This document summarizes a hydraulically or pneumatically operated directional control valve: 1) The valve consists of a housing, control spool, and actuating section to control the start, stop, and direction of fluid flow. 2) It can operate at pressures up to 350 bar and flows up to 80 l/min, with minimum pilot pressures of 2 bar. 3) The valve has a five chamber design to reduce pressure dependence on fluid viscosity and interchangeable spools are available.

Uploaded by

Pritesh Korat
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
71 views2 pages

Datasheet RPH3-06 Ha4006 en Hydraulic Operated DCV

This document summarizes a hydraulically or pneumatically operated directional control valve: 1) The valve consists of a housing, control spool, and actuating section to control the start, stop, and direction of fluid flow. 2) It can operate at pressures up to 350 bar and flows up to 80 l/min, with minimum pilot pressures of 2 bar. 3) The valve has a five chamber design to reduce pressure dependence on fluid viscosity and interchangeable spools are available.

Uploaded by

Pritesh Korat
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

4/2 and 4/3 Directional Control Valve, Hydraulically or Pneumatically Operated

RPH3-06 Size 06 (D03)  Qmax 80 l/min (21 GPM)  pmax 350 bar (5100 PSI)

Technical Features

›› D irect acting directional control valve, hydraulically or pneumatically operated with subplate
mounting interface acc. to ISO 4401, DIN 24340 (CETOP 03)
›› High transmitted hydraulic power up to 350 bar with optimized design to minimize pressure drop
›› Five chamber housing design with reduced hydraulic power dependence on fluid viscosity
›› Minimum pilot pressure 2 bar (29 PSI) for maximum hydraulic power
Symbol ›› Wide range of interchangeable spools available
A B
›› Connection for hydraulic operation M10 x 1, G1/8, G1/4
›› In the standard version, the valve housing is phosphated and steel parts zinc-coated
P T for 240 h salt spray protection acc. to ISO 9227
›› Enhanced surface protection for mobile sector available (ISO 9227, 520 h salt spray)

Functional Description

These hydraulically or pneumatically operated directional control valves are used mainly to control start, stop
and direction of fluid. The valves consist of a housing, a control spool with two centering springs, and the
actuating section. The actuating section consists of the hydraulic or pneumatic actuation cylinder. The
ISO 4401-03-02-0-05 directional control valves are manufactured as two or three position valves (see table with functional symbols).

4xM5-6Hx13 Technical Data


31,75 (1.25)
0,75 (0.03) Valve size 06 (D03)
Max. flow l/min (GPM) 80 (21.1)
B G Max. operating pressure P, A, B bar (PSI) 350 (5080)
Max. operating pressure at port T bar (PSI) 160 (2320)
12,7 (0.50)

Min. pilot pressure bar (PSI) 2 (30)


40,5 (1.59)
30,2 (1.18)

Max. pilot pressure bar (PSI) 25 (360)


T P
21,5 (0.85)

Pilot volume cm3 (cu.in) 6,2 (0.38)


A Fluid temperature range (NBR) °C (°F) -30 ... +100 (-22 ... +212)
valve with 1 actuator 1.8 (3.96)
Weight kg (lbs)
5,1 (0.20) valve with 2 actuators 2.5 (5.50)
15,5 (0.61)
25,9 (1.16) Datasheet Type
31(1.22) General information GI_0060 Products and operating conditions
Mounting interface SMT_0019 Size 06
Ports P, A, B, T max ∅7.5 mm (0.29 in) Spare parts SP_8010

Characteristics measured at ν = 32 mm2/s (156 SUS)

Operating limits Pressure drop related to flow rate


Operating limits for maximum hydraulic power with min. piloting
pressure
350 (464) 32
Pressure drop D p [bar (PSI)]

(5076)
Pressure p [bar (PSI)]

1
(4351) 300 (406) 28
4 5 4
4 (348) 24
(3626) 250 3
3 2 (290) 20
(2901) 200 2
3 (232) 16
(2176) 150 1
2 (174) 12
(1450) 100 (116) 8
(725) 50 (58) 4

0 10 20 30 40 50 60 70 80 0 10 20 30 40 50 60 70 80
(2.6) (8.0) (13.2) (15.9) (21.1) (2.6) (5.3) (10.6) (15.9) (21.1)
Flow Q [l/min (GPM)] Flow Q [l/min (GPM)]

P-A P-B A-T B-T P-T P-A P-B A-T B-T P-T
Z11, P11, Y11, B11, R11, Z11, L21, B11,
A51, P51, X11, J15, J75 1 2 2 3 3 Y11 2 2 2 2
R11, X11, J15
C11, Y51 2 C11 4 4 4 5 3 A51, J75 2 2
H11 3 H11 2 2 2 2 3 P51 1 3
L21 4 P11 1 1 3 3 Y51 2 2

For operating limits under conditions and flow directions other than shown contact our technical support. Admissible operating limits may
be considerably lower with only one direction of flow (A or B plugged, or without flow.)

Page 1 www.argo-hytos.com
Subject to change · RPH3-06_4006_2en_04/2020
Dimension in millimeters (inches)
Valve with two positions Valve with three positions
one actuating section„a“ two actuating sections
9,5 (0.37) 12,5 (0.49)

15,5 (0.61)
THREAD SIZE

45,5 1.79
37,3 (1.37)
D1

5,3 (0.21) 8 (0.31)


123 (4.84) 47 (1.85) 68 (2.68) 47 (1.85)

Valve with two positions


one actuating section„b“

49,3 (36.4)
24 (0.94)
Thread size ∅ D1
M10 x 1, G1/8 15 (0.59) 8 (0.31)
G1/4 20 (0.79) 123 (4.84) 162 (6.38)

Spool Symbols

Type Symbol Interposition Type Symbol Interposition

Ordering Code

RPH3-06 / - -
4/2 and 4/3 directional Surface treatment
control valve, hydraulically No designation standard
or pneumatically operated A zinc-coated (ZnCr-3), ISO 9227 (240 h)
B zinc-coated (ZnNi), ISO 9227 (520 h)

Valve size Seals


No designation NBR

Number of valve positions Actuation


two positions 2 1 hydraulic
three positions 3 2 pneumatic

Connection for hydraulic operation


1 M10 x 1
Spool symbols 2 G1/8
see the table „Spool Symbols“ 3 G1/4

Mounting bolts M5 x 45 DIN 912-10.9 or studs must be orderer separately see Spare Parts data sheet HA 8010. Tightening torque is
8.9 Nm (6.56 Ibf.ft). Besides the commonly used valve versions shown other special models are available. Contact our technical support
for their identification, feasibility and operating limits.

www.argo-hytos.com Page 2
Subject to change · RPH3-06_4006_2en_04/2020