This is to attest that
UNIVERSAL INSPECTION CO.LTD.
BLOCK NO.6, SHOP NO. A4, PLOT NO. 38
EAST AHMADI 60006, STATE OF KUWAIT
Calibration Laboratory CL-222
has met the requirements of AC204, IAS Accreditation Criteria for Calibration Laboratories, and has demonstrated
compliance with ISO/IEC Standard 17025:2017, General requirements for the competence of testing and calibration
laboratories. This organization is accredited to provide the services specified in the scope of accreditation.
Effective Date January 17, 2023
Expiration Date March 1, 2024
President
UNIVERSAL INSPECTION CO.LTD.
www.ui.com.sa
Contact Name Mr. Dinesh Kumar Kesavan Contact Phone +966-508836773r
Accredited to ISO/IEC 17025:2017 Effective Date January 17, 2023
CALIBRATION AND MEASUREMENT CAPABILITY (CMC)*
MEASURED RANGE UNCERTAINTY1,2 CALIBRATION METHOD OR
QUANTITY or DEVICE (±) PROCEDURE, STANDARD
TYPE CALIBRATED EQUIPMENT (OPTIONAL)
Dimensional
Vernier Caliper 0 mm to 300 mm 73 µm Using Caliper Checker
(Digital/Dial/Analog) &Length Bar as per
JIS B 7507
Height Gauge 0 mm to 300 mm 20 µm Using Caliper Checker
(Digital/Analog) &Length Bar as per
JIS B 7517
External Micrometer 0 mm to 25 mm 2.6 µm Using Gauge Blocks & Length
25 mm to 50 mm 3.6 µm Bars as per BS 870
Dial Gauge (Digital/Analog) 0 mm to 25 mm 9.8 µm Using Dial Gauge Calibrator
as per JIS B 7503
Mechanical
Torque Wrench Up to 350 N·m 5.8 N·m Torque Wrench
350 N·m to 900 N·m 36 N·m CalibrationSystem as per
ISO 6789
Tachometer Contact – Tachometer Calibrator as per
Up to 12000 rpm 1.3 rpm ASTM F2046
Photo –
Up to 12000 rpm 1.8 rpm
Weighing Balance 1 mg to 500 mg 0.09 mg Using F2 / M1 Class Weights
1 g to 200 g 0.10 mg as per OIML R 76
1 kg 0.12 g
5 kg 0.49 g
Pressure Gauge - Hydraulic 0 bar to 700 bar 6.0 bar Reference Pressure gauge
with HydraulicCalibration
Pump as per MSL Technical
guide
* If information in this CMC is presented in non-SI units, the conversion factors stated in NIST Special Publication
811 “Guide for the Use of the International System of Units (SI)” apply.
•
CL-222 Effective Date January 17, 2023
Universal Inspection Co. Ltd. Page 2 of 5
IAS/CL/100-1 IAS/CL/100-3
MEASURED RANGE UNCERTAINTY1,2 CALIBRATION METHOD OR
QUANTITY or DEVICE (±) PROCEDURE, STANDARD
TYPE CALIBRATED EQUIPMENT (OPTIONAL)
Pressure Gauge - 0 bar to 5 bar 0.08 bar High Pressure
Pneumatic PneumaticCalibration
Pump
as per BS EN 837
Vacuum Gauge 0 bar to -0.95 bar 0.07 bar Pressure Calibrator as per
ISO 3567
Sound Level Meter(1 kHz) 94 dB 1.1 dB Sound Level Calibrator as per
114 dB 1.2 dB ANSI S1.4
Thermal
Thermocouple, Resistance -20 °C to 600 °C 0.89 °C Using Temperature Calibrator
Temperature Detector 600 °C to 1200 °C 3.3 °C as per IEC 60751 & IEC
(RTD),Temperature 60584
Controller with Sensor,
Temperature Indicator with
Sensor, Temperature
Recorder with Sensor,
Digital Data Logger with
Sensor, Thermometer with
Sensor
Temperature bath, Oven, -20 °C to 600 °C 0.73 °C Resistance Temperature
Furnace, Temperature 600 °C to 1200 °C 3.2 °C Detector (RTD), S Type
Calibrator Thermocouple &Temperature
Calibrator ASTM E145
Electrical Temperature Using Temperature Calibrator
Simulation – Measure4 as per Euramet cg-11
Thermocouples
K- Type -160 °C to 1200 °C 1.5 °C
S- Type
170 °C to 1750 °C 2.3 °C
T-Type
R-Type -130 °C to 400 °C 1.4 °C
B-Type 150 °C to 1750 °C 2.3 °C
N-Type 950 °C to 1800 °C 2.4 °C
E-Type -100 °C to 950 °C 1.2 °C
J-Type -190 °C to 1200 °C 1.3 °C
Electrical Temperature
Simulation – Generate3
Thermocouples
K- Type -160 °C to 1200 °C 1.5 °C
S- Type
170 °C to 1750 °C 2.4 °C
T-Type
R-Type -130 °C to 400 °C 1.4 °C
B-Type 150 °C to 1750 °C 2.4 °C
N-Type 950 °C to 1800 °C 2.5 °C
