in-one: Flue gas analysis, (differential) pressure


measurement, (differential) temperature measurement,
dust measurement, Pitot measurement (in conjunction
with STM 225)

ECO sensor: Lead-free O2 sensor with long service life


and optimised calibration phase, short response time,
resistant to biogenous fuels
1 Sensor equipment with a combination of up to six
measuring cells: O2, COH2, NO, SO2, NO2 and CO40,000

CO room air monitoring

qA mean value measurement as per


1st German Federal Immission Act BlmSchV
Picture shows original size

Measuring is possible with two active display levels

Measurement logs as QR code, database memory,


customer data management

5 years warranty on O2/CO measuring cell

7 years full warranty in connection with a service contract

CAPBs® enabled

EuroSoft
mobile app

Application Flue gas analyser for measuring small and medium-sized oil, gas
and pellets fired heating systems according to the German Federal
Immission Act and for CO concentration safety checks at gas fired
systems. Ideal for servicing solid fuel systems (for example, coal or
wood fired systems with temporary CO peaks) or bivalent, modulat-
ing combined heating and power plants. If used within the frame-
work of dust measurements, MULTILYZER STx determines the flue
gas value and serves as the central controller for the dust measur-
ing instrument STM 225.

18 www.afriso.com
Flue gas measurement Flue gas analysis

Bottom Top 8

3 4 5 6 7

1  emperature connection e.g. for ambient air


T 5 Infrared printer interface
temperature or combustion air temperature 6 Signal unit (speaker)
2 Temperature connection e.g. for flue gas temperature 7 MicroSD card slot
3 Gas inlet 8 Mini USB connection for power supply unit/charger
Gas inlet
4 Pressure/differential pressure measurement

Technical Measuring ranges (measured values) Operating temperature range


specifications Operation: 5/40 °C
Flue gas temperature/differential
Storage: -20/+50 °C
temperature
0/1,150 °C Weight
Approx. 685 g
Air temperature/combustion
air temperature Dimensions
-20/+200 °C W x H x D 90 x 220 x 53 mm
Draft Display
70 hPa TFT colour display 3.5"
1
W x H: 53 x 71 mm
Differential pressure
150 hPa Connections
Draft/pressure: Ø 7 mm
O2 measurement
Gas: Ø 8 mm
0/21 % by volume
Temperature: Type K
COH2 measurement
Supply voltage
0/10,000 ppm
Lithium-ion battery (3.6 V/2,900 mAh)
CO measurement or power supply unit (mini USB)
0/40,000 ppm
Hours of operation
NO measurement Max. 12 hours
0/5,000 ppm
Data memory
NO2 measurement microSD card (max. 32 GB)
0/500 ppm
Data logger
SO2 measurement 1-999 seconds, interval freely selectable
0/5,000 ppm
Interfaces
Indication (calculated values) Infrared, Bluetooth® Smart,
CO2, CO undiluted (air-free), lambda, eta QR code generator, microSD card slot
efficiency, flue gas losses qA, dew point,
temperature difference Approvals
1. BlmSchV, KÜO (TÜV ByRgG 301), EN 50379-2

i
MicroSD card with USB 2.0 SD
USB-A to mini USB, 5 x Infiltec fine
power supply unit, charging cable
power supply unit NTE 5 USB-A,

filter, 5x Teflon membrane, case


sleeve for device with magnets,

Base handle AWS-B, 2.4 m,

Please enquire for other


Draft, differential pressure,

Module particulate matter


Calibration report, protective

draft, for interchangeable

device versions.
connection kit ASS-DP

See chapter 7 for options


and accessories.
Ambient air probe

Bluetooth® Smart
probes with KFP

measurement
TFB-UL 50-1
card reader

MULTILYZER STx
O2 , COH2

CO 40,000

Sets
NO

DG: H, PG: 4 Part no. Price €


MULTILYZER STx set 1 • • • • • • • P04729210
MULTILYZER STx set 2 • • • • • • • • P04730210
MULTILYZER STx set 3 • • • • • • • • P04741210
MULTILYZER STx set 4 • • • • • • • • • P04748210
MULTILYZER STx set 5 • • • • • • • • • P04741217

www.afriso.com 19
Flue gas analysis Dust measurement

DUST MEASURING
INSTRUMENT

STM 225

Optical measuring principle for fast, accurate


measurement results and real time diagnostics

Reliable measurement results, not influenced


by interference (e.g. shocks)

Intuitive operation via menu-guided


measuring sequences
1 Operation, flue gas analysis and data output via the
­optional flue gas analysis MULTILYZER STe/STx as
­central controller

Visualisation via 5.7" colour touch display

Permanent indication of the current measured value

Output of the mass concentration of dust as a


15 minute mean value

Qualification-tested also for 30-minutes mean value


measurement

Short setup time due to fast


heat-up and calibration phase

Bluetooth® connectivity for flue gas analyser


MULTILYZER STe/STx

Compact, robust measuring system

Application Dust measuring instrument specially designed for mobile use at


solid-fuel systems such as pellets or wood fired systems for deter-
mining the mass concentration of particles/dust and for monitoring
the limit values for particulate matter. Approved for stages 1 and 2,
including limit value monitoring 150 mg/m3 for old systems as well
as 30-minutes mean value measurement of single room combus-
tion systems. The sampling probe can also be used for tightness
tests of the entire gas path. Ideal for chimney sweeps, heating
system engineers and service technicians for performing required
particulate matter measurements, e.g. as per 1st German Federal
Immission Act.

20 www.afriso.com
Dust measurement Flue gas analysis

Back

1 6

2
8
1 Gas inlet, connection

2 Condensate collector
9 3 Particle filter for pump
3 4 Gas outlet
5 Condensate outlet
6 Connection socket sampling line
7 Bracket for sampling line
4
8 USB interface for manufacturer
servicing (e.g. software updates)
9 RS 232 interface for software

Technical Measuring range Degree of protection


specifications 0/300 mg/m³ dust IP 40
Measured values (via Multilyzer STx) Display 1
O2: 0/21 % by volume Colour touch display, 5.7" (14.5 cm)
COH2: 0/4,000 ppm
Supply voltage
CO: 0/40,000 ppm
AC 230 V, 50 Hz
Measuring resolution
Power
0.1 mg/m³
Approx. 230 VA (with heated line)
Operating temperature range
Interfaces
Ambient: 5/40 °C
Bluetooth®, USB, RS 232
Storage: -20/+50 °C
Approvals
Housing
Certified suitability for stages 1 + 2, including
W x H x D: 205 x 275 x 350 mm
150 mg/m3, 30-minutes mean value measurement
Weight
Transport bag
Approx. 7.6 kg
Light-weight and heavy-duty
with carrying strap and handle

i
nection line, condensate filter cartridge

calibration report, Bluetooth® interface,

5 cleaning swabs and cleaning cloths,


Sampling probe with heated line, con-
point filter, mains cable, transport bag

See chapter 7 for options


­particulate matter measurement, with

device, power supply unit, Infiltec fine


STM 225 with calibration report, zero

and accessories.
protective sleeve with magnets for

­filter (5 pieces), Teflon membrane

Ambient air probe TFB-UL 50-1


KFP, Infiltec fine filter (5 pieces)

MULTILYZER STx with module

1 cleaning brush
Cleaning kit:

STM 225
(5 pieces)

Sets

DG: H, PG: 4 Part no. Price €


Dust measuring instrument
STM 225 • • • 570200
Set 1
Dust measuring instrument
STM 225 • • • • • 570228
Set 2

www.afriso.com 21
Flue gas analysis Infrared gas analysis

IR/UV GAS ANALYSER

MCA 5000

System solution with ready-to-use analysis system in


robust, compact case

Reliable measurements with proven measurement


­technology adapted to the applications

Almost any combination of analysis modules due to


­modular design
1 Highly accurate, selective SO2, NO and NO2 measure-
ment with UV modules

Highly selective NDIR modules for continuous measure-


ment of almost any gas component (CO, NO, SO2, CO2,
HC, etc.) absorbing in the infrared spectrum

Accurate oxygen measurement by means of paramagne-


tic measuring principle

Determination of O2, CO, NO, NO2, SO2, NH3, etc. by


­means of electro-chemical cells

Automatic adjustment with test gases

Efficient end flexible communication via 0(4)–20 mA,


Ethernet, CAN bus or Profibus-DP interfaces

State of the art data transmission via LAN, WLAN,


­Bluetooth or USB

Integrated data logger

Easy service: Simple maintenance and repair because


individual components or modules can be replaced

Application MCA 5000 is a portable extractive gas analyser for measurement of


more than 60 components. It excels with a consistently modular
design. Depending on the application, up to 10 analysis modules
i (electro-chemical, paramagnetic, NDIR and/or UV) can be installed
in a case, together with a control unit and a display unit. The
The gas analyser is avail­
cost-effective system configuration also allows for the integration of
able with or without gas
additional components such as pressure, temperature, humidity or
treatment system.
a gas treatment system.

22 www.afriso.com
Infrared gas analysis Flue gas analysis

Technical data
Measuring ranges
Gas type Type Min. measuring range Max. measuring range Interval
O2 ec 2 % by volume 25 % by volume continuous
PM 1 % by volume 100 % by volume continuous
CO ec 100 ppm 2,000 ppm discontinuous
IR 1,000 ppm 50 % by volume continuous
CO2 IR 500 ppm 100 % by volume continuous
NO ec 100 ppm 1,000 ppm discontinuous
IR 2,000 ppm 1 % by volume continuous
NO2 ec 50 ppm 1,000 ppm discontinuous
UV 100 ppm 5,000 ppm continuous

i SO2 ec 50 ppm 200 ppm discontinuous


Enquire for other gases/ UV 100 ppm 50 % by volume continuous
components. CH4 IR 5,000 ppm 100 % by volume continuous

Indication (calculated values) Interfaces


CO undiluted (air-free), lambda, dew point, flue 0/4–20 mA
gas loss Ethernet
Profibus-DP
Gas types
LAN
Max. 8 gases
USB
Flow rate
Options
30/60 l/h ■■ Electro-chemical sensors 1
■■ 2 temperature inputs
Operating temperature range
■■ Interfaces: Bluetooth, WLAN, CAN bus
Operation: 10/40 °C
■■ Liquid alarm sensor (LA+)

Degree of protection ■■ Flow monitoring (FA–)

IP 40 ■■ Gas cooler: Approx. 5–8 °C Tp

■■ Heated gas line up to 180 °C (max. 5 m)


Display
■■ Heated probe, self-controlling
Touch display 7” (17.78 cm)
Supply voltage
AC 230 V or AC 115 V

PG: 4 Part no. Price €


IR gas analyser MCA 5000, O2 , CO, CO2 69504 On request
IR gas analyser MCA 5000, O2 , CO, NO 69505 On request
IR/UV gas analyser MCA 5000, O2 , CO, CO2 , SO2 69507 On request
IR gas analyser MCA 5000, O2 , CO, CO2 , NO 69508 On request
IR/UV gas analyser MCA 5000, O2 , CO, CO2 , NO, SO2 69509 On request

www.afriso.com 23
Flue gas analysis Gas treatment

GAS TREATMENT

TMA 65

Compact version of a fully-featured gas treatment system


in a robust case

Can be used as a portable or stationary gas treatment


system

Adjustable output dew point and alarm thresholds

Gas cooler with 80 kJ/h nominal capacity


1
Optional: Humidity probe with bypass valve, rotameter

With connection for 1 heated line (no control or


­controlled)

Ready to operate after approx 10 minutes

Application Portable gas treatment system for performing accurate gas analy-
ses at changing sites with different analysis devices. Especially for
long-term or continuous measurements and measurements involv-
ing pollution and/or condensate. Decisive for precise and reproduc-
ible measurement results.

The base version of TMA 65 consists of a gas cooler with conden-


sate pump and filter. Irrespective of the ambient temperature, the
gas cooler cools the gas down to the adjusted dew point. A safety
circuit only releases the gas pump when the cooler has reached its
point of operation. The gas cooler and the filter element are adapt-
ed to condition corrosive gases. With the optional gas pump with
bypass valve and the flow meters, it is possible to supply up to two
gas outlets individually. The function "cold start" enables fast use
even at a storage temperature of less than 5 °C.

24 www.afriso.com
Gas treatment Flue gas analysis

Gas flow chart


5
6
1 3 4

7
2

1 Gas cooler 5 Gas pump with bypass (option)


2 Condensate pump 6 Rotameter 1 (option)
3 Humidity probe (option) 7 Rotameter 2 (option)
4 Filter element

Technical data Operating temperature range Supply voltage


Ambient: 5/50 °C AC 230, 50/60 Hz
Gas outlet dew point: Current input
Adjustable: 2/20 °C Max. 250 VA (without heated gas line)
Factory setting: 5 °C
Measuring system (wetted parts)
Alarm thresholds PVDF, glass, stainless steel, PTFE, Norprene, 1
Adjustable, –3/–1 K and 1/7 K Viton, epoxy, sintered PTFE
(around dew point)
Housing
Gas flow W x H x D: Approx. 360 x 460 x 260 mm
Approx. 50/280 l/h Connection length
low temperature
Operating pressure
connector: 2.5 m
0.2/2 bar absolute
Weight: Approx. 13.5 kg (base device)
Static dew point Degree of protection: IP 20
0.1 K
Options
in entire range: ±1.5 K ■■ Other connections for gas inlet/gas outlet
■■ Supply voltage AC 115 V, 50/60 Hz
Input dew point
■■ Gas pump with bypass valve
Max. 70 °C
■■ Humidity probe

Gas inlet temperature ■■ Rotameter

Max. 140 °C
Nominal cooling capacity (at 25 °C): 80 kJ/h

PG: 4 Part no. Price €


Portable gas treatment system TMA 65 69483
Options
Gas pump with bypass valve 69484
Humidity probe 69494
Rotameter 69489

www.afriso.com 25
Flue gas analysis Gas treatment

GAS TREATMENT
MULTILYZER STx not included in scope of delivery

TMA 75

Compact version of a fully-featured gas treatment system


in a robust case

Can be used as a portable or stationary gas treatment


system

Adjustable output dew point

With status alarm (changeover contact)


1
Ready for operation after approx. 20 min

Heated, self-controlling gas line and gas sampling probe


can be connected

Application Portable gas treatment system for performing accurate gas analy-
ses at changing sites with different analysis devices. Especially for
long-term or continuous measurements and measurements involv-
ing pollution and/or condensate. Decisive for precise and reproduc-
ible measurement results.

The base version of TMA 75 consists of a gas cooler with conden-


sate pump and a 2 µm fine particulate filter. Irrespective of the
ambient temperature, the gas cooler cools the gas down to the
adjusted dew point.

Lightweight, compact gas treatment unit, ideal for portable flue gas
analysers.

26 www.afriso.com
Gas treatment Flue gas analysis

Technical data Operating temperature range Connections


Ambient: 5/40 °C Measured gas/condensate:
Compression fitting Ø 4/6 mm
Gas outlet dew point:
Adjustable: 2/20 °C Supply voltage
Factory setting: 5 °C AC 230 V, 60 Hz
Status alarm Current input
Changeover contact Max. 150 VA
Gas flow Contact rating
75 l/h, without pre-separation 1 VA/24 VDC; 0.5 VA/120 VAC
Operating pressure Measuring system (wetted parts)
Max 1 bar PA, PTFE, Viton, Duran glass, stainless steel 316
Pressure loss Housing
< 1 mbar at 60 l/h Aluminium
W x H x D: 360 x 415 x 220 mm
Flow meter
Degree of protection: IP 20
7/70 l/h air, 20 °C, 1 bar absolute
Options
Pumps ■■ Supply voltage AC 115 V, 60 Hz
Measured gas: Vmax. = 180 l/h
Condensate: SR25, Vmax. = 1 ml/min
Input dew point
40 °C, without pre-separation
Gas inlet temperature
Max. 120 °C 1

PG: 4 Part no. Price €


Portable gas treatment system TMA 75 69503 On request

www.afriso.com 27
Series S4600 ST

Series S2600

Leak test sets DPK series

Gas detectors
PRESSURE MEASUREMENT

Precision measuring instruments


and complete sets for checks,
tightness tests and leak location

PRESSURE MEASURING INSTRUMENTS

Product highlight pressure measuring instruments: Series S4600 ST 30

Pressure measuring instrumentS2600 31

Pressure measuring instrumentS4600 ST 32 2

TIGHTNESS TEST / LEAK LOCATION

Selection table leak test sets 34

Test procedures at gas, oil, solar and water installations 35

Leak test setDPK 54 111

Leak test setDPK 60-5 37

Leak test setDPK 60-6 ST, CAPBs® enabled 38

Leak test setDPK 60-7 ST, CAPBs® enabled 40

Gas detectorsGSP 1 and GSP 3 Flex 42

29
Pressure measurement Pressure measuring instruments

The compact pressure measuring instrument


Product highlight: Series S4600 ST

All-in-one

Measurement of pressure, vacuum and differ-


ential pressure and, depending on the version,
Innovative
Pitot measurement (air velocity).
Bluetooth® Smart interface on board: Power-
saving data transmission to AFRISO CAPBs® or
Proven
to the AFRISO apps.
Infrared interface for IR printer.

Ergonomic Smart
Extremely compact and light-weight Optional data logger function (1-999
design for convenient handling, includ- seconds, interval freely selectable) for
ing hands-free operation thanks to the long-term measurement or diagnostics.
magnet integrated in the protective Data is stored in XML format for flexible
housing. further processing with standard soft-
ware applications such as MS Excel.

2
Full coverage Comprehensive
Covers the entire range of measuring Six (differential) pressure
requirements: From measuring instrument measuring ranges
for ultra-low pressure (20 mbar) to version
for very high pressure (18 bar).

Independent

microSD card for system-independent


storage of measurement logs (HTML
Perseverant
format) and fast software updates.
Powerful lithium-ion battery for
up to 38 hours of operation.

Energy-saving

The ECO mode for energy-saving

Mobile operation ensures long battery life.

Measurement logs as QR codes for EuroSoft


smartphones, tablets or management mobile app
Reliable
software
Fully automatic device check,
manual and automatic zero
calibration during program start.

Accurate

Highly accurate measurements due to integrated Striking


barometric pressure sensor and temperature
More convenience: The large TFT colour display
compensation. Measured values are displayed
(W x H: 45 x 60 mm) shows four measured values
in nine units: mbar, Pa, hPa, kPa, mmWC, mmHg,
simultaneously and lets you clearly see the results,
inHg, psi, bar.
even in dark rooms.

30 www.afriso.com
Pressure measuring instruments Pressure measurement

PRESSURE MEASURING
INSTRUMENT

S2600

Four (differential) pressure measuring ranges

Measured values displayed in 8 units:


mbar, Pa, hPa, kPa, mmHg, inHg, psi, bar
Also
available Hold function for short-term freezing of measured value
as
Fully automatic device check, manual and automatic
CAPBs® zero calibration during program start

Hose connection via 8 mm plug in connection or


3 mm Festo clamp connection

Application For measuring pressure, vacuum and differential pressure. For non-corrosive gaseous, dry media. 2
Ideal for industrial, medical and air conditioning technology applications.
Other typical application areas: Measurement of chimney draft, measurement of inlet pressure, flow
pressure and nozzle pressure, pressure loss in flowing gases, filter inspection, ventilation systems or
ducts, production and extraction facilities, vacuum measurement (laboratory), check of the connection
pressure (natural gas supply pipes), burner pressure check, inspection of tanks for liquids
(inlet and outlet pressure).

Technical Measuring Max. over- Accuracy


specifications Model Resolution (mbar)
range (mbar) pressure (bar) (% of measured value)
0.01 (< 19.99)
S2601 (FZM 30) -20/+150 1.35 1.0 ± 1 digit (< 130.0 mbar)
or 0.1 (> 20)
0.1 (< 199.9)
S2610 (DMG 15) -50/+1,000 3 1.0 ± 1 digit (< 1,000 mbar)
or 1.0 (> 200)
0.1 (< 199.9)
S2650-F (DMG 25) -100/+5,000 10 1.0 ± 1 digit (< 5,000 mbar)
or 1.0 (> 200)
0.1 (< 199.9)
S2680-F (DMG 35) -100/+8,000 10.5 1.0 ± 1 digit (< 8,000 mbar)
or 1.0 (> 200)

Operating temperature range Hose connection


Ambient: 0/40 °C S2601, S2610: Ø 8 mm
Storage: -20/+50 °C S2650-F, S2680-F: Ø 3 mm (Festo)
Hours of operation Supply voltage
Max. 100 hours 2 x 1.5 V Mignon (AA) batteries
Weight (housing) Approvals
Approx. 250 g 1st German Federal Immission Act (1. BlmSchV),
EN 50379-2
Dimensions
i W x H x D 66 x 143 x 37 mm Scope of delivery
See chapter 7 for options Measuring instrument with batteries, calibration
Display
and accessories. report, protective sleeve with magnet
LCD, transflective W x H: 46 x 48 mm

DG: H, PG: 4 Part no. Price €


Draft measuring instrument S2601 (FZM 30) 569680
Pressure measuring instrument S2610 (DMG 15) 569681
Pressure measuring instrument Druckmessgerät S2650-F (DMG 25) 569682
Pressure measuring instrument Druckmessgerät S2680-F (DMG 35) 569684

www.afriso.com 31
Pressure measurement Pressure measuring instruments

PRESSURE MEASURING
INSTRUMENT

S4600 ST

For measuring pressure, vacuum and differential


pressure

Six (differential) pressure measuring ranges from


measuring instrument for ultra-low pressure (20 mbar)
to version for very high pressure (18 bar)

Barometric pressure sensor and temperature


compensation for highly accurate measured value

Large TFT colour display (W x H: 45 x 60 mm) for


simultaneous display of 4 measured values
2
Measured values displayed in 9 units:
mbar, Pa, hPa, kPa, mmWC, mmHg, inWC, psi, bar

Fully automatic device check, manual and automatic


zero calibration during program start

microSD card for system-independent storage of meas-


urement logs (HTML format) and fast software updates

Optional data logger function for long-term measurement


or diagnostics (data in XML format)

Pitot measurement (air velocity) for measuring range


up to 20 mbar or 150 mbar
EuroSoft
mobile app

Application For measuring pressure, vacuum and differential pressure. For


non-corrosive gaseous, dry media. Ideal for industrial, medical and
Also air conditioning technology applications. Other typical application
areas: Measurement of chimney draft, measurement of inlet pres-
available
as sure, flow pressure and nozzle pressure, pressure loss in flowing
gases, filter inspection, ventilation systems or ducts, production and
CAPBs® extraction facilities, vacuum measurement (laboratory), check of the
connection pressure (natural gas supply pipes), burner pressure
check, inspection of tanks for liquids (inlet and outlet pressure).
Minimum and maximum values can be set before the measure-
ment; if these values are reached, visual or audible alarms are trig-
gered. The free Android app "EuroSoft mobile" allows for transfer of
measurement results to smartphones and tablets via QR code and
for the visualisation of such results. Measurement logs can also be
sent via e-mail.

