InteliDrive

DCU Marine

Order code: ID-DCU Marine

Embedded Certified Engine Controller for


Marine Applications
Datasheet
Product description
Specialized engine controller for Marine Symmetrical load sharing for propulsion engines
applications Propulsion, Auxiliary, Emergency, with J1939 (via CAN bus)
Harbour Integrated load and clutch control
Provide control, monitoring and protection for Switching between primary and secondary battery
variable type of engines Virtual shared inputs and outputs via CAN
Direct communication with Electronic Control Units
Over-speed and Emergency stop detection

Key features Communication capabilities including RS232,


RS485, Modem, Modbus, Internet, Ethernet
Support of machinery with multiple CAN devices
(ECU, ACM, SCR etc.) Remote monitoring via Modbus, TCP/IP, AirGate

Event driven History up to 4 000 records Cloud-based monitoring and control via
WebSupervisor
Redundant architecture: Main unit + Backup
module Active e-mail messaging and SMS

Backup ID-RPU module with hardwired protections Available also in low temperature (LT) version

Plug&Play support of InteliVision display family of Extendable with ComAp peripheral modules
ComAp IV5CANBL, IV8MARINE, IV12TOEM
Application overview
Tier 4 Final + Stage 5 control and visualization
Single speed engine operation
Configurable large PLC interpret with PLC editor
Auxiliary application
and monitor
Emergency application
Connection to engine via primary J1939 and
backup J1587 buses Combined application with harbor mode

Speed/load control via J1939/J1587 buses, Variable speed engine operation


Modbus, Binary and Analogue signals Propulsion application
Configurable Modbus Registers, Modbus RTU and
Modbus TCP support for easy integration into the
ship’s control system

| InteliDrive DCU Marine - 3.8.0 Data- | Related HW ver: 2.0.1 | Related SW ver: 3.8.0 | Date of issue: 5/17/2023
sheet
Speed pick-up input
Technical data
magnetic pick-up (connection by
Power supply Type of sensor
shielded cable is recommended)
Power supply range 8-36 V DC Input impedance 10 kΩ

Current consumption 0.34 mA / 8 V DC 4 Vpk-pk to 50 Vpk-pk in range 4 Hz to


Input voltage range
(depends on supply 0.12 mA / 24 V DC 1 kHz
voltage) 0.09 mA / 36 V DC Minimum measured
4 HZ
frequency
Galvanically isolated from
YES Maximum measured
controller body 10 kHz (min. input voltage 6Vpk-pk)
frequency
Battery voltage
2 % at 24 V Frequency measurement
measurement tolerance 1.5 %
tolerance
RTC battery lifetime Up to 10 years (20°C)

Note: RTC battery flat causes wrong Date&Time information only. D+ function
Max. D+ output current 300 mA
Operating conditions
Guaranteed level for
90% of supply voltage
Operating temperature -20 ˚C to +70 ˚C signal Charging OK
Storage temperature -30 ˚C to +80 ˚C
Analog inputs (Not electrically separated)
Humidity 95 % w/o condensation
Group 1 AI1 – AI4
Flash memory data
10 years Number of inputs 4 unipolar
retention time
Protection front panel IP 65 Resolution 0.1 Ω

Standard conformity Jumper selectable range V, Ω, mA

EN 61000-6-2 ed.3:06 Maximal resistance range 2500 Ω


Electromagnetic Maximal voltage range 4.0 V
EN 61000-6-4:07+A1:11
Compatibility
IEC 60533, Ed. 2; 1999-11 Maximal current range 0-20 mA

