Electrify the road
Terra DC fast chargers. The most
successful EV fast chargers in the market,
ranging from 20 to 180 kW and ideal
for urban applications, retail and
refueling stations.
                                             • Compact footprint
                                             • Maximized revenue generation
                                             • Future ready
—
The Terra DC fast chargers product
line consists of a unique offering,
with a wide range of ratings.
They are designed for convenient
charging of all electric vehicles,
including future models with high
voltage battery systems. The
compact size makes it perfect for
urban use, with flexibility to
upgrade charging power up to
180kW and ability to charge up to 3
vehicles at the same time.
                                                                                                      3
—
Terra DC Fast Charger
At a glance
CONNECTED 24/7/365 remote monitoring            UPGRADABLE power modules to support
and diagnostic, receiving updates over-         increasing demand for EVs and increasing
the-air to support every new EV on the          battery ranges
road
LCD touchscreen with high                                                             ROBUST all-
brightness and graphical                                                              weather powder-
visualization of the                                                                  coated stainless
charging process                                                                      steel enclosure
SAFETY emergency
stop push button to                                                                  CONVENIENCE
immediately stop                                                                     and hassle-free
charging operation                                                                   reach for drivers
                                                                                     with retractable
                                                                                     cable management
                                                                                     option
GREATER utilization                                                                  EASY installation
with up to 3                                                                         thanks to the
simultaneous                                                                         improved design
charging of electric                                                                 allows to connect
vehicles, with CCS,                                                                  and start-up the
CHAdeMO, and AC                                                                      charger in less
plug combinations                                                                    than 2 hours
                               AUTOMATIC authentication capability via CCS connector in the vehicle
                               thanks to easy OCPP integration and Autocharge functionality
                 —                               —                                   —
     MAX CHARGING POWER              MAX CHARGING VOLTAGE                     DIMENSIONS
          Terra 24: 20 kW                 CCS 920 V DC                   Height 1900 mm / 74.8 in
          Terra 54: 50 kW              CHAdeMO 500 V DC                  Width 565.5 mm / 22.3 in
          Terra 94: 90 kW                                                 Depth 880 mm / 34.6 in
 Terra 124: 120 kW (and 2 x 60 kW)                                        Weight 395 kg / 871 lbs
 Terra 184: 180 kW (and 2 x 90 kW)                                              (Terra 184)
4                E L E C T R I F Y T H E R O A D T E R R A FA S T C H A R G E R S
—
Why Terra DC fast chargers?
Advanced, flexible, compact and smart
    Power sharing for high                                                          Future-proof, flexible high-
    utilization                                                                     voltage technology
     Terra 124 and Terra 184 can charge two vehicles                                 Flexible, redundant power architecture
     simultaneously                                                                  supports high uptime
     High utilization of charging assets benefit both                                High-voltage charging range up to 920 V
     public and fleet business models
                                                                                     Fully compatible with current and future EVs
      upports all open charging standards in
     S
     flexible configurations                                                         Option to upgrade power over time, from 90 kW
                                                                                     up to 180 kW, to follow EV market growth
     Safety certified to the highest standards
    Reliable, compact                                                               Always connected, always
    and flexible design                                                             smart
     Based on the Terra platform, the most widely                                    24/7 connectivity, 99.5% ABB network uptime
     deployed DCFC family in the world
                                                                                     Remote services with remote firmware updates
     Space-saving, all-in-one footprint with very easy                               and upgrades
     installation and servicing
                                                                                     OCPP integration-ready as well as ABB Web
     Robust construction for all operational                                         Tools functionality
     environments
                                                                                     Autocharge and ISO 15118-ready for plug and
     Cable management options enhance longevity                                      charge operation
                                                                                                            5
—
Fast charging beyond 50 kW
Power sharing delivers high utilization
90kW Charging Points               Retail/Shopping Sites            Highway corridors and Fleets
Terra chargers can provide a       The Terra 124 charger can        The Terra 184 chargers can add
quick refill adding 100 miles of   provide a full battery charge    100 miles of range in as little as
range in as little as 15 minutes   to two vehicles simultaneously   10 minutes as well as fast-charge
(Terra 94) or 30 minutes           while drivers are shopping,      two vehicles at the same time in
(Terra 54).*                       dining or at the movies.         less than 20 minutes.*
       one EV                         one EV          two EVs           one EV             two EVs
        up to                          up to         each up to          up to            each up to
     90 kW                          120 kW           60 kW           180 kW               90 kW
                                                                             * actual charging speed depends
                                                                             on the electric vehicle model(s)
                                                                             and charging conditions
                                   —
                                   Simultaneous charging with
                                   high power fast chargers can
                                   deliver maximum charging
                                   asset utilization while
                                   serving an ever-growing
                                   population of large battery
                                   electric vehicles.