32 www.afriso.com
Pressure measuring instruments Pressure measurement

Top Bottom
5

1 2 3

1 Pressure/differential pressure measurement


 4 MicroSD card slot
2 Infrared printer interface 5 USB connection for power supply unit/charger
3 Signal unit (speaker)

Technical Measuring Max. over- Accuracy


specifications Pitot
Model range pressure Resolution (mbar) (% of measured
(m/s)
(mbar) (bar) value)
0.01 (< 99.99) / 0.1 (> 100) 0.5 ± 1 digit
S4601 ST ± 150 2 – 50 1.35
Pitot (m/s): 0.1 Pitot: ±0.8 m/s
0.001 0.5 ± 1 digit
S4602 ST ± 20 0.5 – 50 0.25
Pitot (m/s): 0.1 Pitot: ±0.3 m/s
S4610 ST ± 1,000 – 16 0.1 (< 999.9) / 1.0 (> 1,000) 0.5 ± 1 digit

S4650 ST (-F) ± 5,000 – 16 0.1 (< 999.9) / 1.0 (> 1,000) 0.5 ± 1 digit

S4680 ST (-F) ± 8,000 – 16 0.1 (< 999.9) / 1.0 (> 1,000) 0.5 ± 1 digit
2
S4699 ST-F ± 18,000 – 28 1 0.5 ± 1 digit

Operating temperature range Supply voltage


Ambient: 0/40 °C Lithium-ion battery (3.6 V/1,800 mAh)
Storage: -20/+50 °C or power supply unit (mini USB)

Hours of operation Data memory


Max. 38 hours microSD card, max. 16 GB

Weight Data logger


Approx. 250 g 1–999 seconds, interval freely selectable
Interfaces
Dimensions
Infrared, Bluetooth® Smart, QR code generator,
W x H x D 66 x 143 x 37 mm
microSD card slot
Display
TFT colour display, 2.8" Approvals
W x H: 45 x 60 mm EN 50379-2 (except for S4699 ST)

Hose connection Scope of delivery


■■ Measuring instrument with power supply
S4601 ST, S4602 ST, S4610 ST
S4650 ST, S4680 ST: Ø 8 mm unit and data cable
■■ Calibration report
S4650 ST-F, S4680 ST-F,
■■ microSD card

i S4699 ST-F: Ø 3 mm (Festo)


■■ Protective sleeve with magnet

See chapter 7 for options


and accessories.

DG: H, PG: 4 Part no. Price €


Pressure measuring instrument S4601 ST (150 mbar) 571301
Pressure measuring instrument S4602 ST (20 mbar) 571300
Pressure measuring instrument S4610 ST (1,000 mbar) 571302
Pressure measuring instrument S4650 ST (5,000 mbar) 571303
Pressure measuring instrument S4650 ST-F (5,000 mbar), with Festo connection ø 3 mm 571304
Pressure measuring instrument S4680 ST (8,000 mbar) 571305
Pressure measuring instrument S4680 ST-F (8,000 mbar), with Festo connection ø 3 mm 571306
Pressure measuring instrument S4699 ST-F (18,000 mbar), with Festo connection ø 3 mm 571307

www.afriso.com 33
Pressure measurement Tightness test

DPK series for professional pressure tests

CAPBs®- CAPBs®-
Set Set
DPK DPK DPK DPK 60-7
DPK 54 DPK 60-5 60-6 ST 60-6 sens 60-7 sens ST
Load test as per TRGI • • • •
Tightness test as per TRGI • • • •
Evaluation of serviceability/
determination of amount of gas Gas • •
leakage TRGI
Tightness test as per TRF 86 • • • •
Pressure measurement • • • • •
Strength test as per ZVSHK • • • •*
Drinking
Tightness test as per ZVSHK • • • •
water
Pressure measurement • • • • •
Tightness test as per EN 1610 Waste • • • •*
2 Pressure measurement water • • • •*
Heating
Pressure measurement • • • •
systems
0/200 mbar • • • •
-0.5/+1.5 bar • • •
-1/+5 bar Pressure • • •*
0/2 bar ranges • • • • • •*
0/3 bar • • • •*
0/20 bar •* •*
Air • • • • • •
Inert gas • • • • • •
Water •* •*
Mechanical determination of Test • •
measured values medium
Digital determination of measured
• • • •
values
Freely adjustable measurement
• • • •
times
IR interface • •
Bluetooth® Smart interface • • • •
MicroSD/SDHC card • •
Data logger function •** •*** •*** •**
Specifications
Barometric pressure sensor • • •
Hose coupling system • • • • •
Connection temperature sensor

(type K)
Connection pressure sensor •
* Possible with external pressure sensor (optional).
** Optional. Page 111 Page 37 Page 38 Page 70 Page 71 Page 40
*** via mobile App EuroSoft live.

34 www.afriso.com
Tightness test Pressure measurement

Test procedures at gas, oil,


solar and water installations

All gas, oil, solar and water pipe installations are subject to a man- certifies the tightness of the system or parts of the system in the
datory pressure test after installation. The specialised company test report and confirms proper installation with a signature.

2
Test of heating systems Test of oil pipes
The pressure test must be performed as per TRÖL
(German Technical Rules for Oil Systems); it can be extended
Tightness test by a tightness test. Requirements concerning the measuring
instruments:
Time of test New installations prior to closing of wall ■■ Accuracy class at least 1.0
chases, wall or ceiling openings and prior to
■■ Measuring uncertainty ≤ 5 % (with reference to
screeding or installation of panelling
measured value)
Pipe parts to ■■ A pressure drop of 0.1 mbar must be detectable
Freely accessible pipes with fittings
be tested
Test medium Air or inert gas (N2, CO2) Time of test Prior to initial commissioning, in the case
of underground oil pipes prior to covering
Test pressure 2.5/3 (response pressure of safety valve)
and after all types of work on the oil pipe
(except for oil filter change)
Pipe parts to
Pipes with connection points and fittings
be tested

1. Pressure test

Test of solar systems Test medium Air/inert gas


(N2, CO2)
Liquid

Test pressure Max. operating Max. operating


Solar systems are subject to a mandatory pressure test prior to pressure x 1.1 pressure x 1.3, at
flushing according to the manufacturer's instructions. It is not least 5 bar
advisable to perform a test with water.
Temperature
10 min 10 min
Time of test New installations prior to filling and flushing of compensation
the solar circuit Test duration Aboveground Aboveground
Pipe parts to pipes: 10 min pipes: 10 min
Pipes with connection points and fittings Underground Underground
be tested
pipes: 30 min pipes: 30 min
Test medium Air or inert gas (N2, CO2)

1. Pressure test 2. Strength test 2. Tightness test

Test 110 mbar to 1 bar ≤ DN 50: 3 bar Test pressure 110 mbar
300 mbar (vacuum)
pressure > DN 50: 1 bar (overpressure)

Test duration 10 min System ≤ 100 l: 30 min Temperature


10 min 10 min
Each additional 100 l: compensation
+10 min Test duration 10 min 10 min

www.afriso.com 35
Pressure measurement Tightness test

Test of gas pipes


DVGW (German Technical and Scientific Association for Gas and performed and gas admitted, the final test is carried out using leak
Water) TRGI (German Technical Rules for Gas Installations) defines detectors (e.g. GSP or CAPBs® GS 10). All connection points, for
the rules for all pressure tests on gas pipes (underground pipes, example at the gas meter, the pressure controller or the gas-con-
aboveground outdoor pipes, indoor pipes). Affected pipe sections suming equipment, are tested for leaks.
must be isolated from the gas-carrying pipe. After the test has been

Load test Pressure test

Time of test New installations prior to painting, insulation, Time of test New installations immediately prior to blowing
plastering or other types of covering in of the gas if the tightness test or the evalu-
ation of serviceability has not been performed
Pipe parts to Pipes without fittings or with fittings if the
immediately before
be tested nominal pressure rating of such fittings is
at least as high as the test pressure. Pipe Pipe parts to
Pipes with fittings
openings must be closed with metallic com- be tested
ponents; connection of gas-carrying pipes
Test medium Air or inert gas (N2, CO2)
is not permitted. Connection points without
corrosion protection. Test pressure Max. 50 mbar
Test medium Air or inert gas (N2, CO2) Temperature System < 100 l: 10 min
compensa- System > 100/200 l: 30 min
Test pressure 1 bar tion System > 200 l: 60 min
Test duration 10 min Test duration Approx. 5 minutes

Evaluation of serviceability/ Tightness test


determination of amount of gas leakage
2 Time of test New installations prior to painting, insulation,
plastering or other types of covering, decom-
Pipe parts to Pipes including fittings, but without gas-con- missioned pipes prior to re-commissioning,
be tested suming equipment, control and safety equip- decommissioned pipes
ment. Pipe parts to Freely accessible pipes with fittings, however,
Test medium Air or inert gas (N2, CO2) be tested without gas-consuming equipment, control
and safety equipment. Connection points
Test pres- Operating pressure, usually 23 mbar without corrosion protection.
sure
Test medium Air or inert gas (N2, CO2)
Test duration Min. 1 min, max. 10 min
Test pres- 150 mbar
sure
Test result Amount of leakage Serviceability Temperature System < 100 l: 10 min
0 l/h Tight compensa- System > 100/200 l: 30 min
tion System > 200 l: 60 min
< 1 l/h Unlimited
Test duration System < 100 l: 10 min
≥ 1 l/h and < 5 l/h Reduced
System > 100/200 l: 20 min
≥ 5 l/h None System > 200 l: 30 min

Test of drinking water systems


Pipe parts to The tightness test with water may only be performed by
Newly laid pipes with fittings means of hygienic components and with filtered drinking
be tested
water. In the case of an extended duration between the
Test medium Air, inert gas (N2, CO2) or water pressure test and commissioning, a dry tightness test must
be performed to avoid pollution/microbial contamination of
the system. The test is carried out as per ZVSHK (German
1. Tightness test* 2. Strength test* Central Association of the HVAC Industry) specifications.
Test pres- 150 mbar ≤ DN 50: 3 bar
sure > DN 50: 1 bar
Temperature 30 min -
compensa-
tion
Test duration System < 100 l: 120 min 10 min
Each additional 100 l:
+20 min
* Specifications for test medium air

36 www.afriso.com
Tightness test Pressure measurement

LEAK TEST SETS

DPK 60-5

Mechanical test set for starters

Ideal for pressure tests of gas/oil and water lines

2 pressure gauges for improved reading accuracy

Pressure test valve with high-precision adjustment


for easy adjustment of the filling pressure

Convenient quick-action coupling system for easy


and fast adaptation to the task at hand

Application For easy tightness checks (150 mbar) and load tests (1 bar) on gas pipes and for checking the con-
nection and flow pressure. Can also be used for tightness checks (150 mbar) and strength tests (3
bar) on drinking water pipes as per ZVSHK (German Central Association of the HVAC Industry). Ideal
for acceptance tests of heating system pipes, solar system pipes, underfloor heating systems, liquid
gas pipes and waste water pipes. Also suitable for pressure adjustments/tests or vacuum/tightness
tests on oil pipes and oil pumps.

Technical Ranges Scope of delivery


specifications Test pressure gauge 1: 0/6 bar ■■ Pressure gauge 0/6 bar with impact protection

Test pressure gauge 2: Dual scale 0/200 ■■ Pressure gauge with dual scale 0/200 mbar

mbar and 0.5/1.5 bar with impact protection


and 0.5/1.5 bar ■■ Pressure test valve with quick-action coupling

and high-precision adjustment valve


Application areas ■■ Hand-operated bulb pump with valve and
Atmospheric pressure:750/1100 hPa
connecting hose
Humidity: 20/80 % rH ■■ 2 x conical test plug ¾" to 1¼" with

Operating temperature range plug-in nipple


■■ 2 x connection hose (300 mm) with quick-action
Ambient: 0/40 °C
Medium: 0/40 °C coupling and plug-in nipple
■■ Connection hose (1 m) with quick-action
Storage: -20/+50 °C
coupling and plug-in nipple
Dimensions ■■ Y connector with shut-off valve, 2 x quick-action

Test pressure gauge with impact protection: Ø coupling and 1 x plug-in nipple
100 mm ■■ Robust plastic case with foam inlay

Case (W x H x D ): 450 x 136 x 365 mm


Weight
4.6 kg

DG: H, PG: 4 Part no. Price €


Leak test set DPK 60-5 569290

www.afriso.com 37
Pressure measurement Tightness test

LEAK TEST SETS

CAPBs ®-enabled
set DPK 60-6 ST

Ready-to-use test set for professional tightness


tests

Can be modularly extended for other tests

With CAPBs®-enabled digital pressure measuring


instrument (S4600 ST) with Bluetooth® Smart
technology, high measuring accuracy and baromet-
ric pressure determination for compensation of
air fluctuations during measurements and for
temperature compensation

2 Extended measuring range 0/5,000 bar

Integrated timer function for long-term measure-


ments, measuring duration freely selectable in
increments of one minute (up to 900 min).

Pressure test valve with high-precision adjustment


for easy adjustment of the filling pressure

microSD card for data management and


documentation on the PC
Also
Large TFT colour display (W x H: 45 x 60 mm)
available
as
Convenient quick-action coupling system for easy
CAPBs® and fast adaptation to the task at hand

Option data logger: Data logging once per second


during measurements (XML format)

Measurement logs as QR codes

38 www.afriso.com
Tightness test Pressure measurement

Application For pressure tests as per DVGW worksheet G600. Suitable for tightness tests (150 mbar) and load
tests (1 bar) on gas pipes and for checking the connection and flow pressure as well as the pressure
loss. Can also be used for tightness tests (150 mbar) and strength tests (3 bar) on drinking water
pipes as per ZVSHK (German Central Association of the HVAC Industry). Ideal for acceptance tests
of heating system pipes, solar system pipes, underfloor heating systems, liquid gas pipes and oil
pipes. The enclosed digital pressure measuring instrument meets the current DVGW (German
Technical and Scientific Association for Gas and Water) requirements as per TRGI (German Technical
Rules for Gas Installations) and the required reading accuracy (0.1 mbar) for tests of oil pipes.

Technical Measuring range Scope of delivery


specifications ± 5,000 mbar ■■ Digital pressure measuring instrument S4600 ST

with Bluetooth® Smart technology, power supply


Resolution
unit and charging cable
0.1 mbar ■■ MicroSD card, USB adapter and USB 2.0

Operating temperature range card reader


■■ Pressure test valve with quick-action coupling
Ambient: 0/40 °C
Storage: -20/+50 °C and high-precision adjustment valve
■■ Hand-operated bulb pump with valve and

Hours of operation connecting hose


Max. 38 hours ■■ 2 conical test plugs for pipe diameter

Weight ¾" to 1¼" with plug-in nipple


■■ Y connector
2.65 kg
(2 x quick-action coupling/1 x plug-in nipple)
Dimensions (W x H x D) ■■ Connection hoses with plug-in nipple and

S4600 ST: 66 x 143 x 37 mm quick-action coupling


Case: 450 x 136 x 365 mm ■■ System case L “DPK”

Display
TFT colour display, W x H: 45 x 60 mm 2
Supply voltage
Lithium-ion battery (3.6 V/1,800 mAh)
or USB power supply unit

i
See chapter 7 for options DG: H, PG: 4 Part no. Price €
and accessories. Leak test set DPK 60-6 ST 560006

www.afriso.com 39
Pressure measurement Tightness test

LEAK TEST SETS

CAPBs ®-enabled
set DPK 60-7 ST

Ready-to-use set for all tightness tests, fully


integrated in robust system case

Can be modularly extended for other pressure tests

Digital CAPBs®-enabled pressure measuring


instrument (DPK 60-7 ST) with Bluetooth® Smart
technology, high measuring accuracy and baromet-
ric pressure determination for compensation of
air fluctuations during measurements and for
temperature compensation

2 Ideal serviceability evaluation/determination of


amount of gas leakage

TÜV- Additional external sensors can be connected


tested (temperature, pressure)
as per
DVGW Large TFT colour display (W x H: 45 x 60 mm)
G5952
Integrated timer function for long-term measure-
ments, measuring duration freely selectable in
increments of one minute (up to 900 min).

Pressure test valve with high-precision adjustment


for easy adjustment of the filling pressure
Also
Convenient quick-action coupling system for easy
available and fast adaptation to the task at hand
as
CAPBs® microSD card for data management and
documentation on the PC

Option data logger: Data logging once per second


during measurements (XML format)

Measurement logs as QR codes


(QR code reader in EuroSoft mobile)

Printer connectivity via IR interface or Bluetooth®


Smart

40 www.afriso.com
Tightness test Pressure measurement

Application For pressure tests as per DVGW worksheet G600. Suitable for tightness tests (150 mbar) and load
tests (1 bar) on gas pipes and for checking the connection and flow pressure. Can also be used for
tightness tests (150 mbar) and strength tests (3 bar) on drinking water pipes
as per ZVSHK (German Central Association of the HVAC Industry). Ideal for evaluation of serviceabili-
ty and acceptance tests of heating system pipes, solar system pipes, underfloor heating systems,
liquid gas pipes and oil pipes. The enclosed digital pressure measuring instrument is already TÜV-
tested as per DVGW G5952 and meets the current DVGW (German Technical and Scientific
Association for Gas and Water) requirements as per TRGI (German Technical Rules for Gas
Installations) for measuring instruments of class D and the required reading accuracy (0.1 mbar) for
tests of oil pipes.

Technical Measuring range Approval


specifications ± 1,500 mbar TÜV-tested as per DVGW G5952
Resolution Scope of delivery
0.1 mbar ■■ Digital pressure measuring instrument

DPK 60-7 ST with Bluetooth® Smart technology,


Operating temperature range
power supply unit and charging cable
Ambient: 0/40 °C ■■ MicroSD card
Storage: -20 /+50 °C ■■ USB adapter and USB 2.0 card reader

■■ Pressure test valve with quick-action coupling


Hours of operation
Max. 38 hours and high-precision adjustment valve
■■ Valve unit with shut-off fitting

Weight ■■ Syringe for test volume

5.85 kg ■■ Hand-operated pump with check valve

■■ Hand-operated bulb pump with valve and


Dimensions (W x H x D)
S4600 ST: 66 x 143 x 37 mm connecting hose
■■ 2 conical test plugs for pipe diameter
Case: 500 x 170 x 420 mm
Display
¾" – 1¼" with plug-in nipple and 1 conical 2
test plug for pipe diameter ½" – ¾" with
TFT colour display, W x H: 45 x 60 mm plug-in nipple
■■ Y connector
Supply voltage
Lithium-ion battery (3.6 V/1,800 mAh) (2 x quick-action coupling/1 x plug-in nipple)
■■ Connection hoses with plug-in nipple
or USB power supply unit
and quick-action coupling
Capacity per stroke of hand-operated pump ■■ Robust plastic system case

Approx. 200 cm3

i
See chapter 7 for options DG: H, PG: 4 Part no. Price €
and accessories. Leak test set DPK 60-7 ST 560007

www.afriso.com 41
Leak location Gas detectors

Gas detectors GSP

Also
available
as
CAPBs®

GSP 3
GSP 1

GSP 3 Flex

Fast and reliable detection of flammable gases

Sensor for a wide range of flammable gases (base calibration: methane)

Sensor protection for long service life


2 Flexible gas probe for use in spaces difficult to access (GSP 1, GSP 3 Flex)

Audible alarm if limit values are exceeded

Adjustment of alarm threshold by means of a key and zero correction (GSP1)

Application Detection of gas leaks (flammable gases) in gas pipes as well as connection pieces and fittings, gas
meters, gas burners and gas tanks. Alarm GSP1: When a freely adjustable limit value is exceeded, the
instrument activates an audible alarm. Alarm GSP3: The intensity of the escaping gas is indicated by
the three LEDs. At the same time, the instrument generates an audible signal whose frequency is
proportional to the gas concentration.

Technical
GSP 1 GSP 3 / GSP 3 Flex
specifications
Measuring range (methane) 0/2,000 ppm

Sensitivity (methane) 20/50 ppm

Operating temperature Ambient: 5/40 °C


range Storage: -5/+40 °C

Hours of operation 24 hours 10 hours

Weight (with battery) 360 g 160 g

Dimensions W x H x D 72 x 130 x 26 mm W x H x D 60 x 124 x 30 mm

Indication Diode chain, 20 diodes 3 LEDs

NiMH battery 5 V/1,600 mAh, 2 x 1.5 V alkaline battery


Supply voltage
external power supply unit (Mignon, AA)

DG: H, PG: 4 Part no. Price €


Gas detector GSP 1 with flexible probe, battery and
561191
power supply unit NTE 6
Gas detector GSP 3 503401
Gas detector GSP 3 Flex 503402

42 www.afriso.com
Options/accessories Pressure measurement

Options and accessories for


pressure measuring instruments

Pressure test valve ADV 2


with quick-action coupling and high-preci-
sion adjustment valve for easy adjustment of
Connection kit ASS-DP the filling pressure
for pressure measuring instruments for Part no. 500670
differential pressure measurement
Part no. 500237

Test plugs/multiple connection plug


Conical and cylindrical test plugs with plug-in
nipple wing screw, suitable for quick-action
coupling system
conical ½" to ¾" Part no. 500678.1
conical ¾" to 1¼" Part no. 500678.2
cylindrical ½" Part no. 500678.3
cylindrical ¾" Part no. 500678.4 2
cylindrical 1" Part no. 500678.5
cylindrical 1¼" Part no. 500678.6
3
/8" and ¾" Part no. 500679.1
½" and 1" Part no. 500679.2
1" and 1¼" Part no. 500679.3

Single pipe union connector


For gas fittings
Part no. 500693
Connection kit
high pressure ASS-HD
Pressure-resistant up to 15 bar
Part no. 500234

Connection kit
tank protection
ASS-TS Option data logger
For inspecting and adjust- Data logging once per second during
ing Eurovac/Europress measurements (XML format)
Part no. 569843 Part no. 511010

www.afriso.com 43
TMD 9

Series FT

MFM 22
TEMPERATURE/MOISTURE MEASUREMENT

Handheld measuring instruments for


moisture in materials and for humidity

OVERVIEW

Product highlight: Moisture measuring instrument MFM 22 46

TEMPERATURE MEASUREMENT

Temperature measuring instrument TM 7 / TMD 7 48

Temperature measuring instrumentTMD 9 49


3
Temperature measuring instrumentTM 6 50

Infrared temperature measuring instrumentTM 8-IR 50

HUMIDITY/MOISTURE MEASUREMENT

Moisture measuring instrumentMFM 22 51

Humidity/air temperature measuring instrumentFT 30 – FT 50 53

45
Temperature/moisture measurement Moisture measuring instrument

TÜV-tested measurement of moisture in materials


Product highlight: MFM 22

All-rounder

Probes for the assessment of a great variety of


materials such as pellets, wood chips, log wood,
plaster, concrete, screed, straw, textiles, etc. turn
MFM 22 into an all-purpose handheld measuring
instrument for chimney sweeps, experts, surveyors,
architects, companies specialised in removing
TÜV-
water damage or wood-processing companies. approved
only with
MFM 22!

