This document provides information about a DeviceNet Slave/PROFIBUS Slave converter. It allows bidirectional communication between a DeviceNet and PROFIBUS network with electrical isolation. The converter can transfer up to 244 bytes of data in each direction and operates from 8-19V AC or 12-35V DC power. It is DIN rail mountable and works in an industrial temperature range of -40°C to 85°C. Configuration software is required to define network parameters, create a GSD file, and update the device configuration.

Uploaded by

120690
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
34 views18 pages

DeviceNet vs PROFIBUS Overview

This document provides information about a DeviceNet Slave/PROFIBUS Slave converter. It allows bidirectional communication between a DeviceNet and PROFIBUS network with electrical isolation. The converter can transfer up to 244 bytes of data in each direction and operates from 8-19V AC or 12-35V DC power. It is DIN rail mountable and works in an industrial temperature range of -40°C to 85°C. Configuration software is required to define network parameters, create a GSD file, and update the device configuration.

Uploaded by

120690
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 18

User Manual DeviceNet Slave / PROFIBUS Slave

Document code: MN67574_ENG Revision 1.001 Page 1 of 18


Industrial Electronic Devices

User Manual
Revision 1.001
English

DeviceNet Slave / PROFIBUS Slave -


Converter
(Order Code: HD67574-A1) HD67574-A1

for Website information:


www.adfweb.com?Product=HD67574

for Price information: For others Gateways / Bridges:


www.adfweb.com?Price=HD67574-A1
CANopen to Modbus
See also the following links:
www.adfweb.com?Product=HD67001 (Modbus RTU Master)
www.adfweb.com?Product=HD67502 (Modbus RTU Slave)
Benefits and Main Features: www.adfweb.com?Product=HD67504 (Modbus TCP Master)
www.adfweb.com?Product=HD67505 (Modbus TCP Slave)

Very easy to configure For others Gateways / Bridges:


For CAN bus 2.0A and/or CAN bus 2.0B to Modbus
Low cost See also the following links:
www.adfweb.com?Product=HD67011 (Modbus RTU Slave)
PROFIBUS Baudrate up to 12M www.adfweb.com?Product=HD67012 (Modbus RTU Master)
www.adfweb.com?Product=HD67514 (Modbus TCP Slave)
Wide supply input range www.adfweb.com?Product=HD67515 (Modbus TCP Master)

Isolation between two buses Do you have an your customer protocol?


See the following links:
Industrial temperature range: www.adfweb.com?Product=HD67003
-40°C / 85°C (-40°F / 185°F) Do you need to choose a device? do you want help?
Ask it to the following link:
www.adfweb.com?Cmd=helpme

ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31


User Manual DeviceNet Slave / PROFIBUS Slave
Document code: MN67574_ENG Revision 1.001 Page 2 of 18
Industrial Electronic Devices

INDEX: UPDATED DOCUMENTATION:

Page Dear customer, we thank you for your attention and we remind you that
INDEX 2 you need to check that the following document is:
UPDATED DOCUMENTATION 2 Updated
REVISION LIST 2 Related to the product you own
WARNING 2
TRADEMARKS 2 To obtain the most recently updated document, note the “document code”
SECURITY ALERT 3 that appears at the top right-hand corner of each page of this document.
EXAMPLE OF CONNECTION 4
CONNECTION SCHEME 5 With this “Document Code” go to web page www.adfweb.com/download/
CHARACTERISTICS 6 and search for the corresponding code on the page. Click on the proper
CONFIGURATION 6 “Document Code” and download the updates.
POWER SUPPLY 7
FUNCTION MODES 8 To obtain the updated documentation for the product that you own, note
LEDS 9 the “Document Code” (Abbreviated written "Doc. Code" on the label on
the product) and download the updated from our web site
PROFIBUS 10
www.adfweb.com/download/
RS232 10
DEVICENET 11
USE OF COMPOSITOR SW67574 12
REVISION LIST:
NEW PROJECT / OPEN PROJECT 12
SET COMMUNICATION 13
Revision Date Author Chapter Description
GSD FILE 13
1.000 03/02/2011 Fl All First release version
UPDATE DEVICE 14
1.001 14/01/2013 Nt & Fl All Added new chapters
MECHANICAL DIMENSIONS 16
ORDER CODE 16
ACCESSORIES 16
DISCLAIMER 17
OTHER REGULATIONS AND STANDARDS 17
WARNING:
WARRANTIES AND TECHNICAL SUPPORT 18
RETURN POLICY 18
ADFweb.com reserves the right to change information in this manual
PRODUCTS AND RELATED DOCUMENTS 18
about our product without warning.
ADFweb.com is not responsible for any error this manual may contain.