6                            E L E C T R I F Y T H E R O A D T E R R A FA S T C H A R G E R S
—
High voltage charging explained
A future-proof strategy
High voltage charging capabilities
                                                                                Some EV battery packs, such as with vehicles
As electric vehicles and their use cases diversify,
                                                                                designed for fleet usage, may only charge at high
high voltage DC charging has become more
                                                                                voltage ratings, demanding charging
important to increase charging power while
                                                                                infrastructure that can deliver power tailored to
ensuring as much efficiency, safety and usability in
                                                                                HV battery packs.
DC charging systems.
                                                                                ABB's Terra 94, Terra 124 and Terra 184 chargers
Traditional passenger vehicle battery packs are
                                                                                are designed to meet EV battery voltage
usually designed for 400 VDC charging, so many
                                                                                capabilities up to 920V to deliver charging
standard charging systems do not exceed 500 VDC
                                                                                services across a wider range of today’s and
capability. However, some newer vehicles may have
                                                                                tomorrow’s EVs.
battery packs that exceed 400 VDC, often in the
600 to 800 VDC range.
920 VDC
                                                                                                                          Typical
                                                                                    Premium           Typical             eTruck
                                                  ABB Terra                                            eBus
                                                                                      eCar                               600-850
                                                  chargers                                            550-800
                                                                                    up to 800                              VDC
                                                                                      VDC               VDC
                                                      HV
500 VDC                                            charging
                                                    DCFC                              Typical
                            Typical                150-920                             eCar
                           500 VDC                   VDC                              200-450
                             DCFC                                                      VDC
150 VDC
                               Infrastructure                                                         Vehicle
—
A high range of DC voltage
capability is demanded to
deliver efficient charging
service to every EV and use case.
                                                                                                       7
—
Terra charging times
All-in-one charging for every EV
                                                             Charging time (minutes)
                                               50 kW       90 kW          120 kW          180 kW
                                              Terra 54    Terra 94       Terra 124       Terra 184
                                             Terra 54HV
                                                                      2 EVs     1 EV   2 EVs    1 EV
                   60 kWh BEV
                   400 VDC                      50          25         40       20     25       13
                   90 kWh BEV
    Car
                   400 VDC                      70          40         60       30     40       20
                   100 kWh BEV
                   800 VDC                      80          45         65       33     45       22
                   120 kWh BEV
                   School Bus                   95          53         80       40     55       26
                   400 VDC
                   150 kWh BEV
                                               120          65        100       50     65       33
    Bus/Truck
                   Delivery Van
                   800 VDC
                   200 kWh BEV
                   Work Truck                  160          88        133       66     88       44
                   800 VDC
                   300 kWh BEV
                   60' Transit Bus             240         130        200      100     130      66
                   800 VDC
—
Charge times shown based on average
vehicle battery management system
(BMS) requesting charging power from
20% to 80% under mild environmental
conditions. Data assumes vehicles
capable of charging at cited power levels.