Ergonomic
3 Compact and light-weight design for
convenient handling

Knowledgeable

400 wood characteristics and 28 construc-


tion material characteristics as well as special
characteristics for the determination of the
moisture content in wood are stored in the
device and can be selected by simply pressing
a button.

User-friendly

Ready in no time: Assignment of favourites "Sort"


with frequently measured firewood types and
wood chips as per 1st German Federal Immission
Act.

46 www.afriso.com
Moisture measuring instrument Temperature/moisture measurement

Accurate

Temperature-compensated
evaluation of the residual
moisture content of materials
in compliance with directives
and standards (1st German
Federal Immission Act)

Intuitive

Menu-guided three-point mean


value measurement for split logs.

TÜV-
approved
only with
MFM 22!

Reliable
3
Fully automatic Hold function for stable
measurements even in the case of
variations caused by, for example,
electrostatic charges.

Fast

Fast evaluation of the condition


of the material via indication of a
reference value "DRY" to "WET".

Approved

TÜV-approval as per VDI 4206-4.


First TÜV-tested standalone wood
moisture measuring instrument as
per 1st German Federal Immission
Act.

www.afriso.com 47
Temperature/moisture measurement Temperature measuring instrument

Temperature measuring
instrument
TM 7 / TMD 7

Short response time for measurements at cycles


Also of a second
available
as Large, lit LC display for simultaneous indication
CAPBs® of two measured values

Hold function for measured values

Fast determination of differential temperature (TMD 7)

Automatic segment test when program starts

Magnet in protective housing for hands-free operation

Robust protective housing against dirt, impact


and shock

3
Application For temperature measurement on surfaces, liquids, soft plastic media or in air and gases.

Technical
Model Measuring range Resolution Accuracy (% of measured value)
specifications
0.1 °C (-50.0/+99.9 °C) 3.0 % ± 2.0 K (-50.0 to 0 °C)
TM 7 -50/+1,100 °C 0.5 % ± 0.5 K (0 to 99,9 °C)
1 °C (100/1,100 °C) 0.5 % ± 1 K (100 to 1,100 °C)
0.1 °C (-50.0/+99.9 °C) 3.0 % ± 2.0 K (-50.0 to 0 °C)
TMD 7 -50/+1,100 °C 0.5 % ± 0.5 K (0 to 99.9 °C)
1 °C (100/1,100 °C) 0.5 % ± 1 K (100 to 1,100 °C)

Operating temperature range Indication of measured values


Ambient: 0/50 °C °C or °F
Storage: -10/+50 °C
Probe connection
i Hours of operation TM 7: 1 x socket for thermocouple
See chapter 7 100 hours TMD 7: 2 x socket for thermocouple
for accessories.
Weight Supply voltage
Approx. 250 g 2 x 1.5 V Mignon (AA) batteries
Dimensions Approvals
W x H x D 66 x 143 x 37 mm BImSchV, EN 50379-2
Display Scope of delivery
LCD, transflective Measuring instrument with batteries,
W x H: 46 x 48 mm protective sleeve with magnet

DG: H, PG: 4 Part no. Price €


Temperature measuring instrument TM 7 570056
Temperature measuring instrument TMD 7 570057

48 www.afriso.com
Temperature measuring instrument Temperature/moisture measurement

Temperature measuring
instrument
TMD 9

Short response time for measurements at cycles


Also of a second
available
as Large TFT colour display (W x H: 45 x 60 mm)
CAPBs® for simultaneous display of four measured values

microSD card for system-independent storage


of measurement logs (HTML format)

Data logger function for long-term measurement

Multifunctional use of temperature probes with


"type K connection"

Fully automatic device check, manual and


automatic zero calibration during program start

Three magnets in protective housing for hands-free


operation

3
Application For temperature measurement on surfaces, liquids, soft plastic media or in air and gases.

Technical
Model Measuring range Resolution Accuracy (% of measured value) Thermocouple
specifications
± 1 °C + 1 digits (up to 300 °C) Type K
TMD 9 -50/+1,100 °C 0.1 °C ± 1 % of meas. value (> 300 °C) (NiCr-Ni)

Operating temperature range Supply voltage


Ambient: 0/40 °C Lithium-ion battery (3.6 V/1800 mAh)
Storage: -20/+50 °C or power supply unit (mini USB)
Hours of operation Interfaces
Up to 38 hours (Eco mode) Infrared, Bluetooth® Smart,
QR code generator, microSD card slot
Weight
i Approx. 154 g Data memory
See chapter 7 microSD card (incl. data logger function)
Dimensions
for accessories. W x H x D: 66 x 143 x 37 mm Data logger
1–999 seconds, interval freely selectable
Display
2.8 " TFT colour display Approvals
W x H: 45 x 60 mm EN 50379-1/-2
Indication of measured values Scope of delivery
°C or °F Measuring instrument, power supply unit, mini
USB and microSD card with USB 2.0 SD card
Probe connection
reader
2 x socket for thermo couple

DG: H, PG: 4 Part no. Price €


Temperature measuring instrument TMD 9 P071000916

www.afriso.com 49
Temperature/moisture measurement Temperature measuring instrument

Measuring instruments for temperature


and temperature/moisture TM

TM 6 TM 8-IR

Short response time for measurements Non-contact temperature measurement


at cycles of a second
Backlit LC display
Min./max. and Hold function
Hold function for measured values
Memory for 19 measured values
Short response time (< 1 s) for
1 point Cal function: Correction of measurements at cycles of a second
measured values, e.g. for compensation
of probe tolerances 
Ratio distance to Ø measuring point 11:1

Standard connector type K for all


NiCr-Ni probes

Application For temperature measurement on surfaces, For temperature measurements of surfaces and
3 liquids, soft plastic media or in air and gases. for measurements of moving parts (e.g. paper
reels, tyres) or live parts (e.g. electrical assem-
blies, transformers). Ideal for applications in the
food industry.

Technical Measuring range Measuring range


specifications -99.9/+1,370 °C Infrared: -33/+500 °C (ratio 11:1)
Thermocouple: -64/+1400 °C
Resolution
0.1 °C from -99.9/+299.9 °C Accuracy
Infrared: ± 2 °C
Accuracy
Thermocouple: ± 1 °C
± 0.5 °C ± 1 digit
Operating temperature range
Operating temperature range Ambient: 0/50 °C
Ambient/storage: 0/50 °C Storage: -20/+65 °C
Hours of operation Hours of operation
200 hours 140 hours
Weight Weight
i 240 g 180 g
See chapter 7 Dimensions Dimensions
for accessories. W x H x D 65 x 130 x 25 mm W x H x D 39 x 175 x 80 mm
Display Display
LCD, 1 line LCD, W x H: 25 x 24 mm
W x H: 42 x 21 mm
Supply voltage
Supply voltage 2 x 1.5 V AAA batteries
2 x 1.5 V AA batteries
Scope of delivery
Scope of delivery Measuring instrument with protective
Measuring instrument with batteries pocket and batteries

DG: H, PG: 4 Part no. Price €


Temperature measuring instrument TM 6 570038
Temperature measuring instrument TM 8-IR 570039

50 www.afriso.com
Moisture measuring instrument Temperature/moisture measurement

MOISTURE MEASURING
INSTRUMENT

MFM 22
Tested
as per
VDI 42 06 -4

TÜV-approval as per VDI 4206-4. First TÜV-tested


standalone wood moisture measuring instrument
as per 1st German Federal Immission Act

Device comes with characteristics for 400 wood types


and 28 construction materials stored in the software –
no complex conversion tables for construction material
required

Ready in no time: Assignment of favourites "Sort" with


frequently measured firewood types and wood chips
as per 1st German Federal Immission Act

Menu-guided three-point mean value measurement


for split logs

Auto-hold function: Fully automatic for determination of 3


an accurate measured value in the case of electrostatic
charge (e.g. dry wood)

Visual range alarm: The characteristic flashes if


the u value is < 8 % or > 40 %

Special electrode with temperature probe TÜV-tested


according to test report M 1167-01/15 as per VDI 4206-4
for wood chips and pellets

Insertion probe for wood chips and pellets with improved


ergonomics and optimised cable routing for superior
handling

Versatile application by means of special probes for


pellets, wood chips, log wood, screed, plaster,
concrete, brickwork, paper, etc.

Application For precise and standards-compliant evaluation of the residual


moisture content and the temperature of pellets and wood. The
integrated three-point mean value function (measured value as a
result of the mean value of measurements at three reference points
of the split log) also complies with the requirements of the 1st
German Federal Immission Act. MFM 22 is also suitable for meas-
urements of moisture in buildings (e.g. plaster, concrete, screed).
Water content and material moisture are determined by means of
a resistance method directly at the sample. The correct measured
value is calculated on the basis of material-specific characteristics.
The integrated temperature compensation is an essential feature
in obtaining correct measurements at wood fuels and the corre-
sponding wood chips or pellets. MFM 22 is the ideal general
purpose measuring instrument for residual moisture.

www.afriso.com 51
Temperature/moisture measurement Moisture measuring instrument

Technical Measuring range Dimensions


specifications Moisture u: 0/100 % W x H x D 71 x 142 x 26 mm
Temperature: -40/+200 °C
Display
Resolution u: 0.1 %
LCD, W x H: 38 x 25 mm
Accuracy
Supply voltage
± 0.2 % u
1 x 9 V block battery
± 0.5 % of measured value ± 0.3 °C
Approval
Operating temperature range
TÜV approval as per VDI 4206-4
Ambient: -25/+50 °C
Storage: -25/+70 °C
Weight
Approx. 175 g

Deep electrodes ELE-MS 110 for straw, plaster, brickwork


Insertion electrode ELE-ST 50-1/-2 with integrated
temperature probe for wood chips and pellets

TÜ V
ap pr oval
on ly
w ith
M FM 22 !

TÜ V
ap pr oval
3 w ith
M FM 22 !
on ly

for log wood and moisture in


materials (screed, concrete)
for moisture in construction

Ram electrode ELE-SE 10


Brush electrode ELE-BE
ELE-HE 20 for log wood

construction materials
Hammer electrode
Measurement cable 1 m

steel pins 40 mm, case


Measuring instrument

With TÜV approval


Hammer electrode
with connector,

Ram electrode
9 V battery,

MFM 22
ELE-HE 20

ELE-SE 10
MFM 22

sets

DG: H, PG: 4 Part no. Price €


Moisture measuring
• 569087
­instrument MFM 22
Moisture measuring
i instrument MFM 22, set 1
• • • P569087-1
See chapter 7 for options Moisture measuring
and accessories. • • • P569087-2
instrument MFM 22, set 2

52 www.afriso.com
Moisture measuring instrument Temperature/moisture measurement

Humidity/air temperature measuring


instruments series FT30 – FT50

Also
available
as FT 40 FT 50
CAPBs ®

FT 30

High accuracy

Four-digit LC display for temperature, dew point and relative humidity

Min./max. and Hold function

Magnet in protective housing for hands-free operation

Robust protective housing against dirt, impact and shock

Various probe versions 3

Application For temperature and relative humidity measurements as well as fast checks of climatic
conditions in rooms.

The different types of probes are permanently connected to the measuring instrument.
FT30: With probe at housing of measuring instrument
FT40: With probe at flexible spiral cable
FT 50: With probe at 30 cm probe

Technical Measuring range temperature Dimensions


specifications -40/+80 °C W x H x D 66 x 143 x 37 mm
Measuring range humidity Display
0/100 % rH LCD, transflective
W x H: 46 x 48 mm
Measuring range dew point (calculated)
-40/+120 °C Indication of measured values
°C or °F
Operating temperature range
Ambient: 0/40 °C Supply voltage
2 x 1.5 V AA batteries
Hours of operation
100 hours Scope of delivery
Measuring instrument with batteries
Weight (with battery)
220 g/290 g
(depending on version)

DG: H, PG: 4 Part no. Price €


Humidity/air temperature measuring instrument FT 30 570052
Humidity/air temperature measuring instrument FT 40 570053
Humidity/air temperature measuring instrument FT 50 570054

www.afriso.com 53
CAPBs® measuring units
AFRISO
LEVELCAPBs®

Universal sensor module system


Xxxxxx
with Bluetooth® Smart technology

OVERVIEW

CAPBs® sensor modules at a glance 56

CAPBs® – the modular system 60

BlueLine measuring instruments for CAPBs® 74

MEASURING UNITS

CAPBs® base handle BG 10 61

CAPBs® pressure PS 10 – 61 62

CAPBs® pressure transmitter P


 T 70 64

CAPBs® pressure and temperature F


 P 10 64

CAPBs® temperature TK 10 / TK 11 (type K connection) 65

CAPBs® temperature TK 20 – 50 66 4


CAPBs® humidity/temperature RH 80 67

CAPBs® air quality AQ 20 67

CAPBs® gas leak detection GS 10 68

CAPBs® detection CO 30 68

CAPBs® flow rate and temperature measurement FlowTemp® ST 69

SETS

CAPBs® set for tightness test DPK 60-6 sens 70

CAPBs® set for determination of amount of gas leakage D


 PK 60-7 sens 71

CAPBs® water set A


 DS-WS 72

CAPBs® set heating system check 2.0 72

CAPBs® set 4 Pa test 73

CAPBs® combination set 4


 Pa test/heating system check 2.0 73

55
CAPBs ® sensor modules Overview

CAPBs® sensor modules at a glance

Pressure Pressure Pressure Pressure Pressure Pressure


measurement measurement measurement measurement measurement transmitter

CAPBs®
PS 10 PS 20 PS 33 PS 40/41 PS 60/61 PT 70
(20 mbar) (180 mbar) (2 bar) (6 bar) (20 bar) (25 bar)

Measurement of ul- Check of connection


Application Test of water pipes
tra-fine pressure (Pitot and flow pressure Serviceability test Tightness and load Stress pressure test
(test medium water)
examples measurement) in gas-fired heating (TRGI) test of gas lines at pipe systems
as per ZVSHK
systems

Methane
Parameters/measured values

Propane (liquefied gas)


Butane
Temperature
pressure • • • • • •
Dew point
Humidity in %
CO
CO2
VOC
volume flow •* •*
Flow rate measurement (water)
Thermal disinfection
Measurements of filters, ventilati-
on systems, ducts
• • •
Measurements of production
facilities, tanks, gas pipes
• • • •

4 Burner adjustment/servicing
(gas, oil, solid fuel systems)
• •
Servicing of water heaters
pressure measurement • • • • • •
Tightness test (gas) • •
Load test (gas) • •
Serviceability test (gas) •
Tightness test (ZVSHK) •** • •** •***
Strength test (ZVSHK) • •** •***
Typical applications areas

Stress pressure test • •


Measurement of inlet pressure,
flow pressure, static pressure, • •
nozzle pressure
Pressure / vacuum measurement • • • • •
Differential pressure measure-
ment
• •
Vacuum measurement • • • •
Temperature measurement (flue
gas, air, external wall)
Temperature measurement
(water)
Surface temperature measu-
rement
Draft/chimney draft measurement • •
Ventilation loss measurement
Heating system check
4 Pa test
Gas leak detection
Gas concentration measurement
Moisture measurement (material/
moisture/indoor climate/mould)
Air velocity •* •*
* Accessories required, see catalogue page.
** With test medium air. Page 62 Page 62 Page 62 Page 62 Page 62 Page 64
*** With test medium water.

56 www.afriso.com
Overview CAPBs ® sensor modules

Humidity/
Pressure/ Gas leak CO Flow rate/tem-
Temperature air tempera- Air quality
temperature detection detection perature
ture

FP 10 TK 10 – TK 50 RH 80 AQ 20 GS 10 CO 30 FlowTemp® ST

Determination of ven- Fast and reliable detection Detection of leaking CO concentration


Determination of temperatures Function tests of drinking
tilation loss (heating Monitoring or humidi- of VOCs (volatile organic flammable gases measurement in
on surfaces, in liquids and in water heaters and con-
system check), 4 ty in closed rooms compounds) and CO2 (e.g. methane) boiler rooms
gases nected pipe systems
Pa test




•* • • •





• •


• •

• 4


• •


•*



• •
• •
• •

Page 64 Page 65 Page 67 Page 67 Page 68 Page 68 Page 69

www.afriso.com 57
CAPBs ® sensor modules Overview

Welcome to the future


Cutting edge measuring technology -
AFRISO CAPBs® measuring units.

Comprehensive
Easy extension of BlueLine measuring instruments*
by a great variety of applications such as pressure
measurement, temperature measurement, humidity
measurement, volume flow and Pitot measurement,
gas leak detection, flow measurement, etc.

Wireless
Wireless, immediate transmission
of the measurement data to your
AFRISO measuring instrument,
smartphone or tablet with Bluetooth®
Smart technology.

Flexible
Multi-purpose key with customisable
function assignment for ease of use and
consistent operation of the CAPBs®,
regardless of site.

Accurate
4 Position-independent, temperature-com-
pensated sensor technology for maximum
precision in all measuring scenarios.

Modular
Numerous, versatile application
thanks to modular design with
universal base handle for all
sensor modules.

Universal
Compatible with our proven
BlueLine measuring instruments*
or your smartphone and tablet.

The following measuring instruments can be


immediately used with the CAPBs®:
*B
 LUELYZER ST, EUROLYZER STx, MULTILYZER STe/STx,
pressure measuring instrument series S4600 ST and
temperature measuring instrument TMD 9

58 www.afriso.com
Overview CAPBs ® sensor modules

Proven
Easy documentation of measurement results
on site via IR or Bluetooth® Smart interface
of the BlueLine measuring instrument.

Focused
Measurement data centre for saving the measurement
results in the BlueLine measuring instrument or the app and
creating printouts on site. Optional data logger function for
data output in XML format for flexible further processing
with standard software applications such as MS Excel.

Error-free
Simultaneous storage of all measured data to the
measuring instrument or the mobile devices avoids
errors, for example caused by incorrect readings.

Ergonomic
Light-weight. ergonomic handle made of robust,
high-quality plastic with integrated magnet for
hands-free operation.

Ready for measurement


Free firmware update for BlueLine
measuring instruments* with pre-installed
measurement menus for all available
CAPBs® – can be done by the user at any
time via the microSD card.

Independent
Free app for EuroSoft live for operation of all CAPBs®
live via smartphone and tablet. With pre-installed meas-
urement menus for special applications (for example,
gas line checks) and graphical representation of the
measurement results.

Quality
100 % made in Germany.

Energy-saving
Automatic switching off of the CAPBs® when the
Bluetooth® Smart connection is closed ensures low
energy consumption.

Further
information:

Revolutionary
Continuous, simultaneous flow and temperature measurement
in water applications with the new, TÜV-tested flow
rate/temperature measuring instrument FlowTemp® ST.

www.afriso.com/capbs

www.afriso.com 59
CAPBs ® sensor modules Overview

Universal. Accurate. Flexible.


Modular system

The new AFRISO CAPBs® constitute a modular system consist- The battery compartment and the unlock button for exchang-
ing of the universal base handle CAPBs® BG 10 and an appli- ing the CAPBs® sens are also located at the rear. The snap-in
cation-specific sensor module CAPBs® sens for a wide variety mechanism on top of the base handle is standardised for all
of measured variables such as pressure, temperature, humid- CAPBs® sens.
ity. The base handle CAPBs® BG 10 holds the various sensor A multi-purpose key is located at the front; it is used for switch-
modules CAPBs® sens. The base handle can be combined with ing the unit on and off, for zero adjustment, for activating the
any sensor module to form a complete CAPBs® measuring unit. Hold mode or for starting the data logger function. The mul-
Each measuring unit can transmit the measured data immedi- ti-colour LED displays the status of the CAPBs® measuring unit
4 ately and without a delay to the AFRISO BlueLine measuring by means of different colours and flashing frequencies. For ex-
instruments via Bluetooth® Smart and, via a free app for different ample, BLUE means "Establishing Bluetooth® Smart connec-
operating systems, also to a smartphone or tablet. This results tion" or GREEN "Connected to an evaluation unit". The base
in a vast array of measuring units – all tasks of, for example, a handle also contains a device which indicates excess concen-
heating system engineer or a chimney sweep can be performed trations or limit values by means of audible signals with different
with a single measuring instrument. The ergonomic base handle frequencies.
CAPBs® BG 10 is equipped with three magnets at the rear side.

Front CAPBs® base handle BG 10 Back Top

4
8

5
1

1 LED
2 Multi-purpose key
2 3 Protective sleeve
4 Unlocking mechanism for
removing CAPBs® sens
5 Tripod socket (1/4" UNC) for
7 mounting on cameratripods
3
or selfie sticks
6 Battery compartment
7 Magnet
8 Snap-in mechanism for
CAPBs® sens

60 www.afriso.com
Base CAPBs ® sensor modules

CAPBs®

Base handle
BG 10

Description
Universal base handle for all CAPBs® sensor modules. Ergonomic
handle with three magnets and battery compartment at the rear
of the housing. Multi-colour LED and multi-purpose key on the
front. With integrated device for audible signals and Bluetooth®
Smart module.