TRADEMARKS:

All trademarks mentioned in this document belong to their respective


owners.

ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31


User Manual DeviceNet Slave / PROFIBUS Slave
Document code: MN67574_ENG Revision 1.001 Page 3 of 18
Industrial Electronic Devices

SECURITY ALERT:

GENERAL INFORMATION
To ensure safe operation, the device must be operated according to the instructions in the manual. When using the device are required for
each individual application, legal and safety regulation. The same applies also when using accessories.

INTENDED USE
Machines and systems must be designed so the faulty conditions do not lead to a dangerous situation for the operator (i.e. independent limit
switches, mechanical interlocks, etc.).

QUALIFIED PERSONNEL
The device can be used only by qualified personnel, strictly in accordance with the specifications.
Qualified personnel are persons who are familiar with the installation, assembly, commissioning and operation of this equipment and who
have appropriate qualifications for their job.

RESIDUAL RISKS
The device is state of the art and is safe. The instrument can represent a potential hazard if they are inappropriately installed and operated
by personnel untrained. These instructions refer to residual risks with the following symbol:

This symbol indicates that non-observance of the safety instructions is danger for people to serious injury or death and / or the
possibility of damage.

CE CONFORMITY
The declaration is made by us. You can send an email to [email protected] or give us a call if you need it.

ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31


User Manual DeviceNet Slave / PROFIBUS Slave
Document code: MN67574_ENG Revision 1.001 Page 4 of 18
Industrial Electronic Devices

EXAMPLE OF CONNECTION:

ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31


User Manual DeviceNet Slave / PROFIBUS Slave
Document code: MN67574_ENG Revision 1.001 Page 5 of 18
Industrial Electronic Devices

CONNECTION SCHEME:

Figure 1: Connection scheme for HD67574-A1


ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31
User Manual DeviceNet Slave / PROFIBUS Slave
Document code: MN67574_ENG Revision 1.001 Page 6 of 18
Industrial Electronic Devices

CHARACTERISTICS:

The Configurable DeviceNet Slave / PROFIBUS Slave - Converter allows the following characteristics:
Two-directional information between network DeviceNet and PROFIBUS;
Eletrical isolation between two buses;
Up to 244 bytes in reading and 244 bytes in writing;
Power Supply 8…19V AC or 12…35V DC;
Mountable on 35mm Rail DIN;
Temperature range -40°C to 85°C.

CONFIGURATION:

You need Compositor SW67574 software on your PC in order to perform the following:
Define the parameter of the DeviceNet;
Define the parameter of the PROFIBUS;
Create a GSD File;
Update the device.

ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31


User Manual DeviceNet Slave / PROFIBUS Slave
Document code: MN67574_ENG Revision 1.001 Page 7 of 18
Industrial Electronic Devices

POWER SUPPLY:

The devices can be powered at 8…19V AC and 8…35V DC. The consumption depends to the code of the device. For more details see the two
tables below.

VAC VDC
Vmin Vmax Vmin Vmax
8V 19V 8V 35V

Consumption at 24V DC:

Device Consumption [W/VA]


HD67574-A1 3.5

Caution: Not reverse the polarity power

HD67574-A1

ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31


User Manual DeviceNet Slave / PROFIBUS Slave
Document code: MN67574_ENG Revision 1.001 Page 8 of 18
Industrial Electronic Devices

FUNCTION MODES:

The device has got two functions mode depending of the position of the ‘Dip2 of Dip-Switch A’:
The first, with ‘Dip2 of Dip-Switch A’ at “OFF” position, is used for the normal working of the device.
The second, with ‘Dip2 of Dip-Switch A’ at “ON” position, is used for upload the Project and/or Firmware.

For the operations to follow for the updating, see ‘UPDATE DEVICE’ section.

According to the functioning mode, the LEDs will have specifics functions, see ‘LEDS’ section.

ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31


User Manual DeviceNet Slave / PROFIBUS Slave
Document code: MN67574_ENG Revision 1.001 Page 9 of 18
Industrial Electronic Devices

LEDS:

The device has got three LEDs that are used to give information of the functioning status.
The various meanings of the LEDs are described in the table below.

LED Normal Mode Boot Mode

1: Not used (yellow) Not used Not used

2: Not used (green) Not used Not used

Blinks quickly: Boot state


3: Device State (green) Blinks slowly (~1Hz)
Blinks very slowly (~0.5Hz): update in progress

ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31


User Manual DeviceNet Slave / PROFIBUS Slave
Document code: MN67574_ENG Revision 1.001 Page 10 of 18
Industrial Electronic Devices

PROFIBUS:

The PROFIBUS uses a 9-pin D-SUB connector. The pin assignment is defined like in the right
figure.