8                         E L E C T R I F Y T H E R O A D T E R R A FA S T C H A R G E R S
—
Flexible OCPP enablement
Back-office integrations backed by
ABB connectivity
Network communications
ABB has integrated with nearly every major charging
network around the world for OCPP support across
public and fleet charging operations. ABB chargers can
                                                                                             OCPP Integrations
be operated using a direct OCPP connection while                                             The Open Charge Point Protocol (OCPP)
linking to ABB's advanced diagnostics and firmware                                           includes a broad set of messages with a
update services for additional intelligence, technical                                       wide range of functionality for enterprise
support as well as reduced maintenance.                                                      telematics and usage data. The
                                                                                             transaction-based set-up of the
Leading the industry in implementing authentication                                          messages makes it easy to connect to a
technologies, ABB enables Autocharge coupled with an                                         back-end system to process charging
OCPP server. This functionality offers access control at                                     sessions, define usage models and
the vehicle level, ideal for fleet asset telematics. ABB’s                                   handle data. Other capabilities include
software engineers work with the latest standardized                                         integration with apps and energy
protocols in the EV charging industry including roaming                                      management, such as with OCPP Smart
platforms, energy management software and next                                               Charging Profiles.
generation authentication solutions.
                                                      Network/
    Web tools        ABB NOC
                                                      Operator                               Plug and charge
    customer         services                                                                Eliminating manual authentication
                                                                                             methods for drivers while delivering
                                                  Direct OCPP 1.6                            granular data sets to network operators
                                                                                             and fleets has never been easier with
                                                                                             'plug and play' charging solutions.
                                                                                             ABB supports Autocharge, in conjunction
                                                                                             with an OCPP network integration, to
            ABB EVCI                                                                         meet vehicle-based authentication
           connectivity            Connected                                                 demands seamlessly with any CCS
                                    Services
                                                                                             vehicle.
Better and faster support: Chargers connected to                                             Additionally, ABB has proactively enabled
ABB’s network operations center can achieve the                                              ISO 15118 (Plug & Charge) for its charging
fastest remote support from ABB network engineers.                                           systems to deliver more advanced plug
This leads to higher uptime of a charger network,                                            and play charging experience for the
minimizes the number of unplanned on-site visits, and                                        next generation of electric vehicles.
significantly reduces overall operational costs.
Scalability and security: IT resources can scale in the
ABB Ability cloud while connectivity monitoring is
supported by ABB around the clock. ABB leverages
Microsoft Azure based security with fewer backend
connections to monitor.
                                                                                                9
—
ABB EV Infrastructure services
For highest utilization and lowest
downtime
Operational excellence
Charging infrastructure must be optimized for the
highest utilization and lowest downtime. ABB’s
remote and real-time services meets that demand,
incorporating a decade of experience with
thousands of intelligent fast chargers deployed
across the globe.
ABB's Terra family of all-in-one chargers are the
easiest chargers in the market to service, with high
uptime due to its innovative modularity, round the
clock connectivity and experience-led design.
             Remote services                           Parts and warranty
             •   24/7 connectivity
                                                       services
             •   Remote services                       •   Full service warranty process
             •   Remote diagnostics                    •   Extended warranties
             •   Firmware upgrades                     •   Preventive service and maintenance
             •   Driver care web tools                 •   Network spare parts programs