Technical specifications
Dimensions (W x H x D): 45 x 140 x 39 mm
Weight: 113 g
Supply voltage: 2 x 1.5 V AAA alkaline batteries or
2 x A A A NiMH batteries
(1.2 V / 900 mAh)
Interface: Bluetooth® Smart

Modular replacement system

DG: H, PG: 4 Part no. Price €


CAPBs® base handle BG 10 M091000017

www.afriso.com 61
CAPBs ® sensor modules Pressure measurement

Base handle BG 10 CAPBs®

Pressure PS

Pressure CAPBs® sens PS 20,


Pressure CAPBs® sens PS 10,

180 mbar 2 x Ø 8 mm
20 mbar 2 x Ø 8 mm

Measurement of ultra-fine pressure (PS 10)


Pressure CAPBs® sens PS 33,

Pressure CAPBs® sens PS 40,

Check of connection and flow pressure in gas-fired hea-


ting systems (PS 20)
2 bar 1 x Ø 8 mm

6 bar 1 x Ø 8 mm

Evaluation of serviceability/determination of amount of


gas leakage at gas lines as per TRGI. The sensor module
features barometric pressure determination and
is DVGW-certified (PS 33)

Tightness and load test of gas lines (PS 40/41)


Pressure CAPBs® sens PS 60,

Pressure CAPBs® sens PS 61,


Pressure CAPBs® sens PS 41,

20 bar 1 x Ø 3 mm (Festo)

Stress pressure test at pipe systems (PS 60/61)


6 bar 1 x Ø 3 mm (Festo)

20 bar 1 x Ø 8 mm

4
Description Sensor module for measurement of pressure, vacuum and differential pressure of non-corrosive,
gaseous, dry media. The pressure sensors are available with various connections in the five
measuring ranges 20 mbar , 180 mbar, 2 bar, 6 bar and 20 bar. Manual shifting of the zero point
allows you to double the measuring range. The high-quality sensors are extremely accurate,
orientation-independent and temperature-compensated.

62 www.afriso.com
Measuring units CAPBs ® sensor modules

PS 10 PS 20 PS 33 PS 40 / PS 41 PS 60 / PS 61
Anwendung (20 mbar) (180 mbar) (2 bar) (6 bar) (20 bar)
Differential pressure • •
Pressure loss • • • • •
Connection pressure/flow
• •
pressure
Flow rate • •
Stress pressure test •
Test of gas pipes as per TRGI
Tightness test • • •
Load test • •
Combined tightness
• •
and load test
Determination of amount of

gas leakage
Test of drinking water systems as per ZVSHK
Tightness test • • •
Strength test • •
Test of heating systems
Tightness test • •
Test of solar systems
Pressure test • • • •
Strength test • •
Test of oil pipes
Tightness test • • •
Pressure test • •

Technical specifications 4
Dimensions (H x W x D): 74 x 42 x 35 mm 74 x 42 x 35 mm 74 x 42 x 35 mm 74 x 42 x 35 mm 74 x 42 x 35 mm
Weight: 34 g 34 g 34 g 30 g 26 g
Interface: Bluetooth® Smart Bluetooth® Smart Bluetooth® Smart Bluetooth® Smart Bluetooth® Smart
Measuring range: -20 / +20 mbar -180 / +180 mbar -1 / +2 bar -1 / +6 bar -1 / +20 bar
0.5 / 50 m/s 0.5 / 50 m/s
Accuracy: ±0.003 mbar ±0.03 mbar ±0,3 mbar ±0.3 mbar ±1 mbar
0.5 % displayed 0.5 % displayed 0,5 % displayed 0.5 % displayed 0.5 % displayed
value value value value value
±1 digit ±1 digit ±1 digit ±1 digit ±1 digit
Resolution: 0.001 mbar 0.01 mbar 0,1 mbar 0.1 mbar 0.1 mbar
(< 99.99) (< 999,99) (< 999.99) (< 999.99)
0.1 m/s 0.1 mbar (> 100.0) 1 mbar (> 1.000) 1 mbar (> 1,000) 1 mbar (> 1,000)
0.1 m/s
Hose connection: Ø 8 mm Ø 8 mm Ø 8 mm Ø 8 mm or Ø 8 mm or
Ø 3 mm (Festo) Ø 3 mm (Festo)

i DG: H, PG: 4 Part no. Price €


See chapter 7 for CAPBs® base handle BG 10 M091000017
­accessories. Pressure CAPBs® sens PS 10, 20 mbar 2 x Ø 8 mm M090050110
Pressure CAPBs sens PS 20, 180 mbar 2 x Ø 8 mm
®
M090010110
Pressure CAPBs® sens PS 33, 2 bar, 1 x Ø 8 mm, DVGW M090192910
Pressure CAPBs® sens PS 40, 6 bar 1 x Ø 8 mm M090082910
Pressure CAPBs® sens PS 41, 6 bar 1 x Ø 3 mm (Festo) M090083010
Pressure CAPBs® sens PS 60, 20 bar 1 x Ø 8 mm M090102910
Pressure CAPBs® sens PS 61, 20 bar 1 x Ø 3 mm (Festo) M090103010

www.afriso.com 63
CAPBs ® sensor modules Pressure measurement

Base handle BG 10

Base handle BG 10

Pressure/temperature CAPBs® sens FP 10


Pressure transmitter CAPBs® sens PT 70,
25 bar DN5
CAPBs® CAPBs®
pressure transmitter PT 70 pressure and temperature FP 10

Application ■■ Pressure tests of oil pipes ■■ Flow rate measurement (Pitot tube)
■■ Tightness tests/strength tests of drinking ■■ Surface loss
water installations as per ZVSHK ■■ Ventilation loss (Pitot tube)

■■ Pressure loss test ■■ 4 Pa measurement (hose kit)

■■ Pressure test at pipe systems ■■ Heating system check 2.0 (Pitot tube)

■■ Stress pressure test at pipe systems

Description Pressure transmitter for measurements in Sensor module for simultaneous, continuous
liquids and corrosive media. measurement of temperature and pressure.
The CAPBs® allows for convenient flow rate
measurement with a stable zero point.

Technical Dimensions Dimensions


specifications W x H x D: 42 x 76 x 35 mm W x H x D: 42 x 74 x 35 mm
4 Weight Weight
55 g 33 g
Interface Interface
Bluetooth® Smart Bluetooth® Smart
Measuring ranges Measuring ranges
0 / +25 bar -20 / +20 mbar
0.2 / 20 m/s
Accuracy
-50 / +600 °C
0.5 % of full scale
±1 digit Accuracy
±0.003 mbar
Resolution
0.5 % displayed value ±1 digit
0.1 bar
±0.1 m/s or ±5 % displayed value
Hose connection ±1.5 °C
Plug connection DN 5
Resolution
0.0001 mbar / 0.01 m/s / 0.1 °C

DG: H, PG: 4 Part no. Price €


CAPBs® base handle BG 10 M091000017
Pressure transmitter CAPBs® sens PT 70, 25 bar M090142810
Pressure/temperature CAPBs® sens FP 10 M090053210
Accessories
Hose kit SLS 4 Pa Test 500664
Pirot tube EP-SR 500663
Surface probe TFB-OF 120 522991

64 www.afriso.com
Temperature measurement CAPBs ® sensor modules

Base handle BG 10

Base handle BG 10

Temperature CAPBs® sens TK 11 type K


Temperature CAPBs® sens TK 10 type K
CAPBs® CAPBs®
temperature TK 10 type K temperature TK 11 type K

Application ■■ Temperature measurement ■■ Differential temperature measurement


■■ Determination of the temperatures of flow
and return

Description Temperature transmitter with standardised Temperature transmitter with two standardised
temperature socket type K. This allows for the temperature sockets type K. This allows for the
connection of all type K two-pole thermocou- connection of all type K two-pole thermocou-
ples and temperature probes (for example, the
ples and temperature probes (for example, the
complete AFRISO temperature probe range). In
complete AFRISO temperature probe range). conjunction with BLUELYZER ST, it is, for exam-
ple, possible to measure up to four temperature
values.

Technical Dimensions Dimensions


specifications W x H x D: 42 x 58 x 35 mm W x H x D: 42 x 58 x 35 mm
Weight Weight
22 g 22 g
4
Interface Interface
Bluetooth® Smart Bluetooth® Smart
Measuring ranges Measuring ranges
-50 / +1,150 °C -50 / +1,150 °C
(depends on thermocouple used) (depends on thermocouple used)
Accuracy Accuracy
±1.5 °C ±1.5 °C
Resolution Resolution
0.1 °C 0.1 °C
Connection Connection
Probe: 1x type K Probe: 2 x type K

DG: H, PG: 4 Part no. Price €

i CAPBs® base handle BG 10 M091000017


See chapter 7 for Temperature CAPBs® sens TK 10 type K M090000810
­accessories. Temperatur CAPBs® sens TK 11 type K (2 x) M090000910

www.afriso.com 65
CAPBs ® sensor modules Temperature measuring instruments

Base handle BG 10 CAPBs®

sens

Temperature CAPBs® sens


CAPBs
TemperatureCAPBs sens
®®

Temperature TK
Temperatur

TK 30
20
TK 20
TK

Application
■■ Temperature measurement
Temperature CAPBs® sens

Temperature CAPBs® sens

Temperature CAPBs® sens

Description
Sensor module for measurement of the tempera-
ture on surfaces, in liquids, soft plastic media and
in air with different, application-specific temperature
probes.
TK 35

TK 40

TK 50

Technical
specifications Spike probe Liquid probe Liquid probe Air probe Surface probe TK
TK 20 TK 30 TK 35 TK 40 50
Dimensions (W x H x D): 42 x 186 x 35 mm 42 x 187 x 35 mm 42 x 190 x 35 mm 42 x 187 x 35 mm 42 x 187 x 35 mm
Probe diameter 3 mm 1.5 mm 3 mm 4.7 mm 4 mm
Weight: 32 g 28 g 32 g 32 g 34 g
Interface: Bluetooth Smart ®
Bluetooth Smart ®
Bluetooth Smart
®
Bluetooth Smart
®
Bluetooth® Smart
Measuring ranges: -50 / +400 °C -50 / +400 °C -50 / +400 °C -50 / +400 °C -50 / +400 °C
Accuracy: ±1.5 °C ±1.5 °C ±1.5 °C ±1.5 °C ±1.5 °C
1 % displayed value 1 % displayed value 1 % displayed value 1 % displayed value 1 % displayed value
Resolution: 0.1 °C 0.1 °C 0.1 °C 0.1 °C 0.1 °C

DG: H, PG: 4 Part no. Price €


CAPBs® base handle BG 10 M091000017
Insertion probe CAPBs® sens TK 20, Ø 3 mm M090002210
Liquid probe CAPBs sens TK 30, Ø 1.5 mm ®
M090002310
Liquid probe CAPBs® sens TK 35, Ø 3 mm M090002410
Air probe CAPBs sens TK 40, Ø 4.7 mm ®
M090002510
Surface probe CAPBs® sens TK 50, Ø 4 mm M090002610

66 www.afriso.com
Climatic condition air quality CAPBs ® sensor modules

Base handle BG 10

Base handle BG 10
Humidity CAPBs® sens RH 80

Air quality CAPBs® sens AQ 20


CAPBs® CAPBs®
humidity/temperature RH 80 air quality AQ 20

Application ■■ Checks of the climatic conditions in rooms ■■ Evaluation of the air quality in rooms
■■ Mould prevention ■■ Inspection of filters
■■ Detection of leaks in

conjunction with hazardous substances


■■ Redundant measurement in

conjunction with PID measurements


■■ Evaluation of the air quality in

closed rooms (e.g. in schools, offices, con-


ference rooms, libraries etc.)

Description Sensor module for measurement of tempera- Sensor module for fast and reliable detection
ture and relative humidity in ambient air. of VOCs (volatile organic compounds) and
CO2 in ambient air. The gas concentration is
displayed by the evaluation unit as CO2 (ppm)
and TVOC (ppb); the CAPBs® measurement
unit provides an audible signal. 4

Technical Dimensions Dimensions


specifications W x H x D 42 x 82 x 35 mm W x H x D 42 x 58 x 35 mm
Weight Weight
51 g 30 g
Interface Interface
Bluetooth® Smart Bluetooth® Smart
Measuring ranges Measuring ranges
0 / 100 % r.h. 450 / 2,000 ppm CO2 equivalent (relative)
-40 / +80 °C 125 / 600 ppb TVOC equivalent
Accuracy Resolution
±2 % rH ±1 digit 1 ppm
±0.5 °C ±1 digit
Resolution
0.1 % rH
0.1 °C

DG: H, PG: 4 Part no. Price €


CAPBs® base handle BG 10 M091000017
Humidity CAPBs® sens RH 80 M090111210
Air quality CAPBs® sens AQ 20 M090120010

www.afriso.com 67
CAPBs ® sensor modules Gas detector

Base handle BG 10

Base handle BG 10

CO detection CAPBs® sens CO 30


Gas detection CAPBs® sens GS 10
CAPBs® CAPBs®
gas leak detection GS 10 CO detection CO 30

Application ■■ Gas leak detection ■■ CO detection and concentration measurement


■■ Detection of gas leaks (flammable ■■ Application in boiler rooms or at flue gas pipes,
gases) in gas pipes as well as for example for self-protection during flue gas
line tests
connection pieces and fittings,
gas meters, gas burners and gas
tanks.

Description Sensor module for fast and reliable Sensor module with electro-chemical sensor for
gas leak detection. The flexible fast and reliable detection of CO (carbon mon-
probe allows for use in spaces difficult to oxide) in ambient air. The CO concentration is
access. The gas concentration is displayed by displayed by the evaluation unit as CO value in
ppm; the CAPBs® measurement unit provides
the evaluation unit in "ppm"; the CAPBs® meas-
an audible signal when the alarm threshold is
urement unit provides an audible signal. The exceeded.
alarm threshold can be adjusted as required.
Due to the base calibration for methane, a wide
4 range of flammable gases is detectable. The
anti-poisoning protection function for the sensor
ensures a long service life.

Technical Dimensions Dimensions


specifications W x H x D 42 x 290 x 35 mm H x W x D: 42 x 64 x 35 mm
Weight Weight
51 g 27 g
Interface Interface
Bluetooth® Smart Bluetooth® Smart
Measuring range (methane) Measuring ranges
0 / 2,000 ppm 0 / 2,000 ppm CO
Resolution Resolution
10 ppm 1 ppm

DG: H, PG: 4 Part no. Price €


CAPBs® base handle BG 10 M091000017
Gas leak detection CAPBs® sens GS 10 M090131410
CO detection CAPBs® sens CO 30 M090163310

68 www.afriso.com
Measuring units CAPBs ®

CAPBs®

Flow rate and tem-


perature measure-
ment FlowTemp® ST

Application
■■ Verification of performance key "NL" of accumulator and con-

tinuous capacity
■■ Function checks of decentralised drinking water heaters

■■ Checking the output capacity of heat exchangers

■■ Inspection of heat exchangers

■■ Function tests of circulation lines

■■ Inspection of fittings (minimum volume flow)

■■ Determination of the water temperature at water taps

live ■■ Inspection of thermal mixing valves

■■ Acceptance tests of newly installed drinking water installations

■■ Verification and documentation of thermal disinfection

4
Description Sensor module for continuous, simultaneous determination of flow rate (l/min) and temperature
(°C) in water applications. The flow rate is measured with a high-precision capacitance flow sensor,
the temperature with a PT1000 module. Both sensors are integrated in a robust housing made of
high-quality plastic with degree of protection IP 67. Thanks to the compact design, measurements
at low water fittings are very convenient. The device is tested as per TÜV report S1217-00/15. The
measured data is transmitted to the BlueLine measuring instruments Bluelyzer ST, Eurolyzer STx,
Multilyzer STe/STx, series S4600 ST, TMD 9 or to a mobile device via the integrated Bluetooth®
Smart interface.

Technical Dimensions Resolution


specifications W x H x D: 71 x 158 x 97 mm Flow rate: 0.1 l/min
Temperature: 0.1 °C
Weight
370 g T90
10 s (≤ V0.3.0)
Further Interface
information:
Bluetooth® Smart Sensor
Capacitance sensor
Measuring ranges
PT 1000
Flow rate: 1.5 / 17.5 l/min
Temperature: 5 / 100 °C Sampling rate
1 sec
Accuracy
Flow rate: ± 0.3 l/min or ± 5 % of measured value
www.flowtemp.st Temperature: ± 2 °C or ± 3 % of measured value

DG: H, PG: 4 Part no. Price €


Flow rate/temperature measuring instrument FlowTemp® ST 502001

www.afriso.com 69
CAPBs ® sets Tightness test

CAPBs® set
for tightness test
DPK 60-6 sens

Starter set for professional tightness tests with the


wireless CAPBs® sensor modules

CAPBs® sensor module for pressure (6 bar) for


CAPBs®-enabled measuring instruments of the BlueLine
series with Bluetooth® Smart technology

Robust, modular system case M "DPK", suitable for


box and shelf system Sortimo-BOXX

4
Application For pressure tests as per DVGW worksheet G600. Suitable for tightness tests (150 mbar) and
load tests (1 bar) on gas pipes and for checking the connection and flow pressure as well as the
pressure loss. Can also be used for tightness tests (150 mbar) and strength tests (3 bar) on
drinking water pipes as per ZVSHK (German Central Association of the HVAC Industry). Ideal for
acceptance tests of heating system pipes, solar system pipes, underfloor heating systems, liquid
gas pipes and oil pipes.

Scope of delivery ■■ Sensor module Pressure CAPBs® sens


PS 40, 6 bar, connection Ø 8 mm
■■ Pressure test valve with quick-action coupling and high-precision adjustment valve

■■ Hand-operated bulb pump with valve and connecting hose


Base handle BG 10

■■ 2 conical test plugs for pipe diameter ¾" – 1¼"

with plug-in nipple


■■ Y connector (2 x quick-action coupling/1 x plug-in nipple)

■■ Connection hoses with plug-in nipple and quick-action coupling

■■ Modular system case M "DPK"

DG: H, PG: 4 Part no. Price €


Base handle CAPBs BG 10
®
M091000017
Leak test set DPK 60-6 sens with sensor module
Pressure in system case M "DPK", optional base
560005
handle, prepared for CAPBs®-enabled BlueLine
measuring instruments

70 www.afriso.com
Tightness test CAPBs ® sets

CAPBs® set
evaluation of
serviceability
DPK 60-7 sens

Modular extension kit for DPK 60-6 ST and DPK 60-6 sens

Barometric pressure determination for highly accurate measu-


red values
Base handle BG 10

4
Application Evaluation of serviceability/determination of amount of gas leakage at gas lines as per TRGI.
Ideal as compact extension kit for leak test sets DPK 60-6 ST und DPK 60-6 sens.

Description DVGW-certified sensor module pressure CAPBs® sens PS 33 (2 bar) with connection hose, manual
bulb pump and syringe for determining the volume, in system case S. With barometric pressure deter-
mination for compensation of fluctuating barometric pressure during measurements and with tempera-
ture compensation. Certified for measuring tasks as per DVGW TRGI.

Technical data Dimensions Accuracy


W x H x D 42 x 74 x 35 mm ±0.3 mbar, 0.5 % displayed value, ±1 digit
Interface Resolution
Bluetooth® Smart 0.1 mbar, (< 999.99), 1 mbar (> 1,000)
Measuring range Hose connection
–1/+2 bar Ø 8 mm

Scope of delivery ■■ Sensor module pressure CAPBs® sens PS 33, 2 bar, connection 8 mm
■■ Syringe for test volume
■■ hand-operated bulb pump

■■ System case S

DG: H, PG: 4 Part no. Price €


Base handle CAPBs® BG 10 M091000017
CAPBs® set evaluation of serviceability
560012
DPK 60-7 sens

www.afriso.com 71
CAPBs ® sets Water/heating

Modular extension sets


in system case S

Base handle BG 10

Base handle BG 10
CAPBs® CAPBs® set
water set ADS-WS heating system
check 2.0

Application Water set for pressure tests at water pipes with Sensor module pressure/temperature CAPBs®
test medium water. Consisting of pressure sens FP 10 with Pitot tube and surface tempera-
transmitter CAPBs® sens PT 70 (25 bar), test ture probe in system case S for measurement of
plug ½" with plug-in nipple, T connector with the flow rate and determination of the temperature
2 quick-action couplings and adapter for in the residual core flow of the flue gas line. The
compressor connection in system case S. measured data is used to calculate the ventilation
loss. If the channel cross section is known, it is
possible to calculate the volume flow. The meas-
urement results of the surface temperature probe
serve as the basis for calculating the surface loss
of the heat generator.

DG: H, PG: 4 Part no. Price €


Base handle CAPBs® BG 10 M091000017
CAPBs® water set ADS-WS sens 560008
CAPBs® set heating system check sens 560009

72 www.afriso.com
4 Pa/heating CAPBs ® set

Modular extension sets


in system case S

CAPBs®

Base handle BG 10

Base handle BG 10
CAPBs set ®
combination set
4 Pa test 4 Pa test and heating
system check 2.0

Application If multiple heat systems using indoor intake air For performing 4 Pa test and heating system
and ventilation systems are operated in a check 2.0. Combination set consisting of sensor
closed space, this can result in a hazardous module pressure/temperature CAPBs® sens
low pressure. The 4 Pa test set, consisting of FP 10 with hose kit, Pitot tube and surface
the sensor module pressure/temperature temperature probe in system case S.
CAPBs® sens FP 10 with hose kit in the sys-
tem case S, it is possible to check and docu-
ment the low pressure limit value of 4 Pa.

DG: H, PG: 4 Part no. Price €


Base handle CAPBs® BG 10 M091000017
CAPBs® set 4 Pa sens 560010
CAPBs® set 4 Pa with heating system check sens 560011

www.afriso.com 73
Measuring instrument for CAPBs® Overview

The application counts.


BlueLine measuring instruments for CAPBs®

Flue gas analyser Flue gas analyser


4 BLUELYZER ST EUROLYZER STx
Flue gas analysis, pressure measurement All-in-one: Flue gas analysis, (differential)
40 mbar (draft) and (differential) temperature pressure measurement 150 mbar and
measurement with a single instrument (differential) temperature measurement

microSD card Max. 16 GB Max. 16 GB


Flue gas measurement • •

Draft/chimney draft measurement • •


Application

Pressure measurement • •

Differential pressure measurement •

Vacuum measurement • •

Temperature measurement • •

Pitot measurement •

Particulate matter measurement

■■ The world's smallest, fully-featured HVAC ■■ ECO sensor: Lead-free O2 sensor with
all-rounder with TFT colour display long service life and optimised calibration
phase, short response time, resistant to
■■ Program as per German Federal Immission biogenous fuels
Act with calculation of qA mean value
■■ 5 years warranty on O2 measuring cell
■■ CO ambient measurement with two freely
adjustable alarm thresholds ■■ H
2
-compensated CO cell
(measuring range up to 10,000 ppm)
■■ Fully-fledgedtemperature measurement
program, differential temperatures (e.g. ■■ NO cell can be retrofitted
flow/return) can also be determined

74 www.afriso.com
Overview Measuring instrument for CAPBs®

Flue gas analyser Pressure measuring Temperature measuring


MULTILYZER STx instrument S4600 ST instrument TMD 9
All-in-one: Flue gas analysis, (differential) For measuring pressure, vacuum and For temperature measurement on surfaces,
pressure measurement 150 mbar and differential pressure in liquids, soft plastic media or in air and
(differential) temperature measurement gases.

