UNIK 5800/5900: Flameproof/Explosion-Proof Pressure Sensing Platform
UNIK 5800/5900: Flameproof/Explosion-Proof Pressure Sensing Platform
UNIK 5800/5900
Flameproof/Explosion-Proof
Pressure Sensing Platform
The 5800 and 5900 are compact and rugged
versions of the high performance UNIK 5000
pressure sensing platform offering both flameproof/
explosion-proof or dust ignition protection by
enclosure capability as required. They provide a
lightweight and cost effective alternative to pressure
gauges and switches in process and in oil and gas
industry applications.
We have the people and the knowledge to support • mV, mA and voltage outputs
your needs for accurate and reliable product
performance; our team of experts can help you
make the right sensor selection, guiding you
and providing the help and tools you need. It is
important that you ensure that the sensor materials
and performance selected are suitable for your
application.
5800/5900 Specifications Supply and Outputs
Electronics Description Supply voltage Output Current
Option (V) Consumption
Measurement (mA)
0 mV Passive 2.5 to 12 10 mV/V^ <2 at 10 V
Any zero based range between 3.5 and 50 bar 3 0 to 5 V 4-wire 7 to 16** 0 to 5 V <3
(51 to 725 psi) 4 0 to 5 V 3-wire 7 to 16** 0 to 5 V* <3
5 1 to 6 V 3-wire 7 to 16** 1 to 6 V <3
Sealed Gauge Ranges
6 0 to 10 V 4-wire 12 to 16** 0 to 10 V <3
Any zero based range between 10 and 700 bar
^ with a 10 volt supply mV output sensors give 100 mV over the full scale
(145 to 10,000 psi) pressure. Output is ratiometric to the supply voltage.
*0 to 5 V 3-wire output is non true zero. At pressures below 1% of span the
Absolute Ranges output will be fixed at approximately 50 mV
Any zero based range between 3.5 bar and 700 bar **32 V maximum for non-hazardous area operation
(51 to 10,000 psi)
Non Zero Based Ranges
Non zero based ranges are available. Please contact Supply Sensitivity
GE Measurement & Control to discuss your requirements ±0.005% FS/Volt (Voltage and current version only)
Electrical Connector
Connector Function
4 to 20 Voltage Voltage mV
Option Code
mA (3-wire) (4-wire)
5800 5 Red +ve Supply +ve Supply +ve Supply +ve Supply
8
Yellow - +ve Output +ve Output +ve Output
Brown - - -ve Output -ve Output
Black -ve Supply 0V Common -ve Supply -ve Supply
Orange - - - Shunt Cal
Green Case Case Case Case
Screen - - - -
5900 B I/P+ +ve Supply +ve Supply +ve Supply +ve Supply
J
O/P+ - +ve Output +ve Output +ve Output
O/P- - - -ve Output -ve Output
I/P- -ve Supply 0V Common -ve Supply -ve Supply
CE Conformity
UNIK 5800
Ex d IIC T6 Gb (-40°C <= Ta <= +63°C)
Ex tb IIIC T85°C Db (-40°C <= Ta <= +63°C)
Per certificate nos. Baseefa 12ATEX0047X & IECEx BAS 12.0075X (pending)
UNIK 5900
Ex d IIC T* Gb
Ex tb IIIC T* Db
T6/T85°C (-40°C <= Ta <= +70°C)
T5/T100°C (-40°C <= Ta <= +80°C)
T4/T135°C (-40°C <= Ta <= +100°C)
Per certificate nos. Baseefa 12ATEX0046X & IECEx BAS 12.0074X (pending)
Ordering Information
See the online configuration tool at www.unik5000.com
(1) Select model number
4) State cable lengths and units: Integer values only, e.g. 1m cable, 8 ft, minimum length 1 m (3 ft) cable
(only required on c ertain electrical connectors), Maximum cable length 190 m (570 ft)
(6.08)
(0.98)
(4.5)
(1.39)
(1.5)
(1.89)
(1.42)
(2.36) (0.43)
(3.47)
(3.64)
(1.04)
(2.15)
(1.03)
(1.03)
(5.73)
(0.05)
(0.86)
Available for pressure ranges
greater than 50 bar and
G1/4 or 1/4 NPT female, or
G1/2 or 1/2 NPT male
(0.98)
pressure connectors.
(5.36)
(0.05)
(0.61) (3.17)
www.ge-mcs.com
920-582A
© 2012 General Electric Company. All Rights Reserved. Specifications are subject to change without notice. GE is a registered trademark of General Electric Company. Other company or product
names mentioned in this document may be trademarks or registered trademarks of their respective companies, which are not affiliated with GE.