             •   Charger Care web tools                •   Fleet spare parts programs
             Custom software                           Training
             services                                  • Standardized online training
                                                       • Customized service training
             • OCPP integration
                                                       • Third-party service training
             • Autocharge integration testing
                                                         programs
             • Interoperability testing and
               validation
             • Customized enterprise software
               support
10                         E L E C T R I F Y T H E R O A D T E R R A FA S T C H A R G E R S
—
Technical specification
                                          Terra 184                                              Terra 124
Product information
Charging type                             DC fast charging and AC type-2 charging                DC fast charging and AC type-2 charging
Outlet options                            C: CCS cable, J: CHAdeMO cable,                        C: CCS cable, J: CHAdeMO cable,
                                          T: AC Type-2 socket                                    T: AC Type-2 socket
Input AC power rating                     280 A, 192 kVA                                         187 A, 128 kVA
Input voltage range                       400 VAC +/- 10% (50 Hz or 60 Hz) - CE Version
                                          480 VAC or 270 VAC +/- 10% (50 Hz or 60 Hz) - UL Version
DC output power rating (max)              180 kW                                                 120 kW
AC output power rating (optional)         22 kW                                                  22 kW
DC output voltage                         150-920 Vdc                                            150-920 Vdc
Number of EV served                       Up to 3 (CCT, CJT models)                              Up to 3 (CCT, CJT models)
                                          Up to 2 (CC, CJ, JJ models)                            Up to 2 (CC, CJ, JJ models)
                                          Up to 1 (C models)                                     Up to 1 (C models)
Cable length                              3.9 m                                                  3.9 m
                                          Optional: 6.0 m / 8.0 m                                Optional: 6.0 m / 8.0 m
CCS cables maximum current                Standard: 200 A                                        Standard: 200 A
                                          High current: 400 A                                    High current: 400 A
CHAdeMO cables maximum current            200 A, 125 A (Optional)                                200 A
Network type                              TN-S, TN-C, TN-C-S, TT (Requires external RCD)         TN-S, TN-C, TN-C-S, TT (Requires external RCD)
Connector types                           3-phase, neutral, protective earth (CE models)         3-phase, neutral, protective earth (CE models)
                                          3-phase, protective earth (UL models)                  3-phase, protective earth (UL models)
Protection                                Overcurrent, overvoltage, undervoltage, ground fault including DC leakage protection, integrated surge protection
Overvoltage category                      Type II                                                Type II
Power factor (full load)                  > 0.96                                                 > 0.96
THDi                                      < 4.5%                                                 < 4.5%
Efficiency                                > 95% (peak)		                                         > 95% (peak)		
Standby power                             80 W                                                   80 W
                                          980 W (with heater active)                             980 W (with heater active)
Short circuit current                     10 kA (CE models)                                      10 kA (CE models)
                                          65 kA (UL models)                                      65 kA (UL models)
Pre- charge current                       <1A                                                    <1A
Inrush current                            < 100 A                                                < 100 A
Leakage current                           0.8 mA                                                 0.8 mA
Energy metering                           Optional: MID metering for AC and DC outlets
                                          Optional: Eichrecht/PTB compliant metering solution for AC and DC outlets
Cellular communication                    GSM / 4G / LTE                                         GSM / 4G / LTE
User interface
Connectivity                              Internet access via 4G / 3G / Ethernet (RJ45)          Internet access via 4G / 3G / Ethernet (RJ45)
User authentication                       App, ISO 15118 Plug'n'Charge, RFID, PIN code           App, ISO 15118 Plug'n'Charge, RFID, PIN code
User interface                            7" LCD high-contrast touchscreen                       7" LCD high-contrast touchscreen
Communication protocols                   OCPP 1.5 / 1.6 and OPC-UA                              OCPP 1.5 / 1.6 and OPC-UA
RFID Reader                               ISO 14443 A + B to part 4 and ISO/IEC 15693, Mifare, NFC, Calypso, Ultralight, PayPass, HID; and more
Emergency button                          Yes. The button can be removed with a retrofit kit.
