Level Transducer                                                             Part # 2610523
KPSI Series 700 Submersible Level Transducer
                                                     These units are designed for installation in a Class
                                                     I, Division 1, Groups A, B, C and D, Class II,
                                                     Division 1, Groups E, F and G, Class III, division
                                                     1 hazardous location when connected to
                                                     appropriate apparatus. KPSI transducers are type
                                                     approved by the American Bureau of Shipping
                                                     and are UL, FM, and CSA
                                                     approved.
Specifications:
   •   Level Range:                  0 – 10 PSI
   •   Proof Pressure:        1.5 x FS
   •   Burst Pressure:        2.0 x FS
   •   Static Accuracy:              ±1.00 % FSO
   •   Resolution:                   Infinitesimal
   •   Wetted Materials:             316 stainless steel
   •   Compensated
   •   Temperature Range:            0 to 50 °C Open Face Nose Cap
   •   Thermal Error2:               ±0.054 % FSO / °C
   •   Operating
   •   Temperature Range:            -20 to 60 °C
   •   Excitation:                   9 – 30 VDC for mA, VDC and non-ratiometric mV output
   •   Input Current:                20 mA max. for mA output
   •   Output Current:               4 – 20 mA
   •   Zero Offset:                  ±0.125 mA for mA output
   •   Output Impedance:             See Loop Resistance Diagram
   •   Insulation Resistance:        100 mega ohm at 50 VDC
   •   Circuit Protection:           Polarity, surge / shorted output
   •   Approximate Weight:           0.44 lbs. (198 g) transducer
                                     0.05 lbs. (79 g) cable
Electrical Sensor Cable:
   •   Material:                      Chemical Resistant Polyurethane:
   •   Pull Strength:                 200 lbs. (90 kg)
   •   Conductors and size:           4 - 22 AWG [Min. 0.28” OD (7.10 mm) Max. 0.31” OD (7.87mm)
   •   Shield:                        36 gauge spiral tinned copper wire foil with drain wire.
   •   Weight:                        0.05 lbs. / ft. (0.07 kg/m)
   •   Vent Tube:                     Polyethylene .060” ID (1.52mm)
   DS                           2610523 KPSI 700 Level Transducer.DOC                          1 of 3
                              Copyright © 2008 Aqua-Aerobic Systems, Inc.                2008-03-06
Level Transducer                                                               Part # 2610523
KPSI Series 700 Submersible Level Transducer
Chemical resistance of polyurethane cable:
Potable Water, Wastewater, Borax, Butane, Animal Fat, Carbonic Acid, Citric Acid, Cod Liver Oil,
Glycerin, Glycol, Mineral Oils, Potassium Nitrate, Potassium Sulfate, Silicone Oils, Stoddard Solvent,
Tannic Acid (10), Tartaric Acid, Turbine Oil.
                          KPSI Series 700 Level Transducer – Dimensions
KPSI Part Number: 700-140-00010.000
Most installations of our submersible pressure transducers connect the polyurethane cable to a junction
box. From this junction box, users typically run their own cable to the required instrumentation. The
vented cable termination end is especially prepared at the factory to eliminate the potential for future
moisture migration down its length. It can be noticed where the lead wires emerge from under the jacket
that a potting material plus shrink tube “boot” have been added. Every effort should be made to leave
this feature intact. Should the cable be longer than is needed for the particular installation, it is
recommended that the excess length be accommodated in a service loop and that the potted end of cable
NOT be shortened.
The cable attached to this instrument is specifically engineered for submersible applications. The
polyurethane outer jacket provides long term reliability under most conditions. The cable should be
handled carefully, however, as the jacket may be subject to cutting should it be “raked” over extremely
sharp edges. To guard against water incursion should an inadvertent minor cut occur, we have
incorporated an exclusive “water block” feature immediately beneath the jacket. The cable is fully
shielded, with the shield connected to the metal housing at the transducer end and terminated in a drain
wire at the termination or user end. The shield should always be terminated to a good earth ground,
unless the transducer is installed in an area where galvanic corrosion is known to be a serious problem.
   DS                          2610523 KPSI 700 Level Transducer.DOC                            2 of 3
                            Copyright © 2008 Aqua-Aerobic Systems, Inc.                   2008-03-06
Level Transducer                                                                Part # 2610523
KPSI Series 700 Submersible Level Transducer
Accessories:
Features:
   • Small Size (1.47” diameter x 2.5” in height)
   • Maintenance-Free
   • Field installed to Sensor Cable vent tube
   • Includes short 3” length of DIN-3 rail, Mounting Clips
      and hardware.
The Series 815 sensitive aneroid bellows is compatible with all
KPSI submersible transducers and responds to changes in
atmospheric pressure ensuring reliable and accurate liquid
level measurements while remaining a closed system.
The aneroid bellows is a maintenance-free alternative to
traditional older technologies of inline desiccant cartridge
packs that require strict maintenance schedules for fault-free
operation and warranty protection. This widely used aneroid
bellows will prevent moisture from entering and condensing in the vent tube of a submersible pressure
transducer cable.
The aneroid bellows is constructed of a rugged yet flexible polymer material, which is compact in size
for ease of field-installation within a preferred mounting location inside a junction box or control panel.
The aneroid bellows device includes a bottom flexible extension that easily accepts the sensor cable vent
tub
   DS                          2610523 KPSI 700 Level Transducer.DOC                             3 of 3
                            Copyright © 2008 Aqua-Aerobic Systems, Inc.                    2008-03-06