Max. 32 GB Max. 16 GB Max. 16 GB


• •

• •

• •

• •

• •

• Max. 150 mbar


(in conjunction with STM 225)

■■ ECO sensor: Lead-free O2 sensor with ■■ Six (differential) pressure measuring ranges ■■ Shortresponse time for measurements at
long service life and optimised calibration cycles of a second
■■ Barometric
pressure sensor and temper-
phase, short response time, resistant to
biogenous fuels ature compensation for highly accurate ■■ Multifunctional
use of temperature probes
measured value with "type K connection"
■■ 7years full warranty in connection with a
■■ Also available as measuring instrument for ■■ Verylong battery life due to lithium-
service contract
ultra-low pressure (20 mbar) and version ion battery (up to 35 h)
■■ Sensor equipment with a combination of for very high pressure (18 bar)
■■ Data logger included
up to six measuring cells: O2, COH2, NO,
SO2, NO2 and CO40,000 ■■ Suitable
for differential temperature
measurements

www.afriso.com 75
BlueAir-STx

HMG 10

Flowtemp
FLOW MEASUREMENT

Handheld measuring instruments


for adjustment and balancing of heating,
cooling and ventilation systems

AIR VELOCITY

Air velocity and air mass flow meter B


 lueAir-STx 78

HYDRAULIC BALANCING

Overview hydraulic balancing 82

Measuring instrument for hydraulic balancing HMG 01 86

Measuring instrument for hydraulic balancing HMG 10 87

VOLUME FLOW

Flow rate measuring instrument F


 lowTemp 88

77
Flow measurement Air velocity

Air velocity and air mass flow meter


Product highlight BlueAir-STx

Universal

Measuring and adjusting ventilation systems:


air velocity, air flow, temperature and humidity.

Accurate

High-performance probes for accurate


measurements in daily use.

Intuitive

Intuitive operation, large TFT colour display


(W x H: 45 x 60 mm) and well-structured
measurement programs.

Individual

Measurement of current value or interval measurement.


5

Perseverant

Powerful lithium-ion battery for up to 40 hours


of operation.

Proven

Infrared interface for IR printer.

Reliable

Fully automatic device check, manual and automatic


zero calibration during program start.

78 www.afriso.com
Air velocity Flow measurement

Interoperable

App EuroSoft mobile for graphical visualisation of the


measurement results, transmission of values to
smartphones/tablets and as e-mails (HTML format).

Independent

microSD card for system-independent storage of


measurement logs (HTML format).

User-friendly

Automatic probe detection when probe is connected,


ergonomic, modern design.

Clear

Simultaneous display of 3 or 4 measured values.

Innovative

Bluetooth® Smart interface on board: Power-saving


data transmission to Bluetooth® printers and mobile
devices

Smart

Optional data logger function (1-999 seconds, interval


freely selectable) for long-term measurement or
diagnostics. Data output in XML format for flexible
further processing with standard software applications
such as MS Excel.

www.afriso.com 79
Flow measurement Air velocity

AIR VELOCITY

BlueAir-STx

Clearly structured measurement programs,


simultaneous display of 4 measured values

Measurement of current value

Automatic probe detection when probe is connected

Range of high-performance probes for accurate meas-


Picture shows original size

urements in daily use

Evaluation function displays minimum, maximum and


mean values

Calculation of air volume after you have entered the


channel cross section

Large TFT colour display (W x H: 45 x 60 mm)

Fully automatic device check, manual and automatic


zero calibration during program start

EuroSoft
mobile app

Application Modular, multi-channel instrument for, flow rate, temperature and


humidity. Ideal for checking and setting the air velocity of ventilation
and air conditioning systems and fans and for measurements in
ventilation and exhaust ducts.

80 www.afriso.com
Air velocity Flow measurement

Bottom Top

1 3

2 4 5

1 Mini USB connection for power supply/charger 3 MicroSD card slot 5 Connection temperature and

2 Signal unit (speaker) 4 Connection vane probes humidity sensor

Technical Vane probe Vane probe Vane probe Temperature and


specifications BlueAir-STx BlueAir-STx BlueAir-STx humidity sensor
probe range Junior Micro Junior Mini Junior Macro TFS-BA/BlueAir-STx
Air velocity (nom.) 0.6 to 20 m/s 0.4 to 20 m/s 0.2 to 20 m/s -
Air velocity (max.) 0.7 to 40 m/s 0.5 to 40 m/s 0.3 to 40 m/s -
Humidity - - - 10 to 90 % r.h.
Temperature - - - -20 / +80 °C
Humidity: 0.1 % r.h.
Resolution 0.01 m/s 0.01 m/s 0.01 m/s
Temperature: 0.1 °C
Humidity:
± 2.0 % fs ± 1.0 % fs ± 1.0 % fs ± 2.3 % r.h. at 10 to 90 % r.h.
Accuracy
± 5.0 % rdg ± 3.0 % rdg ± 3.0 % rdg Temperature:
± 0.8 °C at 0 / 40 °C
Humidity: ± 0.2% r.h.
Reproducibility - - -
Temperature: ± 0.2 °C
Operating temperature
-20 / +140 °C -20 / +140 °C -20 / +140 °C -40 / +80 °C
range medium
Sensor size Ø 11 x 15 mm Ø 22 x 28 mm Ø 85 x 80 mm Ø 15 x 48 mm
Probe length 165 mm 175 mm 235 mm 30 mm
Cable length 1.5 m 1.5 m 1.5 m -

Technical Operating temperature range Hours of operation


specifications Operation: 0 / 40 °C Up to 20 hours in normal mode
Storage: -20 / +50 °C Up to 30 hours in auto mode 5
Up to 40 hours in eco mode
Dimensions
W x H x D: 66 x 143 x 37 mm, Data memory
with protective sleeve 1–999 seconds, interval freely selectable
Weight Data logger
Approx. 220 g microSD card
Degree of protection Interfaces
IP 40 Infrared, Bluetooth® Smart, QR code generator,
microSD card slot
Display
TFT colour display: 2.8", W x H: 45 x 60 mm
i Resolution: 240 x 320 pixels
See chapter 7 for options
Supply voltage
and accessories.
Lithium-ion battery (3.6 V/1,800 mAh)
USB-A socket,

with USB card


MicroSD card
power supply

Junior Macro
Junior Micro
BlueAir-STx,

Vane probe

Vane probe

Vane probe
BlueAir-STx

BlueAir-STx
Junior Mini
unit NTE 5

Sets
reader

Case

DG: H, PG: 4 Part no. Price €


BlueAir-STx measuring instrument • 560013
BlueAir-STx set 1 • • • 560014
BlueAir-STx set 2 • • • 560015
BlueAir-STx set 3 • • • 560016

www.afriso.com 81
Flow measurement Hydraulic Balancing

Hydraulic balancing: Highest efficiency,


maximum energy saving and comfort

Has your heating system been balanced?


On its way to the radiators and back to the boiler, the hot water hot water. Typical countermeasures such as increased pump
flow always chooses the path of least resistance. Due to this natu- capacities or higher flow temperatures do not improve this situa-
ral law, in heating systems without hydraulic balancing radiators tion, but rather amplify the negative effects. Such systems con-
further away from the pump are supplied with insufficient amounts sume much more energy than necessary without providing the
of hot water while radiators close to the pump receive too much expected convenience.

Consequences of lack of
hydraulic balancing:
Uneven heat release
Heating times of rooms/apartments differ
Thermostat valves cannot properly control the room
temperature
Limited frost protection
Disturbing flow noise in valves and pipes
Excessive power consumption due to oversized and/or
incorrectly set circulation pumps
High losses when the heating system starts or is not used
Low efficiency of condensing systems: Excessive flow through
radiators close to the pump leads to high return temperatures
and reduces the condensation effect (energy recovery during
condensation of the flue gas)

What is hydraulic balancing?


Hydraulic balancing ensures optimum distribution of the water in for all radiators. This forces the hot water to flow through the sys-
5 the heating system. Based on the actual heat requirements of the tem exactly as required. The right method and suitable compo-
building, the circulation pump, the control (flow temperature), the nents allow for considerable savings. In individual cases, this may
fittings and the valves are adjusted to change the volume flow in amount to as much as 15% and more of the annual heating
the pipes in such a way as to obtain the required flow resistance capacity.

System without hydraulic balancing System with hydraulic balancing

Low resistance = high Flow limitation for


flow rate balancing
Copyright: VdZ – Forum für Enegieeffizienz in der Gebäudetechnik e.V.

Copyright: VdZ – Forum für Enegieeffizienz in der Gebäudetechnik e.V.

High resistance =
low flow rate

Pump

Adjustable thermostat valve with measuring function

82 www.afriso.com
Hydraulic Balancing Flow measurement

Advantages – your benefits


Convenience: Rooms are heated evenly
Radiators respond quickly to new thermostat valve settings
Maximum frost protection safety
No flow noise in the heating system
Heating system/pump operate with maximum efficiency to
save energy
Increased system reliability
Improved energetic quality of the building
Reduced energy consumption saves money and protects
the environment due to less emission

Legal obligations hydraulic balancing


In Germany, hydraulic balancing is mandatory, as stipulated by the
German VOB, part C (German Construction Contract Procedures),
DIN 18380 as well as the German EnEV (Energy Savings Ordinance).

www.afriso.com 83
Flow measurement Hydraulic Balancing

Fast and easy hydraulic balancing with


AFRISO components

In existing buildings, hydraulic balancing often involves a lot of esti- AFRISO offers two systems for hydraulic balancing. In both cases,
mating and approximation since precise information on the pipe the heating system expert adjusts the heat distribution directly at
system is unavailable. In old buildings, the lengths and diameters of each radiator by limiting the amount of hot water at the adjustable
pipes are often not sufficiently documented, the pipe systems have thermostat valves - without additional adjustment fittings. The deci-
been changed or there are different levels of renovation. In such sion as to which system is most suitable for a given building
cases, a fundament prerequisite is missing. depends on a variety of factors and requirements:

Automatic hydraulic balancing for the HVAC professional

The system Vario-DP


Pre-adjustable thermostat valves Vario-DP with patented dynamic valve insert
for automatic limitation of the water volume set at the valve. Vario-DP controls
the water volume independent of pressure variation in the heating system.
Therefore, Vario-DP ensures that the right water volume is always supplied to
the radiator, regardless of the number of open or closed thermostat valves in
the system.

Your benefits:

Automatic control of water volume


Adjusted flow is not exceeded
Building type: Primarily for single-/two-family homes, residential buildings
Fast hydraulic balancing without measuring instrument
Wide range of products, easy planning
High reserve due to wide adjustment range up to 340 l/h
Geometry of valve insert provides protection against unwanted pollution,
5 failure due to blocking is practically impossible

Valve range Vario-DP


The control membrane is installed directly in the valve insert and
the valve spindle is used as the pressure sensor – therefore, there
are no additional control components which might be subject to
pollution. The valve operates with a standard valve gasket and
does not require additional dirt filters.

84 www.afriso.com
Hydraulic Balancing Flow measurement

Hydraulic balancing with measurement function for the HVAC system planner

The triple-stage VarioQ system


The pre-adjustable VarioQ thermostat valves with measurement func-
tion allow for an even more precise approach to hydraulic balancing.
The triple-stage system optimises the heating system on the basis of
calculation, measurement and adjustment. Thanks to an integrated,
fixed measuring unit, it is possible to directly measure the current flow
and adjust the calculated water volume at each radiator valve or at the
lockshield valve.

Your benefits:

Precise measurement and adjustment of the required water


volume per radiator.
Building type: Primarily for public buildings, schools, administration
buildings and generally for larger heating systems
Reliable procedure for larger and complex heating systems
Measurement option at the valve for documentable and
verifiable adjustment
Time and cost savings: Neither dynamic valves nor
line fittings are required
Up to 80 % savings with regard to pump capacity
as compared to automatically balanced heating systems
Further optimisation potential due to, for example, fewer
burner starts or increased condensing effect

Valve range VarioQ


The fixed measuring unit of VarioQ allows for the precise
adjustment of the water volume at the valve of the radiator.
The pre-adjustable thermostat valves feature a fixed,
5
calibrated measuring unit for adjustment of the volume
flow directly at the valve.

Measuring instrument HMG 10


Calculation software VarioQCalc
HMG 10 receives its data from VarioQCalc
The easy-to-use software determines the via a USB interface. The measuring instru-
required optimum water volume as well as the ment measures the flow rate in litres per
VarioQ valves for each radiator. Only the flow hour and the water volume can be easily
temperature of the system, the radiator capacity set at the valve without conversion.
and the heat requirements of the rooms to be In addition, all standard measuring valves
heated are needed as a basis for the calculation. and line fittings are stored and can be
Parameters and estimated values of the pipe intuitively selected via the graphical user
system do not have to be considered. interface.

www.afriso.com 85
Flow measurement Hydraulic Balancing

Handheld measuring
instrument for hydraulic
balancing HMG 01

 ydraulic balancing directly at the radiator


H
with VarioQ valves

Simple measuring instrument for line fittings

Measurement/check of differential pressure and flow rate

For heating circuit water and media of other densities

Application For differential pressure measurement and flow rate adjustment in heating and refrigerating systems
during hydraulic balancing. To be used in conjunction with VarioQ thermostat valves and combination
blocks. If VarioQ valves are used, hydraulic balancing can be done directly at the radiator. It is neither
necessary to know the pipeline system nor to perform complex calculations.

Description HMG 01 is a simple, lightweight handheld measuring instrument with a display for visualisation of the
5 results of measurements. The flow coefficients of the valves with measuring function can be manually
set via the keypad (valve bodies VarioQ S, M, L are stored in the memory); the flow rate at the valve
can be displayed and the water volume can be easily set at the VarioQ valve without conversion. The
measured flow rate and pressure values can be displayed in various units. HMG 01 features an intuitive
calibration function for zero calibration.

Technical Measuring range Supply voltage


specifications 0/1,000 kPa / 0/10 bar 2 x 1.2 V AA batteries (rechargeable)
Max. overpressure Options
- side: 1,000 kPa / 10 bar ■■ Hose kit for line fittings

+ side: 1,500 kPa / 15 bar ■■ Measuring needles for line fittings

Operating temperature range Scope of delivery


Ambient/storage: -5 /+50 °C Measuring instrument with calibration report,
Medium: -5 /+90 °C 2 x batteries, 1 pair of measuring hoses for
connection of VarioQ valves, adapters and
Weight
accessories for connection to the system to be
380 g
balanced, mounting tools
Dimensions
W x H x D 94 x 218 x 40 mm
Display DG: H, PG: 4 Part no. Price €
Backlit display
HMG 01 68785
128 x 64 Pixel
Accessories for line fittings
Connection
2 x plug connection (red/blue) Measuring needles 480 000.805
Hose kit 480 000.801

86 www.afriso.com
Hydraulic Balancing Flow measurement

Measuring instrument
for hydraulic balancing
HMG 10

 ightning-fast hydraulic balancing at the radiator


L
with VarioQ valves

 oftware-supported measurement/check of differential


S
pressure and flow rate

 haracteristic curves of standard line valves and radiator


C
valves stored in the software

 or heating circuit water


F
and media of other
densities

Application For differential pressure measurement and flow rate adjustment in heating and refrigerating systems
during hydraulic balancing. To be used with VarioQ thermostat valves, VarioQ combination blocks or
standard line fittings with measuring function.

Description HMG 10 is an ergonomic, lightweight handheld measuring instrument. A large, backlit colour display
allows for convenient visualisation of all measurement results. All standard measuring valves are
stored and can be intuitively selected via the graphical user interface. The measuring instrument 5
measures the flow rate in litres per hour and the water volume can be easily set at the VarioQ valve
without conversion. HMG 10 uses all data and calculation results from VarioQCalc and returns all
measured and adjusted values of the balancing procedure for documentation purposes. In addition,
projects can be defined with the PC software as required and then transferred to the memory of
HMG 10. A mini USB port is provided for communication and battery charging.

Technical Measuring range Display


specifications 0/1,000 kPa / 0/10 bar Backlit colour display
240 x 320 pixels
Max. overpressure
1,200 kPa / 12 bar Connection
2 x plug connection (red/blue)
Operating temperature range
Ambient/storage: -5 /+50 °C Supply voltage
Medium: -5 /+90 °C Lithium-ion battery 950 mAh
Hours of operation Scope of delivery
Max. 12 hours Measuring instrument with calibration report, USB
charging adapter, 2 pairs of measuring hoses
Weight
for connection of VarioQ valves and line fittings,
420 g
adapters and accessories for connection to the
Dimensions system to be balanced, mounting tools, USB data
W x H x D 80 x 180 x 52 mm cable, USB flash drive with PC software

DG: H, PG: 4 Part no. Price €


HMG 10 68794
Measuring needles for VarioQ valves (2 pieces) 410 010.804

www.afriso.com 87
Flow measurement Volume flow

Volume flow/temperature
measuring instrument
FlowTemp

Fast, easy determination of the temperature per water volume


Also
Selection of measuring range for the volume flow measuring
available by means of a disc with different holes
as
CAPBs®

Application For checking and adjusting water heaters. FLOWTEMP is held under an open water tap and
indicates the water temperature reached at the corresponding flow rate.

Technical Measuring ranges Scope of delivery


5 specifications 1.6 up to 4 l/min
4 up to 8 l/min
Instrument with robust plastic enclosure
to protect against dirt, impact and shock
8 up to 16 l/min

DG: H, PG: 4 Part no. Price €


Measuring instrument for volume flow and temperature Flowtemp 569790

88 www.afriso.com
Options/accessories Flow measurement

Options and accessories


Vane probes for BlueAir-ST®

Junior Macro
Part no. 524320

Junior Micro
Part no. 524318

Junior Mini
Part no. 524319
5

Thermal printer EUROprinter-IR


Compact printer with four magnets at the
back for hands-free operation. Infrared
interface for easy connection of all
BlueLine series measuring instruments.
Documents all measured results on
paper for official purposes – anywhere
Part no. 522394

Option data logger


Data logging once per second during
measurements (XML format)
Part no. 511010

www.afriso.com 89
Tester for
expansion vessels

Digital service
pressure gauge

Level sensor tester


INSPECTION

Inspection and testing equipment


for maintenance and service

TESTERS

Pressure gauge RF 50 PPSfor oil burner pumps 92

Test and refill set P


 NG, filler for expansion vessels 93

Testers P
 GA, PGW, PGW-10-Set for pressure tests of expansion vessels, tanks, water pipes and tyres 94

Level sensor tester G


 PG 01 96

TESTERS

Level sensor testerGPR 4 97

Anode tester A
 T1 97

91
Inspection Testers

Pressure gauge RF 50 PPS


for pump test set

Description Pressure gauge for checking the pressure and suction capacity at oil burner pumps. Preferably
in conjunction with standard pump test valve with G1/8.

RF 50 PPS D 101 – RF 50 PPS D 601 –


without glycerine filling with glycerine filling

Technical Housing diameter Housing diameter


specifications 50 mm 50 mm
Connection Connection
G1/8B bottom without sealing plug G1/8B bottom without sealing plug
Housing Housing
Plastic Plastic with crimped bezel
Window Window
Plastic Plastic
Accuracy class (EN 837-1/6) Accuracy class (EN 837-1/6)
1.6 1.6

DG: M, PG: 2 Range Part no. Price €


RF 50 PPS D 101 – without glycerine filling -1/0 bar 63991
RF 50 PPS D 101 – without glycerine filling 0/25 bar 63995
RF 50 PPS D 601 – with glycerine filling -1/0 bar 67165
RF 50 PPS D 601 – with glycerine filling 0/25 bar 67166

92 www.afriso.com
Testers Inspection

Test and refill sets PNG,


vessel filler

PNG-1 / PNG-3 PNG-2 Vessel filler

Application For testing and adjusting the For testing and adjusting the Vessel filler for increasing the
pressure cushion of diaphragm pressure cushion of diaphragm pressure cushion in expansion
expansion vessels of heating expansion vessels of heating vessels.
systems and oil supply systems. and oil supply systems, specially
for systems with test valves
which are not easily accessible.

Description The test and refill set consisting Test and refill set consisting of a Suitable for PNG-1, PNG-2 and
of a 60 cm long, flexible filling rigid, 200 mm long test lance PNG-3. With corrosion protec-
hose with union nut Vg8 for the with test head for pressing tion component, not flammable.
test valve at the expansion ves- against the test valve of the
sel and a ball valve with 7/16-28 expansion vessel and a ball
UNEF thread for vessel filler cyl- valve with 7/16-28 UNEF thread
inder and a test pressure gauge for vessel filler cylinder and a
Ø 40 mm. test pressure gauge Ø 40 mm,
The vessel filler cylinder is not 0/4 bar. During testing and refill-
included. ing, the fitting is pressed against
the test valve.

Technical Ranges Ranges Connection thread


specifications PNG-1: 0/4 bar 0/4 bar 7/16-28 UNEF
PNG-3: 0/10 bar
Accuracy class Table of Contents
Accuracy class 1.6 400 ml
1.6
Scope of delivery
6
PNG-2 including vessel filler
cylinder
and plastic case

DG: H PG Part no. Price €


Test and refill set PNG-1, 0/4 bar 2 39616
Test and refill set PNG-3, 0/10 bar 2 39637
Vessel filler cylinder, 400 ml 1 39633
Test and refill set PNG-2 2 39634
Spare case of PNG-2 1 39635

www.afriso.com 93
Inspection Testers

Testers PGA

Tester Test set


PGA PGA-4-Set

Application For pressure tests of expansion vessels, tanks For pressure tests of expansion vessels, tanks
and tyres. and tyres.