5-25 Hz, ±1.6 mm Input impedance 180 Ω for mA measuring


Vibration
25-100 Hz, a = 4 g Input impedance > 100 kΩ for V measuring

Shocks a = 200 m/s2 Resistance measurement


± 2 % ± 2 Ω out of measured value
tolerance
Heat radiation 3.5 W
Voltage measurement
± 1 % ± 1mV out of measured value
Dimensions and weight tolerance
Dimensions 183 × 123 × 47 mm Current measurement
± 1 % ± 0,5mA out of measured value
Weight 800 g tolerance
Group 2 AI5 – AI8
Binary inputs
Number of inputs 4 bipolar
Number of inputs 14 Resolution Up to 16 bits
Input impedance 4.7 kΩ Jumper selectable range V, Ω, mA, thermo coupler
Input range 0-36 V DC Maximal resistance range 2500 Ω
Switching voltage level 0-2 V DC close contact Maximal voltage range ±1000 mV / 100 mV / 5 V
Voltage level 8-36 V DC
Note: The maximal input voltage offset is in the range from
Minimal input duration 110 ms –2 to +5 V DC against controller minus power supply when
AI5 to AI8 is used for differential voltage measuring.
Binary open collector outputs
Number of outputs 14 ±0-20 mA active
Maximal current range
Maximum current - 0-20 mA passive
1A
outputs BO1, BO2
Input impedance 50 Ω for mA measuring
Maximum current -
5 A (60 °C), 4 A (70 °C) Input impedance >100 kΩ for V measuring
outputs BO3 - BO14
Resistance measurement
Maximum switching ±0.5 % ±2Ω out of measured value
36 VDC tolerance
voltage
Voltage measurement
±0.5 % ±1 mV out of measured value
RS232 interface tolerance

Maximal distance 10 m Current measurement


±0.5 % ±0.5 mA out of measured value
tolerance
Speed up to 115.2 kBd

InteliDrive DCU Marine - 3.8.0 Datasheet 2


Dimensions, terminals and mounting

InteliDrive DCU Marine - 3.8.0 Datasheet 3


Available extension modules
Product Description Order code

ID-RPU Redundant Protection Unit ID-RPU

ID-SCM, ID-SCM1 Speed Control Module ID-SCM, ID-SCM1


Communication Module with CAN and RS485/J1587 interface ID-COM
ID-COM
Communication Module with CAN1/CAN2/J1587 interface CM2J1708BZB

Inteli AIN8 8 Analog Input Channels and 1 RPM/Impulse Input Module I-AIN8

Inteli AIN8TC 8 Analog Channels Module I-AIN8TC

Inteli IO8/8 Binary Inputs/Outputs and Analog Outputs Module I-IO8/8

Inteli AIO9/1 Analog Input Output Module I-AIO9/1

IGS-PTM Analog/Binary Input/Output Module IGS-PTM

IS-AIN8 Analogue Input Module IS-AIN8

IS-AIN8TC Module for Thermocouple Measurement IS-AIN8TC

IS-BIN16/8 Binary Input/Output Module IS-BIN16/8

I-AOUT8 Analog Output Module I-AOUT8

IGL-RA15 Remote Annunciator EM2IGLRABAA

Related products
Product Description Order code

3G Communication Module with Cellular/Ethernet Connection IB-NT


4G EU market CM2IB4GEBFB
InternetBridge-NT
4G USA+Canada market CM2IB4GABFB
4G Japan market CM2IB4GJBFB
INTELIVISION 5
5.7“ colour display unit with buttons (can be equipped by backlit buttons and INTELIVISION 5 CAN
InteliVision 5
Marine certification) INTELIVISION 5 CAN
Backlit
Marine Approved 8" Colour Display Unit for InteliGen NT/InteliSys NT and
InteliVision 8 InteliVision 8 Marine
InteliDrive Family of Controllers
Industrial operator panel equipped with 12,1” colour, multi-touch screen -
InteliVision 12Touch OEM dedicated together with the main ComAp controller to visualise and control RD112OEMBZH
various applications
13.3" Marine certified Panel PC with multi-controller support and buttons for
InteliVision 13Touch RD1IV13TBME
brightness change on its front face.
I-CB/CAT DIESEL
I-CB/CAT GAS
I-CB/DEUTZTEM
I-CB ECU Communication Bridge I-CB/MODBUS
I-CB/MTU
I-CB/MTU ECS
I-CB/MTU SIAM4000

E-mail: [email protected]
Web: www.comap-control.com

© ComAp. Features and specification are subject to change without prior notice.
Certificates and standards
EN 61000-6-2 ed.3:06 BV

EN 61000-6-4:07+A1:11 ABS

UL 6200 C1D2

EN 60068-2-30:2005 RS
25/55°C, RH 95%, 48hours CCS
DNV CRS
LR RINA