Here some codes of cables:


Belden: p/n 183079A - Continuous Armor DataBus® ISA/SP-50 PROFIBUS Cable;

RS232:

The connection from RS232 socket to a serial port (example one from a personal computer),
must be made with a Null Modem cable (a serial cable where the pins 2 and 3 are crossed). It
is recommended that the RS232C Cable not exceed 15 meters.

The serial port is used for programming the device.

ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31


User Manual DeviceNet Slave / PROFIBUS Slave
Document code: MN67574_ENG Revision 1.001 Page 11 of 18
Industrial Electronic Devices

DEVICENET:

For terminate the DeviceNet line with a 120Ω resistor it is necessary that the Dip1 of ‘Dip-Switch B’ is at ON position.

Cable characteristics:

DC parameter: Impedance 70 Ohm/m


AC parameters: Impedance 120 Ohm/m
Delay 5 ns/m
Length Baud Rate [bps] Length MAX [m]
125 K 500
250 K 250
500 K 100

ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31


User Manual DeviceNet Slave / PROFIBUS Slave
Document code: MN67574_ENG Revision 1.001 Page 12 of 18
Industrial Electronic Devices

USE OF COMPOSITOR SW67574:

To configure the Converter, use the available software that runs with
Windows, called SW67574. It is downloadable on the site
www.adfweb.com and its operation is described in this document.
(This manual is referenced to the last version of the software present
on our web site). The software works with MSWindows (MS 2000, XP,
Vista, Seven, 8; 32/64bit).

When launching the SW67574 the right window appears (Fig. 2).

Figure 2: Main window for SW67574

NEW PROJECT / OPEN PROJECT:

The “New Project” button creates the folder which contains the entire device configuration.

A device configuration can also be imported or exported:


To clone the configurations of a programmable “DeviceNet Slave / PROFIBUS Slave –
Converter” in order to configure another device in the same manner, it is necessary to
maintain the folder and all its contents;
To clone a project in order to obtain a different version of the project, it is sufficient to
duplicate the project folder with another name and open the new folder with the button
“Open Project”.

ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31


User Manual DeviceNet Slave / PROFIBUS Slave
Document code: MN67574_ENG Revision 1.001 Page 13 of 18
Industrial Electronic Devices

SET COMMUNICATION:

This section defines the fundamental communication parameter of two Buses, PROFIBUS and DeviceNet.

By Pressing the “Set Communication” button from the main window for SW67574 (Fig. 2) the window
“SET COMMUNICATION” appears (Fig. 3).

The window is divided in two sections, one for the PROFIBUS and the other for the DeviceNet.

The means of the fields for ”PROFIBUS” are:


In the field “ID Dev.” the address for the PROFIBUS side is defined;
In the field "N Byte IN" the number of byte from the slave PROFIBUS to the gateway is defined
(at maximum it is possible to use 244 byte);
In the field "N Byte OUT" the number of byte from the gateway to the slave PROFIBUS is defined
(at maximum it is possible to use 244 byte).

The means of the fields for “DeviceNet” are: Figure 3: “Set Communication”
In the field “ID Dev.” the address of the DeviceNet is defined; window
In the field “Baud rate” the velocity of the DeviceNet bus is defined.

GSD FILE:

By pressing the “GSD File” button it is possible to save the GSD file for the PROFIBUS side.
With this feature you can save the configuration of the gateway of the PROFIBUS side.

Note:
When you import the .gsd file on your Master PROFIBUS you have to add all the modules that are present inside it.

ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31


User Manual DeviceNet Slave / PROFIBUS Slave
Document code: MN67574_ENG Revision 1.001 Page 14 of 18
Industrial Electronic Devices

UPDATE DEVICE:

By pressing the “Update Device” button it is possible to load the created Configuration into the device; and also the Firmware, if is
necessary.

In order to load the parameters or update the firmware in the gateway, follow these instructions:
Turn off the Device;
Connect the Null Modem Cable form your PC to the Gateway;
Put Dip2 of Dip-Switch A at “ON” position (see “FUNCTION MODES” section);
Select the “COM port” and press the “Connect” button;
Turn on the device;
Check the BOOT Led. It must blink quickly (see “LEDS” section);
Press the “Next” button;
Select which operations you want to do.
Press the “Execute update firmware” button to start the upload;
When all the operations are “OK” turn off the device;
Put Dip2 of Dip-Switch A at “OFF” position;
Disconnect the RS232 Cable;
Turn on the device.

At this point the configuration/firmware on the device is correctly update.