Description Robust, very accurate pressure gauge in Robust, very accurate pressure gauge in alumini-
aluminium housing with ring for zero correction. um housing with ring for zero correction.
Measuring range 0/4 bar. With 45° adapter Measuring range 0/4 bar. With three adapters for
for use even if space is limited. car valves which are also used for expansion
vessels. The three adapters (straight, 45°, 90°)
allow for usage even if space is limited. Plastic
case with insert included in scope of delivery.

DG: H, PG: 3 Part no. Price €


Tester PGA, 0/4 bar 39615
Test set PGA-4-Set 39614

94 www.afriso.com
Testers Inspection

Testers PGW

Tester Test set


PGW PGW-10-Set

Application For measuring the tyre pressure For pressure tests of water pipes, tanks and tyres.

Description Robust pressure gauge in aluminium housing Robust, very accurate pressure gauge in
with ring for zero correction. Measuring range aluminium housing with ring for zero correction.
0/10 bar, with adapter for car valves. Also Measuring range 0/10 bar.
suitable for testing water pressure when used With adaptor for hose tap ½" (thread G¾), aerator
in conjunction with adapters from PGW-10-Set. M24 x 1 female thread and
M22 x 1 male thread.
Scope of delivery includes plastic case with
insert and a connector piece for car valves.

DG: H, PG: 3 Part no. Price €


Tester PGW, 0/10 bar 39618
Test set PGW-10-Set 39617

www.afriso.com 95
Inspection Testers

Level sensor tester GPG 01

■■ Intuitive operation by means of "step by step" instructions


■■ For all level sensors as per EN 13616 design B1 (formerly TRbF 511)
■■ For liquids with a flash point of > 55 °C
such as fuel oil, diesel and other liquid fuels or oils
■■ High-resolution TFT colour display and powerful lithium-ion battery
for optimum readings and many measurements
■■ Robust protective sleeve with magnet for convenient,
hands-free operation

Application For full testing of level sensors which are not used in hazardous areas/potentially explosive atmos-
pheres. It is possible to perform a simple electrical function test with the level sensor installed as well
as a wet test with the level sensor uninstalled.

Description Modern, robust housing with high-resolution TFT colour display and foil keypad with four keys and
On/Off button. A 1.2 m connection cable with a coupling socket 903 for plugging in the level sensor is
mounted at the top. A mini USB port for the power supply unit/battery charger is located at the bot-
tom. The electrical function test displays the heat-up time in seconds and filling release. When a wet
test is performed, the switch off time in seconds after submersion in liquid is indicated. At the end of
the test, the full test result is displayed in the form of a summary. In the case of error messages and
malfunctions, the display colour changes to red and a corresponding text is shown. If the device is not
in use, it is switched off automatically; the charging function remains active.

Technical Operating temperature range Connection level sensor


specifications Ambient: 0/40 °C 1.2 m connection cable with coupling socket 903
Storage: -20/+50 °C
Display
Hours of operation TFT colour display, 2.8"
Max. 38 hours W x H: 45 x 60 mm
Weight Supply voltage
Approx. 360 g (device) Lithium-ion battery (3.6 V/1,800 mAh)
or power supply unit (USB)
Dimensions
W x H x D: 66 x 143 x 37 mm Scope of delivery
6 (without connection cable) Tester with coupling socket 903,
USB power supply unit, mini USB cable,
a protective sleeve with magnet, case,
­instructions.
Level sensor testers
with connector 903 –
suitable for all level sensor
fittings.

i
See the catalogue
DOMESTIC
TECHNOLOGY for the
complete range of level DG: G, PG: 4 Part no. Price €
sensors and anodes. Level sensor tester GPG 01 46200

96 www.afriso.com
Testers Inspection

Level sensor tester GPR 4,


Anode tester AT1

Level sensor tester Anode tester AT1


GPR 4

Application For fast and easy electrical function tests of level Tester for consumption check of anode I or
sensors. For use with storage tanks for fuel oils isolated standard sacrificial anodes.
and diesel fuels. Not permitted for use in hazard-
ous areas and not for level sensors which are
installed in tanks containing hazardous media.

Description Simple level sensor tester with connector, suitable ■■ Handheld tester with 4-level LED indication
for all level sensor fittings. A signal lamp indicates ■■ Fast and easy indication of the condition
function or error. Battery-operated. Delivery with of the anode
■■ Reliability of the water heater due to preventive
level sensor connection fitting, also suitable for
level sensor with brass fitting. maintenance – consumed anodes are replaced
in good time

Technical
specifications Level sensor testers with connector 903 –
suitable for all level sensor fittings.

i
See the catalogue
DOMESTIC
TECHNOLOGY for the
complete range of level
sensors and anodes.

DG: H, PG: 4 Part no. Price €


Level sensor tester GPR 4 62301
Anode tester AT1 for anode I 69842

www.afriso.com 97
Flue gas probes

FlowTemp ST

live

Printer

Mobile apps

Modular system cases


ACCESSORIES

Accessories and options


for the BlueLine series

PROBES

Modular probe system, universal flue gas probe plug-in units 100

Flue gas probe compact AKS-K, analysis lines, pitot tubes 101

Gas sampling probe P


 SP 4000 101

Probes for dust measuring instrument STM 225 101

Condensate filter cartridges KFP 102

Probes for air velocity meters B


 lueAir-STx 103

Probes and accessories for moisture measuring instruments M


 FM 22 103

Temperature probes TFB, clamping cones KLK 104

FOR ALL BLUELINE MEASURING INSTRUMENTS AND CAPBs ®

Memory card microSD-HC, database memory, data logger 105

Options, power supply units, charging cables 105

Connection kits: ASS-DP, ASS-TS, ASS-HD, SLS 106

Thermo Printer EUROprinter-IR 106

Soot pumps RSP 106

Cases, transport bags and modular system cases 107 7

TIGHTNESS TEST

Leak test sets DPK 54, gauges for DPK 54, foot-operated pump FSP-L, single pipe union connector 109

Pressure test valve ADV 2, test plugs, adapters 110

COMMUNICATION

App E
 uroSoft live 111

EuroSoft mobile – Evaluation software and App for BlueLine measuring instruments 112

MAINTENANCE/WARRANTY

Maintenance contracts and extended warranty for flue gas analysers 115

ISO calibration 116

99
Accessories Probes

Probes for flue gas analysers

EUROLYZER STx
BLUELYZER ST

MULTILYZER
STe/STx
DG: H, PG: 4 Part Description Suitable for Part no. Price €

Modular probe system


Compensation line: 2.4 m,
with condensate filter cartridge KFP, • • 510921
Base handle with draft
AWS/B for
interchangeable
probes Compensation line: 5 m,
with condensate filter cartridge KFP, • • 510931
with draft

100 mm, Ø 8 mm • • 570084


180 mm, Ø 8 mm • • 570073
Interchangeable 300 mm, Ø 8 mm • • 570074
probe AWS-S
500 mm, Ø 8 mm • • 570075
suitable for base
handle 750 mm, Ø 8 mm • • 570076
1,000 mm, Ø 8 mm • • 570077
1,500 mm, Ø 8 mm • • 570078

Protective cap
AWS-SK for
570085
interchangeable
probes

Multi-hole probe
AWS-M Length-adjustable 60–170 mm,
• • 570080
suitable for base Ø 8 mm
handle

Annular gap For measurement of CO and


probe AWS-R O2 concentrations in the annular gap
• • 570083
suitable for base of double-walled chimney chimneys
handle of gas furnaces

Flexible probe
AWS-F
400 mm, Ø 9 mm • • 570079
suitable for base
handle

Flue gas probe plug-in units

7
Annular gap 2 m hose length
• • • 500236
probe RSO-UG with connection piece

Annular gap Universal,


• • • 570082
probe RSO-UA can be plugged onto all flue gas probes

Multi-hole probe
MSO-U
Length-adjustable 60–250 mm • • • 569580A
with connection
fitting

100 www.afriso.com
Probes Accessories

MULTILYZER STe/STx
EUROLYZER STx
BLUELYZER ST

S4600 ST

STM 225
DG: H, PG: 4 Part Description Suitable for Part no. Price €

Filters
Intermediate
filter NOX /SOX
With 1 refilling • • • 511064
for connection
Ø 8 mm

Refilling for interme-


diate 5 pieces 511066
filter

Flue gas probes, analysis lines, Pitot tubes


240 mm, with draft connection,
Flue gas probe
without condensate filter cartridge • 500246.5
compact AKS-K
KFP 2P

High temperature Up to 1,000 °C


fine gas combination Length 1,500 mm • • • 500273.1
probe AKS-HT Hose length 2.4 m

Gas sampling probe


• 568900
PSP 4000

Analysis line HL 4-3,


Length: 3 m • 569478
heated

Analysis line HL 4-5,


Length: 5 m • 569476
heated

Length: 2 m,
Sampling line
with compensation line
ENL-H 2, • 570205
and connection possibility
heated
for MULTILYZER NG, STe/STx

Sampling probe
280 mm, straight • 570202
ENS-G
7
Sampling probe
400 mm, straight • 570211
ENS-G

Sampling probe
300 mm, bent • 570203
ENS-W

Clamping cone For sampling probe ENS


• 523780
KLK-E 100 Ø 10 mm

Connection line withdrawal line


Connection kit
ENL-H2 and MULTILYZER STe/STx, • 500296
ASS-STM
with KFP

PTR-360,
• • • 500238
probe insertion depth 360 mm
Pitot tube
PTR-460,
• • • 500238.1
probe insertion depth 460 mm

www.afriso.com 101
Accessories Probes

Condensate filter cartridges KFP for


flue gas analysers

KFP KFP 2P

Condensate filter cartridge KFP (EUROLYZER STx, MULTILYZER STe/STx)

① ② ③ ④ ⑤

⑥ ⑦ ⑧ ⑨ ⑩ ⑪
① O ring 18 x 3 ③ Infiltec fine filter ⑤ O ring 23 x 2 ⑦ Teflon membrane ⑨ Centre piece KFP-MZ Inlet piece KFP-E
⑪ 
② Adapter KFP-Z ④ O-Ring 23 x 2 ⑥ Outlet piece KFP-A ⑧ Glass piston KFP-GL with logo ⑩ Glass piston KFP-GP with arrow

Condensate filter cartridge KFP 2P (BLUELYZER ST)


① ② ③ ③

④ ⑤ ⑥ ⑦ ⑧
① O ring 18 x 3 ③ O ring 23 x 2 ⑤ Teflon membrane ⑦ Glass piston KFP-GP with arrow
② Particle filter ④ Outlet piece KFP-A ⑥ Insert KFP-ESZ ⑧ Inlet piece KFP-E

DG: H, PG: 4 Part no. Price €


Condensate filter cartridge KFP 500190
Condensate filter cartridge KFP 2P 500192
Spare parts package gas treatment KFP:
500208
5 x Infiltec fine filter, 5 x Teflon membrane
7 Spare parts package gas treatment KFP 2P:
500214
5 x Infiltec fine filter, 5 x Teflon membrane

Spare parts use


KFP KFP 2P
Assortment of O rings KFP, sorted • • 511002
Inlet piece KFP-E • • 520594
Glass piston KFP-GP with arrow • • 520596
Centre piece KFP-MZ with cylinder • 521990
Intermediate piece KFP-Z • 520592
Outlet piece KFP-A • • 520591
Glass piston KFP-GL with logo • 521778
Teflon membrane, 10 pieces • • 511004
Infiltec fine filter, 5 pieces • 511003
Particle filter, 5 pieces • 511009
Insert KFP-ESZ with cylinder • 522183

102 www.afriso.com
Probes Accessories

Probes for BlueAir-STx and MFM 22

BlueAir-ST®/STx
MFM 22
Suitable
DG: H, PG: 4 for Part no. Price €

Probes for air velocity meters Blue Air


Temperature and humidity
Connector 8 pins • 511011
sensor TFS-BA

Sensor cable for TFS-BA Length: 1.8 m • 523511

Vane probe
• 524318
Junior Micro
Vane probe
• 524319
Junior Mini

Vane probe
• 524320
Junior Macro

Snap-on head
• 524360
Junior Micro

Snap-on head
• 524361
Junior Mini

Snap-on head
• 524362
Junior Macro

Extension rod VLS 180 Length: 180 mm • 523626

Extension rod VLS 300 Length: 300 mm • 523627

Telescopic extension rod


Length: 1 m • 523628
VLS 1000

Probes for moisture measuring instruments MFM 22

Measuring cable MFM Length: 1 m, with connector • 569083

Hammer electrode for log wood


• 569053
ELE-HE 20 TÜV approval with MFM 22

for log wood and moisture in


Ram electrode ELE-SE 10 • 569054
­construction materials

Handle ELE-G for ram electrode • 569049

Length: 430 mm, for wood chips and


Insertion electrode ELE-ST 50-1
pellets, with integrated temperature • 569026
TF with TÜV approval
probe, TÜV approval with MFM 22 7
Length: 1,100 mm, for wood chips and
Insertion electrode ELE-ST 50-2
pellets, with integrated temperature • 569027
TF with TÜV approval
probe, TÜV approval with MFM 22

Insertion probe TFB-ES 200 • 569020

Steel pins 12, 16, 23 mm 3 pieces each • 569081

Steel pins 40 mm 10 pieces • 569082

Deep electrode ELE-MS 110 for ram electrode, length: 300 mm • 569055

Brush electrodes
for moisture in construction materials • 569079
ELE-BE 110-1, 100 mm

Brush electrodes
for moisture in construction materials • 569058
ELE-BE 110-2, 300 mm

Conductive paste for brush


• 569078
electrode ELE-BE

www.afriso.com 103
Accessories Probes

Temperature probes

MULTILYZER STe/STx
EUROLYZER STx
for BlueLine series

BLUELYZER ST

TMD 7 / TMD 9
TM 6 / TM 7 /

CAPBs ®
MFM 22
DG: H, PG: 4 Part Description Suitable for Part no. Price €

Temperature probes TFB


Insertion probe
• • • • • • 569868
TFB-ES 600

Air, gas, liquid


probe • • • • • • 569867
TFB-LGF 900

Surface probe
• • • • • • 569866
TFB-OF 450

HT probe
700 mm • • • • • • 569853
TFB-HT 1150-1
HT probe
1,000 mm • • • • • • 569854
TFB-HT 1150-2

TFB-VL 600-1, 200 mm • • • • • • 500147


Combustion air
probe
TFB-VL 600-2, 290 mm • • • • • • 500147.2

Combustion air
probe With magnetic holder • • • • • • 500141
TFB-VL 100 M

Combustion air
With magnetic holder and rubber
probe • • • • • • 500141.1
cone
TFB-VL 100 MG

Surface probe
Temperature –40/+120°C • • • • • • 522991
TFB-OF 120

TFB-UL 50-1 • • • • • • 521844


Ambient air probe
TFB-UL 50-2 for MAXILYZER • • • • • • 500129

Clamp probe
Temperature –40/+120°C • • • • • • 511098
TFB-ZF 120


Plug socket yellow, 8 mm • • • 522171




Plug socket blue, 7 mm • • • 522172


7 

Clamping cones for the BlueLine series


DG: H, PG: 4 Part Description Part no. Price €

Clamping cone Made of PDM, hole Ø 5.0 mm,


522221
KLK-P 50 suitable for combustion air probe
Cones for probes

Clamping cone Made of Teflon, hole Ø 8.0 mm,


521637
KLK-T 80 suitable for flue gas combination probe

Clamping cone Made of stainless steel, hole Ø 8.0 mm,


520588
KLK-E 80 suitable for flue gas combination probe
Clamping cone Made of stainless steel, hole Ø 8.8 mm,
522918
KLK-E 88 suitable for EP-Check

Rubber cones Made of rubber, set of 3, Ø 5.0 mm,


568981
KLK-G suitable for combustion air probe

104 www.afriso.com
BlueLine Accessories

Options and accessories for

MULTILYZER STe/STx
EUROLYZER STx
the BlueLine series

BlueAir-ST®/STx
BLUELYZER ST

DPK 60-6 ST /
DPK 60-7 ST
S4600 ST
STM 225
GSP 1
DG: H, PG: 4 Suitable for Part no. Price €

Dust measuring instruments


10 cleaning swabs,
Cleaning kit 10 cleaning cloths, • 570210
2 cleaning brushes

O ring kit 9 pieces • 511028

Zero point filter • 523564

Flushing filter • 523565

Infiltec fine filter 10 pieces • 511003

Spring clip KP for STM 225 • 523947

Options
Device function MGF DL-S,
• • • • • • 511010
data logger

Extension of memory function, customer


Database memory • •* •* • • • 511030
database, customer information

Measuring instruments BlueLine series


MicroSD-HC card including USB 2.0 card reader • • • • • • 511035

Module USB-A
USB dongle for MULTILYZER STe
"BT-STM 225" • 500854
for communication with STM 225
MULTILYZER STe

Module USB-A Bluetooth® Smart dongle


• • • • • • 500856
for PC for PC application EuroSoft mobile

Charging cable
• • • • • • 523506
USB-A / mini USB

Power supply unit NTE 5 mini Car adapter for charging cable USB-A on
• • • • • • 523476
USB for car mini USB

Power supply unit NTE 5 USB-A • • • • • • 523493

Power supply unit NTE 6 • 522199


* Included in scope of delivery of measuring instrument.
7

www.afriso.com 105
Accessories BlueLine

Accessories for the BlueLine Series


DG: H, PG: 4 Part Description Part no. Price €
Hoses

Connection kit ASS-DP For handheld measuring instruments


for differential pressure measurement with connection Ø 7/8 mm and 500237
Length: 1 m Festo Ø 3 mm

Connection kit tank protection


ASS-TS Plug connection Ø 8 mm 569843
Length: 1 m

Connection kit high pressure


Plug connection hose (Ø 3 mm)
ASS-HD 500234
to G1/8, up to 15 bar
Length: 0.85 m

Hose kit SLS 4 Pa test Suitable for CAPBs®


500664
Length: 4 m 4 Pa-test

Adapter Festo connection


Adapter piece Ø 8 mm to Ø 3 mm for
1 piece 500677.1
BlueLine series pressure measuring
instruments

Thermal printers EUROprinter

Compact infrared printer with


Thermal printer EUROprinter-IR 522394
4 magnets at the back

Compact infrared printer with


Thermal printer EUROprinter-IR 4 magnets at the back.
523525
Bluetooth® Smart Interfaces: Infrared and
Bluetooth® Smart

Printer paper for EUROprinter


5 rolls 523374
Thermo
For official documentation,
Printer paper for EUROprinter self-adhesive, 522666
7 1 roll
Soot pumps RSP

With smoke spot number


Soot pump RSP-L comparison scale 569581
and filter paper (100 pieces)

Complete kit with sampling probe


(220 mm long) and plastic measuring
Soot pump RSP-XL head, smoke spot number comparison 569086
scale, threaded cone, cleaning agent,
filter paper (100 pieces)

Filter paper
200 pieces 568400
for soot pumps

Smoke spot number comparison


568300
scale

106 www.afriso.com
BlueLine Accessories

DG: H, PG: 4 Part Description Part no. Price €

Transport systems/cases

Plastic case universal For EUROLYZER and MULTILYZER 570106

Aluminium case For BlueAir-STx 511001

Plastic case MFM For MFM 22 569021

Transport bag For STM 225 570201

Hard-top case For EUROLYZER and MULTILYZER 523503

www.afriso.com 107
Accessories BlueLine

Modular system cases for BlueLine measuring


instruments and CAPBs ®

DG: H, PG: 4 Part no. Price €


System case L "DPK" With document compartment and high-grade foam inlay for
DPK 60-6 ST
7 1
Dimensions (W x H x D): 442 x 151 x 357 mm
500902
Weight: 2.2 kg
System case L "Gas analysis" With document compartment and high-grade foam inlay for
BLUELYZER ST, EUROLYZER STx, MULTILYZER STe/STx and
1 accessories 500900
Dimensions (W x H x D): 442 x 151 x 357 mm
Weight: 2.2 kg
System case M "DPK" With high-grade foam inlay for CAPBs® set DPK 60-6 sens
2 Dimensions (W x H x D): 367 x 72 x 316 mm 500904
Weight: 0.9 kg
System case M "CAPBs" With high-grade foam inlay for CAPBs® base handles
and sensor modules
2 500905
Dimensions (W x H x D): 367 x 72 x 316 mm
Weight: 0.9 kg
System case S With foam inlay
3 Dimensions (W x H x D): 260 x 63 x 155 mm 523976
Weight: 0.4 kg
Rack for system case M Dimensions (W x H x D): 442 x 100 x 342 mm
4 523977
Weight: 1.1 kg

108 www.afriso.com
Tightness test Accessories

Leak test set DPK 54,


accessories for DPK 60 series

Leak test set Foot-operated Single pipe union


DPK 54 pump FSP-L connector

Application For pressure tests of pipes of


liquid gas installations or for
tightness tests with air accord-
ing to the pressure measuring
principle and the visual inspec-
tion method.

Description Leak test set in sturdy wooden With check valve, quick-action With connection for single-line
case, consisting of: coupling gas meter. With plug-in nipple
■■ Test pressure gauge Ø 63 mm and 2.5 m connecting hose. suitable for all quick action cou-
with impact protection, pling systems of the DPK series.
Capacity per stroke
measuring range 0/2 bar with
200 cm³
expanded initial
graduation up to 250 mbar
■■ Connection piece

■■ Hand pump

■■ Various adapters

DG: H, PG: 3 Part no. Price €


Leak test set DPK 54 39540
Spare pressure gauge for DPK 54 39541
Connection piece for DPK 54 37303
Gauge (spare part) for DPK 60-5, 0.2/1.5 bar 569310
Gauge (spare part) for DPK 60-5, 6 bar 569311
Foot-operated pump FSP-L 563034
Hose for foot-operated pump FSP-L 563033
Single pipe union connector with plug-in connection, NW 5 500693

www.afriso.com 109
Accessories Tightness test

Accessories for DPK series

Pressure test valve ADV 2 Test plugs

Description Pressure test valve with quick-action coupling and Conical or cylindrical test plugs with plug-in nipple
high-precision adjustment valve for easy adjust- for quick-action coupling system and easy-to-
ment of the filling pressure. Suitable for all handle wing screw for standard pipe diameters
BlueLine series pressure measuring instruments ½", ¾", 1" and 1¼".
with hose connection Ø 8 mm.

