specifications
Category 6 cable shall exceed IEC 61156-5 and TX6000 ™ Copper Cabling System
ANSI/TIA-568-C.2 Category 6 component standards.
The conductors shall be 23 AWG construction with HDPE TX6000 ™ UTP Copper Cable
insulation. The copper conductors shall be twisted in pairs,
with all four pairs separated by a cross-divider and covered CMR: PUR6004BU-FE**
by a flame-retardant PVC (CMR) jacket. Mini-Com ® TX6 ™ UTP PLUS
Jack Module
technical information Jack module: CJ688TG**
TX6 ™ PLUS UTP Patch Cords
Meter lengths: UTPSP^MY
Electrical Certified channel performance in a 4-connector configuration up to
performance: 100 meters and exceeds ISO 11801 Class E and ANSI/TIA-568-C.2 Foot lengths: UTPSP^^Y
Category 6 standards at swept frequencies up to 250 MHz DP6 ™ PLUS Angled Punchdown
Patch Panels
Certified component performance up to 100 meters and exceeds
the component requirement of IEC 61156-5 and ANSI/TIA-568-C.2 24-port, 1 RU: DPA24688TGY
Category 6 component standards at swept frequencies up to 250 MHz 48-port, 2 RU: DPA48688TGY
Conductor/ 23 AWG solid copper insulated with HDPE DP6 ™ PLUS Flat Punchdown
insulator:
Patch Panels
Flame rating: UL 1666
12-port: DP12688TGY
PoE compliance: Meets IEEE 802.3af and IEEE 802.3at for PoE applications
24-port, 1 RU: DP24688TGY
Installation 110 N (25 lbf) maximum
tension: 48-port, 2 RU: DP48688TGY
Temperature 0°C to 50°C (32°F to 122°F) during installation GP6 PLUS Category 6
™
Reelex™ packaging Ensures proper performance and provides quick installation ^For lengths 1 to 10 meters (increments of
one meter) and 0.5, 1.5, 2.5, 15, 20, 25, 30, 35,
Tested beyond the standards Cable has been characterized to 550 MHz, 300 MHz above the 40 meters, change the length designation in the
part number to the desired length. For standard
standard
cable colors other than Off White, add suffix
Descending length Easy identification of remaining cable reduces installation cable BL (Black), BU (Blue), RD (Red), GR (Green),
YL (Yellow), OR (Orange), or VL (Violet) after
markings time and cable scrap
the M in the part number. For example, the part
number for a blue 15-meter patch cord
applications is UTPCH15MBUY.
TX6000 ™ U/UTP Copper Cable is a component of the Panduit ® TX6000 ™ Copper Cabling System. ^^For lengths 1 to 10 feet (increments of
one foot) and 0.5, 1.5, 2.5, 15, 20, 25, 30, 35, 40
Interoperable and backward compatible, this end-to-end system provides design flexibility to protect network feet, change the length designation in the part
investments well into the future. With certified performance to the ISO 11801 Class E and ANSI/TIA-568-C.2 number to the desired length. For standard cable
Category 6 standards, this system is ideal for today’s high performance workstation applications. Usage of colors other than Off White, add suffix
the TX6000 ™ Copper Cabling System include: BL (Black), BU (Blue), RD (Red), YL (Yellow),
GR (Green), OR (Orange), or VL (Violet) before
• Ethernet 10BASE-T, 100BASE-T (Fast Ethernet), 1000BASE-T (Gigabit Ethernet), the Y at the end of the part number. For example,
10GBASE-T (10 Gigabit Ethernet over limited distances as specified in the industry 10GBASE-T the part number for a blue 5-foot patch cord
standards) is UTPSP5BUY.
• 155 Mb/s ATM, 622 Mb/s ATM,
1.2 Gb/s ATM
• Token Ring 4/16
w w w . pa n d u it.c om
TX6000™ Enhanced Category 6 U/UTP Copper Cable
Additional Specifications
Mechanical Test
Ultimate Breaking Strength >400 N (90 lbf)
Minimum Bend Radius 4 x cable diameter
Electrical Test
Nominal Velocity of Propagation (NVP) 67%
Cable Construction
Jacket
Conductor Wire
Cross Divider
Conductor
Insulator
Rip Cord