Configuration
Software update                           over-the-air updates via ABB web portal
Control and configuration                 ABB web portal, on-board Service Portal, OCPP 1.6, OPC-UA
                                                                                                                                                    11
Terra 94                                         Terra 54                                          Terra 24
DC fast charging and AC type-2 charging          DC fast charging and AC type-2 charging           DC fast charging and AC type-2 charging
C: CCS cable, J: CHAdeMO cable,                  C: CCS cable, J: CHAdeMO cable,                   C: CCS cable, J: CHAdeMO cable,
T: AC Type-2 socket                              G: AC Type-2 cable, T: AC Type-2 socket           G: AC Type-2 cable, T: AC Type-2 socket
140 A, 96 kVA                                    C, CJ: 88 A, 55 kVA                               CJ: 32 A, 23 kVA
                                                 CT, CJT, CG, CJG: 112A, 77 kVA                    CT, CG, CJG with 22 kW
                                                 CG, CJG: 143 A, 98 kVA                            AC outlet: 63 A, 43 kVA
400 VAC +/- 10% (50 Hz or 60 Hz) - CE Version
480 VAC or 270 VAC +/- 10% (50 Hz or 60 Hz) - UL Version
90 kW                                            50 kW                                             20 kW
22 kW                                            43 or 22 kW                                       43 or 22 kW
150-920 Vdc                                      150-920 Vdc (HV), 150-500 Vdc                     150-500 Vdc
Up to 2 (CCT, CJT models)                        Up to 2 (CT, CJT, CG, CJG models)                 Up to 2 (CT, CJT, CG, CJG models)
Up to 1 (C, CJ models)                           Up to 1 (C, CJ models)                            Up to 1 (C, CJ models)
3.9 m                                            3.9 m                                             3.9 m
Optional: 6.0 m / 8.0 m                          Optional: 6.0 m / 8.0 m                           Optional: 6.0 m / 8.0 m
Standard: 200 A                                  125 A                                             125 A
High current: 300 A
200 A                                            125 A                                             125 A
TN-S, TN-C, TN-C-S, TT (Requires external RCD) TN-S, TN-C, TN-C-S, IT, TT (Requires external RCD) TN-S, TN-C, TN-C-S, IT, TT (Requires external RCD)
3-phase, neutral, protective earth (CE models)   3-phase, neutral, protective earth (CE models)    3-phase, neutral, protective earth (CE models)
3-phase, protective earth (UL models)            3-phase, protective earth (UL models)             3-phase, protective earth (UL models)
Overcurrent, overvoltage, undervoltage, ground fault including DC leakage protection, integrated surge protection
Type II                                          Type II                                           Type II
> 0.96                                           > 0.96                                            > 0.96
< 4.5%                                           < 5%                                              < 5%
> 95% (peak)		                                   > 94% (peak)                                      > 94% (peak)
80 W                                             80 W                                              80 W
980 W (with heater active)                       980 W (with heater active)                        980 W (with heater active)
10 kA (CE models)                                10 kA (CE models)                                 10 kA (CE models)
65 kA (UL models)                                65/10 kA (UL models)                              65/10 kA (UL models)
<1A                                              <1A                                               <1A
< 100 A                                          < 100 A                                           < 100 A
0.8 mA                                           0.8 mA                                            0.8 mA
Optional: MID metering for AC and DC outlets
Optional: Eichrecht/PTB compliant metering solution for AC and DC outlets
GSM / 4G / LTE                                   GSM / 4G / LTE                                    GSM / 4G / LTE
Internet access via 4G / 3G / Ethernet (RJ45)    Internet access via 4G / 3G / Ethernet (RJ45)     Internet access via 4G / 3G / Ethernet (RJ45)
App, ISO 15118 Plug'n'Charge, RFID, PIN code     App, ISO 15118 Plug'n'Charge, RFID, PIN code      App, ISO 15118 Plug'n'Charge, RFID, PIN code
7" LCD high-contrast touchscreen                 7" LCD high-contrast touchscreen                  7" LCD high-contrast touchscreen
OCPP 1.5 / 1.6 and OPC-UA                        OCPP 1.5 / 1.6 and OPC-UA                         OCPP 1.5 / 1.6 and OPC-UA
ISO 14443 A + B to part 4 and ISO/IEC 15693, Mifare, NFC, Calypso, Ultralight, PayPass, HID; and more
Yes. The button can be removed with a retrofit kit.