Figure 4: “Update Device” windows

ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31


User Manual DeviceNet Slave / PROFIBUS Slave
Document code: MN67574_ENG Revision 1.001 Page 15 of 18
Industrial Electronic Devices

Note:
When you install a new version of the software it is better if the first time
you do the update of the Firmware in the HD67574-A1 device.

Note:
When you receive the device, for the first time, you have to update also the Firmware in the HD67597-A1 device.

Warning:
If the Fig. 5 appears when you try to do the Update before require assistance try these points:
Check if the serial COM port selected is the correct one;
Check if the serial is connected between the PC and the device;
Try to repeat the operations for the updating;
If you are using a dongle try with a native COM port or change the dongle;
Try with another PC;
Try to restart the PC;
If you are using the program inside a Virtual Machine, try to use in the main
Operating System;
If you are using Windows Seven or Vista or 8, make sure that you have the
Figure 5: “Protection” window
administrator privileges;
Take attention at Firewall lock.

ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31


User Manual DeviceNet Slave / PROFIBUS Slave
Document code: MN67574_ENG Revision 1.001 Page 16 of 18
Industrial Electronic Devices

MECHANICAL DIMENSIONS:

Figure 7: Mechanical dimensions scheme

ORDER CODE:

Order Code: HD67574-A1 - DeviceNet Slave / PROFIBUS Slave - Converter

ACCESSORIES:

Order Code: AC34107 - Null Modem Cable Fem/Fem DSub 9 Pin 1,5 m

Order Code: AC34114 - Null Modem Cable Fem/Fem DSub 9 Pin 5 m

Order Code: AC34001 - Rail DIN - Power Supply 220/240V AC 50/60Hz – 12 V AC

Order Code: AC34002 - Rail DIN - Power Supply 110V AC 50/60Hz – 12 V AC

ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31


User Manual DeviceNet Slave / PROFIBUS Slave
Document code: MN67574_ENG Revision 1.001 Page 17 of 18
Industrial Electronic Devices

DISCLAIMER

All technical content within this document can be modified without notice. The content of the document content is a recurring audit.
For losses due to fire, earthquake, third party access or other accidents, or intentional or accidental abuse, misuse, or use under abnormal
conditions repairs are charged to the user. ADFweb.com S.r.l. will not be liable for accidental loss of use or inability to use this product, such
as loss of business income. ADFweb.com S.r.l. shall not be liable for consequences of improper use.

OTHER REGULATIONS AND STANDARDS

WEEE INFORMATION
Disposal of old electrical and electronic equipment (as in the European Union and other European countries with separate
collection systems).
This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish. Instead, it
should be taken to an applicable collection point for the recycling of electrical and electronic equipment. If the product is disposed
correctly, you will help prevent potential negative environmental factors and human health, which could otherwise be caused by
inappropriate disposal. The recycling of materials will help to conserve natural resources. For more information about recycling this
product, please contact your local city office, your household waste disposal service or the shop where you purchased the product.

RESTRICTION OF HAZARDOUS SUBSTANCES DIRECTIVE


The device respects the 2002/95/EC Directive on the restriction of the use of certain hazardous substances in electrical
and electronic equipment (commonly referred to as Restriction of Hazardous Substances Directive or RoHS).

CE MARKING
The product conforms with the essential requirements of the applicable EC directives.

ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31


User Manual DeviceNet Slave / PROFIBUS Slave
Document code: MN67574_ENG Revision 1.001 Page 18 of 18
Industrial Electronic Devices

WARRANTIES AND TECHNICAL SUPPORT:

For fast and easy technical support for your ADFweb.com SRL products, consult our internet support at www.adfweb.com.
Otherwise contact us at the address [email protected]

RETURN POLICY:

If while using your product you have any problem and you wish to exchange or repair it, please do the following:
1) Obtain a Product Return Number (PRN) from our internet support at www.adfweb.com. Together with the request, you need to
provide detailed information about the problem.
2) Send the product to the address provided with the PRN, having prepaid the shipping costs (shipment costs billed to us will not be
accepted).
If the product is within the warranty of twelve months, it will be repaired or exchanged and returned within three weeks. If the product is no
longer under warranty, you will receive a repair estimate.

PRODUCTS AND RELATED DOCUMENTS:

Part Description URL


HD67121 Gateway CANopen / Canopen www.adfweb.com?product=HD67121
HD67502 Gateway CANopen / Modbus - RTU www.adfweb.com?product=HD67502
HD67505 Gateway CANopen / Modbus – Ethernet TCP www.adfweb.com?product=HD67505
HD67134 Gateway CANopen / DeviceNet www.adfweb.com?product=HD67134
HD67117 CAN bus Repeater www.adfweb.com?product=HD67117
HD67216 CAN bus Analyzer www.adfweb.com?product=HD67216

ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31

You might also like