E-Type -100 °C to 950 °C 1.1 °C
J-Type -190 °C to 1200 °C 1.3 °C
CL-222 Effective Date January 17, 2023
Universal Inspection Co. Ltd. Page 3 of 5
IAS/CL/100-1 IAS/CL/100-3
MEASURED RANGE UNCERTAINTY1,2 CALIBRATION METHOD OR
QUANTITY or DEVICE (±) PROCEDURE, STANDARD
TYPE CALIBRATED EQUIPMENT (OPTIONAL)
Electrical – DC/LF
DC Voltage Source3 0 μV to 20 mV 0.48 mV Multifunction
20 mV to 200 mV 2.3 mV Calibrator
200 mV to 2 V 0.03 V CLARKE- HESS 8080
2 V to 20 V 0.03 V Euramet cg-15
20 V to 240 V 0.70 V
240 V to 1000 V 5.8 V
AC Voltage Source3 0 mV to 20 mV 12 µV
(60 Hz) 20 mV to 200 mV 0.003 V
200 mV to 2 V 0.001 V
2 V to 20 V 0.01 V
20 V to 240 V 0.15 V
240 V to 1000 V 2.0 V
DC Current Source3 1 µA to 200 µA 12 µA
200 µA to 2 mA 12 mA
2 mA to 20 mA 0.78 mA
20 mA to 200 mA 0.01 A
200 mA to 2 A 0.02 A
2 A to 10 A 0.04 A
10 A to 20 A 0.06 A
AC Current Source3 1 µA to 200 µA 12 µA
(50 Hz) 200 µA to 2 mA 0.17 mA
2 mA to 20 mA 1.2 mA
20 mA to 200 mA 12 mA
200 mA to 2 A 0.13 A
2 A to 10 A 1.2 A
10 A to 20 A 1.2 A
DC Resistance Source3 1 Ω to 100 Ω 0.04 Ω
100 Ω to 1 kΩ 0.02 kΩ
1 kΩ to 10 kΩ 0.11 kΩ
10 kΩ to 100 kΩ 0.15 kΩ
100 kΩ to 1 MΩ 0.03 MΩ
1 MΩ to 50 MΩ 0.58 MΩ
50 MΩ to 100 MΩ 1.6 MΩ
DC Voltage Measure4 0 mV to 100 mV 0.31 mV Precision Multimeter
100 mV to 1 V 0.03 V Fluke 8846A
1 V to 10 V 0.03 V as per Euramet cg-15
10 V to 100 V 0.04 V
100 V to 1000 V 0.07 V
CL-222 Effective Date January 17, 2023
Universal Inspection Co. Ltd. Page 4 of 5
IAS/CL/100-1 IAS/CL/100-3
MEASURED RANGE UNCERTAINTY1,2 CALIBRATION METHOD OR
QUANTITY or DEVICE (±) PROCEDURE, STANDARD
TYPE CALIBRATED EQUIPMENT (OPTIONAL)
AC Voltage Measure4 0 mV to 100 mV 53 µV Precision Multimeter
(60 Hz) 100 mV to 1 V 0.43 mV Fluke 8846A
1 V to 10 V 0.02 V as per Euramet cg-15
10 V to 100 V 0.43 V
100 V to 1000 V 4.6 V
DC Current Measure4 0 μA to 100 μA 5.8 µA
100 μA to 1 mA 10 µA
0 mA to 10 mA 8.2 mA
10 mA to 100 mA 0.02 mA
100 mA to 400 mA 20 mA
400 mA to 1 A 0.03 A
1 A to 3 A 0.04 A
3 A to 10 A 0.06 A
AC Current Measure4 0 μA to 100 μA 5.8 μA
(60 Hz) 100 μA to 1 mA 0.16 mA
1 mA to 10 mA 0.57 mA
10 mA to 100 mA 12 mA
100 mA to 400 mA 58 mA
400 mA to 1 A 0.06 A
1 A to 3 A 0.57 A
3 A to 10 A 1.2 A
DC Resistance Measure4 1 Ω to 100 Ω 3.4 Ω
1 kΩ to 10 kΩ 1.3 kΩ
10 kΩ to 100 kΩ 14 kΩ
100 kΩ to 1 MΩ 0.01 MΩ
1 MΩ to 10 MΩ 0.03 MΩ
10 MΩ to 50 MΩ 0.58 MΩ
50 MΩ to 100 MΩ 1.2 MΩ
DC Current Clamp Meter 20 A to 1000 A 4.2 A Multifunction Calibrator
AC Current Clamp Meter 3.5 A CLARKE-HESS 8080 &
20 A to 1000 A
Current Coil 140-50
using Clamp Meter
(ComparisonMethod)
1The uncertainty covered by the Calibration and Measurement Capability (CMC) is expressed as the expanded
uncertainty having a coverage probability of approximately 95 %. It is the smallest measurement uncertainty that a
laboratory can achieve within its scope of accreditation when performing calibrations of a best existing device. The
measurement uncertainty reported on a calibration certificate may be greater than that provided in the CMC due to the
behavior of the calibration item and other factors that may contribute to the uncertainty of a specific calibration.
2
When uncertainty is stated in relative terms (such as percent, a multiplier expressed as a decimal fraction or in scientific
notation), it is in relation to instrument reading or instrument output, as appropriate, unless otherwise indicated.
3Capability is suitable for the calibration of measuring devices in the stated ranges.
4Capability is suitable for the calibration of devices intended to generate the indicated quantity in the stated ranges.
CL-222 Effective Date January 17, 2023
Universal Inspection Co. Ltd. Page 5 of 5
IAS/CL/100-1 IAS/CL/100-3