DG: H, PG: 3 Part no. Price €


Pressure test valve ADV 2 with quick-action coupling and high-precision
500670
adjustment valve
Test plug conical ½" to ¾" with plug-in nipple 500678.1
Test plug conical ¾" to 1¼" with plug-in nipple 500678.2
Test plug cylindrical ½" with plug-in nipple 500678.3
Test plug cylindrical ¾" with plug-in nipple 500678.4
Test plug cylindrical 1" with plug-in nipple 500678.5
7
Test plug cylindrical 1¼" with plug-in nipple 500678.6
Test plug ½" with plug-in nipple 500694
Multiple connection plug ³∕8" and ¾" with plug-in nipple 500679.1
Multiple connection plug ½" and 1" with plug-in nipple 500679.2
Multiple connection plug 1" and 1¼" with plug-in nipple 500679.3
Y connector, 2 x coupling DN 5, 1 x shut-off valve, 1 x plug-in nipple 500690
T connector, 2 x coupling, 1 x shut-off valve, 1 x plug-in nipple 500695
Connection hose 0.3 m with plug-in nipple, DN 5 coupling 500687
Connection hose 1 m with plug-in nipple DN 2.7, DN 5 coupling 500685
Connection hose 2 m with plug-in nipple DN 2.7, DN 5 coupling 500689
Connection hose 3 m, 2 x locking coupling DN 5 500686
Connection hose for low pressure, plug-in socket DN 5 500688
Adapter for compressor connection 500696
Hand-operated bulb pump with 2 x valve 523082
Connection hose 0.34 m for hand/operated bulb pump 522952
Hand-operated bulb pump with connection hose 0.34 m 511018

110 www.afriso.com
Communication Accessories

App EuroSoft live for displaying the values


­measured by CAPBs® sensor modules

live

Benefits Free iOS and Android apps for all CAPBs® sensor modules

"Live" indication of the measured values

Application-specific, menu-guided programs

Logging of measurement data via data logger

Transfer of measurement log via e-mail or messenger services (such as WhatsApp)

Application EuroSoft live is the free app for operation of all CAPBs® sensor modules via smartphone or tablet.

Description The CAPBs® sensor modules communicate with the mobile device via Bluetooth® Smart. EuroSoft live
thus allows for "remote control" of the sensor modules and for "live" indication of the measured values
in application programs - just like the representation on the BlueLine series handheld measuring instru-
ments. Measurement results can be conveniently visualised, stored in measurement logs and transmit-
ted via the standard communication capabilities of mobile devices (such as email, WhatsApp, cloud
services). 7

Intuitive device connection and menu-guided measurement

Connecting to CAPBs® Selecting a measurement Starting a measurement

www.afriso.com 111
Accessories Communication

Evaluation software and app EuroSoft mobile


for BlueLine measuring instruments

Benefits Android/iOS app "EuroSoft mobile" for smartphones and tablets

PC evaluation software "EuroSoft mobile" for Windows operating systems*

Free and suitable for many devices of the BlueLine series

Application For processing and visualisation of measurement results/logs of BlueLine measuring instruments.
Ideal for long-term measurements and adjustments or for use of the optional data logger function for
professional, comprehensive documentation of results for customers. The EuroSoft mobile software
allows you to transmit measured values to smartphones, tablets or PCs. The data can then be further
processed or sent via e-mail. The evaluation software is suitable for BlueLine measuring instruments
and can be used on iOS, Android or Windows operating systems.

Example of a
measuring
log as a QR code

112 www.afriso.com
Communication Accessories

Evaluation software and app


EuroSoft mobile

Description If the software is used as a PC software, the data is transmitted via a Bluetooth® Smart connection.
A USB-Bluetooth® Smart dongle connects to the BlueLine measuring instrument and provides the
functions "Live Display" and "Remote Device Control".

The app provides for various communication possibilities:


1. Via the QR code generator integrated into the BlueLine measuring instruments. The generator
creates a QR code with the measurement data; this code can be scanned by smartphones and
tablets and then be processed with the application. The measurement logs are shown as HTML
files so that they can also be displayed in any browser or administration software or sent via e-mail,
regardless of the operating system used.
2. Via the Bluetooth® interface of the measuring instruments EUROLYZER ST/STe, MULTILYZER NG/
STe/STx or MAXILYZER NG/NG Plus. Pairing with mobile devices requires Android 4.0 or higher.
Measurement results are directly processed and visualised in the Android app EuroSoft mobile.
3. Via the Bluetooth® Smart interface of the measuring instruments BLUELYZER ST, EUROLYZER STx,
MULTILYZER NG/STe, S4600 ST, TMD 9 or BlueAir-ST®. Measurement results are directly pro-
cessed and visualised in the iOS or Android app EuroSoft mobile.

EuroSoft mobile Use as app Use as PC software


Compatibility Bluetooth® interface: EUROLYZER BLUELYZER ST, EUROLYZER STx,
measuring instru- ST/STe, MULTILYZER NG and MULTILYZER STe/STx, S4600 ST,
ments MA XILYZER NG/NG Plus TMD 9, BlueAir-ST®
Bluetooth® Smart interface:
BLUELYZER ST, EUROLYZER STx,
MULTILYZER STe/STx, S4600 ST,
TMD 9, BlueAir-ST®
Operating system Devices with Bluetooth® interface: Windows XP, Windows Vista,
Android 4.0 or higher for Bluetooth Windows 7, Windows 8, Windows 10
connections
Devices with Bluetooth® Smart
interface: Android 4.3 or higher,
iOS 6.0 (Bluetooth 4.0) or higher for
Bluetooth® Smart connections
Other Android versions:
Transmission via QR code
Functions ■■ Live visualisation of measured value ■■ Creation of customer database
as graphic or bar chart ■■ Editor for creating measurement
■■ Digital pressure gauge for pressure logs
measurement ■■ Arrangement and editing of fuels

■■ Conversion of QR code into indica- and measured variables


tion of measurement result ■■ Creation of user-specific fuels

■■ Measurement logs can be directly ■■ Live visualisation of measured

transmitted (e-mail, social networks, values as graphic or bar chart*


etc.) ■■ Remote device control of the meas-

■■ Transmission of the measurement uring instrument via Remote Viewer*


logs created, Windows version ■■ Etc. 7
■■ Etc.

* Possible with module USB-A for PC (Bluetooth® Smart dongle), see page 105

Software download

EuroSoft ■■ Google Play: ■■ PC evaluation soft- ■■ App Store:


mobile app ware EuroSoft mobile:

www.afriso.com 113
Accessories Communication

Notes

114 www.afriso.com
Maintenance/warranty Accessories

Maintenance contracts and extended warranty


for flue gas analysers

Get maximum reliability for your flue gas analyser

AFRISO offers comprehensive maintenance contracts with different calibration, annual service includes an inspection and, if neces-
terms for the flue gas analysers BLUELYZER, EUROLYZER, sary, replacement of the O2 and CO measuring cells. The basic
MULTILYZER and MAXILYZER as well as the dust measuring maintenance contract can be extended to cover additional
instrument. In addition to a complete function test and a device measuring cells.

Term Replacement of cells


Device calibration

Function test

COhigh cell
NO2 cell

SO2 cell
CO cell

NO cell
5 years

7 years

O2 cell

Maintenance contract selection


Part no. Price € / year
BLUELYZER ST • • • • • 579041

EUROLYZER STx • • • • • 579047


MULTILYZER STx • • • • • 579044
Dust measuring instrument STM 225 • • • 579046
Additional cell NO • 579000
As device

As device

Additional cell NO2 • 579001


Additional cell COhigh • 579002
Additional cell SO2 • 579003

i 7
*To be able to benefit from the full scope of the maintenance contract, you must close the maintenance contract for the
complete term (5 or 7 years) with annual maintenance intervals immediately after purchasing the flue gas analyser.
Maintenance must be performed regularly at the specified intervals of max. 11 to 13 months.

For device
Scope of warranty
series
Connection sockets/nipples
Battery/power supply unit

Selection extended warranty


MULTILYZER STe/STx

AFRISO warrants all flue gas analysers for a


EUROLYZER STx

Term 12 months
BLUELYZER ST

period of 12 months. An extended warranty


Thermocouple

covering damage to electronic components


or system peripherals is available.
Display

Part no. Price €


Extended warranty • • • • • • • • 579100

www.afriso.com 115
Accessories ISO calibration

ISO calibration for the portable measuring


instruments of the BlueLine series

Play it safe

Measuring instruments used in quality-related applications must be


calibrated at regular intervals. Even minimum measuring errors can
have a dramatic impact on the safety of plants or systems and on the
quality of manufactured products. Numerous standards and directives
in a vast variety of industries require quality assurance systems which
include regular monitoring and calibration of portable measuring
equipment. Product liability legislation also requires perfectly operat-
ing measurement equipment for quality-related measurement tasks.
Only systematic monitoring, regular calibration and complete docu-
mentation helps to protect you against liability claims.
7
In most cases, "ISO calibration" is sufficient to meet the requirements
of the standards and audits (such as ISO 9001).

During calibration, correct operation of the device is verified by a


comparison measurement with a calibration agent allowing for com-
parison against a national standard value. Compliance with the speci-
fications of the manufacturer is attested by means of a calibration cer-
tificate. This way, you are ready for the next audit.

116 www.afriso.com
ISO calibration Accessories

ISO calibration for the portable measuring


instruments of the BlueLine series
Calibration certificates Device series Part no. Price €

pressure
S4600 ST series, CAPBS® sens PS,
ISO calibration pressure 524210.01
CAPBS® sens PT, S2600-Serie
Temperature

ISO calibration temperature TM7, TMD7, TMD9, CAPBs® sens TK 524210.02

Pressure and temperature

ISO calibration pressure and temperature CAPBs® sens FP10 524210.03

Air velocity

ISO calibration vane anemometer BlueAir ST 524210.11

Gas

ISO calibration methane GSP1, CAPBs® sens GS10 524210.04

ISO calibration carbon monoxide CAPBs sens CO


®
524210.05

ISO calibration pressure, temperature and 2 gas sensors Flue gas analysers 524210.06

ISO calibration pressure, temperature and 3 gas sensors Flue gas analysers 524210.07

ISO calibration pressure, temperature and 4 or more gas sensors Flue gas analysers 524210.08

www.afriso.com 117
APPENDIX

AFRISO service
and technical information

SERVICE

AFRISO support centres 120

AFRISO service points 121

AFRISO service 122

Courses and training 123

AFRISO specialised company search 124

Information on EN 50379 125

GENERAL INFORMATION

AFRISO at a glance 126

General Terms of Delivery 130

AFRISO production sites 134

Notes on the catalogue 135

119
Appendix Service

Powerful sales.
AFRISO support centres

AFRISO sales office/field expert


portable measuring instruments
AFRISO production site

North/East

North/West

South/West

South/East

We ensure that you get professional, If you have questions:


personal service. Extensions +49 7135 102-
With a staff of more than 80 field and internal
experts! Please visit www.afriso.com/contact for Consulting on site: 
further information on your specific contact person.
North/West -433 North/East -435
South/West -433 South/East -255
Business hours:
Monday – Thursday: 7:00 a.m. – 12:00 a.m. and
Technical consulting -166
13:00 p.m. – 4:50 p.m.
Friday:  7:00 a.m.– 12:00 a.m. and
13:00 p.m. – 3:00 p.m. Hotline sales -134
(information on prices/delivery periods)

Service and repairs -211

120 www.afriso.com
Service Appendix

AFRISO service points – close by, guaranteed.


Service Germany

AFRISO production site with service point SP


SP AFRISO service partner
for measuring instruments and analysers
JP AFRISO adjustment partner
for measuring instruments and analysers JP
SP SP

SP
SP
JP
JP

SP JP

SP
SP
JP SP

SP

SP JP

SP
JP
JP
SP

SP

www.afriso.com 121
Appendix Service

Our Service – Your Benefit

Flexible, cost-aware, on schedule, solution-orientated


and fast – the AFRISO team always provides the decisive added value.

Information and presentation Repair service


Whether telephone support or on site: Our con- In the case of a malfunction, send us your
sultants speak your language – we provide you instrument along with a short description of the
with personal and individual consulting worldwide. problem. We will repair it within a few workdays.
And if you have an in-house event for your cus-
tomers, we will be glad to participate. Rental service
You cannot afford to do without your instrument?
After sales service No problem, our on-site service ensures that you
Whether commissioning, professional mainte- remain on duty. We will have your instrument
nance, calibration or function checks – a network picked up and send you a rental instrument. For
8 of service centres and our specialists in the plant a low rental fee. Ask for availability of this service
support you in getting the maximum out of your in your country.
AFRISO product. For safe processes, precise
measurement results, compliance with legal
requirements and a long service life.

i
Our service and repair
department will be glad to
answer your questions.
Please get in touch with us.
Telephone: +49 7135 102-211

122 www.afriso.com
Service Appendix

Notes

www.afriso.com 123
Appendix Service

Notes

124 www.afriso.com
Service Appendix

Information on EN 50379
portable measuring instruments

As of March 01, 2007 EN 50379 for portable measuring instruments went into effect. This standard covers devices used to determine
the gas concentration and other combustion parameters in the installation and maintenance of domestic and industrial heating systems
with standard fuels. The standard defines the design, testing and operating requirements for portable devices which are used to deter-
mine specific flue gas parameters such as the concentration of individual gas components, the temperature and/or the pressure in
combustion processes in order to ensure the compliance of the operating behaviour of combustion systems with national directives.

The standard is divided into three parts:

Part 1: General requirements and test procedures


EN 50379-1 specifies the general requirements concerning the design, testing and operating behaviour of devices used
for short-term measurements to determine specific flue gas parameters such as the concentration of individual gas com-
ponents, the temperature and/or the pressure in combustion processes in order to ensure the compliance of the operat-
ing behaviour of combustion systems using commercially available fuels in domestic and industrial applications with
national directives.

Part 2: Requirements concerning the operating behaviour of devices used in statutory measurements and
assessments
EN 50379-2 applies to devices which are used in statutory measurements or measurements specified by regulations.
National legislation covering the operating behaviour of combustion systems exists in several European countries.
Authorised inspectors use such devices to measure flue gas parameters and verify the compliance of combustion
systems with national directives.
Since the results of such measurements have statutory consequences, there are stringent requirements concerning the
accuracy of these devices. Therefore, EN 50379-2 specifies maximum values for measuring inaccuracy. Tests with real
flue gases constitute an essential part in the proof of suitability for statutory measurements. The determination of the
measuring inaccuracy must be demonstrated and confirmed with internationally approved methods for the entire meas-
uring range.

Part 3: Requirements for devices in non-regulated areas in the maintenance of gas-fuelled heating facilities
EN 50379-3 applies to devices which are used in non-statutory applications. The requirements are less stringent
because the devices are used in determining whether a gas-fuelled combustion system may require maintenance or
in setting up a gas-fuelled combustion system during maintenance. The measuring inaccuracy does not need to be
determined for such devices. These devices do not meet the technical measuring specifications as required in part 2.
Therefore, devices certified according to EN 50379-3 are not suitable for measuring combustion systems. Therefore,
devices certified according to EN 50379-3 are not suitable for measuring combustion systems.

All flue gas measuring instruments as well as BlueLine pressure and temperature measuring instruments meet the strin-
gent requirements of EN 50379-2. The TÜV quality mark (OCTAGON) certifies EN 50379-2 compliance and may only be used if the
production is audited by TÜV-SÜD at regular intervals. This line of measuring instruments with the TÜV-OCTAGON mark is backed by
experience and competence. High quality pays off – both price/performance ratio and cost of ownership are convincing. High-quality
measuring instruments also help you avoid conflicts and problems in terms of product liability.

www.afriso.com 125
Appendix AFRISO

AFRISO product programme.

Technology for environmental protection


AFRISO monitors, controls and protects the elements fire, water, Product development revolves around our motto "Technology for
earth and air – in the broadest sense. On the one hand, these ele- Environmental Protection". We strive to improve the environment,
ments symbolically stand for the relief and protection of the envi- to make processes which work with greater environmental com-
ronment – and on the other, they illustrate our fields of activity: patibility and to avoid putting a strain on the environment. With a
balanced portfolio of innovations, proven products, systems and
Flue gas control services, we offer our customers efficient solutions which are of
Energy savings great benefit.
Groundwater protection
Conservation of resources

Tank. Heating. Water Technology.


With a comprehensive range of building technology products,
AFRISO prides itself in "Making Heating Systems Safe". Irrespective
of whether the heating system uses regenerative energy or fossil
fuels. In addition to this extensive range, a large selection of alarm
instruments for the fast detection of level, liquid spillage, leakage,
gas or smoke is available.

Mechanical/pneumatic level indicators


Overfill prevention systems/overfill alarm systems
Leak detectors/leak monitoring systems
Inner tank linings
Equipment for fuel oil storage tanks, oil carrying pipes,
boiler rooms, boilers and heating systems
Heating controllers
Distribution manifolds for heating, cooling and
geothermal systems
Smart home systems for building automation
Valves and control technology for radiators
and hydraulic balancing
Equipment for drinking water supply

Gas analysis and service instruments

The BlueLine series is the perfect solution for official measure-


8 ments, adjustment, servicing, maintenance and repair work. You
benefit from an optimally tuned range of measuring instruments
which is continuously setting new standards – from basic devices
all the way to portable all-in-one flue gas analysers. AFRISO offers
gas analysers, gas sampling probes and turnkey analysis systems
with data acquisition systems for continuous emission monitoring.

Portable gas analysers


Portable measuring instruments, analysers and testers
Modular sensor module systems
Gas alarm units
Stationary gas analysers
Emission measurement technology
Measurement data acquisition systems

126 www.afriso.de
www.afriso.com
AFRISO Appendix

Pressure. Temperature. Level.


In addition to our comprehensive range of mechanical and elec-
tronic pressure, temperature and level instruments, we also offer
suitable mounting and installation accessories as well as display,
control and evaluation devices.
AFRISO measuring instruments cover the following ranges:
Pressure: 0/2.5 mbar to 0/4,000 bar
Temperature: -50 °C to +1,100 °C
Level: 0/20 cm to 0/250 m

Pressure gauges
Accessories for pressure gauges
Chemical seals
Pressure transducers
Bimetal thermometers and gas filled thermometers
Thermostats
Resistance thermometers
Electronic level indicators
Display, evaluation and control units
Event reporting systems/communication systems

Special designs
and system solutions
In addition to our comprehensive range of standardised, proven
off-the-shelf products, we also offer customised special products 8
made exactly to your requirements. We are constantly setting new
standards with innovative concepts, e.g. using plastic fittings in-
stead of metal ones or a combination of plastic and brass materials
in complex assemblies. Our range does not only cover the delivery
of individual sensors, but includes suitable components for power
supply and evaluation of the measurement signals. In the case of
system solutions, we do the entire engineering for you, all the way
to the production of the finished system.

Adapted to your specific requirements


Housing geometry
Shape and colour
Mechanical or electrical connections
Pre-assembled, tested, ready-to-connect assemblies

www.afriso.de
www.afriso.com 127
Appendix AFRISO

Convincing solutions for a wide variety of applications.

We know your industry


AFRISO is at home wherever there is measuring, controlling our knowledge of the requirements in the individual markets
or monitoring required. As a full-range manufacturer, we offer make us a reliable partner in your industry. We know what is
our customers a broad product portfolio from a single source. necessary as a result of our many years as a supplier in the OEM
A wealth of experience from numerous applications as well as business and our intensive contact with standardisation commit-

Building technology

The subject of saving energy has been our focus for more than environmental protection. Innovative measuring instruments for
50 years. From the start, we have supported the move towards flue gas analysis yield high-precision and reproducible results so
geothermal and solar systems as well as the use of biogenous that your customers can achieve their goals: the right amount of
fuels by supplying professional components and assemblies. heat at the right time, low energy consumption and low emis-
Our range for the secure storage of fuel oil and professional sions. And we always respond to sustainable new technologies,
equipment for heating systems reduces operating costs, helps for example, be providing compelling sensors and systems for
make optimum use of fuels, provides timely warnings if hazard- increasing security and convenience in smart homes.
ous situations arise and constitutes an active contribution to

Target markets
Manufacturer of heat generators

Manufacturers of solar thermal systems

8
System suppliers of panel heating systems

Tank protection/revision

Tank manufacturers

Heating and plumbing system wholesalers

Electrical wholesalers

Engineering and planning consultancies

Smart home and building automation

Manufacturers of fittings

Chimney sweeps

Public institutions, municipalities


128 www.afriso.com
AFRISO Appendix

tees, associations and guilds. We tap our employees' know-how building technology or facilities – you benefit with a strong part-
and expertise in the industry to make our customers' processes ner at your side.
simpler, safer and more competitive. In process engineering, in

Industrial technology and process engineering

Reliability, precision and a long service life are crucial when it pertinent directives and standards. Certificates, for example for
comes to highly automated processes. Our robust measuring food-quality materials, explosion protection and resistance to
devices deliver perfect measurement results and reliably mon- media and temperatures attest to this.
itor and control simple to highly complex processes – even un-
der the most adverse conditions. AFRISO solutions meet the

AFRISO products meet the requirements


Wide variety of process connections
 Target markets
Large selection of materials
 Machines and plants

Tanks

Compact designs
 8
Hygienic and easy to clean
 Food and beverages industry

Suitable for CIP and SIP
 Chemical industry

FDA-listed materials
 Pharmaceutical industry

Silicone-free versions
 Cosmetics industry

Resistant to corrosive and abrasive media
 Biotechnology

High overload safety
 Refineries

Resistant to vibration and temperature
 Offshore industry

Mineral oil industry

Raw materials industry

Hydraulic and pneumatics (fluid engineering)