over-the-air updates via ABB web portal
ABB web portal, on-board Service Portal, OCPP 1.6, OPC-UA
12                        E L E C T R I F Y T H E R O A D T E R R A FA S T C H A R G E R S
—
Technical specification
                                         Terra 184                                              Terra 124
Multilanguage system                     English, Italian, Spanish, German, French, ... and more than 50 languages available and new languages
                                         configurable via ABB Web Tool				
General characteristics
IP and IK rating                         IP-54 and IK-10 (cabinet) / IK-8 (touchscreen)
Enclosure type                           Stainless steel 430 and Aluminium
Operational altitude                     Up to 2000 m                                           Up to 2000 m
Operating temperature range              -35 °C to +55 °C                                       -35 °C to +55 °C
Storage temperature range                -40 °C to +70 °C                                       -40 °C to +70 °C
Humidity                                 20-95 % Rh non-condensing                              20-95 % Rh non-condensing
Mounting                                 Free-standing cabinet                                  Free-standing cabinet
Dimensions (H x W x D)                   1900 x 565 x 880 mm                                    1900 x 565 x 880 mm
Mass                                     395 kg                                                 365 kg
Certification and standards
Charging system                          IEC 61851-1 ed 3, IEC 61851-21-2 ed 1, IEC 61851-23 ed 1, IEC 61851-24 ed 1, IEC 62196-2, IEC 62196-3, IEC 61000
Communication to the EV                  DIN 70121, ISO/IEC 15118 series ed 1 with PnC and EIM, CHAdeMO 1.2
Communication to the backend             OCPP 1.6 JSON
Safety                                   Risk assessment
Warranty                                 Base warranty 24 months after Site Acceptance Test or 30 months after factory delivery. Warranty extensions available
                                                                                                                               13
Terra 94                                         Terra 54                                          Terra 24
English, Italian, Spanish, German, French, ... and more than 50 languages available and new languages
configurable via ABB Web Tool
IP-54 and IK-10 (cabinet) / IK-8 (touchscreen)
Stainless steel 430 and Aluminium
Up to 2000 m                                     Up to 2000 m                                      Up to 2000 m
-35 °C to +55 °C                                 -35 °C to +55 °C                                  -35 °C to +55 °C
-40 °C to +70 °C                                 -40 °C to +70 °C                                  -40 °C to +70 °C
20-95 % Rh non-condensing                        20-95 % Rh non-condensing                         20-95 % Rh non-condensing
Free-standing cabinet                            Free-standing cabinet                             Free-standing cabinet
1900 x 565 x 880 mm                              1900 x 565 x 780 mm                               1900 x 565 x 780 mm
350 kg                                           325 kg                                            275 kg
IEC 61851-1 ed 3, IEC 61851-21-2 ed 1, IEC 61851-23 ed 1, IEC 61851-24 ed 1, IEC 62196-2, IEC 62196-3, IEC 61000
DIN 70121, ISO/IEC 15118 series ed 1 with PnC and EIM, CHAdeMO 1.2
OCPP 1.6 JSON
Risk assessment, Fire analysis
Base warranty 24 months after Site Acceptance Test or 30 monhts after factory delivery. Warranty extensions available
14                   E L E C T R I F Y T H E R O A D T E R R A FA S T C H A R G E R S
—
Designed for flexibility
A configuration for every use case
Terra 94/124/184 C                                 Terra 94/124/184 CC                                 Terra 94/124/184 CJ
Single outlet CCS with cable                       Dual outlet CCS with cable                          Dual outlet CCS and CHAdeMO
management system                                  management system                                   with cable management
                                                                                                       system and credit card reader
Power levels                         Charging standards                             Cable management               User access / payment
• 50 kW                              • CCS+CHAdeMO                                  • Reliable, tested system      • OCPP Integration
• 90 kW                              • CCS-only single outlet                       • Factory or field install     • Credit card reader
• 120 kW / 60 kW shared              • CCS-only dual outlet                                                        • PIN via Web Tools
• 180 kW / 90 kW shared                                                                                            • Autocharge/ISO 15118
—
For more information please contact:
ABB EV Infrastructure
Heertjeslaan 6,
2629 JG Delft
The Netherlands
Phone: +31 88 4404600
E-mail: [email protected]
abb.com/evcharging
                                                   9AKK107680A7947 - Rev. C- (02/2021)
© Copyright 2020 ABB. All rights reserved.
Specifications subject to change without notice.