Medical technology, safety engineering

Energy production

Technical trade


www.afriso.com 129
Appendix Terms of delivery

General Terms of Delivery


of AFRISO-EURO-INDEX GmbH · Lindenstraße 20 · 74363 Güglingen

§ 1 Validity not constitute guaranteed characteristics, but descriptions or


(1) All our deliveries, services and offers are exclusively made markings of the delivery or service. Any standard deviations
on the basis of the General Terms of Delivery. These General and deviations which are made according to statutory pro-
Terms of Delivery are part of all contracts with our contract visions or which represent technical improvements, as well
partners (hereinafter referred to as "customers") we conclude as the replacement of components by equivalent parts, are
pertaining to the deliveries or services provided by us. permissible if they do not impair the usability for the purpose
(2) General terms and conditions of the customer shall only intended by the contract.
become part of the contract if we expressly consent to their (5) We reserve the right to property or copyright to all offers and
validity in writing. This consent requirement shall apply in any cost estimates submitted by us as well as to all drawings,
and all cases, even if, for example, we carry out deliveries to illustrations, calculations, brochures, catalogues, models,
the customer without expressly rejecting the customer's gen- tools and other documents and equipment provided to the
eral terms and conditions even though we are aware of such customer. The customer shall not be permitted to disclose
terms and conditions. these objects, as such or in content, to third parties, to make
(3) Our General Terms of Delivery shall only apply if the customer them known, to use them himself or through third parties or to
is a business person (§ 14 BGB, German Civil Code), a legal reproduce them. At our request, he shall be obliged to com-
person of public law or a public-law fund. pletely return such objects to us and to destroy any copies
(4) The General Terms of Delivery shall apply in particular to produced if they are no longer required by him in the normal
contracts covering the sale and/or delivery of movable goods course of business or if negotiations do not lead to the conclu-
("goods"), regardless of whether we manufacture the goods sion of a contract. Storage of data provided electronically for
ourselves or purchase them from suppliers (§§ 433, 651 BGB, the purpose of standard data backup shall be the only excep-
German Civil Code). Unless otherwise agreed, the General tion to this.
Terms of Sale in the version valid at the time of the customer's
order shall be deemed to be an outline agreement for future § 3 Prices and payment
contracts of the same kind; we shall not be obliged to state (1) The prices apply to the scope of services and delivery spec-
their validity for each and every individual case. ified in the order confirmations. Additional or special services
(5) Individual agreements with the customer (including supple- will be charged separately. The prices are in EURO ex works
mentary agreements, amendments and modifications) which plus packaging, the applicable value added tax, and, for
have been made in individual cases shall always take prece- export deliveries, customs duties as well as fees and other
dence over these General Terms of Delivery. The contents of public charges.
such agreements shall be subject to a written contract and/or (2) If the agreed prices are based on our list prices and if the
our written confirmation, subject to proof of the contrary. delivery is to be effected more than four months after conclu-
(6) Material declarations and notifications which are to submit- sion of the contract, our list prices valid at the time of delivery
ted to us by the customer after conclusion of contract (e.g, shall apply (minus any percentage discount or fixed discount
deadlines, notification of defects, declaration of withdrawal or that may have been agreed).
reduction) must be made in writing to be effective. (3) Invoices shall be payable within 30 days from the invoice date
(7) Any reference to the validity of statutory provisions is only for without any deduction, unless otherwise agreed in writing. The
the purpose of clarification. Even without such a clarification, date of unconditional credit on our business account shall be
therefore, the statutory provisions shall apply if and to the decisive for payment in due time. Payment by check shall be
extent that they have not been modified or expressly excluded excluded, unless agreed separately, as the case may be. If the
in these General Terms of Delivery. customer does not pay by the due date, an interest of 5 % per
year shall be due on the amounts payable; we shall be entitled
§ 2 Offer and conclusion of contract to claim higher interest and further damages.
(1) All our offers are free and non-binding, unless they are (4) Any set-off with counterclaims of the customer or retention
expressly marked as binding or contain a certain acceptance of payments due to such claims shall only be permissible if
period. We shall have the right to accept orders within a peri- and to the extent that such counterclaims are undisputed or
od of fourteen days after receipt. asserted by a court.
(2) The legal relationship between us and the customer shall be (5) We shall be entitled to deliver or provide outstanding deliveries
governed solely by the written purchase agreement, including or services after prepayment or provision of security if, after
these General Terms of Delivery. The written purchase agree- the conclusion of the contract, we become aware of circum-
ment contains all agreements between the parties with regard stances which substantially reduce the creditworthiness of
8 to the contract. Any communication by us not made in writing
prior to the conclusion of this contract is legally non-binding;
the customer and which jeopardise the payment of our out-
standing claims arising from the contract against the customer
any agreements of the contract parties not made in writing (including claims from other individual contracts pursuant to
shall be replaced by the written contract, unless it is expressly the same outline agreement).
stated that they shall be binding.
(3) Amendments and modifications to the agreements, including § 4 Delivery and delivery period
these General Terms of Delivery, must be made in writing (1) Deliveries are made ex works.
in order to be effective. With the exception of managers or (2) Time limits and deadlines for deliveries and services men-
authorized signatories, our employees are not entitled to make tioned by us are only approximate, unless a fixed deadline or
any differing verbal agreements. Transmission via telecom- a fixed date has been explicitly assured or agreed. If shipping
munication systems, in particular via fax or via e-mail, shall be has been agreed, delivery periods and delivery dates refer to
deemed to be a sufficient instrument in writing, provided that the date of transfer to the forwarding agent, freight carrier or to
the copy of the signed declaration is transmitted. any other third party in charge of shipping.
(4) Any information or representation whatsoever on our part with (3) Without prejudice to our rights arising from default of the cus-
regard to the delivery or service (such as, but not limited to tomer, we shall be entitled to demand from the customer an
weights, dimensions, performance values, loads, tolerances extension of delivery and performance periods or a postpone-
and technical data) shall be deemed to be approximate, unless ment of delivery and performance dates for the period during
the usability for the purpose provided by the contract requires which the customer does not meet his obligations pursuant to
accurate conformity. Such information or representations do the contract.

130 www.afriso.com
Terms of delivery Appendix

(4) We shall not be liable for impossibility of delivery or for delays this case, six workdays have passed since delivery or instal-
in delivery, if such impossibility or delay is caused by force lation, and
majeure or other events unforeseeable at the time of the con-  ithin this period, the customer has refused acceptance for
w

clusion of the contract which are beyond our control or for any reason other than for a defect of which the customer
which we cannot be held responsible or which we have not has notified us and which substantially impedes or make
caused (e.g. disruptions of operations of any kind, difficulties in impossible the use of the purchased item .
procuring materials or energy, transport delays, strikes, lawful
lockouts, lack of labour, energy or raw materials, difficulties § 6 Warranty, material defects, acceptance of the disposal
in procuring necessary regulatory approvals, governmental obligation by the customer
measures, or incorrect or delayed supply by suppliers. Insofar (1) The warranty period shall be one year from the date of delivery
as such events make the delivery or service substantially more or, if acceptance is required, from the date of acceptance. This
difficult or impossible and the hindrance is not only of tempo- period shall not apply to claims for damages on the part of the
rary duration, we are entitled to withdraw from the contract. In customer resulting from injury to life, body or health or from
the case of hindrances of a temporary nature, the delivery or wilful or grossly negligent breach of duty by us or our vicarious
performance periods shall be extended or the delivery or per- agents, which are subject to the limitation periods according
formance dates shall be postponed by the period of the hin- to the statutory provisions.
drance plus a reasonable start-up period. If, as a result of the (2) The goods delivered must be carefully inspected immediately
delay, the customer cannot reasonably be expected to accept after delivery to the customer or to the third party designat-
the delivery or service, the customer shall be entitled to with- ed by the customer. With regard to obvious defects or other
draw from the contract, which is to be performed immediately defects which would have been recognizable in the case of an
by an instrument in writing. immediate, careful examination, they shall be deemed to be
(5) We shall be entitled to deliver and provide partial deliveries accepted by the customer if we do not receive written noti-
and partial services only: fication of defects within seven workdays after delivery. With
 if the partial delivery is reasonable for the customer and suf- regard to other defects, the delivery items shall be deemed to
ficient consideration is given to his legitimate interests, have been accepted by the customer if the notice of defect
 if the delivery of the remaining ordered goods is assured and does not reach us within seven workdays after the date of
detection of the defect; if the defect was already recognizable
 if, as a result, the customer does not incur any substantial
by the customer at an earlier point in time in normal use, this
additional costs or additional efforts (unless we are willing to
earlier point in time shall be decisive for the beginning of the
pay for such costs).
complaint period. Upon request by us, a rejected delivery item
(6) If we are in default with a delivery or service or if a delivery or
must be returned to us free of freight charges. In the case of
service is impossible for any reason whatsoever, our liability
a justified complaint, we shall reimburse the costs of the least
for compensation shall be limited pursuant to provision § 8 of expensive type of shipping; this shall not apply if the costs
these general Terms of Delivery. increase because the delivery item is located at a place other
than the place of the intended use.
§ 5 Place of performance, shipping, packaging, (3) In the case of material defects of the goods delivered, we shall
passage of risk, acceptance first be obliged and entitled to rectify or replace the goods
(1) The place of performance for all obligations resulting from within a reasonable time. In case of failure, i.e. impossibili-
the contract shall be the registered office of our company in ty, unreasonableness, refusal or unreasonable delay of the
Güglingen, unless other agreements have been made. If the improvement or replacement delivery, the customer shall be
installation is part of the contract, the place of performance entitled to withdraw from the contract or to reasonably reduce
shall be the place at which the installation is to be performed. the purchase price.
(2) The type of shipping and packaging are subject to our discre- (4) Insignificant or typical variations in colour, dimensions, weight
tion. The cost of shipping and packaging shall be borne by the and quality shall not be considered to be defects of the deliv-
customer. If the customer requires drop shipping delivery, we ery items
shall charge a processing fee of EUR 10.00 for each delivery. (5) If a defect is the result of fault on our part, the customer shall
(3) In cases of small orders with a net purchase value of less than be entitled to claim damages under the conditions stipulated
EUR 100.00, we will charge a processing fee of EUR 15.00 in in provision § 8 hereto.
addition to shipping and packaging. (6) In the case of defects of components of other manufacturers,
(4) The passage of risk to the customer shall be the point in time which we cannot remedy for license or actual reasons, we will,
of the transfer of the good to be delivered (the beginning of at our discretion, assert our warranty claims against the man-
the loading process being decisive) to the forwarding agent, ufacturers and suppliers on behalf of the customer or assign
freight carrier or to any other third party in charge of shipping. them to the customer. In the case of such defects, there shall
This shall also apply in the case of partial deliveries or if we only be warranty claims against us subject to the other condi-
have undertaken other obligations (e.g. shipping or installa- tions and according to the provisions of these General Terms
tion). If the shipment or the transfer is delayed for a reason of Delivery and only if the aforementioned claims against the
caused by the customer, the transfer of risk shall be the day manufacturer and suppliers could not be enforced or if such
on which the good to be delivered is ready for shipment and
we have notified the customer to this effect.
enforcement is futile, for example, due to insolvency. During 8
the duration of the legal dispute, the period of limitation of the
(5) Storage costs incurred by us after transfer of risk shall be customer's warranty claims against us shall be suspended.
borne by the customer. If we store the goods to be delivered, (7) The warranty shall be void if the customer modifies the deliv-
the storage costs amount to 0.25% of the invoice amount of ery item without our consent or has it modified by a third party
the delivered goods per completed week. We reserve the right and such modification renders the rectification of the defect
to assert and prove further or lower storage costs. impossible or unreasonable. In any such case, the customer
(6) We shall provide for transportation insurance of the consign- shall bear the additional costs arising from such modification
ment. for rectification of the defect.
(7) If acceptance has to take place, the purchase item shall be (8) If, in individual cases, a delivery of used items is agreed with
deemed accepted if: the customer, such delivery shall be performed under exclu-
 the delivery and, provided we also have to perform installa- sion of any warranty for material defects.
tion, the installation are completed, (9) The customer shall be obliged to dispose of the delivered
 w e have communicated this to the customer with reference to goods when they are no longer used at his own cost and in
the deemed acceptance in accordance with this provision § 5 full compliance with all pertinent regulations. The custom-
(7) and have prompted the customer to accept the delivery, er shall indemnify us from the obligations pursuant to § 10,
 1 2 business days have passed since the delivery or installa- section 2 of the German Electronic Equipment Act (obligation
tion, or the customer has begun to use the purchased item of manufacturers to take back their products) and from any
(e.g. a delivered plant has been put into operation) and, in claims of third parties related to this.

www.afriso.com 131
Appendix Terms of delivery

The customer shall contractually oblige any other commer- (4) In the case of liability for simple negligence, our obligation to
cial third party to which the customer transfers the delivered indemnify for damage to property and consequential financial
goods to dispose of such goods according to the pertinent loss shall be limited to the amount covered by our liability
regulations when such goods are no longer used. Our claim insurance and standard in our industry, even in the case of a
to the above transfer of obligation/indemnification through the breach of essential contractual obligations. Upon request, we
customer shall be extended by a period of limitation of two will gladly provide the customer with a corresponding insur-
years after the final termination of the usage of the delivery ance confirmation stating the amount covered by the liability
item. The two-year period of suspension of the limitation shall insurance carrier.
not begin until we receive a written notice from the customer (5) The above exclusions and limitations of liability shall apply to
stating that he has ceased to use the device. the same extent on behalf of our organs, legal representatives,
employees and other vicarious agents.
§ 7 Infringement of property laws (6) If we provide technical information or consultancy services
(1) Pursuant to this provision § 7, we shall ensure that the delivery and such information or services are not a part of the scope of
item is free from industrial property rights or third-party copy- services agreed upon by contract and owed by us, this shall
rights. Each contract partner shall immediately notify the other be free of charge and without any liability whatsoever.
contract partner in writing if claims with regard to the infringe- (7) The limitations of this provision § 8 shall not apply to our lia-
ment of such rights are asserted against him. bility for intentional conduct, for guaranteed characteristics,
(2) In the event that the delivery item infringes an industrial prop- for injury to life, body or health or pursuant to the German
erty right or copyright of a third party, we shall, at our discre- Product Liability Act (Produkthaftungsgesetz).
tion and at our expense, alter or replace the delivery item in
such a way that no rights of third parties are infringed, but the § 9 Retention of title
delivery item continues to fulfil the contractually agreed func- (1) We retain the title to the sold goods until we have received full
tions; or we shall enter into a license agreement in order to payment of all our present and future receivables arising from
obtain the right to use the delivery item for the customer. If we the purchase contract and from an ongoing business relation-
should not be able to succeed within a reasonable period, the ship (secured claims).
customer shall be entitled to withdraw from the contract or to (2) Prior to full payment of the secured claims, the goods subject
reasonably reduce the purchase price. Any claims for damag- to retention of title shall neither be pledged to third parties nor
es of the customer are subject to the restrictions of provision § transferred to third parties for security. The customer shall
8 of these General Terms of Delivery. notify us in writing immediately if an application for the opening
(3) In the case of infringements of laws by products of other man- of insolvency proceedings is filed or if third parties attempt to
ufacturers delivered by us, we shall, at our discretion, assert seize the goods under retention of title (e.g. by means of dis-
our claims against the manufacturers and suppliers on behalf traint or attachment).
of the customer or assign such claims to the customer. In (3) In the case of a breach of contract by the customer, in par-
these cases, there shall only be claims against us subject to ticular in the event of non-payment of the purchase price due,
the provisions of this provision § 7 and only if the aforemen- we shall be entitled to withdraw from the contract pursuant to
tioned claims against the manufacturer and suppliers could the statutory provisions and to reclaim the goods as a result
not be enforced or if such enforcement is futile, for example, of retention of title and withdrawal. If the customer does not
due to insolvency. pay the purchase price due, we shall only be entitled to assert
(4) If an order is to be filled (designs, etc.) according to custom- these rights if we have previously set the customer a reason-
er specifications, drafts or instructions, the customer shall able deadline for payment without success, or if such a dead-
be fully responsible for obtaining all rights of commercial line is not required pursuant to the statutory provisions.
exploitation of the property rights that may be contained in (4) The customer shall be entitled to resell and/or process the
his specifications, drafts or instructions. If the execution of an goods under retention of title in the ordinary course of busi-
order according to specifications, etc. of the customer violates ness, subject to revocation pursuant to (c) below. In this case,
third-party property rights or labelling obligation, the customer the following provisions shall apply in addition.
shall undertake to indemnify us from any resulting claims for (a) The retention of title shall cover the full value of the products
compensation, compensation for expenses and / or reim- resulting from processing, mixing or combining our products; we
bursement of third parties. shall be deemed the manufacturer. If, in the case of processing,
mixing or combining with goods of third parties, their rights of
§ 8 Liability for damages in case of fault ownership remain, we shall acquire co-ownership to the ratio
(1) Our liability for damages, irrespective of the legal grounds, of the invoice amounts of the processed, mixed or combined
in particular from impossibility, delay, defective or incorrect goods. The same provisions that apply to the goods delivered
delivery, breach of contract, breach of obligations in the case under retention of title shall apply to the resulting new product.
of contractual negotiations and tort, shall be limited subject to (b) The customer shall assign to us, as a security, the claims
the provisions of this provision § 8. arising against third parties from the resale of the goods or of
(2) We shall not be liable in the case of simple negligence on the the product in whole or to the amount of our possible co-own-
part of our organs, legal representatives, employees or other ership pursuant to the preceding paragraph. We accept the
8 vicarious agents, to the extent that this is not a violation of assignment. The obligations of the customer pursuant to pro-
contractual obligations. Essential with regard to the contract vision § 9 (2) hereto shall also apply in respect of the assigned
are the obligation to deliver and/or install the delivery item in claims.
good time, its freedom from deficiencies in law and its free- (c) The customer shall remain entitled to collect the claim in
dom from defects which impair its functionality or usability addition to us. We undertake not to collect the claim as long
more than insignificantly, as well as advisory, protection and as the customer meets his payment obligations, as long as the
custodial obligations which allow the customer to use the customer performs and as long as we do not assert the reten-
delivery item as per contract, or which serve the protection of tion of title by exercising a right pursuant to provision § 9 (3)
the health or life of the customer's personnel or the protection hereto. If any of the above conditions are not met, we shall be
of his property against substantial damage. entitled to request the customer to notify us of the assigned
(3) To the extent that we are liable for damages pursuant to claims and the corresponding debtors and provide us with any
provision § 8 (2) hereto, such liability shall be limited to dam- information and the appropriate documents necessary for us
ages which we have foreseen at the time of conclusion of the to collect such claims, and to notify the debtors (third parties)
contract as a possible consequence of an infringement of the of such assignment. In this case, we shall also be entitled to
contract or which we should have foreseen applying due dili- revoke the customer's authorization to resell and process the
gence. Indirect damages and consequential damages which goods subject to retention of title.
are the result of defects of the delivery item shall only be sub- (d) If the liquidable value of the securities exceeds our claims
ject to damages o the extent that such damage is typically to by more than 10 %, we shall, at the customer's request,
be expected when the delivery item is used as intended. release securities at our discretion.

132 www.afriso.com
Terms of delivery Appendix

§ 10 Final clause
(1) If the customer is a merchant, a legal person under public law
or a public-law fund or if the customer has no general court
of jurisdiction in the Federal Republic of Germany, the place
of jurisdiction for all disputes arising from the business rela-
tionship between us and the customer shall be our registered
office in Güglingen or the registered office of the customer.
However, in such cases, Güglingen shall be the exclusive
place of jurisdiction for actions against us. This provision does
not affect statutory provisions regarding exclusive places of
jurisdiction.
(2) The relations between us and our customers are subject
exclusively to the laws of the Federal Republic of Germany.
The United Nations Convention on Contracts for the
International Sale of Goods (CISG) of April 11, 1980 shall not
apply.
(3) If and to the extent that the contract or these General Terms
of Delivery contain gaps in the provisions, those statutory
provisions shall be deemed to have been agreed upon which
the contract parties would have agreed upon in view of the
economic objectives of the contract and the purpose of these
General Terms of Delivery if they had been aware of the gaps.
Note
The customer shall be deemed to have been notified that we
store data relating to the contractual relationship pursuant
to § 28 Bundesdatenschutzgesetz (German Federal Data
Protection Act) for the purpose of processing such data and
that we retain the right to disclose such data to third parties
(e.g. insurance companies) if and to the extent such disclosure
is required to perform the contract.

November 2016

AFRISO-EURO-INDEX GmbH · Lindenstr. 20 · 74363 Güglingen · Phone +49 7135 102-0 · Telefax +49 7135 102-147 · E-mail: [email protected]

www.afriso.com 133
Appendix Plants

AFRISO production sites in Germany

Headquarters
AFRISO-EURO-INDEX GmbH
Lindenstr. 20
74363 Güglingen
Baden-Württemberg

A staff of more than 550


are at work for you in our
four German production
sites.

Plant Amorbach Plant Amorbach – Production of linings


AFRISO-EURO-INDEX GmbH AFRISO-EURO-INDEX GmbH
Friedhofstr. 3 Von-Stein-Straße 17
63916 Amorbach 63916 Amorbach
Odenwald/Bavaria Odenwald/Bavaria

Plant Illmensee Alsenz plant


Systronik GmbH GAMPPER GmbH
Gewerbestr. 57 Niedermoscheler Str. 2
88636 Illmensee 67821 Alsenz
Lake Constance/Baden-Württemberg Rhineland-Palatinate

134 www.afriso.com
Minimum order quantities / packing units
Many products can be manufactured in small quantities – in many cases, you may
even order a single piece.
However, for some items there are minimum ordering quantities or packing units.
The price list sections provide the appropriate information.

The product package contains the specified number of products or can be


delivered in the specified order quantity
An additional package contains the specified number of products

Small order handling fee / minimum order value


For very small orders with net values below € 100 a handling fee of € 15 will be charged.
No other minimum order conditions apply.

Return of goods
Goods can only be returned after prior approval by us and only up to 3 months after
delivery. Please note that only standard stock items can be returned; products not avail­
able from stock and devices with ATEX approval cannot be returned. For returned stock
items we charge 30 % of the price for testing and handling or at least € 40. Shipping
costs for returns are to be borne by the customer.

Prices / terms of delivery


Please refer to your local AFRISO representation or get in touch with the AFRISO head-
quarters for detailed price information and conditions. We will charge a fee of € 10,– per
shipment for drop shipping. Our Terms of Delivery apply (see page 130 or www.afriso.
com or appendix). This catalogue supersedes all previous versions, including previous
prices. All prices subject to change; the catalogue may contain printing errors.

Technical modifications
As we are constantly improving our products, we reserve the right to technical
modifications without prior notice.

Copyright
Copyright 2018 by AFRISO-EURO-INDEX GmbH.
No part of the catalogue may be reproduced, copied, distributed, translated or in any
other way processed without prior written approval of AFRISO-EURO-INDEX GmbH.

www.afriso.com 135
11/18/en

19/ 20
FLUE GAS ANALYSIS

Portable Measuring Instruments


PRESSURE
TEMPERATURE
HUMIDITY/MOISTURE
TIGHTNESS TEST
Catalogue

19/ 20
Portable Measuring
Instruments

Technology for environmental protection


Measuring. Controlling. Monitoring.

AFRISO-EURO-INDEX GmbH
Lindenstraße 20
74363 Güglingen
Germany
Phone +49 7135 102-0
Fax +49 7135 102-147
[email protected]
www.afriso.com

You might also like